1.
The horizontal test for the BEPC 500 MHz spare cavity has been completed at IHEP. The maximum voltage of the cavity reached 2.17 MV, while Q 0 was 5.78 × 108 . The process and results of the high power horizontal test are presented and discussed in this paper.  相似文献   

2.
The tuning system plays a very important role when a superconducting cavity is in operation. It cooperates with other control loops to adjust the cavity frequency with high precision, reduce the reflection power, guarantee the stability of beam, and ensure the safety of the superconducting cavity. This paper focuses mainly on the tuning system working principle, the working state and problems that Beijing Electron Positron Collider (BEPC ) has encountered during operation.  相似文献   

3.
To test superconducting cavities, a vertical test system has been designed and set up at the Institute of Modern Physics (IMP). The system design is based on VCO-PLL hardware and the NI Labview software. The test of the HWR010#2 superconducting cavity shows that the function of this test system is satisfactory for testing the low frequency cavity.  相似文献   

4.
Twelve very low Beta superconducting single spoke cavities, whose Beta is only 0.12 (Spoke012) when operating at 325 MHz, are adopted in Injector I for China-ADS linac. This type of spoke cavity is believed to be one of the key challenges for its very low geometric Beta. So far, in collaboration with Peking University and Harbin Institute of Technology, IHEP has successfully designed, fabricated, and tested the Spoke012 prototype cavity. This paper presents the details of the design, fabrication and test results for Spoke012 prototype cavity.  相似文献   

5.
The BEPCII storage ring adopts two 500 MHz superconducting cavities (SCC). Each one is equipped with a 500 MHz input power coupler. The coupler is to feed 150 kW power in continuous wave (CW) mode with both standing and traveling wave modes. Due to high power feeding and high frequency of the coupler, its fabrication is a big challenge. The fabrication started with two key components,the window and the antenna. Up to now, two sets including windows and antennas have been made by IHEP. And a 270 kW RF power in CW has passed through the coupler during the high power test. The fabrication details are presented in this paper.  相似文献   

6.
北京正负电子对撞机二期(BEPCⅡ),国产500 MHz超导腔经过紧张的安装调试于2017年10月正式投入带束流运行。首先对此国产超导腔两次降温调试的相关参数进行了监测和对比分析;其次研究了通过高功率老练的方法改善超导腔的品质因数,并实时监测超导腔老练过程中的辐射剂量;最后对超导腔的带束流运行情况进行了介绍分析。结果表明:BEPCⅡ国产500 MHz超导腔虽然放置了6年,但是状态良好,通过高功率老练能够降低超导腔的辐射剂量,改善其性能,完全满足束流运行要求。  相似文献   

7.
High power conditioning of the input coupler for BEPCII superconducting cavity has been performed. After room temperature conditioning, the RF power of 150 kW with continuous wave at standing wave mode passed through the coupler without any problem. Meanwhile, a series of methods have also been studied to improve the performance of the coupler during the beam operation. Up to now, the input coupler can feed a RF power up to 100 kW stably with high current of 250 mA at 2.5 GeV.  相似文献   

8.
A passive higher harmonic cavity (HHC) will be used in the Hefei Light Source II Project (HLS-Ⅱ) to lengthen the bunch and consequently increase the beam lifetime dominated by Touschek scattering. The effects of constant voltage and constant detuning have been calculated and compared over the operating current from 0.4 to 0.2 A on the bunch lengthening for the passive normal conducting harmonic cavity system in HLS-Ⅱ. The results show that the bunch shape has less change and the lifetime improvement factors are not less than 2.7 over the beam currents for the constant voltage case. The constant voltage operating scheme may be applied to our machine.  相似文献   

9.
This paper illustrates the design and simulation of a unique 500 MHz single-cell superconducting radio frequency cavity with a fluted beam pipe and a coaxial-type fundamental power coupler. The simulation results show that the cavity has a high r/Q value, a low peak surface field and a large beam aperture, so it can be a candidate cavity for high current accelerators. With the help of a fluted beam tube, almost all the higher order modes can propagate out of the cavity, especially the first two dipole modes, TE111 and TM110, and the first higher monopole mode, TM011. The external quality factor of the coaxial fundamental power coupler is optimized to 1.2×105, which will be useful when it is applied in the light source storage ring.  相似文献   

10.
A simulation code that executes the tracking of longitudinal oscillations of the bunches for the double rf system of the Hefei Light Source Ⅱ Project (HLS-Ⅱ) is presented to estimate the mean beam lifetime and the Robinson instabilities. The tracking results show that the mean beam lifetime is in agreement with the analytical results and the system is stable when we tune the harmonic cavity in the optimum lengthening conditions. Moreover, the simulated results of the asymmetric fill pattern show that some bunches are compressed only with a 7% gap (3 gaps), which will lead to the reduction in the mean bunch lengthening and potential beam lifetime. It is demonstrated that HLS-Ⅱ with a passive higher harmonic cavity is not suitable for operating in an asymmetric fill pattern.  相似文献   

11.
In the Phase Ⅱ Project at the Hefei Light Source, a fourth-harmonic "Landau" cavity will be operated in order to suppress the coupled-bunch instabilities and increase the beam lifetime of the Hefei storage ring. Instabilities limit the utility of the higher-harmonic cavity when the storage ring is operated with a small momentum compaction. Analytical modeling and simulations show that the instabilities result from Robinson mode coupling. In the analytic modeling, we operate an algorithm to consider the Robinson instabilities. To study the evolution of unstable behavior, simulations have been performed in which macroparticles are distributed among the buckets. Both the analytic modeling and simulations agree for passive operation of the harmonic cavity.  相似文献   

12.
张瑾  叶柳 《中国物理》2004,13(9):1438-1441
We present an efficient scheme for preparation of the multi-atom W state via cavity quantum electrodynamics. Involved in this scheme are n identical two-level atoms and a single-mode cavity field. Discussion indicates that this scheme can be realized easily by current technologies.  相似文献   

13.
The fast luminosity monitor counting the γ photons above a given energy threshold emitted from radiative Bhabha scattering has been operated in the BEPC Ⅱ to measure the relative luminosity bunch by bunch for the first time and used successfully in beam tuning of BEPC Ⅱ. In the relative mode the monitor is able to deliver the relative luminosities with an accuracy of 0.8 %. By steering the electron beam while observing the counting rate changes of the monitor the horizontal and vertical sizes of the bunch spots can be estimated as: Sxe+ =Sxe =0.356 mm, Sye+ =Sye- =0.011 mm.  相似文献   

14.
Superconducting deflecting cavities can be used in synchrotron light source to generate subpico-second X-ray pulses while the impedance of the lower order modes (LOM) and higher order modes (HOM) in the cavity should be kept below an accepted level to avoid beam instability. These modes can be damped by adding waveguide on beam pipe. Detailed simulation of Q in CST Microwave  相似文献   

15.
A prototype multi-gap resistive plate chamber (MRPC) with a 2×6 gap structure is developed for the upgrading of the endcap time-of-flight (ETOF) detector in the Beijing Spectrometer (BESⅢ). The prototype MRPC is tested in the E3 beam line of the Beijing Electron Positron Collider (BEPC) with secondary charged particles (π and p, etc) of 600 MeV/c. The test results show that the time resolution of the MRPC can reach 50 ps and that the detection efficiency is greater than 98%.  相似文献   

16.
Two plastic scintillating fiber position detectors for charged particles have been designed, built and installed inside the vacuum tube near two sides of the DM2 deflection magnet on the E3 beam line of the test beam facility at the BEPC-LINAC. A one-dimensional position resolution of sim 1 mm with a sensitive area of 60 mm×60 mm has been obtained for this detector.  相似文献   

17.
Two plastic scintillating fiber position detectors for charged particles have been designed, built and installed inside the vacuum tube near two sides of the DM2 deflection magnet on the E3 beam line of the test beam facility at the BEPC-LINAC. A one-dimensional position resolution of sim 1 mm with a sensitive area of 60 mm×60 mm has been obtained for this detector.  相似文献   

18.
A higher-harmonic cavity will be used to increase the beam lifetime and suppress coupled-bunch instabilities for Hefei Light Source-Ⅱ. In this paper, results simulated by the particle-tracking model confirm that tuning in the harmonic cavity may suppress the parasitic coupled-bunch instabilities. The factors calculated for lifetime improvement are larger than 2.5. The 3rd and 4th harmonic cavities have been designed. In particular, the absorbers and antenna couplers are applied in harmonic cavities to damp the higher order modes. Finally, the 4th harmonic cavity similar to the Duke's RF cavity will be used for HLS-Ⅱ.  相似文献   

19.
中国科学院武汉物理与数学研究所(WIPM)于2010年成功研制了500 MHz(WIPM-I 500)高分辨超导核磁共振(NMR)谱仪,并将其投入实际应用中.然而,关于其二维核磁共振(2D NMR)谱图的准确性及在此基础上对复杂物质的结构解析尚无系统完整的数据报道.该文利用WIPM-I 500型NMR谱仪,对紫杉醇样品进行了1D NMR及2D NMR(包括1H-1H COSY、1H-1H TOCSY、J-Res、1H-13C HMQC和1H-13C HMBC)实验,将谱图分析结果与进口仪器进行了对比.结果表明:利用WIPM-I 500型NMR谱仪能够采集准确的2D NMR谱图,为紫杉醇的正确归属提供了实验基础;而且该文也纠正了文献中对紫杉醇的错误归属.  相似文献   

20.
王逗  秦庆  高杰 《中国物理 C》2010,34(11):1762-1767
In this paper,a dedicated synchrotron radiation (SR) mode for the BEPCⅡ with an emittance of 85 nm has been designed,including the linear lattice,chromaticity correction and dynamic aperture optimization.The emittance of the new mode is about 60% of the previous mode used for routine operation of the BEPCⅡ .The effect of wigglers on the linear lattice was compensated and the total dynamic aperture including the wigglers’ nonlinear effect was estimated.The preliminary commissioning at the end of 2008 and the formal operation with the new mode confirmed its merits.  相似文献   