首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Maltol, ethyl maltol, vanillin, and ethyl vanillin are important food additives as flavor enhancers. To quantify the four additives in milk powder, a novel 2D liquid chromatographic (2DLC) method was developed in this article. In such a 2DLC system, the target fractions eluted from the first dimensional column (C4) are stored onto the trapping column (C8) for subsequent analysis; after that, they were switched into the second dimensional column (C18) by a two‐position six‐port switching valve. A one‐step sample preparation method was used prior to 2DLC chromatographic analysis, which was easy and convenient. After optimization of all experimental parameters, the new method was validated in terms of linearity, LODs, and LOQs, intra‐ and interday precision, and accuracy. A conventional single‐dimensional liquid chromatographic method was also proposed in this work for comparison. In order to evaluate the applicability of the new 2DLC method, five brands of commercial milk powder samples (n = 8) were analyzed. Vanillin and ethyl vanillin were detected in two samples, respectively. It is showed that the 2DLC method is effective in quality control programs of milk powder products.  相似文献   

2.
This study discusses the design aspects for the construction of a microfluidic device for comprehensive spatial two‐dimensional liquid chromatography. In spatial two‐dimensional liquid chromatography each peak is characterized by its coordinates in the plane. After completing the first‐dimension separation all fractions are analyzed in parallel second‐dimension separations. Hence, spatial two‐dimensional liquid chromatography potentially provides much higher peak‐production rates than a coupled column multi‐dimensional liquid chromatography approach in which the second‐dimension analyses are performed sequentially. A chip for spatial two‐dimensional liquid chromatography has been manufactured from cyclic olefin copolymer and features a first‐dimension separation channel and 21 parallel second‐dimension separation channels oriented perpendicularly to the former. Compartmentalization of first‐ and second‐dimension developments by physical barriers allowed for a preferential flow path with a minimal dispersion into the second‐dimension separation channels. To generate a homogenous flow across all the parallel second‐dimension channels, a radially interconnected flow distributor containing two zones of diamond‐shaped pillars was integrated on‐chip. A methacrylate ester based monolithic stationary phase with optimized macroporous structure was created in situ in the confines of the microfluidic chip. In addition, the use of a photomask was explored to localize monolith formation in the parallel second‐dimension channels. Finally, to connect the spatial chip to the liquid chromatography instrument, connector ports were integrated allowing the use of Viper fittings. As an alternative, a chip holder with adjustable clasp locks was designed that allows the clamping force to be adjusted.  相似文献   

3.
Two‐dimensional liquid chromatography largely increases the number of separated compounds in a single run, theoretically up to the product of the peaks separated in each dimension on the columns with different selectivities. On‐line coupling of a reversed‐phase column with an aqueous normal‐phase (hydrophilic interaction liquid chromatography) column yields orthogonal systems with high peak capacities. Fast on‐line two‐dimensional liquid chromatography needs a capillary or micro‐bore column providing low‐volume effluent fractions transferred to a short efficient second‐dimension column for separation at a high mobile phase flow rate. We prepared polymethacrylate zwitterionic monolithic micro‐columns in fused silica capillaries with structurally different dimethacrylate cross‐linkers. The columns provide dual retention mechanism (hydrophilic interaction and reversed‐phase). Setting the mobile phase composition allows adjusting the separation selectivity for various polar substance classes. Coupling on‐line an organic polymer monolithic capillary column in the first dimension with a short silica‐based monolithic column in the second dimension provides two‐dimensional liquid chromatography systems with high peak capacities. The silica monolithic C18 columns provide higher separation efficiency than the particle‐packed columns at the flow rates as high as 5 mL/min used in the second dimension. Decreasing the diameter of the silica monolithic columns allows using a higher flow rate at the maximum operation pressure and lower fraction volumes transferred from the first, hydrophilic interaction dimension, into the second, reversed‐phase mode, avoiding the mobile phase compatibility issues, improving the resolution, increasing the peak capacity, and the peak production rate.  相似文献   

4.
An orthogonal (71.9%) off‐line preparative two‐dimensional normal‐phase liquid chromatography/reversed‐phase liquid chromatography method coupled with effective sample pretreatment was developed for separation and purification of flavonoids from licorice. Most of the nonflavonoids were firstly removed using a self‐made Click TE‐Cys (60 μm) solid‐phase extraction. In the first dimension, an industrial grade preparative chromatography was employed to purify the crude flavonoids. Click TE‐Cys (10 μm) was selected as the stationary phase that provided an excellent separation with high reproducibility. Ethyl acetate/ethanol was selected as the mobile phase owing to their excellent solubility for flavonoids. Flavonoids co‐eluted in the first dimension were selected for further purification using reversed‐phase liquid chromatography. Multiple compounds could be isolated from one normal‐phase fraction and some compounds with bad resolution in one‐dimensional liquid chromatography could be prepared in this two‐dimensional system owing to the orthogonal separation. Moreover, this two‐dimensional liquid chromatography method was beneficial for the preparation of relatively trace flavonoid compounds, which were enriched in the first dimension and further purified in the second dimension. Totally, 24 flavonoid compounds with high purity were obtained. The results demonstrated that the off‐line two‐dimensional liquid chromatography method was effective for the preparative separation and purification of flavonoids from licorice.  相似文献   

5.
An online high‐pH reversed‐phase liquid chromatography× low‐pH reversed‐phase liquid chromatography tandem electrospray ionization mass spectrometry combined with pulse elution gradient in the first dimension was constructed to separate and identify alkaloids from Macleaya cordata (willd.) R. Br. The modulation was performed by using a dual second dimensional columns interface combined with a make‐up dilution pump, which is responsible for dilution and neutralization of the first dimensional effluent, and the dual second dimensional columns integrated the trapping and the separation function to reduce the second dimension system dead volume. Taking advantage of the dissociable characteristics of alkaloids, mobile phases with different pH values were applied in the first dimension (pH 9.0) and the second dimension (pH 2.6) to improve the orthogonality of two‐dimension separation. Besides, the pulse elution gradient in first dimension and second dimensional gradient were carefully optimized and much better separation was achieved compared to the separation with the traditional two‐dimensional liquid chromatography approach. Finally, mass measurement was performed for alkaloids in M. cordata (willd.) R. Br. by coupling proposed two‐dimensional liquid chromatography system with triple quadrupole mass spectrometry, and 39 alkaloids were successfully identified by comparing the obtained result with the former reported results.  相似文献   

6.
An effective two‐dimensional liquid chromatography method has been established for the analysis of all‐trans‐astaxanthin and its geometric isomers from Phaffia rhodozyma employing a C18 column at the first dimension and a C30 column in the second dimension, connected by a 10‐port valve using the photo‐diode array detector. The regression equation of astaxanthin calibration curve was established, and the precision and accuracy values were found to be in the range of 0.32–1.14% and 98.21–106.13%, respectively. By using two‐dimensional liquid chromatography, it was found that day light, ultrasonic treatment, and heat treatment have significant influence on the content of all‐trans‐astaxanthin in the extract from P. rhodozyma due to the transformation of all‐trans‐astaxanthin to cis‐astaxanthin. The day light and ultrasonic treatments more likely transform all‐trans‐astaxanthin to 9‐cis‐astaxanthin, and the thermal treatment transforms all‐trans‐astaxanthin to 13‐cis‐astaxanthin. These results indicate that the two‐dimensional liquid chromatography method can facilitate monitoring astaxanthin isomerization in the raw extract from P. rhodozyma. In addition, the study will provide a general reference for monitoring other medicals and bioactive chemicals with geometric isomers.  相似文献   

7.
An orthogonal two‐dimensional solid‐phase extraction strategy was established for the selective enrichment of three aminoglycosides including spectinomycin, streptomycin, and dihydrostreptomycin in milk. A reversed‐phase liquid chromatography material (C18) and a weak cation‐exchange material (TGA) were integrated in a single solid‐phase extraction cartridge. The feasibility of two‐dimensional clean‐up procedure that experienced two‐step adsorption, two‐step rinsing, and two‐step elution was systematically investigated. Based on the orthogonality of reversed‐phase and weak cation‐exchange procedures, the two‐dimensional solid‐phase extraction strategy could minimize the interference from the hydrophobic matrix existing in traditional reversed‐phase solid‐phase extraction. In addition, high ionic strength in the extracts could be effectively removed before the second dimension of weak cation‐exchange solid‐phase extraction. Combined with liquid chromatography and tandem mass spectrometry, the optimized procedure was validated according to the European Union Commission directive 2002/657/EC. A good performance was achieved in terms of linearity, recovery, precision, decision limit, and detection capability in milk. Finally, the optimized two‐dimensional clean‐up procedure incorporated with liquid chromatography and tandem mass spectrometry was successfully applied to the rapid monitoring of aminoglycoside residues in milk.  相似文献   

8.
In the present work, a novel method to extract three kinds of spices, namely vanillin, ethyl vanillin and ethyl maltol from food products such as biscuit, chocolate and milk powder was developed. 1-Octyl-3-methylimidazolium chloride([Omim]Cl) aqueous solution was selected as the extracting medium. A 0.5 g powder of food product was extracted by 5.0 mL of [Omim]Cl aqueous solution(0.3 mol/L, pH 6.0) under ultrasonication at 50 8C, and then the extract was centrifuged for 10 min at 4000 rpm. The extract was filtered through a syringe filter and injected into ion chromatography system for analysis. The separation of the three spices was carried out on an anion exchange column. The detection wavelength was set at 280 nm. Compared with traditional extraction solvents, [Omim]Cl aqueous solution displayed particular advantages. The applicability of the proposed method to real sample was confirmed. Under the optimal conditions, good reproducibility of extraction performance was obtained, with the relative standard deviation(RSD) values ranging from 1.9% to 6.3%. The recoveries of spiked samples were between 79.8% and 95.8%. The detection limits(LOD, S/N = 3) of vanillin, ethyl vanillin and ethyl maltol were in the range of 20–45 mg/kg. The use of ionic liquid aqueous solution as extraction solvent was operationally easy and environmental-friendly.  相似文献   

9.
超高效液相色谱-串联质谱法同时测定食品中4种常用香精   总被引:2,自引:0,他引:2  
杨华梅  杭莉 《色谱》2015,33(3):250-255
建立了超高效液相色谱-串联质谱法同时测定食品中香兰素、乙基香兰素、麦芽酚和乙基麦芽酚4种香精的方法。样品用水提取,固相萃取小柱净化,目标化合物采用UPLCTMBEH C18色谱柱(50 mm×2.1 mm, 1.7 μm)分离,以甲醇和含0.002 mol/L乙酸铵及0.1%(v/v)甲酸的水溶液为流动相进行梯度洗脱,采用电喷雾离子源电离、正离子多反应监测模式质谱检测。4种香精在5~500 μg/L或10~1000 μg/L质量浓度范围内线性良好,相关系数均在0.9995~0.9998之间;回收率为75.8%~116%,相对标准偏差(RSD, n=6)为1.58%~4.01%。该方法灵敏、准确,检测范围广,分析速度快,适合食品中香兰素、乙基香兰素、麦芽酚和乙基麦芽酚4种香精的检测。  相似文献   

10.
In this study, an improved online comprehensive two‐dimensional liquid chromatography platform coupled to tandem mass spectrometry was developed for the analysis of complex polyphenolic samples. A narrowbore hydrophilic interaction chromatography column (150 × 2.0 mm, 3.0 μm, cross‐linked diol) was employed in the first dimension, while a reversed‐phase column based on monodisperse sub‐2 μm fully porous particles (50 × 3.0 mm, 1.9 μm d.p.) with high surface area (410 m2/g) was employed in the second dimension. The combination of a trapping column modulation interface with the high retentive fully porous monodisperse reversed‐phase column in the second dimension resulted in higher peak capacity values (1146 versus 867), increased sensitivity, sharper and more symmetrical peaks in comparison with a conventional loop‐based method, with the same analysis time (70 min). The system was challenged against a complex polyphenolic extract of a typical Italian apple cultivar, enabling the simultaneous separation of multiple polyphenolic classes, including oligomeric procyanidins, up to degree of polymerization of 10. Hyphenation with an ion trap time‐of‐flight mass spectrometer led to the tentative identification of 121 analytes, showing how this platform could be a powerful analytical tool for the accurate profiling of complex polyphenolic samples.  相似文献   

11.
Block copolymers of ethylene oxide and ε‐caprolactone were synthesized by microwave‐assisted polymerization of ε‐caprolactone with polyethylene glycol monomethyl ethers as initiator. The samples thus obtained were characterized by two‐dimensional liquid chromatography with liquid chromatography at critical conditions as the first and liquid exclusion adsorption chromatography as the second dimension. A full baseline separation of all oligomers could be achieved in both dimensions.  相似文献   

12.
This paper explores the analytical figures of merit of two‐dimensional high‐performance liquid chromatography for the separation of antioxidant standards. The cumulative two‐dimensional high‐performance liquid chromatography peak area was calculated for 11 antioxidants by two different methods—the areas reported by the control software and by fitting the data with a Gaussian model; these methods were evaluated for precision and sensitivity. Both methods demonstrated excellent precision in regards to retention time in the second dimension (%RSD below 1.16%) and cumulative second dimension peak area (%RSD below 3.73% from the instrument software and 5.87% for the Gaussian method). Combining areas reported by the high‐performance liquid chromatographic control software displayed superior limits of detection, in the order of 1 × 10?6 M, almost an order of magnitude lower than the Gaussian method for some analytes. The introduction of the countergradient eliminated the strong solvent mismatch between dimensions, leading to a much improved peak shape and better detection limits for quantification.  相似文献   

13.
An improved sample preparation method was developed to enhance acrylamide recovery in high‐fat foods. Prior to concentration, distilled deionized water was added to protect acrylamide from degradation, resulting in a higher acrylamide recovery rate from fried potato chips. A Chrome‐Matrix C18 column (2.6 μm, 2.1 × 100 mm) was used for the first time to analyze acrylamide levels using ultra high performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry, displaying good separation of acrylamide from interference. A solid‐phase extraction procedure was avoided, and an average recovery of >89.00% was achieved from different food matrices for three different acrylamide spiking levels. Good reproducibility was observed, with an intraday relative standard deviation of 0.04–2.38%, and an interday relative standard deviation of 2.34–3.26%. Thus, combining the improved sample preparation method for acrylamide analysis with the separation on a Chrome‐Matrix C18 column (2.6 μm, 2.1 × 100 mm) using ultra high performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry is highly useful for analyzing acrylamide levels in complex food matrices.  相似文献   

14.
A novel on‐line three‐dimensional liquid chromatography method was developed to separate four main flavonoids from Rhodiola rosea. Ethyl acetate/0.5 mol/L ionic liquid 1‐butyl‐3‐methylimidazolium chloride aqueous solution was selected as the solvent system. In the first‐dimension separation, the target flavonoids were entrapped and subsequently desorbed into the second‐dimension high‐speed countercurrent chromatographic column for separation. In the third‐dimension chromatography, the residual ionic liquid in the four separated flavonoids was removed and the used ionic liquid was recovered. As a result, 35.1 mg of compound 1 , 20.4 mg of compound 2 , 8.5 mg of compound 3, and 10.6 mg of compound 4 were obtained from 1.53 g R. rosea extract. They were identified as rhodiosin, rhodionin, herbacetin, and kaempferol, respectively. The recovery of ionic liquid reached 99.1% of the initial amount. The results showed that this method is a powerful technology for the separation of R. rosea flavonoids and that the ionic‐liquid‐based solvent system has advantages over traditional solvent systems in renewable and environmentally friendly properties.  相似文献   

15.
This work reports the use of two‐dimensional (2D) liquid chromatography system coupled with a tandem mass spectrometry for the quantification of ampicillin in bovine milk. A restrict access media column (RAM‐BSA C8, 50 × 2.1 mm, Luna, 10 μm, 100 Å) was used in the first dimension in order to exclude macromolecules, while an ACQUITY UPLC BEH C18 (50 × 2.1 mm, 1.7 μm) column was used in the second dimension. Three different channels of selected reaction monitoring (SRM) were used: 350 > 106 m/z, 350 > 160 m/z, and 350 > 192 m/z. The first transition was used for the quantification (higher intensity), and latter two for confirmation. The developed method is simple and requires a total analysis time of only 14 min/sample. The sample treatment involved only a centrifugation step for 20 min. The validated method has been successfully applied to monitor AMP residues in raw milk samples. To our knowledge, this is the first study to report the use of ultrahigh‐performance liquid chromatography (UHPLC) in 2D configuration.  相似文献   

16.
In comprehensive two‐dimensional gas chromatography, two individual separations are coupled by means of a rotating thermal desorption modulator interface. The injection pulse introduced via the interface onto the second column should be as short as possible. Parameters affecting the modulator operation are studied. In the set‐up used in this study, the temperature of the second column can be programmed independently from that of the first column. Optimization of the second‐dimension separation to minimize peak broadening and maximize resolution is discussed and an elegant approach to determine second‐dimension retention times using a non‐constant modulation frequency is demonstrated. The high separation power of the comprehensive system is demonstrated by the analysis of technical and biota samples containing chlorinated biphenyls and toxaphene.  相似文献   

17.
A highly sensitive and selective on‐line two‐dimensional reversed‐phase liquid chromatography/electrospray ionization–tandem mass spectrometry (2D‐LC‐ESI/MS/MS) method was developed and validated to determine rifaximin in rat serum by direct injection. The 2D‐LC‐ESI/MS/MS system consisted of a restricted access media column for trapping proteins as the first dimension and a Waters C18 column as second dimension using 0.1% aqueous acetic acid:acetonitrile as mobile phase in a gradient elution mode. Rifampacin was used as an internal standard. The linear dynamic range was 0.5–10 ng/mL (r2 > 0.998). Acceptable precision and accuracy were obtained over the calibration range. The assay was successfully used in analysis of rat serum to support pharmacokinetic studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
A novel heart‐cutting two‐dimensional liquid chromatography coupled with tandem mass spectrometry method was developed for quantitative analysis of pendimethalin residue in tobacco. The strategy of reversed phase liquid chromatography coupled with another reversed‐phase liquid chromatography was employed for high column efficiency and excellent compatibility of mobile phase. In the first dimensional chromatography, a cyano column with methanol/water as the eluent was applied to separate pendimethalin from thousands of interference components in tobacco. By heart‐cutting technique, which effectively removed interference components, the target compound was cut to the second dimensional C18 column for further separation. The pendimethalin residue was finally determined by the tandem mass spectrometry under multiple reaction monitoring reversed‐phase liquid chromatography mode. Sample pretreatment of the new method was simplified, involving only extraction and filtration. Compared with traditional methodologies, the new method showed fairly high selectivity and sensitivity with almost no matrix interference. The limit of quantitation for pendimethalin was 1.21 ng/mL, whereas the overall recoveries ranged from 95.7 to 103.3%. The new method has been successfully applied to non‐stop measure of 200 real samples, without contamination of ion source. Detection results of the samples agreed well with standard method.  相似文献   

19.
An effective column‐switching counter‐current chromatography (CCC) protocol combining stepwise elution mode was successfully developed for simultaneous and preparative separation of anti‐oxidative components from ethyl acetate extract of traditional Chinese herbal medicine Rubia cordifolia. The column‐switching CCC system was interfaced by a commercial low‐pressure six‐port switching valve equipped with a sample loop, allowing large volume introduction from the first dimension (1st‐D) to the second dimension (2nd‐D). Moreover, to extend the polarity window, three biphasic liquid systems composed of n‐hexane/ethyl acetate/methanol/water (1:2:1:2, 2:3:2:3, 5:6:5:6 v/v) were employed using stepwise elution mode in the 1st‐D. By valve switching technique the whole interested region of 1st‐D could be introduced to second dimension for further separation with the solvent system 5:5:4:6 v/v. Using the present column‐switching CCC protocol, 500 mg of crude R. cordifolia extract were separated, producing milligram‐amounts of four anti‐oxidative components over 90% pure. Structures of purified compounds were identified by 1H and 13C NMR.  相似文献   

20.
A two‐dimensional column‐switching system without sample loop trapping, where two columns were operated via a six‐port switching valve, was employed in the isolation and purification of five isoflavonoids from Rhizoma Belamcandae: tectoridin, iridin, tectorigenin, irigenin and irisflorentin. The introduction of the six‐port switching value, instead of a sample loop, assured 100% recovery from the first dimension to the second, and the injection volumes of the second dimension were not restricted. Two configurations were tested in this study. In the first mode, only one column was used in the second dimension and two ‘heart‐cutting’ fractions were transported to the same second‐dimensional column. In the second mode, two parallel columns were used in the second dimension and two fractions were transported to the two columns. Between the two configurations, the one with two second dimensional columns had double sample size, better resolution and one more purified compound. Both two‐dimensional configurations consumed less solvent with even greater efficiency and shorter cycle time compared with conventional gradient methods. All of the isoflavonoids were isolated at high purities of greater than 95% with yields of above 82%. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号