首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new kind of magnetic N‐doped mesoporous carbon was prepared by the one‐step carbonization of a hybrid precursor (glucose, melamine, and iron chloride) in a N2 atmosphere with a eutectic salt (KCl/ZnCl2) as the porogen. The obtained magnetic N‐doped mesoporous carbon showed excellent characteristics, such as strong magnetic response, high surface area, large pore volume, and abundant π‐electron system, which endow it with a great potential as a magnetic solid‐phase extraction adsorbent. To evaluate its adsorption performance, the magnetic N‐doped mesoporous carbon was used for the extraction of three phthalate esters from soft drink samples followed by high‐performance liquid chromatographic analysis. Under the optimum conditions, the developed method showed a good linearity (1.0–120.0 ng/mL), low limit of detection (0.1–0.3 ng/mL, S/N = 3), and good recoveries (83.2–119.0%) in soft drink samples. The results indicated that the magnetic N‐doped mesoporous carbon has an excellent adsorption capacity for phthalate esters and the present method is simple, accurate, and highly efficient for the extraction and determination of phthalate esters in complex matrix samples.  相似文献   

2.
Metal–organic frameworks‐5 (MOF‐5) was explored as a template to prepare porous carbon due to its high surface area, large pore volume, and permanent nanoscale porosity. Magnetic porous carbon, Co@MOF‐5‐C, was fabricated by the one‐step direct carbonization of Co‐doped MOF‐5. After carbonization, the magnetic cobalt nanoparticles are well dispersed in the porous carbon matrix, and Co@MOF‐5‐C displays strong magnetism (with the saturation magnetization intensity of 70.17emu/g), high‐specific surface area, and large pore volume. To evaluate its extraction performance, the Co@MOF‐5‐C was applied as an adsorbent for the magnetic solid‐phase extraction of endocrine disrupting chemicals, followed by their analysis with high‐performance liquid chromatography. The developed method exhibits a good linear response in the range of 0.5–100 ng/mL for pond water and 1.0–100 ng/mL for juice samples. The limits of detection (S/N  = 3) for the analytes were in the range of 0.1–0.2 ng/mL.  相似文献   

3.
For the first time, alpha‐fetoprotein (AFP) quantification as an early test for liver cancer diagnosis competing with other interfering analytes and factors based on a novel nano‐magnetic metal–organic framework (MOF) was investigated. The novel nano‐magnetic MOF was synthesized via a simple preparation method, and characterized using various techniques. The X‐ray photoelectron spectrum of the nano‐magnetic MOF shows Cu 2p, O 1s, N 1s and C 1s peaks that evidence the presence of these elements in the sample without any impurities. Scanning and transmission electron microscopy images show the nano‐magnetic MOF with average size between 22 and 43 nm. The results of a photoluminescence study show that the nano‐magnetic MOF exhibits strong emission at 418 nm after excitation at 354 nm. Moreover, a Stern–Völmer graph shows a linear calibration curve over an AFP concentration range 1.0–520 ng ml?1 with a correlation coefficient of 0.997, detection limit of 1.18 ng ml?1 and quantitation limit of 3.58 ng ml?1. According to the marked quenching of the photoluminescence intensity of the nano‐magnetic MOF using various concentrations of AFP, it was successfully used as a biosensor for AFP in serum samples collected from hepatitis patients in addition to healthy males and females. The quenching mechanism was well studied, and found to be a dynamic type. The present work offers a simple, low‐cost, room‐temperature and rapid technique, being non‐time‐consuming, highly accurate, selective and highly sensitive compared with most published methods.  相似文献   

4.
Interaction between adsorbed hydrogen and the coordinatively unsaturated Mg2+ and Co2+ cationic centres in Mg‐MOF‐74 and Co‐MOF‐74, respectively, was studied by means of variable‐temperature infrared (VTIR) spectroscopy. Perturbation of the H2 molecule by the cationic adsorbing centre renders the H? H stretching mode IR‐active at 4088 and 4043 cm?1 for Mg‐MOF‐74 and Co‐MOF‐74, respectively. Simultaneous measurement of integrated IR absorbance and hydrogen equilibrium pressure for spectra taken over the temperature range of 79–95 K allowed standard adsorption enthalpy and entropy to be determined. Mg‐MOF‐74 showed ΔH0=?9.4 kJ mol?1 and ΔS0=?120 J mol?1 K?1, whereas for Co‐MOF‐74 the corresponding values of ΔH0=?11.2 kJ mol?1 and ΔS0=?130 J mol?1 K?1 were obtained. The observed positive correlation between standard adsorption enthalpy and entropy is discussed in the broader context of corresponding data for hydrogen adsorption on cation‐exchanged zeolites, with a focus on the resulting implications for hydrogen storage and delivering.  相似文献   

5.
A poly(4‐vinylpridine‐co‐ethylene glycol dimethacrylate) monolith was synthesized in a capillary and constructed as a concentrator for the in‐line polymeric monolith microextraction coupling with capillary electrophoresis. The integrated system was then used for the simultaneous determination of five trace phenols (2‐nitrophenol, 3‐nitrophenol, 4‐nitrophenol, 2‐chlorophenol, and 2,4‐dichlorophenol) in water samples. The experimental parameters for in‐line solid‐phase extraction, such as composition and volume of the elution plug, pH of sample solution, and the time for sample loading were optimized. The sensitivity for the mixture of phenols (2‐nitrophenol, 3‐nitrophenol, 4‐nitrophenol, 2‐chlorophenol, and 2,4‐dichlorophenol) enhanced to 615–2222 folds at the optimum condition was compared to the sensitivity for a normal hydrodynamic injection in capillary electrophoresis. Linearity ranged from concentration of 10–500 ng mL?1(R2 > 0.999) for all five phenols with the detection limits of 1.3–3.3 ng mL?1. In tap, snow and Yangtze River water spiked with 20 ng mL?1 and 200 ng mL?1, respectively, the recoveries of 84–105% were obtained. It has been demonstrated that this work has great potential for the analysis of phenols in genuine water samples.  相似文献   

6.
A quick and inexpensive validated method, based on sample treatment by liquid–liquid microextraction followed by liquid chromatography (LC) coupled with ultraviolet tandem fluorescence detection is proposed for the determination of 15 multiclass pollutants both in serum and in saliva, as a simple and easy to draw matrix. The method was set up and validated according to European guidelines. The compounds of interest include some endocrine‐disrupting chemicals (i.e. bisphenol A, bisphenol B, bisphenol E, bisphenol F, bisphenol AF, bisphenol A diglycidyl ether, bisphenol M, diethylhexyl phthalate, monoethylhexyl phthalate, triclosan and 4‐nonylphenol), as well as other pollutants belonging to the class of volatile organic compounds (2‐chlorophenol, 1,2 dichlorobenzene, 1,2,4,5‐tetrachlorobenzene). The limits of quantifications ranged from 2.28 × 10?3 μg mL?1 (bisphenol A diglycidyl ether) to 6.29 μg mL?1 (diethylhexyl phthalate), while those of detection ranged from 0.068 × 10?3 μg mL?1 (bisphenol A diglycidyl ether) to 1.031 μg mL?1 (diethylhexyl phthalate). To test method suitability, it was applied to real saliva and serum samples of healthy human volunteers and was found to meet the demands of the laboratories handling simple and relatively inexpensive equipment for screening oriented at rapid and reliable contamination assessment of a population.  相似文献   

7.
A signal‐enhanced immunosensor has been developed by self‐assembling Au NPs onto a ferrocene‐branched poly(allylamine)/multiwalled carbon nanotubes (PAA‐Fc/MWNTs) modified electrode for the sensitive determination of hepatitis B surface antigen (HBsAg) as a model protein. The formation of PAA‐Fc/MWNTs composite not only effectively avoided the leakage of Fc and retained its electrochemical activity, but also enhanced the conductivity and charge‐transport properties of the composite. Further adsorption of Au NPs into the PAA matrix provided both the interactive sites for the immobilization of hepatitis B surface antibody (HBsAb) and a favorable microenvironment to maintain its activity. Tests performed with this immunosensor showed a specific response to HBsAg in the range of 0.1–350.0 ng mL?1 with a detection limit of 0.03 ng mL?1.  相似文献   

8.
A facile synthesis of partially hydroxy‐modified MOF‐5 and its improved H2‐adsorption capacity by lithium doping are reported. The reaction of Zn(NO3)2 ? 6 H2O with a mixture of terephthalic acid (H2BDC) and 2‐hydroxyterephthalic acid (H2BDC‐OH) in DMF gave hydroxy‐modified MOF‐5 (MOF‐5‐OH‐x), in which the molar fraction (x) of BDC‐OH2? was up to 0.54 of the whole ligand. The MOF‐5‐OH‐x frameworks had high BET surface areas (about 3300 m2 g?1), which were comparable to that of MOF‐5. We suggest that the MOF‐5‐OH‐x frameworks are formed by the secondary growth of BDC2?‐rich MOF‐5 seed crystals, which are nucleated during the early stage of the reaction. Subsequent Li doping into MOF‐5‐OH‐x results in increased H2 uptake at 77 K and 0.1 MPa from 1.23 to 1.39 wt. % and an increased isosteric heat of H2 adsorption from 5.1–4.2 kJ mol?1 to 5.5–4.4 kJ mol?1.  相似文献   

9.
Water contaminated with heavy metals has been identified as a significant threat to human health. Therefore, the development of safe and rapid water‐treatment techniques is necessary. We have synthesized an eco‐friendly γ‐cyclodextrin metal–organic framework (MOF)‐based nanoporous carbon (γ‐CD MOF‐NPC) material, conducted a comprehensive characterization of it, and found its rapid and effective CdII‐removal capacity. The γ‐CD MOF‐NPC could effectively sequester a majority of cadmium ions within one minute, and it still demonstrated excellent adsorption ability under various conditions, including different pH, adsorbent dosage, and coexistent ions. The maximum adsorption capacity was calculated to be 140.85 mg g?1 by means of the Langmuir model. The adsorption was primarily due to the effect of ion exchange of oxygen‐containing functional groups, as determined by studying the ζ potential and Fourier transform infrared spectroscopy. Flow‐through experiments further proved the rapid CdII‐removal capacity and potential of the practical application of γ‐CD MOF‐NPC in water treatment according to the cytotoxic data.  相似文献   

10.
A method for rapid identification and quantification of phthalate plasticizers in beverages was developed. A number of 15 phthalate plasticizers which covered all the phthalates concerned in the US Consumer Product Safety Improvement Act (CPSIA), European Union legislations and Chinese national standards (GB) were analyzed. By a combined solid‐phase micro‐extraction (SPME) and direct analysis in real time mass spectrometry (DART‐MS) approach, phthalates at sub‐ng·mL?1 levels can be qualitatively and quantitatively analyzed in a short time. The use of ultrahigh‐resolving power and the accurate mass measurement capacity naturally provided by Fourier transform ion cyclotron resonance mass spectrometry (FT‐ICR‐MS) minimizes the matrix interferences and thus enables the evaluation of phthalates in a complex matrix without extensive sample handlings or preparations. The limits of quantification (LOQs) were estimated to be at 0.3–5.0 ng·mL?1, lower than the Maximum Residue Limit (MRL) regulated by the European Union legislations (2007/19/EC) in foods, beverages, food packaging and toys (0.3–30 ng·mL?1). This rapid and easy‐to‐use SPME‐DART‐FT‐ICR‐MS method provided a relatively high‐throughput and powerful analytical approach for quick testing and screening phthalates in beverages and water samples to ensure food safety.  相似文献   

11.
A sensitive and simple solid‐phase preconcentration procedure for the determination of trace amount of lead by flame atomic absorption spectrometry (FAAS) is developed. The method is based on the adsorption of Pb2+ on the column of fine grinded eucalyptus stem adsorbent, elution of the column by nitric acid and subsequent determination by FAAS. The effect of different variables such as pH, eluent type, flow rate and interfering ions on the recovery of the analyte was investigated and optimum conditions were established. The adsorption of lead onto fine grinded eucalyptus stem can formally be described by a Langmuir equation with a maximum adsorption capacity of 4.49 mg g?1. A preconcentration factor of 50 was achieved using the optimum conditions. The calibration graph was linear in the range 10–125 ng mL?1 of lead in the initial solution with r = 0.9982. The limit of detection based on 3Sb criterion was 4.5 ng mL?1 and the relative standard deviation for eight replicate measurements of 30 and 80 ng mL?1 of iron was 3.6 and 2.8%, respectively. The method was successfully applied to the determination of lead added to well, tap and wastewater samples.  相似文献   

12.
The aim of this work was to develop a method for the clean‐up and preconcentration of warfarin from biological sample employing a new molecularly imprinted polymer (MIP) as a selective adsorbent for solid‐phase extraction (SPE). This MIP was synthesized using warfarin as a template, pyrrole as a functional monomer and vinyl triethoxysilane as a cross‐linker. The molar ratio of 1:4:20 (template–functional monomer–cross‐linker) showed the best results. Nonimprinted polymers (NIPs) were prepared and treated with the same method, but in the absence of warfarin. The prepared polymer was characterized by Fourier transmission infrared spectrometry and scanning electron microscopy. An adsorption process (SPE) for the removal of warfarin using the fabricated MIPs and NIPs was evaluated under various conditions. Effective parameters on warfarin extraction, for example, type and volume of elution solvent, pH of sample solution, breakthrough volume and maximum loading capacity, were studied. The limits of detection were in the range of 0.0035–0.0050 µg mL?1. Linearity of the method was determined in the range of 0.0165–10.0000 µg mL?1 for plasma and 0.0115–10.0000 µg mL?1 for urine with coefficients of determination (R2) ranging from 0.9975 to 0.9985. The recoveries for plasma and urine samples were >95%. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

13.
A three‐dimensional graphene was synthesized through a hydrothermal reaction of graphene oxide with phytic acid. The microstructure and morphology of the phytic acid induced three‐dimensional graphene were investigated by nitrogen adsorption–desorption isotherms, scanning electron microscopy, and transmission electron microscopy. With a large surface area and three‐dimensional structure, the graphene was used as the solid‐phase extraction adsorbent for the extraction of phthalate esters from bottled water and sports beverage samples before high‐performance liquid chromatographic analysis. The results indicated that the graphene was efficient for the solid‐phase extraction of phthalate esters. The limits of detection (S/N = 3) of the method for the analytes were 0.02–0.03 ng/mL for the water samples and 0.03–0.15 ng/mL for the sports beverage sample. The limits of quantitation (S/N = 9) for the analytes were 0.06–0.09 ng/mL for water samples and 0.09–0.45 ng/mL for sports beverage sample. The calibration curves for the phthalate esters by the method had a good linearity from 0.1 to 80.0 ng/mL with correlation coefficients larger than 0.9997. The recoveries of the analytes for the method fell in the range of 86.7–116.2% with the relative standard deviations between 1.5 and 6.8%.  相似文献   

14.
The first example of an interpenetrated methyl‐modified MOF‐5 with the formula Zn4O(DMBDC)3(DMF)2, where DMBDC2? is 2,5‐dimethylbenzene‐1,4‐dicarboxylate and DMF is N,N‐dimethylformamide (henceforth denoted as Me2MOF‐5‐int ), namely, poly[tris(μ4‐2,5‐dimethylbenzene‐1,4‐dicarboxylato)bis(N,N‐dimethylformamide)‐μ4‐oxido‐tetrazinc(II)], [Zn4(C10H8O4)3O(C3H7NO)2]n, has been obtained from a solvothermal synthesis of 2,5‐dimethylbenzene‐1,4‐dicarboxylic acid and Zn(NO3)2·6H2O in DMF. A systematic study revealed that the choice of solvent is of critical importance for the synthesis of phase‐pure Me2MOF‐5‐int , which was thoroughly characterized by single‐crystal and powder X‐ray diffraction (PXRD), as well as by gas‐adsorption analyses. The Brunauer–Emmett–Teller surface area of Me2MOF‐5‐int (660 m2 g?1), determined by N2 adsorption, is much lower than that of nonpenetrated Me2MOF‐5 (2420 m2 g?1). However, Me2MOF‐5‐int displays an H2 uptake capacity of 1.26 wt% at 77 K and 1.0 bar, which is comparable to that of non‐interpenetrated Me2MOF‐5 (1.51 wt%).  相似文献   

15.
目的:建立刺激胰岛素分泌的新型降糖药物(-)-2 (S)-苄基-4-酮-4-(顺式-全氢化异吲哚-2-基)丁酸钙对映体的HPLC拆分方法。方法:采用Sumichiral OA-3300手性柱(250 × 4.6 mm I.D., 5 μm), 柱温35℃,以0.05 mol·L-1醋酸铵的甲醇溶液为流动相,检测波长为210 nm。结果:本品两对映体在22分钟内实现良好分离,分离度达3以上,S-异构体分别在0.028 ~ 5.6 μg mL-1和0.03 ~ 6.0 μg mL-1范围内线性关系良好,回归方程分别为:Y=1.32×103x-2.54 (r=0.9997)和Y=1.15×103x-1.78 (r=0.9998),最低检测限分别为0.15 ng和0.10 ng,方法精密度RSD低于1.0% (n=5)。结论:建立的对映体分离方法可用于本品光学异构体的质量控制。  相似文献   

16.
《Electroanalysis》2005,17(22):2032-2036
We found that bis(thiophenal) pyridine‐2,6‐diamine (BPD) can be used as an excellent ion carrier to prepare a gadolinium‐selective PVC‐based membrane sensor. The use of oleic acid (OA) and potassium tetrakis(p‐chlorophenyl borate)(KTKpClPB), as anionic additives, and dibutyl phthalate (DBP), acetophenone (AP) and nitrobenzene (NB), as plasticizing solvent mediators was investigated. The best performance was observed with a membrane having the composition of 30% PVC; 62% BA; 5% BPD; and 3% KTKpClPB. The resulting sensor works well over a relatively wide concentration range (1.0×10?6–1.0×10?1 M) with a Nernstian slope of 19.4±0.4 mV per decade of gadolinium activity over a wide pH range (3.5–8.0). The limit of detection of the sensor is 7.0×10?7 M (ca. 110 ng mL?1). The proposed electrode shows excellent discriminating ability toward gadolinium ions with regard to common alkali, alkaline earth, transition, heavy metal ions, and specially, lanthanide ions. The proposed sensor was applied as an indicator electrode for titration of gadolinium ions with EDTA.  相似文献   

17.
A solid‐phase extraction method for preconcentration of silver and consequent determination by atomic absorption spectrometry is described. The method is based on the adsorption of silver on naphthalene modified with dithizone in a column. The adsorbed silver is eluted from the column with a thiourea solution and determined by flame atomic absorption spectrometry. The adsorption conditions including pH, reagent concentration, eluent volume, flow rate and interfering ions were investigated. The calibration graph was linear in the range 10–1000 ng mL?1 of Ag in the initial solution with r = 0.9998. The limit of detection based on 3Sb was 3.9 ng mL?1. The relative standard deviation for ten replicate measurements of 40 and 600 ng mL?1 of Ag was 4.4% and 0.9%, respectively. The method was applied to the determination of silver in mineral, radiology film and wound dressing samples.  相似文献   

18.
A novel magnetic porous carbon derived from a bimetallic metal–organic framework, Zn/Co‐MPC, was prepared by introducing cobalt into ZIF‐8. Magnetic porous carbon that possesses magnetic properties and a large specific surface area was firstly fabricated by the direct carbonization of Zn/Co‐ZIF‐8. The prepared magnetic porous carbon material was characterized by scanning electron microscopy, transmission electron microscopy, powder X‐ray diffraction, N2 adsorption, and vibrating sample magnetometry. The prepared magnetic porous carbon was used as a magnetic solid‐phase extraction adsorbent for the enrichment of chlorophenols from water and honey tea samples before high‐performance liquid chromatography analysis. Several experimental parameters that could influence the extraction efficiency were investigated and optimized. Under the optimum conditions, good linearities (r > 0.9957) for all calibration curves were obtained with low limits of detection, which are in the range of 0.1–0.2 ng mL?1 for all the analytes. The results showed that the prepared magnetic porous carbon had an excellent adsorption capability toward the target analytes.  相似文献   

19.
The method of liquid‐phase microextraction assisted with voltage was developed and applied on determination of sulfonamides in water samples. Four analytes, such as sulfamethazine, sulfathiazole, sulfadimethoxine, and sulfamethoxazole were extracted from a sample solution at pH 4.5 through a polypropylene membrane of immobilized with 2‐octanone, and then into 25 μL of the acceptor phase of 10 mM sodium hydroxide, and applied voltage of 100 V. Subsequently, the acceptor solution was directly subjected to analysis by LC‐MS or capillary zone electrophoresis. Linearity was obtained in the range of 1.0–25.0 ng mL?1 with R2 > 0.992 in LC‐MS, and 50–1000 ng mL?1 with R2 > 0.995 in capillary zone electrophoresis. The development of VA‐LPME was also applied in analysis of sulfonamides in water samples to evaluate its practical applicability.  相似文献   

20.
In this work, magnetic nanoporous carbon with high surface area and ordered structure was synthesized using cheap commercial silica gel as template and sucrose as the carbon source. The prepared magnetic nanoporous carbon was firstly used as an adsorbent for the extraction of phthalate esters, including diethyl phthalate, diallyl phthalate, and di‐n‐propyl‐phthalate, from lake water and aloe juice samples. Several parameters that could affect the extraction efficiency were optimized. Under the optimum conditions, the limit of detection of the method (S/N = 3) was 0.10 ng/mL for water sample and 0.20 ng/mL for aloe juice sample. The linearity was observed over the concentration range of 0.50–150.0 and 1.0–200.0 ng/mL for water and aloe juice samples, respectively. The results showed that the magnetic nanoporous carbon has a high adsorptive capability toward the target phthalate esters in water and aloe juice samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号