首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Biothiols, such as cysteine (Cys) and homocysteine (Hcy), play very crucial roles in biological systems. Abnormal levels of these biothiols are often associated with many types of diseases. Therefore, the detection of Cys (or Hcy) is of great importance. In this work, we have synthesized an excellent “OFF‐ON” phosphorescent chemodosimeter 1 for sensing Cys and Hcy with high selectivity and naked‐eye detection based on an IrIII complex containing a 2,4‐dinitrobenzenesulfonyl (DNBS) group within its ligand. The “OFF‐ON” phosphorescent response can be assigned to the electron‐transfer process from IrIII center and C^N ligands to the DNBS group as the strong electron‐acceptor, which can quench the phosphorescence of probe 1 completely. The DNBS group can be cleaved by thiols of Cys or Hcy, and both the 3M LCT and 3LC states are responsible for the excited‐state properties of the reaction product of probe 1 and Cys (or Hcy). Thus, the phosphorescence is switched on. Based on these results, a general principle for designing “OFF‐ON” phosphorescent chemodosimeters based on heavy‐metal complexes has been provided. Importantly, utilizing the long emission‐lifetime of phosphorescence signal, the time‐resolved luminescent assay of 1 in sensing Cys was realized successfully, which can eliminate the interference from the short‐lived background fluorescence and improve the signal‐to‐noise ratio. As far as we know, this is the first report about the time‐resolved luminescent detection of biothiols. Finally, probe 1 has been used successfully for bioimaging the changes of Cys/Hcy concentration in living cells.  相似文献   

2.
Due to the similar structure and reactivity of cysteine (Cys), homocysteine (Hcy) and glutathione (GSH), the simultaneous discrimination of Cys over Hcy and GSH by a single fluorescent sensor is still a great challenge. In this work, a benzothiazole‐pyimidine‐based boron difluoride complex ( BPB ) was developed as a new fluorescent sensor for Cys. The sensor exhibits a highly selective “turn‐on” response to cysteine over Hcy, GSH and other amino acids in aqueous solution at physiological pH. The observed pseudo‐first‐order rate constant for the reaction of BPB with Cys was calculated to be about 0.062 min−1. The detection limit of this sensor for Cys was determined to be 332 nm, and bioimaging of exogenous Cys by this sensor was successfully applied in living cells, thus indicating that this sensor holds great potential for biological applications.  相似文献   

3.
The simultaneous discrimination of Cys, Hcy, and GSH by a single probe is still an unmet challenge. The design and synthesis of a small molecule probe MeO‐BODIPY‐Cl (BODIPY=boron dipyrromethene) is presented, which can allow Cys, Hcy, and GSH to be simultaneously discriminated on the basis of three distinct fluorescence turn‐on responses. The probe reacts with these thiols to form sulfenyl‐substituted BODIPY, which is followed by intramolecular displacement to yield amino‐substituted BODIPY. The kinetic rate of the intramolecular displacement reaction determines the observed different sensing behavior. Therefore, the probe responds to Cys, Hcy, and GSH with fluorescence turn‐on colors of yellow, yellow and red, and red, respectively. With this promising feature in hand, the probe was successfully used in imaging of Cys, Hcy and GSH in living cells.  相似文献   

4.
We demonstrate a concept‐proof work of using fluorescence (FL) “turn‐on” probes for the discriminatory detection of cysteine (Cys) over homocysteine (Hcy). The fluorogens are provided with aggregation‐induced emission (AIE) characteristic and functionalized with two aldehyde‐groups (DMTPS‐ALD and TPE‐ALD). All the detections were carried out in a biocompatible medium (10 mM HEPES buffer and DMSO, pH 7.4). In principle, the formation of thiazinane/thiazolidine through the chemical reaction of aldehydes on the probe molecules and the residue of Cys/Hcy determines the selective recognition of Cys and Hcy over other amino acids and glucose. The FL responses originate from the AIE property of thiazinane/thiazolidine resultants, which have low solubility and precipitate (aggregate) in the detection medium. The discrimination between Cys and Hcy comes from the difference in reaction kinetics of TPE‐ALD/DMTPS‐ALD with Cys and Hcy, thereby the FL responses show different time courses and intensity enhancement. It is worth noting that TPE‐ALD outshined the other two probes in performance with fast response, a high FL enhancement up to 16‐fold, high sensitivity, and good specificity and selectivity. Moreover, its FL response threshold at 250 μM is very close to the lower limit of the normal level of Cys in human plasma, which implies that TPE‐ALD could be applied as a potential indicator of Cys deficiency.  相似文献   

5.
An HPLC‐fluorescence (FL) method for determination of sulfur‐containing amino acids such as homocysteine (Hcy), methionine (Met) and cysteine (Cys) in human plasma was developed. The sulfur‐containing amino acids were labeled with 4‐(N,N‐dimethylaminosulfonyl)‐7‐fluoro‐2,1,3‐benzoxadiazole (DBD‐F). Calibration curves in the range of 1–100 µm (Hcy and Met) and 5–500 µm (Cys) indicated good linearities (r ≥ 0.998). The limits of detection at a signal‐to‐noise ratio of 3 were 0.13 (Hcy), 0.02 (Met) and 0.11 µm (Cys), respectively. Acceptable results for accuracy and precision of intra‐ and inter‐day measurements were obtained. The results of Hcy and Cys obtained by the proposed method indicated good correlations with the conventional method (r > 0.911, n = 20). Furthermore, the method was applied to determination of the sulfur‐containing amino acids in maternal plasma (n = 200) after delivery. The concentrations of Hcy, Met and Cys as a median (inter quartile range, Q1 and Q3) were 5.37 (3.32–7.79) μm , 25.20 (20.10–31.06) μm and 147.25 (102.81–189.31) μm , respectively. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
A new phosphorescent dinuclear cationic iridium(III) complex ( Ir1 ) with a donor–acceptor–π‐bridge–acceptor–donor (D? A? π? A? D)‐conjugated oligomer ( L1 ) as a N^N ligand and a triarylboron compound as a C^N ligand has been synthesized. The photophysical and excited‐state properties of Ir1 and L1 were investigated by UV/Vis absorption spectroscopy, photoluminescence spectroscopy, and molecular‐orbital calculations, and they were compared with those of the mononuclear iridium(III) complex [Ir(Bpq)2(bpy)]+PF6? ( Ir0 ). Compared with Ir0 , complex Ir1 shows a more‐intense optical‐absorption capability, especially in the visible‐light region. For example, complex Ir1 shows an intense absorption band that is centered at λ=448 nm with a molar extinction coefficient (ε) of about 104, which is rarely observed for iridium(III) complexes. Complex Ir1 displays highly efficient orange–red phosphorescent emission with an emission wavelength of 606 nm and a quantum efficiency of 0.13 at room temperature. We also investigated the two‐photon‐absorption properties of complexes Ir0 , Ir1 , and L1 . The free ligand ( L1 ) has a relatively small two‐photon absorption cross‐section (δmax=195 GM), but, when complexed with iridium(III) to afford dinuclear complex Ir1 , it exhibits a higher two‐photon‐absorption cross‐section than ligand L1 in the near‐infrared region and an intense two‐photon‐excited phosphorescent emission. The maximum two‐photon‐absorption cross‐section of Ir1 is 481 GM, which is also significantly larger than that of Ir0 . In addition, because the strong B? F interaction between the dimesitylboryl groups and F? ions interrupts the extended π‐conjugation, complex Ir1 can be used as an excellent one‐ and two‐photon‐excited “ON–OFF” phosphorescent probe for F? ions.  相似文献   

7.
A semi‐micro column HPLC‐fluorescence method for routine determination of thiol derivatives such as homocysteine (Hcy), cysteine (Cys) and cysteamine (CA) is described. The thiol derivatives labeled with ammonium‐7‐fluorobenzo‐2‐oxa‐1,3‐diazole‐4‐sulfonate (SBD‐F) were isocratically separated within 12 min on a semi‐micro ODS column (Daisopak‐SP‐120‐5‐ODS‐BP) with a mixture of 25 mm acetate buffer (pH 2.00) and CH3CN as a mobile phase. The purity and similarity of SBD‐thiols by a multi‐wavelength fluorescence detector were more than 92.3 and 96.7%. The detection limits of Hcy, Cys and CA at a signal‐to‐noise ratio of 3 were 0.16, 0.47 and 0.03 µm , respectively. Furthermore validation parameters such as accuracy, precision and robustness of the proposed method showed satisfactory results. Almost 850 plasma sample injections (range 572–1076, n = 3) for a column could be performed without differences in retention time and peak heights of labels. As an application of the proposed method, the determination of thiol derivatives in normal human plasma (n = 103) was demonstrated. The correlation coefficients between Hcy vs Cys and Hcy vs CA were 0.38 and −0.35, respectively. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
Thiol‐containing amino acids (aminothiols) such as cysteine (Cys) and homocysteine (Hcy) play a key role in various biological processes including maintaining the homeostasis of biological thiols. However, abnormal levels of aminothiols are associated with a variety of diseases. The native chemical ligation (NCL) reaction has attracted great attention in the fields of chemistry and biology. NCL of peptide segments involves cascade reactions between a peptide‐α‐thioester and an N‐terminal cysteine peptide. In this work, we employed the NCL reaction mechanism to formulate a Förster resonance energy transfer (FRET) strategy for the design of ratiometric fluorescent probes that were selective toward aminothiols. On the basis of this new strategy, the ratiometric fluorescent probe 1 for aminothiols was judiciously designed. The new probe is highly selective toward aminothiols over other thiols and exhibits a very large variation (up to 160‐fold) in its fluorescence ratio (I458/I603). The new fluorescent probe is capable of ratiometric detection of aminothiols in newborn calf and human serum samples and is also suitable for ratiometric fluorescent imaging of aminothiols in living cells.  相似文献   

9.
A novel fluorescent probe was developed by integrating chlorinated coumarin and benzothiazolylacetonitrile and exploited for simultaneous detection of cysteine (Cys), homocysteine (Hcy), and glutathione (GSH). Featuring four binding sites and different reaction mechanisms for different biothiols, this probe exhibited rapid fluorescence turn‐on for distinguishing Cys, Hcy, and GSH with 108‐, 128‐, 30‐fold fluorescence increases at 457, 559, 529 nm, respectively, across different excitation wavelengths. Furthermore, the probe was successfully applied to the fluorescence imaging of endogenous Cys and GSH and exogenous Cys, Hcy, and GSH in living cells.  相似文献   

10.
Differentiation of biologically important thiols, such as cysteine (Cys), homocysteine (Hcy), and glutathione (GSH) is still a challenging task. Herein, we present a novel fluorescent chemodosimeter capable of selectively detecting Cys over other biothiols including Hcy and GSH and other amino acids by a facile thiol‐Michael addition/transcyclization rearrangement cascade click process. The unique transcyclization step is critical for the selectivity as a result of the kinetically favorable formation of a six‐membered ring with the Cys Michael adduct. Moreover, the probe adopts a distinctive dual quenching mechanism—photoinduced electron transfer (PET) and photoinduced intramolecular charge transfer (ICT) to deliver a drastic turn‐on fluorescence response only at the Cys‐selective transcylization step. The judicious selection of strong electron‐withdrawing naphthalimide fluorophore with maleimide group enhances the electrophilicity and thus reactivity for the cascade process leading to fast detection and ultrasensitivity with a detection limit of 2.0 nm (S/N=3). The probe has demonstrated its practical utility potential in Cys imaging in live cells.  相似文献   

11.
A novel fluorescent probe was developed by integrating chlorinated coumarin and benzothiazolylacetonitrile and exploited for simultaneous detection of cysteine (Cys), homocysteine (Hcy), and glutathione (GSH). Featuring four binding sites and different reaction mechanisms for different biothiols, this probe exhibited rapid fluorescence turn‐on for distinguishing Cys, Hcy, and GSH with 108‐, 128‐, 30‐fold fluorescence increases at 457, 559, 529 nm, respectively, across different excitation wavelengths. Furthermore, the probe was successfully applied to the fluorescence imaging of endogenous Cys and GSH and exogenous Cys, Hcy, and GSH in living cells.  相似文献   

12.
Background autofluorescence from biological systems generally reduces the sensitivity of a fluorescent probe for imaging biological targets. Addressing this challenge requires the development of fluorescent probes that produce emission in the near‐infrared region. Herein, we report the design and synthesis of a fluorescent probe that generates an NIR emission with a large Stokes shift upon the selective response to Cys over Hcy and GSH. The probe is designed to consist of two Cys‐sensing sites, an acrylate ester and an aldehyde installed ortho to each other. The reaction of the probe with Cys triggers an excited state intramolecular proton transfer process upon photo‐excitation, thereby producing an NIR emission with a large Stokes shift. Accordingly, this probe hold great promise for the selective detection of Cys in biological systems. We further demonstrate the capacity of this probe for Cys imaging in living cells.  相似文献   

13.
A new strategy for fast fluorescent detection of cysteine (Cys), based on a response‐assisted electrostatic attraction, is demonstrated. By utilizing this strategy, we designed and synthesized three fluorescent probes for the specific detection of Cys under actual physiological conditions. The probe m‐ CP , a coumarin fluorophore conjugated with a substituted methyl pyridinium group through an unsaturated ketone unit, showed highly selective and sensitive detection for cysteine (Cys) over homocysteine (Hcy) and glutathione (GSH). The kinetic analysis indicated that the sensing process was highly accelerated (a response time less than 1 min) by the response‐assisted electrostatic attraction. More importantly, control experiments with isomeric probes first demonstrated that the spatial charge configuration of the probe played an important role in Cys‐preferred selectivity and kinetic rate acceleration. Furthermore, the practical utility of the probe m‐ CP in the fluorescent labeling of Cys residues within proteins was demonstrated. Finally, these probes were employed in living cell imaging with HeLa cells, in which it displayed satisfactory cell permeability and enabled us to distinguish active thiols in the cytoplasm, nucleus, and mitochondria.  相似文献   

14.
《化学:亚洲杂志》2017,12(16):2098-2103
The development of a fluorescent probe to distinguish between cysteine (Cys) and homocysteine (Hcy) is always a challenge owing to their structural similarity, and the simultaneous detection of Cys and Hcy by utilizing different emission channels is especially difficult. In this work, we designed and synthesized a new fluorescent probe to differentiate between Cys and Hcy on the basis of a coumarin derivative with a chlorine atom and an α,β‐unsaturated aldehyde. Cys and Hcy induced different cascade reactions with the probe, which led to different products with distinct photophysical properties. The nonfluorescent probe responded to Cys and emitted strong blue fluorescence, whereas it reacted with Hcy and generated yellow fluorescence without interference from glutathione. In addition, the probe was successfully applied to distinguish between Cys and Hcy in living cells.  相似文献   

15.
A novel isoquinoline‐containing C^N^C ligand and its phosphorescent triphenylamine‐based alkynylgold(III) dendrimers have been synthesized. These alkynylgold(III) dendrimers serve as phosphorescent dopants in the fabrication of efficient solution‐processable organic light‐emitting devices (OLEDs). The photophysical, electrochemical, and electroluminescence properties were studied. A saturated red emission with CIE coordinates of (0.64, 0.36) and a high EQE value of 3.62 % were achieved. Unlike other red‐light‐emitting iridium(III) dendrimers, a low turn‐on voltage of less than 3 V and a reduced efficiency roll‐off at high current densities were observed; this can be accounted for by the enhanced carrier transporting ability and the relatively short lifetimes in the high‐generation dendrimers. This class of alkynylgold(III) dendrimers are promising candidates as phosphorescent dopants in the fabrication of solution‐processable OLEDs.  相似文献   

16.
We successfully developed phosphorescent cyclometallated iridium‐containing metallopolymers, which are near‐red luminescent iridium complexes bearing phosphine‐containing copolymers used as polymer ligands, and investigated their photoluminescence and electroluminescence behavior. The phosphine copolymer ligand made from methyl methacrylate and 4‐styryldiphenylphosphine can be used as an anchor, which coordinates luminescent iridium units to form the metallopolymer easily. Organic light‐emitting diodes were fabricated from the metallopolymer and its nonpolymer analog, [IrCl(piq)2PPh3]. These complexes exhibited quite similar luminescence behavior, except for emission from the free‐phosphine‐units in the polymer side chain and their energy‐transferring properties from host to guest materials. © 2009 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 47: 4366–4378, 2009  相似文献   

17.
In this work, a new simple and readily synthesized turn‐on probe 2‐(4‐anthracene‐9‐yl‐phenyl)‐ 2H‐[1,2,3]triazole‐4‐carbaldehyde (APTC) was legitimately designed towards homocysteine (Hcy). Moreover, APTC has excellent optical properties such as intramolecular charge transfer (ICT) and aggregation induced emission enhancement (AIEE) characteristics, indicating its extensive application potentiality. What's more, APTC displayed rapid, high selectivity and specificity towards homocysteine over cysteine/glutathione. The detection limit of APTC for Hcy was as low as 2.198×10–8 mol·L–1, and the response time was only 5 min. APTC has been successfully applied to detect Hcy in silica gel plates and living cells, which indicates that APTC has good stability and biocompatibility as a selective probe for Hcy. Finally, the mechanism was studied using 1H NMR titration experiments and mass spectrometry.  相似文献   

18.
Fang  Hongbao  Chen  Yuncong  Wang  Yanjun  Geng  Shanshan  Yao  Shankun  Song  Dongfan  He  Weijiang  Guo  Zijian 《中国科学:化学(英文版)》2020,63(5):699-706
Biothiols, such as cysteine(Cys) and homocysteine(Hcy), play vital roles in biological homeostasis and are closely related to various pathological and physiological processes in the living systems. Therefore, the in vivo detection of biothiols is of great importance for early diagnosis of diseases and assessment of disease progression. In this work, we developed a near-infrared(NIR) fluorescence and photoacoustic dual-modal molecular probe(NIR-S) that can be specifically activated by Cys or Hcy. The aryl-thioether substituted cyanine probe can undergo nucleophilic substitution and Smiles rearrangement reaction, resulting in specific turn-on NIR fluorescence and ratiometric photoacoustic responses for Hcy/Cys. Thus, NIR-S not only realizes the specific NIR fluorescence and photoacoustic dual mode imaging to detect Hcy/Cys in solution, but also can be applied to living cells and mice to detect Hcy/Cys. This work provided a practical tool to detect Hcy/Cys levels in vivo, which would be beneficial for the early diagnosis and progress of diseases.  相似文献   

19.
Glutathione (GSH), the most abundant intracellular biothiol, protects cellular components from damage caused by free radicals and reactive oxygen species (ROS), and plays a crucial role in human pathologies. A fluorescent probe that can selectively sense intracellular GSH would be very valuable for understanding of its biological functions and mechanisms of diseases. In this work, a 3,4‐dimethoxythiophenol‐substituted coumarin‐enone was exploited as a reaction‐type fluorescent probe for GSH based on a chloro‐functionalized coumarin‐enone platform. In the probe, the 3,4‐dimethoxythiophenol group functions not only as a fluorescence quencher through photoinduced electron transfer (PET) to ensure a low background fluorescence, but also as a reactive site for biothiols. The probe displays a dramatic fluorescence turn‐on response toward GSH with the long‐wavelength emission (600 nm) and significant Stokes shift (100 nm). The selectivity of the probe toward GSH over cysteine (Cys), homocysteine (Hcy), and other amino acids was demonstrated. Assisted by laser‐scanning confocal microscopy, we have demonstrated that the probe could specifically sense GSH over Cys/Hcy in human renal cell carcinoma SiHa cells.  相似文献   

20.
A new dual luminescent sensitive paint for barometric pressure and temperature (T) is presented. The green‐emitting iridium(III) complex [Ir(ppy)2(carbac)] (ppy=2‐phenylpyridine; carbac=1‐(9H‐carbazol‐9‐yl)‐5,5‐dimethylhexane‐2,4‐dione) was applied as a novel probe for T along with the red‐emitting complex [Ir(btpy)3], (btpy=2‐(benzo[b]thiophene‐2‐yl)pyridine) which functions as a barometric (in fact oxygen‐sensitive) probe. Both iridium complexes were dissolved in different polymer materials to achieve optimal responses. The probe [Ir(ppy)2(carbac)] was dispersed in gas‐blocking poly(acrylonitrile) microparticles in order to suppress any quenching of its luminescence by oxygen. The barometric probe [Ir(btpy)3], in turn, was incorporated in a cellulose acetate butyrate film which exhibits good permeability for oxygen. The effects of temperature on the response of the oxygen probe can be corrected by simultaneous optical determination of T, as the poly(acrylonitrile) microparticles containing the temperature indicator are incorporated into the film. The phosphorescent signals of the probes for T and barometric pressure, respectively, can be separated by optical filters due to the ≈75 nm difference in their emission maxima. The dual sensor is applicable to luminescence lifetime imaging of T and barometric pressure. It is the first luminescent dual sensor material for barometric pressure/T based exclusively on the use of IrIII complexes in combination with luminescence lifetime imaging.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号