首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
李好丽  赵春霞  张俊杰  傅佳骏  王瑛  路鑫  许国旺 《色谱》2013,31(12):1182-1188
为了分析烤烟中游离氨基酸含量与烤烟香型、产地的关系,以国内14个烟草种植省份的138个调制后的烤烟中部叶片为材料,采用柱前衍生-超高效液相色谱-单重四极杆质谱法对烤烟中的20种游离氨基酸进行分析。方法表征结果显示该方法满足分析要求,适合烤烟中游离氨基酸的检测。对调制后烤烟中部叶片的游离氨基酸分析结果显示,烤烟的游离氨基酸含量在产地间差异很大(28.50%~94.20%),其中天冬酰胺、谷氨酰胺含量的相对标准偏差(RSD)超过80%;在3种典型香型(浓香型、清香型和中间香型)烤烟中,浓香型烤烟游离氨基酸含量的RSD大于其他两种香型。对同一香型的不同种植省份和同一省份不同香型的烤烟游离氨基酸分析结果显示,其含量呈现一定的规律。  相似文献   

2.
A fast, simple, and sensitive HPLC method for the determination of free amino acids in tobacco was described. A fully automated sample processor performed precolumn derivatization of both primary and secondary amino acids with o‐phthalaldehyde/3‐mercaptopropionic acid and 9‐fluorenylmethyl chloroformate (FMOC‐Cl), respectively. All reactions were fully automated by means of an injector programme and accomplished in 10 min. Sample preparation consisted of a single step of extraction with 0.1 mol/L HCl at ambient temperature (assisted by sonication) in 30 min, followed by filtration of an aliquot and derivatization. By optimization of sample preparation and HPLC conditions, separation of 20 amino acids in 30 min was achieved. Detection limits ranged from 0.50 to 1.40 μg/g; coefficients of variation ranged from 1.8% to 3.9%; recoveries ranged from 84.6% to 108.5%. The method was applied to the analysis of amino acids contents of tobacco leaves in different varieties and flue‐curing period.  相似文献   

3.
A method for the determination of selected amino acids in culture medium using HPLC with fluorescence detection is described. Twenty hours after intra‐cytoplasmic sperm injection, one randomly selected zygote was transferred to the culture medium. After incubation (72 h after fertilization), the culture medium in which the embryo was incubated and blank medium was immediately stored at −80°C. Filtered medium samples were derivatized with ortho ‐phthalaldehyde (naphthalene‐2,3‐dicarboxaldehyde), forming highly fluorescent amino acids derivatives. Reverse‐phase columns (LichroCART, Purospher STAR RP18e or Ascentis Express C18) were used for the separation. The derivatives were analyzed by gradient elution with a mobile phase containing ethanol and sodium dihydrogen phosphate. The analytical performance of this method is satisfactory for all amino acids; the intra‐assay coefficients of variation were <10% and quantitative recoveries were between 95.5 and 104.4%. Changes in the levels of selected amino acids before and after human embryo cultivation were observed. After embryo incubation, the levels of all amino acids in the medium were increased, apart from aspartate and asparagine. After the cultivation of some embryos, amino acids which were not part of the medium were detected. Low amino acids turnover was observed in some embryos.  相似文献   

4.
A rapid, sensitive, and reliable ultra‐performance liquid chromatography (UPLC) coupled with photodiode array detection method was developed for the amino acid analysis of Amur sturgeon (Acipenser schrenckii Brandt). The method uses minimal sample volume and automated online precolumn derivitization of amino acids with fluorescent 6‐aminoquinolyl‐carbamyl reagent. The chromatographic separation was achieved by UPLC, which used a column with 1.7 μm particle packing that enabled higher speed of analysis, peak capacity, greater resolution, and increased sensitivity. Amino acid derivatives obtained under optimal conditions were separated on a Waters UPLC BEH C18 column with Acetonitrile–acetate buffer as mobile phase. Matrix effects were investigated and good linearities with correlation coefficients better than 0.9949 were obtained over a wide range of 5–1000 μmol/L for all amino acids. The simple sample preparation and minimal sample volume make the method useful for the quantitation of 17 amino acids in Amur sturgeon samples. It is concluded that a rapid and robust platform based on UPLC was established, and a total of 17 amino acids of Amur sturgeon were tentatively detected. This method showed good accuracy and repeatability that can be used for the quantification of amino acids in real samples.  相似文献   

5.
氨基化合物在植物生长发育中起着重要作用。本文建立了一种基于柱前衍生-超高效液相色谱-质谱联用技术的植物提取液中氨基化合物代谢谱的分析方法。以烟草鲜叶为例,共检测出87种氨基化合物。其中43种氨基化合物的定量分析结果表明,方法的线性相关系数在0.993~0.999之间,线性范围可达到4个数量级,检出限为0.03~6.58 ng/mL,日内、日间精密度分别为0.7%~15.6%、0.8%~22.9%,回收率为74.4%~122.7%。采用该方法考察了打顶对不同部位烟草鲜叶中氨基化合物代谢谱的影响,结果显示打顶处理对上部叶影响最大,打顶后上部叶氮代谢主要流向生物碱合成方向。该方法充分利用了三重四极杆串联质谱和高分辨串联质谱技术的优势,可实现植物提取液中氨基代谢物的高选择性、高灵敏度分析。  相似文献   

6.
The combination of capillary electrophoresis (CE) and light-emitting diode-induced fluorescence (LED-IF) detection has been demonstrated in the analysis of major amino acids in tea leaves and beverages. The separation efficiency of amino acids, which were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA), depended on the capillary length and PEO concentration. We suggested that the interactions between the NDA derivatives and poly(ethylene oxide) (PEO) molecules are based on hydrogen bonding, hydrophobic patches, and Van der Waals forces. The magnitude of EOF and the interactions between them can be further controlled by the capillary length. The separation of 17 NDA-amino acids derivatives was completed within 16 min using 0.5% PEO and 60 cm capillary length. The relative standard deviations (R.S.D.) of their migration times (n = 5) were less than 2.7%. Additionally, the limits of detection at signal-to-noise ratio 3 for the tested amino acids ranged from 3.6 to 28.3 nM. Quantitative determination of amino acids in tea leaves and beverages was accomplished by our proposed method. This study showed that amino acid present in highest concentration in tea leaves and beverages is γ-aminobutyric acid and theanine, respectively. The experimental results suggest that our proposed methods have great potential in the investigation of the biofunction of different tea samples.  相似文献   

7.
A procedure is described for the quantitative determination of amino acids in hepatic and brain tissue samples from the rat. Because the presence of certain matrix components in the tissue material led to interference with chromatographic analysis they were removed by a prechromatographic “clean-up” step. Quantitative analysis of amino acids, as their N-heptafluorobutyryl iso-butyl ester derivatives, was achieved by high resolution gas chromatography on an apolar fused silica open tubular column. Reproducibility data from the complete procedure are presented; coefficients of variation for arginine and histidine in hepatic tissue varied between 7.1 and 10.1% whereas those for most other amino acids were better than 5%, with a mean recovery of 90%.  相似文献   

8.
Methylation is an essential metabolic process in the biological systems, and it is significant for several biological reactions in living organisms. Methylated compounds are known to be involved in most of the bodily functions, and some of them serve as biomarkers. Theoretically, all α‐amino acids can be methylated, and it is possible to encounter them in most animal/plant samples. But the analytical data, especially the mass spectral data, are available only for a few of the methylated amino acids. Thus, it is essential to generate mass spectral data and to develop mass spectrometry methods for the identification of all possible methylated amino acids for future metabolomic studies. In this study, all N‐methyl and N,N‐dimethyl amino acids were synthesized by the methylation of α‐amino acids and characterized by a GC‐MS method. The methylated amino acids were derivatized with ethyl chloroformate and analyzed by GC‐MS under EI and methane/CI conditions. The EI mass spectra of ethyl chloroformate derivatives of N‐methyl ( 1–18 ) and N,N‐dimethyl amino acids ( 19–35 ) showed abundant [M‐COOC2H5]+ ions. The fragment ions due to loss of C2H4, CO2, (CO2 + C2H4) from [M‐COOC2H5]+ were of structure indicative for 1–18 . The EI spectra of 19–35 showed less number of fragment ions when compared with those of 1–18 . The side chain group (R) caused specific fragment ions characteristic to its structure. The methane/CI spectra of the studied compounds showed [M + H]+ ions to substantiate their molecular weights. The detected EI fragment ions were characteristic of the structure that made easy identification of the studied compounds, including isomeric/isobaric compounds. Fragmentation patterns of the studied compounds ( 1–35 ) were confirmed by high‐resolution mass spectra data and further substantiated by the data obtained from 13C2‐labeled glycines and N‐ethoxycarbonyl methoxy esters. The method was applied to human plasma samples for the identification of amino acids and methylated amino acids. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
A rapid analytical method for amines and amino acids was developed, involving derivatization with the novel reagent 3‐aminopyridyl‐N‐hydroxysuccinimidyl carbamate (APDS), followed by reversed‐phase high‐performance liquid chromatography and electrospray ionization tandem mass spectrometry (HPLC/ESI‐MS/MS). More than 100 different analytes with amino groups, including amino acids in biological fluids such as mammalian plasma, could be measured within 10 min. The analytes were easily derivatized with APDS under the mild conditions. Selective reaction monitoring of ESI‐MS/MS in positive mode was carried out to include the transitions of all of the protonated molecular ions of analytes derivatized with APDS to the common fragment at m/z 121, which was derived from the amino pyridyl moiety of the reagent. We evaluated the retention time precision, the quantification limits, the linearity, the intra‐ and inter‐day precisions and the accuracy of 22 typical amino acids found in biological fluids, by analyzing a standard amino acid mixture and rat plasma. The intra‐day relative standard deviations (RSDs) of the retention times of the 22 amino acids and their internal standards were within 0.9% and the inter‐day RSDs were less than 1.1%, except for asparagines, with an RSD of 1.9%. The intra‐day and inter‐day RSDs of amino acid analyses in rat plasma were within 8.0% and 4.5%, respectively. The method, which facilitates the amino acid analysis of more than 100 samples in a day, represents an alternative to traditional amino acid analysis techniques, such as chromatography using postcolumn derivatization by ninhydrin. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

10.
Li Y  Pang T  Li Y  Wang X  Li Q  Lu X  Xu G 《Journal of separation science》2011,34(12):1447-1454
A gas chromatography-mass spectrometric method was developed for profiling of tobacco leaves. The differentiation among tobacco leaves planted in two different regions was investigated. Prior to analysis, the extraction solvent formulation was optimized and a combination of water, methanol and acetonitrile with a volume ratio of 3:1:1 was found to be optimal. The reproducibility of the method was satisfactory. Kendall tau-b rank correlation coefficients were equal to 1 (p<0.05) for 82% of the resolved peaks (up to 95% of the overall peak areas), indicating the good response correlation. Forty-four compounds including 9 saccharides, 9 alcohols, 9 amino acids, 16 organic acids and phosphoric acid were identified based on standard compounds. The method was successfully applied for profiling of tobacco leaves from Zimbabwe and Yunnan of China. Our result revealed that levels of saccharides and their derivatives including xylose, ribose, fructose, glucose, turanose, xylitol and glyceric acid were more abundant while sucrose, glucitol and D-gluconic acid were less abundant in tobacco leaves from Yunnan as compared to those from Zimbabwe. Amino acids such as L-alanine, L-tyrosine and L-threonine were found to be richer in Zimbabwe tobacco than in Yunnan tobacco.  相似文献   

11.
A comparison of the elution properties of the major protein amino acids as their N(O)-acyl alkyl ester derivatives (O-n-propyl, -n-butyl, -isopentyl; N(O)-trifluoroacetyl, -heptafluorobutyryl) on open-tubular glass capillary columns coated with SE-30, OV-17, OV-210 and EGA is described. A single-column separation to the baseline of the protein amino acids as their N(O)-heptafluorobutyryl n-butyl ester derivatives in less than 35 min was obtained on the SE-30 column. OV-210 columns have properties complementary to those of SE-30 columns and can be used as an aid to compound identification from retention time data. Separations of the amino acids from beer and dialysate from uremic patients are used to illustrate the practical posibilities of the method.  相似文献   

12.
A precolumn derivatization method for the determination of amino acids using 6-aminoquinolyl-N-hyroxy-succinimidyl carbamate (AQC) followed by high-performance liquid chromatography is described. Ultraviolet detection was used for the assay of AQC derivatives of amino acids with the detection wavelength set at 248 nm. The reagent peak interference was minimized by optimizing the pH of the eluent and the gradient elution profile to improve the resolution between the reagent peak and amino acid derivatives. All nineteen amino acids were separated in 35 min with resolutions 1.6. The correlation coefficients of the calibration graphs for seventeen amino acids were fairly good (r 0.9999) at concentrations of 25–500 μM. The detection limits for all common amino acids including cystine and trytophan were at the range of 0.07–0.3 pmol. Good reproducibility and accuracy of the method were demonstrated by the determination of amino acids in three typical kinds of samples (protein, peptide and feed.) The average relative standard deviations for bovine serum albumin (BSA) and neuromedin were 0.86% and 1.36, respectively, and the average relative errors were 3.2% and 2.3%, respectively. The results of the analysis of feed hydrolysates agreed with those obtained by an ion-exchange method and the average recovery of the method for feed hydrolysates was 98%.  相似文献   

13.
A simple, rapid and accurate high‐performance liquid chromatography method with ultraviolet–visible detection was developed for the determination of five amino acid neurotransmitters – aspartate, glutamic acid, glycine, taurine and γ‐aminobutyric acid – in rat hippocampi with pre‐column derivatization with 4‐fluoro‐7‐nitrobenzofurazan. Several conditions which influenced derivatization and separation, such as pH, temperature, acetonitrile percentage mobile phase and flow rate, were optimized to obtain a suitable protocol for amino acids quantification in samples. The separation of the five neurotransmitter derivatives was performed on a C18 column using a mobile phase consisting of phosphate buffer (0.02 mol/L, pH 6.0)–acetonitrile (84:16, v/v) at a flow rate of 1.0 mL/min with the column temperature at 30°C. The detection wavelength was 472 nm. Without gradient elution, the five neurotransmitter derivatives were completely separated within 15 min. The linear relation was good in the range from 0.50 to 500 µmol/L, and the correlation coefficients were ≥0.999. Intra‐day precision was between 1.8 and 3.2%, and inter‐day precision was between 2.4 and 4.7%. The limits of detection (signal‐to‐noise ratio 3) were from 0.02 to 0.15 µmol/L. The established method was used to determine amino acid neurotransmitters in rat hippocampi with satisfactory recoveries varying from 94.9 to 105.2%. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
A simple method was developed and validated for the simultaneous determination of metalaxyl, cyazofamid and the cyazofamid metabolite 4‐chloro‐5‐p‐tolylimidazole‐2‐carbonitrile (CCIM) by liquid chromatography with tandem mass spectrometry. The three target compounds were extracted from tobacco and soil with acetonitrile containing 0.1% acetic acid, and the extracts were purified using octadecylsilane. The proposed method showed satisfactory linearity (R2 ≥ 0.9985) for the target compounds. The limits of detection for metalaxyl, cyazofamid and CCIM were 0.006, 0.06 and 0.06 mg/kg in soil and green tobacco leaves and 0.03, 0.3 and 0.3 mg/kg in cured tobacco leaves, respectively. The limits of quantification for metalaxyl, cyazofamid and CCIM were 0.02, 0.2 and 0.2 mg/kg in soil and green tobacco leaves and 0.1, 1 and 1 mg/kg in cured tobacco leaves, respectively. The average recoveries from soil and tobacco were 72.91–98.40% for metalaxyl, 76.73–105.80% for cyazofamid and 74.48–106.45% for CCIM. The relative standard deviation range was 1.23–6.99%. The developed method was successfully applied to analysis of residues of metalaxyl, cyazofamid and CCIM in real soil and tobacco samples. The results indicated that the established method could meet the requirement for the analysis of trace amounts of all three analytes in soil and tobacco.  相似文献   

15.
An automated method for high‐throughput amino acid analysis, using precolumn derivatization high‐performance liquid chromatography/electrospray mass spectrometry (HPLC/ESI‐MS), was developed and evaluated. The precolumn derivatization step was performed in the reaction port of a home‐built auto‐sampler system. Amino acids were derivatized with 3‐aminopyridyl‐N‐hydroxysuccinimidyl carbamate, and a 3 μm Wakosil‐II 3C8‐100HG column (100 × 2.1 mm i.d.) was used for separation. To achieve a 13 min cycle for each sample, the derivatization and separation steps were performed in parallel. The results of the method evaluation, including the linearity, and the intra‐ and inter‐precision, were sufficient to measure physiological amino acids in human plasma samples. The relative standard deviations of typical amino acids in actual human plasma samples were below 10%. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
This work describes a rapid, stable, and accurate method for determining the free amino acids, biogenic amines, and ammonium in tobacco. The target analytes were extracted with microwave‐assisted extraction and then derivatized with diethyl ethoxymethylenemalonate, followed by ultra high performance liquid chromatography analysis. The experimental design used to optimize the microwave‐assisted extraction conditions showed that the optimal extraction time was 10 min with a temperature of 60°C. The stability of aminoenone derivatives was improved by keeping the pH near 9.0, and there was no obvious degradation during the 80°C heating and room temperature storage. Under optimal conditions, this method showed good linearity (R 2 > 0.999) and sensitivity (limits of detection 0.010–0.081 μg/mL). The extraction recoveries were between 88.4 and 106.5%, while the repeatability and reproducibility ranged from 0.48 to 5.12% and from 1.56 to 6.52%, respectively. The newly developed method was employed to analyze the tobacco from different geographical origins. Principal component analysis showed that four geographical origins of tobacco could be clearly distinguished and that each had their characteristic components. The proposed method also showed great potential for further investigations on nitrogen metabolism in plants.  相似文献   

17.
A method to quantitate blood and plasma amino acids by isotope dilution gas chromatography/mass spectrometry (GC/mS) is described. Samples were spiked with U-(13)C amino acids as internal standards and the tert-butyldimethylsilyl derivatives (tBDMS) separated by capillary column gas chromatography. Linear regression curves, generated for individual amino acids, gave correlation coefficients of 0.9999. The reproducibility of the method was assessed from the analysis of 10 replicate blood and plasma samples. For most amino acids a coefficient of variance (CV) of 相似文献   

18.
A new derivatization–extraction method for preconcentration of seleno amino acids using hollow fiber liquid phase microextraction (HF‐LPME) was developed for the separation and determination of seleno amino acids in biological samples by gas chromatography–inductively coupled plasma mass spectrometry (GC–ICP‐MS). Derivatization was performed with ethyl chloroformate (ECF) to improve the volatility of seleno amino acids. Parameters influencing microextraction, including extraction solvent, pH of sample solution, extraction time, stirring speed, and inorganic salt concentration have been investigated. Under the optimal conditions, the limits of detection (LODs) obtained for Se‐methyl‐selenocysteine (SeMeCys), selenomethionine (SeMet), and selenoethionine (SeEth) were 23, 15, and 11 ng Se l−1, respectively. The relative standard deviations (RSDs) were 14.6%, 16.4%, and 19.4% for SeMeCys, SeMet, and SeEth (c = 1.0 ng ml−1, n = 7), respectively, and the RSDs for SeMeCys, SeMet could be improved obviously if SeEth was utilized as the internal standard. The proposed method was applied for the determination of seleno amino acids in extracts of garlic, cabbage, and mushroom samples, and the recoveries for the spiked samples were in the range of 96.8–108% and 93.4–115% with and without the use of SeEth as internal standard. The developed method was also applied to the analysis of SeMet in a certified reference material of SELM‐1 yeast and the determined value is in good agreement with the certified value. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
A pseudotargeted method based on gas chromatography and mass spectrometry with selected‐ion monitoring was established to investigate the metabolite differences of flue‐cured tobacco from three different growing regions. The mixed solvent of acetonitrile/isopropanol/water (3:3:2, v/v/v) was chosen as the optimal extraction system based on the good repeatability and extraction efficiency. A self‐developed software coupled with commercial software was used to establish the pseudotargeted method including 289 peaks and 47 groups. Multivariable statistical analysis indicated that tobacco samples can be obviously separated based on the geographical origins. On the basis of a Mann–Whitney U test, organic acids, phenols, and alkaloids had higher levels in Hunan province. In contrast, a large proportion of amino acids (including l ‐tyrosine, l ‐proline, and serine), sucrose, and linoleic acid were the highest in Yunnan province. Meanwhile, multiple metabolic pathways (including carbohydrate metabolism, tricarboxylic acid cycle, and nitrogen metabolism) were influenced by growing regions. Twenty‐eight differential metabolites, which had great contributions to the classification of tobacco samples of three growing regions, were further defined. The results demonstrated that the developed pseudotargeted method was a powerful tool to investigate the metabolic profiling of tobacco leaves and discriminate tobacco leaves of different growing regions.  相似文献   

20.
A simple and rapid method for the simultaneous analysis of amino acids has been developed. Amino acids were derivatised based on pre-capillary derivatisation with 1,2-naphthoquinone-4-sulfonate (NQS) in basic medium (pH 10.0) and developed reaction at 70 degrees C. Their derivatives were analysed by capillary zone electrophoresis (CZE). The parameters affecting CZE separation were investigated including buffer (pH, type and concentration), organic modifier and separation voltage. The optimum condition was 70 mmol L(-1) borate (pH 10.0) containing 10% acetonitrile, separation voltage of 12 kV, and sample injection (0.5 psi, 5s) and on-capillary detection at 240 nm. The separation of seven amino acids was achieved within 17 min. The detection limit was 1.0 mg L(-1) for all studied amino acids. The calibration curves were linear in the concentration range of 1.0-100.0 mg L(-1). The repeatability, intra-day and inter-day analysis were < or = 1.0% and < or = 2.0% for migration time and < or = 5.0% and 6.0% for peak area. The proposed method has been applied to several beverage samples with only a simple dilution and filtration treatment of sample before derivatisation and analysed by CZE.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏