首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到11条相似文献,搜索用时 15 毫秒
1.
Pulsed-laser crossed-beam thermal lens spectrometry within a small capillary tube has been investigated using static as well as flowing samples. It is shown that when both the excitation and probe beams are perfectly aligned, time-resolved and peak signals are adequately described by the theoretical relations previously reported for infinite samples. Depending on flow velocity and/or the lateral offset between excitation and probe beam axis, the optical element formed by the excitation beam may have a diverging or converging effect on the probe beam. However, optimization of the photothermal signal with pulsed excitation and flowing samples does not require offsetting the pump and probe beams and the peak signal is almost independent on the flow rate. The performance of the method has been checked with samples injected in a flowing stream. The response is linear over three orders of magnitude and the limit of detection obtained for cobalt nitrate in ethanol corresponds to an average absorbance of 5 x 10(-7) inside the capillary.  相似文献   

2.
Equations have been derived to predict the extent to which the sample size may be increased, without decreasing the column performance, by stationary-phase focusing at sub-ambient temperatures. Under favorable circumstances the sample size may be enhanced several hundredfold.  相似文献   

3.
This work is an extension of a communication reported by two of the authors [Carro and Herrera‐Ordoñez, Macromol Rapid Commun 2006, 27, 274], where bimodal particle size distributions (PSD), obtained by asymmetric flow‐field flow fractionation (AFFF, AF4), were taken as evidence of certain degree of stability of primary particles. Now, emulsion polymerizations of styrene were performed under conditions employed before by other researchers, intending to examine if the behavior observed is general. The number of particles (N) and PSD were studied by means of dynamic light scattering and AF4. By the later, bimodal PSDs were detected in all cases, where the population corresponding to primary particles (diameter <20 nm) depends on reaction conditions. Regarding N, AF4 results show that it is constant during interval II, in contrast to DLS results. Primary particle coagulation was evidenced as minimums in N evolution and the rate of polymerization curves, monitored by calorimetry and gravimetry, which are enhanced when higher particle number is generated and/or the ionic strength is increased. These results suggest that particle coagulation is not as extensive as it would be expected according to the coagulative theory. © 2010 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 48: 3152–3160, 2010  相似文献   

4.
A Au-Si liquid metal ion source which produces Au(n) clusters over a large range of sizes was used to study the dependence of both the molecular ion desorption yield and the damage cross-section on the size (n = 1 to 400) and on the kinetic energy (E = 10 to 500 keV) of the clusters used to bombard bioorganic surfaces. Three pure peptides with molecular masses between 750 and 1200 Da were used without matrix. [M+H](+) and [M+cation](+) ion emission yields were enhanced by as much as three orders of magnitude when bombarding with Au(400) (4+) instead of monatomic Au(+), yet very little damage was induced in the samples. A 100-fold increase in the molecular ion yield was observed when the incident energy of Au(9) (+) was varied from 10 to 180 keV. Values of emission yields and damage cross-sections are presented as a function of cluster size and energy. The possibility to adjust both cluster size and energy, depending on the application, makes the analysis of biomolecules by secondary ion mass spectrometry an extremely powerful and flexible technique, particularly when combined with orthogonal time-of-flight mass spectrometry that then allows fast measurements using small primary ion beam currents.  相似文献   

5.
A simple, sensitive and continuous on-line stacking technique using head-column (HC)-field amplified sample injection (FASI) and sweeping was developed by combination of flow injection with micellar electrokinetic chromatography. Berberine, palmatine and jatrorrhizine were selected as model mixture to demonstrate this stacking method. Based on the characteristic of a 16-way injection valve (16-V), a sample was injected electrokinetically into a capillary after the introduction of a plug of water. Under optimum conditions, 64–86-fold improvement in the detection sensitivity was obtained for the analytes and the sample throughput can reach up to 24 h−1 using the background electrolyte containing 240 mM ammonium acetate (pH 4.7), 30% (v/v) ethanol, and 2% (v/v) polyoxyethylene sorbitan monolaurate (Tween 20). The repeatabilities (n = 4) reached relative standard deviation values of 1.2, 2.7 and 3.1% for the peak areas and 1.6, 3.3 and 3.8% for peak heights of berberine, palmatine and jatrorrhizine, respectively. The limit of detection for the berberine, palmatine and jatrorrhizine was found to be 27, 26, 22 ng mL−1 (S/N = 3).  相似文献   

6.
A slurry sampling inductively coupled plasma mass spectrometry (ICP-MS) method has been developed for the determination of Ge, As, Cd, Sb, Hg and Bi in cosmetic lotions using flow injection (FI) vapor generation (VG) as the sample introduction system. A slurry containing 2% m/v lotion, 2% m/v thiourea, 0.05% m/v l-cysteine, 0.5 μg mL−1 Co(II), 0.1% m/v Triton X-100 and 1.2% v/v HCl was injected into a VG-ICP-MS system for the determination of Ge, As, Cd, Sb, Hg and Bi without dissolution and mineralization. Because the sensitivities of the analytes in the slurry and that of aqueous solution were quite different, an isotope dilution method and a standard addition method were used for the determination. This method has been validated by the determination of Ge, As, Cd, Sb, Hg and Bi in GBW09305 Cosmetic (Cream) reference material. The method was also applied for the determination of Ge, As, Cd, Sb, Hg and Bi in three cosmetic lotion samples obtained locally. The analysis results of the reference material agreed with the certified value and/or ETV-ICP-MS results. The detection limit estimated from the standard addition curve was 0.025, 0.1, 0.2, 0.1, 0.15, and 0.03 ng  g−1 for Ge, As, Cd, Sb, Hg and Bi, respectively, in original cosmetic lotion sample.  相似文献   

7.
Pulsed laser polymerization (PLP) coupled to size exclusion chromatography (SEC) is considered to be the most accurate and reliable technique for the determination of absolute propagation rate coefficients, kp. Herein, kp data as a function of temperature were determined via PLP‐SEC for three acrylate monomers that are of particular synthetic interest (e.g., for the generation of amphiphilic block copolymers). The high‐Tg monomer isobornyl acrylate (iBoA) as well as the precursor monomers for the synthesis of hydrophilic poly(acrylic acid), tert‐butyl acrylate (tBuA), and 1‐ethoxyethyl acrylate (EEA) were investigated with respect to their propagation rate coefficient in a wide temperature range. By application of a 500 Hz laser repetition rate, data could be obtained up to a temperature of 80 °C. To arrive at absolute values for kp, the Mark‐Houwink parameters of the polymers have been determined via on‐line light scattering and viscosimetry measurements. These read: K = 5.00 × 105 dL g−1, a = 0.75 (piBoA), K = 19.7 × 105 dL g−1, a = 0.66 (ptBA) and K = 1.53 × 105 dL g−1, a = 0.85 (pEEA). The bulky iBoA monomer shows the lowest propagation rate coefficient among the three monomers, while EEA is the fastest. The activation energies and Arrhenius factors read: (iBoA): log(A/L mol−1 s−1) = 7.05 and EA = 17.0 kJ mol−1; (tBuA): log(A/L mol−1 s−1) = 7.28 and EA = 17.5 kJ mol−1 and (EEA): log(A/L mol−1 s−1) = 6.80 and EA = 13.8 kJ mol−1. © 2009 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 47: 6641–6654, 2009  相似文献   

8.
9.
A microwave assisted wet digestion method for organoarsenic compounds and subsequent determination of total arsenic in aqueous, biological and sediment samples by means of flow injection hydride generation electrothermal atomic absorption spectrometry (FI-HG-ETAAS) is described. Sodium persulfate, sodium fluoride and nitric acid serve as digestion reagents, which allow a quantitative transformation of organoarsenic compounds to hydride forming species in a commercial microwave sample preparation system. The maximum operating pressures of the applied tetrafluorometoxil (TFM) liners are 75 bar (high pressure vessels) and 30 bar (medium pressure vessels), corresponding to maximum solution temperatures of 300 and 260 °C. For the investigated samples, digestion temperatures of 210-230 °C (medium pressure vessels) and 240-280 °C (high pressure vessels) were obtained.In medium pressure vessels, arsenic recovery from aqueous testing solutions of dimethylarsinic acid (DMA), phenylarsonic acid (PAA) and tetraphenylarsonium chloride (TPA) at initial concentrations of 100 and 10 μg l−1 is complete, even in the presence of an excess of organic carbon (potassium hydrogen phthalate, 2000 mg l−1) or fatty acids (linolenic acid 70%; linoleic acid ≈20-25%; Oleic acid ≈3%, 900-4500 mg l−1).Arsenic recovery from aqueous arsenobetaine (ASB) solutions with the same initial concentrations is also complete if high pressure vessels and a higher concentration of fluoride ions are used, whereas the addition of organic carbon (potassium hydrogen phthalate, 2000 mg l−1, fatty acids, 900-4500 mg l−1) leads to a decrease in arsenic recovery of about 2-5%. In all cases, residual carbon contents are close to the limit of detection for the applied analytical method (15 mg l−1).Results of arsenic analysis in reference standard materials revealed a significant dependence on the material’s nature (sediment samples, plant materials and seafood samples). Sediment samples and plant materials show recoveries for arsenic around 100% after a single-step digestion in medium pressure TFM liners. Seafood (fish/lobster/mussel samples) usually require either the use of high pressure vessels or a second digestion step, if medium pressure vessels are used.  相似文献   

10.
Overlapping peaks interfere in ion mobility spectrometry (IMS), but they are separated introducing mobility shift reagents (SR) in the buffer gas forming adducts with different collision cross‐sections (size). IMS separations using SR depend on the ion mobility shifts which are governed by adduct's size and interaction energies (stabilities). Mobility shifts of valinol and ethanolamine ions were measured by electrospray‐ionization ion mobility‐mass spectrometry (MS). Methyl‐chloro propionate (M) was used as SR; 2‐butanol (B) and nitrobenzene (N) were used for comparison. Density functional theory was used for calculations. B produced the smallest mobility shifts because of its small size. M and N have two strong interaction sites (oxygen atoms) and similar molecular mass, and they should produce similar shifts. For both ethanolamine and valinol ions, stabilities were larger for N adducts than those of M. With ethanolamine, M produced a 68% shift, large compared to that using N, 61%, because M has a third weak interaction site on the chlorine atom and, therefore, M has more interaction possibilities than N. This third site overrode the oxygen atoms' interaction energy that favored the adduction of ethanolamine with N over that with M. On the contrary, with valinol mobility shifts were larger with N than with M (21 vs 18%) because interaction energy favored even more adduction of valinol with N than with M; that is, the interaction energy difference between adducts of valinol with M and N was larger than that between those adducts with ethanolamine, and the third M interaction could not override this larger difference. Mobility shifts were explained based on the number of SR's interaction sites, size of ions and SR, and SR–ion interaction energies. This is the first time that the number of interaction sites is used to explain mobility shifts in SR‐assisted IMS. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号