首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ionic liquids have been widely used as green alternative mobile phase additives to shield the residuals silanols groups and modify the stationary/mobile phase HPLC systems. The present study aimed to evaluate the performance of the ionic liquid 1‐ethyl‐3‐methylimidazolium tetrafluoroborate ([EMIM][BF4]) in producing extrapolated logkw indices suitable to substitute for octanol–water logP or logD values. The effect of [EMIM][BF4] was investigated for a set of basic and neutral drugs using two different columns, BDS and ABZ+. [EMIM][BF4] was added simply alone or in combination with n‐octanol and was compared with the conventional masking agent n‐decylamine. [EMIM][BF4] reduced the retention by suppressing silanophilic interactions, althoug to a lower extent than n‐decylamine. Addition of n‐octanol further decreased the retention by shielding silanol sites on BDS and/or interacting with polar groups through hydrogen bonding on ABZ+. Logkw/logD7.4 relationships proved moderate compared with those derived upon addition of n‐decylamine. They were considerably improved upon the introduction of protonated fraction F+ in the correlation, reflecting ion pair formation between the chaotropic anion [BF4] and the protonated basic compounds. In this aspect, the ionic liquid [EMIM][BF4], although efficient as a masking agent, cannot be recommended as mobile phase additive to reproduce octanol–water partitioning. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

2.
A novel low‐density solvent‐based vortex‐assisted surfactant‐enhanced‐emulsification liquid–liquid microextraction with the solidification of floating organic droplet method coupled with high‐performance liquid chromatography was developed for the determination of 3,5,6‐trichloro‐2‐pyridinol, phoxim and chlorpyrifos‐methyl in water samples. In this method, the addition of a surfactant could enhance the speed of the mass transfer from the sample solution into the extraction solvent. The extraction solvent could be dispersed into the aqueous by the vortex process. The main parameters affecting the extraction efficiency were investigated and the optimum conditions were established as follows: 80 μL 1‐undecanol as extraction solvent, 0.2 mmol/L of Triton X‐114 selected as the surfactant, the vortex time was fixed at 60 s with the vortex agitator set at 3000 rpm, the concentration of acetic acid in sample solution was 0.4% v/v and 1.0 g addition of NaCl. Under the optimum conditions, the enrichment factors were from 172 to 186 for the three analytes. The linear ranges were from 0.5 to 500 μg/L with a coefficient of determination (r2) of between 0.9991 and 0.9995. Limits of detections were varied between 0.05 and 0.12 μg/L. The relative standard deviations (n = 6) ranged from 0.26 to 2.62%.  相似文献   

3.
In the present study, a novel configuration of liquid‐phase microextraction was proposed, in which a magnetic stirrer with a groove was used as the extractant phase holder. It was termed as magnetic stirrer liquid‐phase microextraction. In this way, the stability of the organic solvent was much improved under high stirring speed; the extraction efficiency was enhanced due to the enormously enlarged contact area between the organic solvent and aqueous phase. The extraction performance of the magnetic stirrer liquid‐phase microextraction was studied using chlorobenzenes as the probe analytes. A wide linearity range (20 pg/mL to 200 ng/mL) with a satisfactory linearity coefficient (r2 > 0.998) was obtained. Limits of detection ranged from 9.0 to 12.0 pg/mL. Good reproducibility was achieved with intra‐ and inter‐day relative standard deviations <4.8%. The proposed magnetic stirrer liquid‐phase microextraction was simple, environmentally friendly and efficient; compared to single‐drop microextraction, it had obvious advantages in terms of reproducibility and extraction efficiency. It is a promising miniaturized liquid‐phase technology for real applications.  相似文献   

4.
The advantageous effect of n‐octanol as a mobile phase additive for lipophilicity assessment of structurally diverse acidic drugs both in the neutral and ionized form was explored. Two RP C18 columns, ABZ+ and Aquasil, were used for the determination of logkw indices, and the results were compared with those previously reported on a base‐deactivated silica column. At pH 2.5, the use of n‐octanol‐saturated buffer as the mobile phase aqueous component led to high‐quality 1:1 correlation between logkw and logP for the ABZ+ column, while inferior statistics were obtained for Aquasil. At physiological pH, the correlations were significantly improved if strongly ionized acidic drugs were treated separately from weakly ionized ones. In the latter case, 1:1 correlations between logD7.4 and logkwoct indices were obtained in the presence of 0.25% n‐octanol. Concerning strongly ionized compounds, adequate correlations were established under the same conditions; however, slopes were significantly lower than unity, while large negative intercepts were obtained. According to the absolute difference (diff = logD7.4–logkw) pattern, base‐deactivated silica showed a better performance than ABZ+, however, the latter seems more efficient for the lipophilicity assessment of highly lipophilic acidic compounds. Aquasil may be the column of choice if logD7.4<3 with the limitation, however, that very hydrophilic compounds cannot be measured.  相似文献   

5.
A novel microextraction method based on vortex‐ and CO2‐assisted liquid–liquid microextraction with salt addition for the isolation of furanic compounds (5‐hydroxymethyl‐2‐furaldehyde, 5‐methyl‐2‐furaldehyde, 2‐furaldehyde, 3‐furaldehyde, 2‐furoic and 3‐furoic acids) was developed. Purging the sample with CO2 was applied after vortexing to enhance the phase separation and mass transfer of the analytes. The optimum extraction conditions were: extraction solvent (volume), propyl acetate (125 μL); sample pH, 2.4; vortexing time, 45 s; salt concentration, 25% w/v and purging time, 5 min. The analytes were separated using an ODS Hypersil C18 column (250×4.6 mm i.d, 5 μm) under gradient flow. The proposed method showed good linearities (r2 >0.999), low detection limits (0.08–1.9 μg/L) and good recoveries (80.7–122%). The validated method was successfully applied for the determination of the furanic compounds in concentrated juice (mango, date, orange, pomegranate, roselle, mangosteen and soursop) and dried fruit (prune, date and apricot paste) samples.  相似文献   

6.
A novel graphene‐sensitized microporous membrane/solvent microextraction method named microporous membrane/graphene/solvent synergistic microextraction, coupled with high‐performance liquid chromatography and UV detection, was developed and introduced for the extraction and determination of three cinnamic acid derivatives in Rhizoma Typhonii. Several factors affecting performance were investigated and optimized, including the types of graphene and extraction solvent, concentration of graphene dispersed in octanol, sample phase pH, ionic strength, stirring rate, extraction time, extraction temperature, and sample volume. Under optimized conditions, the enrichment factors of cinnamic acid derivatives ranged from 75 to 269. Good linearities were obtained from 0.01 to 10 μg/mL for all analytes with regression coefficients between 0.9927 and 0.9994. The limits of quantification were <1 ng/mL, and satisfactory recoveries (99–104%) and precision (1.1–10.8%) were also achieved. The synergistic microextraction mechanism based on graphene sensitization was analyzed and described. The experimental results showed that the method was simple, sensitive, practical, and effective for the preconcentration and determination of cinnamic acid derivatives in Rhizoma Typhonii.  相似文献   

7.
The solubilities of 1alkyl‐3‐methylimidazolium chloride, [Cnmim][Cl], where n=4, 8, 10, and 12, in 1octanol and water have been measured by a dynamic method in the temperature range from 270 to 370 K. The solubility data was used to calculate the 1octanol/water partition coefficients as a function of temperature and alkyl substituent. The melting point, enthalpies of fusion, and enthalpies of solid–solid phase transitions were determined by differential scanning calorimetry, DSC. The solubility of [Cnmim][Cl], where n=10 or 12 in 1octanol is comparable and higher than that of [C4mim][Cl] in 1octanol. Liquid 1n‐octyl‐3‐methylimidazolium chloride, [C8mim][Cl], is not miscible with 1octanol and water, consequently, the liquid–liquid equilibrium, LLE was measured in this system. The differences between the solubilities in water for n=4 and 12 are shown only in α1 and γ1 solid crystalline phases. Additionally, the immiscibility region was observed for the higher concentration of [C10mim][Cl] in water. The intermolecular solute–solvent interaction of 1butyl‐3‐methylimidazolium chloride with water is higher than for other 1alkyl‐3‐methylimidazolium chlorides. The data was correlated by means of the UNIQUAC ASM and two modified NRTL equations utilizing parameters derived from the solid–liquid equilibrium, SLE. The root‐mean‐square deviations of the solubility temperatures for all calculated data are from 1.8 to 7 K and depend on the particular equation used. In the calculations, the existence of two solid–solid first‐order phase transitions in [C12mim][Cl] has also been taken into consideration. Experimental partition coefficients (log P) are negative at three temperatures; this is evidence for the possible use of these ionic liquids as green solvents.  相似文献   

8.
A sensitive method based on ionic liquid for single‐drop liquid microextraction coupled with HPLC‐UV was developed for the determination of carbonyl compounds in environmental waters using 1‐octyl‐3‐methylimidazolium hexafluorophosphate [C8min][PF6] as extraction solvent and 2,4‐dinitrophenylhydrazine as derivatizing agent. The extraction parameters affecting the enrichment factors such as solvent volume, pH, extraction time and salt concentration were investigated. A homemade funnel form polytetrafluoroethylene sleeve was fixed at the tip of the syringe needle and this allowed the use of 10 μL drop of ionic liquid for direct immersion extraction. Under the optimal conditions, the remarkable enrichment factors up to 150‐fold were obtained depending on the target analytes. The method has been validated when rectilinear relationship was obtained between the concentrations of analytes and peak area in the range of 5–100 ng/mL, the correlation coefficients were from 0.995 to 0.998, and the limit of detection was in the range of 0.04–2.03 ng/mL. The method was applied to monitor the concentration of carbonyl compounds in environmental waters with spiked recovery in the range of 84.2–106.9%.  相似文献   

9.
In this work we seek clues to select the appropriate dispersive liquid–liquid microextraction mode for extracting three categories of compounds. For this purpose, three common dispersive liquid–liquid microextraction modes were compared under optimized conditions. Traditional dispersive liquid–liquid microextraction, in situ ionic liquid dispersive liquid–liquid microextraction, and conventional ionic liquid dispersive liquid–liquid microextraction using chloroform, 1‐butyl‐3‐methylimidazolium tetrafluoroborate, and 1‐hexyl‐3‐methylimidazolium hexafluorophosphate as the extraction solvent, respectively, were considered in this work. Phenolic, neutral aromatic, and amino compounds (each category included six members) were studied as analytes. The analytes in the extracts were determined by high‐performance liquid chromatography with UV detection. For the analytes with polar functionalities, the in situ ionic liquid dispersive liquid–liquid microextraction mode mostly led to better results. In contrast, for neutral hydrocarbons without polar functionalities, traditional dispersive liquid–liquid microextraction using chloroform produced better results. In this case, where dispersion forces were the dominant interactions in the extraction, the refractive index of solvent and analyte predicted the extraction performance better than the octanol/water partition coefficient. It was also revealed that none of the methods were successful in extracting hydrophilic analytes (compounds with the log octanol/water partition coefficient <2). The results of this study could be helpful in selecting a dispersive liquid–liquid microextraction mode for the extraction of various groups of compounds.  相似文献   

10.
A three‐phase hollow fiber liquid‐phase microextraction method coupled with CE was developed and used for the determination of partition coefficients and analysis of selected nitrophenols in water samples. The selected nitrophenols were extracted from 14 mL of aqueous solution (donor solution) with the pH adjusted to pH 3 into an organic phase (1‐octanol) immobilized in the pores of the hollow fiber and finally backextracted into 40.0 μL of the acceptor phase (NaOH) at pH 12.0 located inside the lumen of the hollow fiber. The extractions were carried out under the following optimum conditions: donor solution, 0.05 M H3PO4, pH 3.0; organic solvent, 1‐octanol; acceptor solution, 40 μL of 0.1 M NaOH, pH 12.0; agitation rate, 1050 rpm; extraction time, 15 min. Under optimized conditions, the calibration curves for the analytes were linear in the range of 0.05–0.30 mg/L with r2>0.9900 and LODs were in the range of 0.01–0.04 mg/L with RSDs of 1.25–2.32%. Excellent enrichment factors of up to 398‐folds were obtained. It was found that the partition coefficient (Ka/d) values were high for 2‐nitrophenol, 3‐nitrophenol, 4‐nitrophenol, 2,4‐dinitrophenol and 2,6‐dinitrophenol and that the individual partition coefficients (Korg/d and Ka/org) promoted efficient simultaneous extraction from the donor through the organic phase and further into the acceptor phase. The developed method was successfully applied for the analysis of water samples.  相似文献   

11.
A novel oil‐in‐salt liquid‐phase microextraction was developed and introduced for the extraction and concentration of the trace levels of active alkaloids in Coptis chinensis prior to being analyzed by high‐performance liquid chromatography with ultraviolet detection. Also, the oil‐in‐salt extraction mechanism was analyzed, the enrichment factor and extraction recovery were redefined, and the proposed method was compared with other methods. In the approach, the mixed solvent of pentanol/octanol (6:4, v/v) and NaCl (20% w/v) are immobilized on the permutite surface in turn to form oil‐in‐salt double membranes, through which the target analytes can be molecularized though salting‐out effect and be extracted by organic solvent. The main parameters affecting the approach were investigated and optimized. Under the optimized conditions, the enrichment factors of the analytes were 30–117, the linear ranges were 0.002–2 μg/mL for jatrorrhizine, coptisine, and palmatine, and 0.001–3 μg/mL for berberine (r 2 ≥ 0.9923). The limits of detection were less than 1 ng/mL. Satisfactory recoveries (84.3%–120.3%) and precision (0.9%–7.5%) were also obtained. These results confirm that the approach is a simple and reliable sample pretreatment procedure and allows for the quantification of active alkaloids in C. chinensis at actual concentration levels.  相似文献   

12.
A novel supramolecular solvent‐based microextraction followed by high‐performance liquid chromatography with ultraviolet detection method has been developed for the extraction and determination of two pyrethroid analytes, cyhalothrin and fenvalerate, in water and soil samples. The liquid–liquid‐phase separation of surfactants has been used in analytical extraction. The surfactant‐rich phase is a nano‐structured liquid, recently named as a supramolecular solvent, generated from the amphiphiles. The alkyl carboxylic acid based supramolecular solvents were introduced before. Coacervates made up of gemini surfactant, consisting of two amphiphilic moieties, were first used as solvent. The effective parameters on extraction (i.e., type of organic solvent, the amount of surfactant and volume of tetrahydrofuran, sample solution pH, salt addition, ultrasonic and centrifugation time) were investigated and optimized. Under the optimum conditions, preconcentration factors of 110 and 145 were obtained for the analytes. The linearity was 0.5–200.0 μg/L with the correlation of determination of (R2) ≥ 0.9984. The limit of detection of the method was (S/N = 3) 0.2 μg/L, and precisions in the range of 6.3–10.3% (RSDs, n = 5) were obtained. This method has been successfully applied to analyze real samples, and good recoveries in the range of 101.2–108.8% were obtained.  相似文献   

13.
A novel microextraction method, termed microwave‐assisted ionic liquid/ionic liquid dispersive liquid–liquid microextraction, has been developed for the rapid enrichment and analysis of triazine herbicides in fruit juice samples by high‐performance liquid chromatography. Instead of using hazardous organic solvents, two kinds of ionic liquids, a hydrophobic ionic liquid (1‐hexyl‐3‐methylimidazolium hexafluorophosphate) and a hydrophilic ionic liquid (1‐butyl‐3‐methylimidazolium tetrafluoroborate), were used as the extraction solvent and dispersion agent, respectively, in this method. The extraction procedure was induced by the formation of cloudy solution, which was composed of fine drops of 1‐hexyl‐3‐methylimidazolium hexafluorophosphate dispersed entirely into sample solution with the help of 1‐butyl‐3‐methylimidazolium tetrafluoroborate. In addition, an ion‐pairing agent (NH4PF6) was introduced to improve recoveries of the ionic liquid phase. Several experimental parameters that might affect the extraction efficiency were investigated. Under the optimum experimental conditions, the linearity for determining the analytes was in the range of 5.00–250.00 μg/L, with the correlation coefficients of 0.9982–0.9997. The practical application of this effective and green method is demonstrated by the successful analysis of triazine herbicides in four juice samples, with satisfactory recoveries (76.7–105.7%) and relative standard deviations (lower than 6.6%). In general, this method is fast, effective, and robust to determine triazine herbicides in juice samples.  相似文献   

14.
A rapid, effective method applying vortex‐assisted liquid–liquid microextraction before ultra‐high performance liquid chromatography with mass spectrometry and evaporative light scattering detection was developed for the analysis of four cucurbitane triterpenoids (momordicoside L, momordicoside K, momordicoside F2, and 3β,7β,25‐trihydroxy cucurbita‐5,23(E )‐dien‐19‐al) in bitter melon juices. Variables affecting the extraction efficiency including different extraction solvents, volume of extraction solvent, salt amount, acid condition, vortex speed and time were optimized thoroughly. Under the optimum conditions, precision was determined by the intra‐ and inter‐day tests in a range of 1.1–5.7% and 2.9–4.0% (RSD), respectively, with recoveries between 95.7 and 106.1%. The calibration curves showed good linearity with square correlation coefficient of 0.9936–0.9991 (evaporative light scattering detection) and 0.9858–0.9989 (MS). The detection limits ranged from 0.8–1.9 ng/mL (MS) to 3–10 ng/mL (evaporative light scattering detection) for these compounds. Enrichment factors of four target compounds were between 27 and 63 times. The proposed method was also used to determine the apparent solvent/water partition coefficients of analytes within the range of 53–120. The developed method can effectively enrich and quantify cucurbitane triterpenoids from bitter melon drinks.  相似文献   

15.
A novel manual‐shaking‐ and ultrasound‐assisted surfactant‐enhanced emulsification microextraction method was developed for the determination of three fungicides in juice samples. In this method, the ionic liquid, 1‐ethyl‐3‐methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, instead of a volatile organic solvent was used as the extraction solvent. The surfactant, NP‐10, was used as an emulsifier to enhance the dispersion of the water‐immiscible ionic liquid into an aqueous phase, which accelerated the mass transfer of the analytes. Organic dispersive solvent typically required in common dispersive liquid–liquid microextraction methods was not necessary. In addition, manual shaking for 15 s before ultrasound to preliminarily mix the extraction solvent and the aqueous sample could greatly shorten the time for dispersing the ionic liquid into aqueous solution by ultrasound irradiation. Several experimental parameters affecting the extraction efficiency, including type and volume of extraction solvent, type and concentration of surfactant, extraction time, and pH, were optimized. Under the optimized conditions, good linearity with the correlation coefficients (γ) higher than 0.9986 and high sensitivity with the limit of detection ranging from 0.4 to 1.6 μg/L were obtained. The average recoveries ranged from 61.4 to 86.0% for spiked juice, with relative standard deviations from 1.8 to 9.7%. The proposed method was demonstrated to be a simple, fast, and efficient method for the analysis of the target fungicides in juice samples.  相似文献   

16.
In this study, silica modified with a 30‐membered macrocyclic polyamine was synthesized and first used as an adsorbent material in SPE. The SPE was further combined with ionic liquid (IL) dispersive liquid–liquid microextraction (DLLME). Five polycyclic aromatic hydrocarbons were employed as model analytes to evaluate the extraction procedure and were determined by HPLC combined with UV/Vis detection. Acetone was used as the elution solvent in SPE as well as the dispersive solvent in DLLME. The enrichment of analytes was achieved using the 1,3‐dibutylimidazolium bis[(trifluoromethyl)sulfonyl]imide IL/acetone/water system. Experimental conditions for the overall macrocycle‐SPE–IL‐DLLME method, such as the amount of adsorbent, sample solution volume, sample solution pH, type of elution solvent as well as addition of salt, were studied and optimized. The developed method could be successfully applied to the analysis of four real water samples. The macrocyclic polyamine offered higher extraction efficiency for analytes compared with commercially available C18 cartridge, and the developed method provided higher enrichment factors (2768–5409) for model analytes compared with the single DLLME. Good linearity with the correlation coefficients ranging from 0.9983 to 0.9999 and LODs as low as 0.002 μg/L were obtained in the proposed method.  相似文献   

17.
Solid‐phase extraction coupled with dispersive liquid–liquid microextraction was developed as an ultra‐preconcentration method for the determination of four organophosphorus pesticides (isocarbophos, parathion‐methyl, triazophos and fenitrothion) in water samples. The analytes considered in this study were rapidly extracted and concentrated from large volumes of aqueous solutions (100 mL) by solid‐phase extraction coupled with dispersive liquid–liquid microextraction and then analyzed using high performance liquid chromatography. Experimental variables including type and volume of elution solvent, volume and flow rate of sample solution, salt concentration, type and volume of extraction solvent and sample solution pH were investigated for the solid‐phase extraction coupled with dispersive liquid–liquid microextraction with these analytes, and the best results were obtained using methanol as eluent and ethylene chloride as extraction solvent. Under the optimal conditions, an exhaustive extraction for four analytes (recoveries >86.9%) and high enrichment factors were attained. The limits of detection were between 0.021 and 0.15 μg/L. The relative standard deviations for 0.5 μg/L of the pesticides in water were in the range of 1.9–6.8% (n = 5). The proposed strategy offered the advantages of simple operation, high enrichment factor and sensitivity and was successfully applied to the determination of four organophosphorus pesticides in water samples.  相似文献   

18.
This article describes a new, rapid and sensitive method for the determination of chlorotoluron, diethofencarb and chlorbenzuron from water samples with temperature‐controlled ionic liquid‐dispersive liquid‐phase microextraction. In the preconcentration procedure, ionic liquid 1‐hexyl‐3‐methylimidazolium hexafluorophosphate [C6MIM] [PF6] was employed as the extraction solvent. The parameters, such as volume of [C6MIM] [PF6], sample pH, extraction time, centrifuging time, temperature and salting‐out effect, were investigated in detail. Under the optimal extraction conditions, it has been found that three analytes had excellent LODs (S/N=3) in the range of 0.04–0.43 μg/L. The RSDs (n=6) were in the range of 1.3–4.7%. The proposed method was evaluated with lake water, tap water and melted snow water samples. The experimental results indicated that the proposed method had excellent prospect and would be widely used in the future.  相似文献   

19.
An ultrasound‐enhanced in situ solvent formation microextraction has been developed first time and compared with ultrasound‐enhanced ionic‐liquid‐assisted dispersive liquid–liquid microextraction for the HPLC analysis of acaricides in environmental water samples. A ionic liquid ([C8MIM][PF6]) was used as the green extraction solvent through two pathways. The experimental parameters, such as the type and volume of both of the extraction solvent disperser solvent, ultrasonication time, and salt addition, were investigated and optimized. The analytical performance using the optimized conditions proved the feasibility of the developed methods for the quantitation of trace levels of acaricides by obtaining limits of detection that range from 0.54 to 3.68 μg/L. The in situ solvent formation microextraction method possesses more positive characteristics than the ionic‐liquid‐assisted dispersive liquid–liquid microextraction method (except for spirodiclofen determination) when comparing the validation parameters. Both methods were successfully applied to determining acaricides in real water samples.  相似文献   

20.
This study proposed a new ballpoint connector‐protected salt‐oil‐salt liquid phase microextraction for extraction and enrichment of trace rhein and chrysophanol in rhubarb prior to determination of the analytes by high performance liquid chromatography. In this study, a handy ballpoint connector (between ballpoint tip and ink chamber) was used as extraction device, in which its cavity was filled with n‐octanol, and the bare n‐octanol in its two opening ends was covered with a thin layer of sodium chloride film. The design subtly assembled salt film onto ballpoint connector for extraction and enrichment, which greatly improved the enrichment factors of the target analytes. Moreover, the novel procedure and its extraction mechanism were described and analyzed, and several crucial parameters reflecting the extraction effect were investigated and optimized. Under optimum conditions, high enrichment factors (247 and 127), good linearities with ≥ 0.9998, limits of detection (0.6–1.1 ng/mL), relative standard deviations of intra‐ and interday (2.2–8.8% and 4.3–8.9%), and average recoveries (97.6–98.1%), were obtained, respectively. The proposed method can not only eliminate the negative effects from viscosity and ion strength at high salt concentration of sample phase, but also make salting‐out effect be focused on small area so as to maximize the extraction effect.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏