首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The separation of the enantiomers of 17 chiral sulfoxides was studied on polysaccharide‐based chiral columns in polar organic mobile phases. Enantiomer elution order (EEO) was the primary objective in this study. Two of the six chiral columns, especially those based on amylose tris(3,5‐dimethylphenylcarbamate) and cellulose tris(4‐chloro‐3‐methylphenylcarbamate) (Lux Cellulose‐4) proved to be most successful in the separation of the enantiomers of the studied sulfoxides. Interesting examples of EEO reversal were observed depending on the chiral selector or the composition of the mobile phase. For instance, the R‐(+) enantiomer of lansoprazole eluted before the S‐(?) enantiomer on Lux Cellulose‐1 in both methanol or ethanol as the mobile phase, while the elution order was opposite in the same eluents on amylose tris(3,5‐dimethylphenylcarbamate) with the S‐(?) enantiomer eluting before the R‐(+) enantiomer. The R‐(+) enantiomer of omeprazole eluted first on Lux Amylose‐2 in methanol but it was second when acetonitrile was used as the mobile phase with the same chiral selector. Several other examples of reversal in EEO were observed in this study. An interesting example of the separation of four stereoisomers of phenaminophos sulfoxide containing chiral sulfur and phosphor atoms is also reported here.  相似文献   

2.
Enantioseparation of limonene‐based bicyclic 1,3‐aminoalcohols and 1,3,5‐ and 1,3,6‐aminodiols was performed by normal‐phase high‐performance liquid chromatographic and supercritical fluid chromatographic (SFC) methods on polysaccharide‐based chiral stationary phases. The effects of the composition of the mobile phase, the column temperature and the structures of the analytes and chiral selectors on retention and selectivity were investigated by normal‐phase LC and SFC technique. Thermodynamic parameters derived from selectivity–temperature‐dependence studies were found to be dependent on the chromatographic method applied, the nature of the chiral selector and the structural details of the analytes. Enantiorecognition in most cases was enthalpically driven but an unusual temperature behavior was also observed: decreased retention times were accompanied by improved separation factors with increasing temperature, i.e. some entropically driven separations were also observed. The elution sequence was determined in all cases. The separation of the stereoisomers was optimized in both chromatographic modalities.  相似文献   

3.
4.
An LC method was developed and prevalidated for the enantiomeric purity determination of S‐amlodipine in polar organic solvent chromatography using a chlorine‐containing cellulose‐based chiral stationary phase (CSP). The concentration of formic acid (FA) (0.01–0.2%) in the mobile phase containing acetonitrile as the main solvent was found to influence the elution order of amlodipine enantiomers as well as the enantioresolution. A reversal of the enantiomer elution order of amlodipine was only observed with chiral stationary phases with both electron‐withdrawing (chloro) and electron‐donating groups (methyl) on the phenyl moieties of the chiral selector, namely cellulose tris(3‐chloro‐4‐methylphenylcarbamate) and cellulose tris(4‐chloro‐3‐methylphenylcarbamate). The highest enantioresolution (Rs: 4.1) value was obtained at the lowest FA concentration (0.01%) using cellulose tris(4‐chloro‐3‐methylphenylcarbamate) as the chiral selector and the enantiomeric impurity, R‐amlodipine, eluted first under these conditions. Therefore, the mobile phase selected for the prevalidation of the method consisted of ACN/0.1% DEA/0.01% FA and the temperature was set at 25°C. The method was prevalidated by means of the strategy based on the total measurement error and the accuracy profile. The method was found to be selective and the limit of quantification was found to be about 0.05% for R‐amlodipine, while the limit of detection was close to 0.02%.  相似文献   

5.
The separation of enantiomers of five chiral dihydropyridine derivatives was studied on five different polysaccharide‐based chiral HPLC columns with various normal‐phase (NP), polar organic, and reversed‐phase eluents. Along with the successful separation of analyte enantiomers, the emphasis of this study was on enantiomer elution order (EEO) with various columns and mobile phase composition. The interesting phenomenon of reversal of EEO, recently reported in the case of amlodipine (AML) depending on the concentration of formic acid in acetonitrile, was also confirmed with NP eluents. Under RP conditions at relatively low water content, the EEO of AML could also be reverted by varying the concentration of formic acid in the mobile phase. However, at higher water content the same parameter did not affect the EEO, but only induced gradual decrease in resolution up to complete co‐elution of enantiomers. Additionally, in organic‐aqueous mobile phases retention factors decreased with increasing water content but only up to 20% (v/v), while above this concentration the expected typical RP behavior was observed. The presence of the commonly used additive diethylamine in the mobile phase seems important for observing a reversal in EEO with increasing concentration of formic acid. The reversal of the EEO was characteristic of AML only and was not observed for any of other dihydropyridines included in this study.  相似文献   

6.
N‐(2,4‐dinitrophenyl)‐proline and N‐(2,4‐dinitrophenyl)‐serine were enantiomerically resolved on the BSA chiral stationary phase by HPLC in reversed‐phase mode. Effects of chromatographic conditions on enantioseparation and elution order have been investigated in detail. For these two samples, reversal of enantiomer elution order was observed by changing buffer pH, the content of acetonitrile, or alcohol modifiers in mobile phase, which is firstly reported in the BSA chiral stationary phase studies. More interestingly, combined effect between buffer pH and the content of acetonitrile was also observed. In addition, coelution range of enantiomers varied along with the content of acetonitrile in mobile phase.  相似文献   

7.
A comprehensive study into the effects of mobile phase composition and column temperature on enantiomer elution order was conducted with a set of chiral rod-like liquid crystalline materials. The analytes were structurally similar and comprised variances such as length of terminal alkyl chain, presence of chlorine, number of phenyl rings, and type of chiral center. Experiments were carried out in polar organic and reversed-phase modes using amylose tris(3-chloro-5-methylphenylcarbamate) immobilized on silica gel as the chiral stationary phase. For all liquid crystals, reversal of elution order of enantiomers was observed based on type of used cosolvent and/or its content in the mobile phase; for some of the liquid crystals a temperature-induced reversal was also observed. Both linear and nonlinear dependencies of natural logarithm of enantioselectivity on temperature were found. Tested mobile phases comprised pure organic solvents and binary and tertiary mixtures of acetonitrile with organic solvents and/or water. Effect of acidic/basic mobile phase additives was also tested. Effect of structure of chiral selector is briefly discussed.  相似文献   

8.
The eight stereoisomers of limonene‐based carbocyclic β‐amino acids containing three chiral centers have been directly separated on chiral stationary phases containing Cinchona alkaloid‐based zwitterionic selectors. The effects of bulk solvent composition of the mobile phase, the nature of base additives, counterion concentration, and the structure of selector on the enantiorecognition were studied. Experiments were performed at constant mobile phase composition in the temperature range 5–40°C to study the effect of temperature. Thermodynamic parameters were calculated on the basis of the plots of ln α versus 1/T curves. The enthalpically or entropically driven enantioseparations were found to depend strongly on the structures of analyte and selector. The eight stereoisomers of limonene‐based carbocyclic β‐amino acids could be differentiated as well‐separated peaks in a traditional 1D chromatographic system in two runs by applying the two complementary ZWIX(+)™ and ZWIX(–)™ columns.  相似文献   

9.
The stereoisomers of 1,2,3,4‐tetrahydroisoquinoline amino alcohol analogues and derivatives thereof were separated in normal‐phase mode on chiral stationary phases based on preprepared silica coated with cellulose tris‐(3,5‐dimethylphenyl carbamate), cellulose tris‐(3‐chloro‐4‐methylphenyl carbamate), cellulose tris‐(4‐methylbenzoate) or cellulose tris‐(4‐chloro‐3‐methylphenyl carbamate). On all the investigated chiral columns, the retention and the enantioseparation were influenced by the nature and the concentrations of the mobile phase components and additives, and also the temperature. Experiments were performed in the temperature range 10–50°C. Thermodynamic parameters were calculated from plots of lnα vs 1/T. On these polysaccharide‐based chiral columns, both enthalpy‐driven separations and entropy‐controlled enantioseparations were observed. The latter was advantageous with regard to the shorter retention and greater selectivity at high temperature. The sequence of elution of the stereoisomers was determined in all cases. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
RP high‐performance liquid chromatographic methods were developed for the enantioseparation of eleven unusual β2‐homoamino acids. The underivatized analytes were separated on a chiral stationary phase containing (+)‐(18‐crown‐6)‐2,3,11,12‐tetracarboxylic acid as chiral selector. The effects of organic (alcoholic) and acidic modifiers, the mobile phase composition and temperature on the separation were investigated. The structures of the substituents in the α‐position of the analytes substantially influenced the retention and resolution. The elution sequence was determined in some cases: the S enantiomers eluted before the R enantiomers.  相似文献   

11.
The enantiomeric resolution of N-t-butyloxycarbonyl (N-t-Boc) amino acids D/L isomers by reversed-phase HPLC was investigated using cyclodextrins (CD's) as chiral selectors for the mobile phase. The use of a low pH (pH<4) for the mobile phase enabled the enantioseparation of N-t-Boc amino acids. The opposite elution order of D/L isomers was observed when hydroxypropyl-derivatized beta-CD was used instead of native beta-CD. A computer simulation of the enantioseparation showed that the ratio of the retention factors of the chiral selector and the sample determined the elution order and the resolution. When the retention factor of the chiral selector is smaller than that of the sample, an isomer having larger complex formation constant eluted faster. However, when the chiral selector had a larger retention factor than the sample, an opposite elution order of the isomers was obtained. The large difference in the retention factors between the chiral selector and the sample led to good enantiomeric separation.  相似文献   

12.
The resolving power of a new commercial polysaccharide‐based chiral stationary phase, Sepapak‐4, with cellulose tris(4‐chloro‐3‐methylphenylcarbamate) coated on silica microparticles as chiral selector, was evaluated toward the enantioseparation of ten basic drugs with widely different structures and hydrophobic properties, using ACN as the main component of the mobile phase. A multivariate approach (experimental design) was used to screen the factors (temperature, n‐hexane content, acidic and basic additives) likely to influence enantioresolution. Then, the optimization was performed using a face‐centered central composite design. Complete enantioseparation could be obtained for almost all tested chiral compounds, demonstrating the high chiral discrimination ability of this chiral stationary phase using polar organic mobile phases made up of ACN and containing an acidic additive (TFA or formic acid), 0.1% diethylamine and n‐hexane. These results clearly illustrate the key role of the nature of the acidic additive in the mobile phase.  相似文献   

13.
Liquid chromatographic separation of stereoisomers of darunavir on Chiralpak AD‐H, a column containing the stationary phase coated with amylose tris(3,5‐dimethylphenylcarbamate) as a chiral selector, was studied under normal‐phase conditions at different temperatures between 20 and 50°C. The effect of quality and quantity of different polar organic modifiers viz: methanol, ethanol, 1‐propanol, and 2‐propanol in the mobile phase as well as column temperature on retention, separation, and resolution was investigated and optimized. The optimum separation was accomplished using a mobile phase composed of n‐hexane/ethanol/diethyl amine (80:20:0.1 v/v/v) at 40°C. Apparent thermodynamic parameters ΔH0 and ΔS* were derived from the Van't Hoff plots (lnk′ versus 1/T) and used to explain the strength of interactions between the stereoisomers and amylose tris(3,5‐dimethylphenylcarbamate) coated chiral stationary phase.  相似文献   

14.
Recycling high‐speed counter‐current chromatography was successfully applied to the preparative separation of oxybutynin enantiomers. The two‐phase solvent system consisted of n‐hexane, methyl tert‐butyl ether, and 0.1 mol/L phosphate buffer solution (pH = 5.0) with the volume ratio of 6:4:10. Hydroxypropyl‐β‐cyclodextrin was employed as the chiral selector. The influence of factors on the chiral separation process, including the concentration of chiral selector, the equilibrium temperature, the pH value of the aqueous phase were investigated. Under optimum separation conditions, 15 mg of oxybutynin racemate was separated with the purities of both the enantiomers over 96.5% determined by high‐performance liquid chromatography. Recovery for the target compounds reached 80–82% yielding 6.00 mg of (R)‐oxybutynin and 6.15 mg of (S)‐oxybutynin. Technical details for recycling elution mode were discussed.  相似文献   

15.
An investigation on the high‐performance liquid chromatography enantioseparation of 12 polyhalogenated 4,4′‐bipyridines on polysaccharide‐based chiral stationary phases is described. The overall study was directed toward the generation of efficient separations in order to obtain pure atropisomers that will serve as ligands for building homochiral metal organic frameworks. Four coated columns—namely, Lux Cellulose‐1, Lux Cellulose‐2, Lux Cellulose‐4, and Lux Amylose‐2—and two immobilized columns—namely, Chiralpak IC and IA—were used under normal, polar organic, and reversed‐phase elution modes. Moreover, Chiralcel OJ was considered under normal‐phase and polar organic conditions. The effect of the chiral selector and mobile phase composition on the enantioseparation, the enantiomer elution order and the beneficial effect of nonstandard solvents were studied. The effect of water in the mobile phase on the enantioselectivity and retention was investigated and retention profiles typical of hydrophilic interaction liquid chromatography were observed. Interesting phenomena of solvent‐induced enantiomer elution order reversal occurred under normal‐phase mode. All the considered 4,4′‐bipyridines were enantioseparated at the multimilligram level.  相似文献   

16.
This work concentrates on extending the utilization of multiple dual mode (MDM) counter‐current chromatography in chiral separations. Two aromatic acids, 2‐(6‐methoxy‐2‐naphthyl)propionic acid (NAP) and 2‐phenylpropionic acid (2‐PPA), were enantioseparated by MDM counter‐current chromatography using hydroxypropyl‐β‐cyclodextrin (HP‐β‐CD) as chiral selector. The two‐phase solvent systems consisting of n‐hexane/ethyl acetate 0.1 mol/L phosphate buffer pH 2.67 containing 0.1 mol/L HP‐β‐CD (7.5:2.5:10 for NAP and 7:3:10 for 2‐PPA, v/v/v) were used. Conventional MDM and modified MDM were compared according to peak resolution under current separation mechanism. The influence of elution time after the first‐phase inversion and number of cycles for MDM were investigated. Peak resolution of NAP and 2‐PPA increased from 0.62 to 1.05 and 0.72 to 0.84, respectively, using optimized MDM conditions. Being an alternative elution method for counter‐current chromatography, MDM elution greatly improved peak resolution in chiral separations.  相似文献   

17.
Complementary techniques were applied for the investigation of the chiral recognition and enantiomeric resolution of lenalidomide using various cyclodextrins and polysaccharides as chiral selectors. The high‐performance liquid chromatography enantioseparation of the anticancer drug was achieved using polysaccharide‐type chiral stationary phases in polar organic mode. Elution order and absolute configuration were elucidated by combined circular dichroism spectroscopy and time‐dependent density functional theory calculations after the isolation of pure enantiomers. Chiral selector dependent and mobile‐phase dependent reversal of the enantiomer elution order was observed, and the nonracemic nature of the lenalidomide sample was also demonstrated. Eight anionic cyclodextrins were screened for their ability to discriminate between the uncharged enantiomers by using capillary electrophoresis. Only two derivatives presented chiral interactions, these cases being interpreted in terms of apparent stability constants and complex mobilities. The best results were delivered by sulfobutylether‐β‐cyclodextrin, where quasi‐equal stability constants were recorded and the enantiodiscrimination process was mainly driven by different mobilities of the transient diastereomeric complexes. The optimized high‐performance liquid chromatography (Chiralcel OJ column, pure ethanol with 0.6 mL/min flow rate, 40°C) and capillary electrophoresis methods (30 mM sulfobutylether‐β‐cyclodextrin, 30 mM phosphate pH 6.5, 12 kV applied voltage, 10°C) were validated for the determination of 0.1% (R)‐lenalidomide as a chiral impurity, which could be important if a racemic switch is achieved.  相似文献   

18.
Direct separation of the enantiomers of amino acid amines, amino alcohols, and diamines was performed on recently developed chiral stationary phases containing isopropyl carbamate-cyclofructan 6 (IP-CF6), (R)-naphthylethylcarbamate cyclofructan 6 (RN-CF6), or dimethylphenylcarbamate cyclofructan 7 (DMP-CF7) as chiral selectors, using n-hexane/alcohol/TFA as mobile phase. The effects of the mobile phase composition, the nature and concentrations of the alcoholic and acidic modifiers, and the structures of the analytes on the retention and resolution were investigated. In some cases, separations were carried out at constant mobile phase composition in the temperature range 5-40 °C. Thermodynamic parameters and T(iso) values were calculated from plots of lnk versus 1/T. It was found that the enantioseparations were enthalpy driven. The sequences of elution of the stereoisomers were determined but no general rule could be established.  相似文献   

19.
The HPLC enantioseparation of nine atropisomeric 3,3′,5,5′‐tetrasubstituted‐4,4′‐bipyridines was performed in normal and polar organic (PO) phase modes using two immobilized polysaccharide‐based chiral columns, namely, Chiralpak IA and Chiralpak IC. The separation of all racemic analytes, the effect of the chiral selector, and mobile phase (MP) composition on enantioseparation and the enantiomer elution order (EEO) were studied. The beneficial effect of nonstandard solvents, such as tetrahydrofuran (THF), dichloromethane (DCM), and methyl t‐butyl ether on enantioseparation was investigated. All selected 4,4′‐bipyridines were successfully enantioseparated on Chiralpak IA under normal or PO MPs with separation factors from 1.14 to 1.70 and resolutions from 1.3 to 6.5. Two bipyridines were enantioseparated at the multimilligram level on Chiralpak IA. Differently, Chiralpak IC was less versatile toward the considered class of compounds and only five bipyridines out of nine could be efficiently separated. In particular, on these columns, the ternary mixture n‐heptane/THF/DCM (90:5:5) as MP had a positive effect on enantioseparation. An interesting phenomenon of reversal of the EEO depending on the composition of the MP for the 3,3′‐dibromo‐5,5′‐bis‐(E)‐phenylethenyl‐4,4′‐bipyridine along with an exceptional enantioseparation for the 3,3′‐dibromo‐5,5′‐bis‐ferrocenylethynyl‐4,4′‐bipyridine (α = 8.33, Rs = 30.6) were observed on Chiralpak IC.  相似文献   

20.
The stereoisomers of five fluorinated cyclic β3‐amino acid derivatives and their nonfluorinated counterparts were separated on chiral stationary phases containing as chiral selectors cellulose tris‐(3,5‐dimethylphenyl carbamate), cellulose tris‐(3‐chloro‐4‐methylphenyl carbamate), cellulose tris‐(4‐methylbenzoate), cellulose tris‐(4‐chloro‐3‐methylphenyl carbamate), amylose tris‐(3,5‐dimethylphenyl carbamate) or amylose tris‐(5‐chloro‐2‐methylphenyl carbamate). The enantioseparations were carried out in normal‐phase mode with n‐hexane/alcohol/alkylamine mobile phases in the temperature range 5–40 °C. The effects of the mobile phase composition, the nature and concentration of the alcohol and alkylamine additives, the structures of the analytes and temperature on the separations were investigated. Thermodynamic parameters were calculated from plots of ln α vs. 1/T. The Δ(ΔH°) values ranged between ?5.0 and +1.6 kJ/mol, while Δ(ΔS°) varied between ?12.6 and +5.7 J/mol/K. The enantioseparation was enthalpically controlled, the retention factor and the separation factor decreasing with increasing temperature, but entropically controlled separation was also observed. The elution sequence was determined for all of the investigated analytes. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号