首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 15 毫秒
1.
超声空化及其声流效应在医学、化工和能源等领域得到广泛应用。本文采用高速摄像和粒子图像测速系统分别研究了超声场下的空化形态和声流场结构的时空演化规律。实验研究了50W,100W,200W和250W等四种不同输入功率对18kHz的超声变幅杆附近空化及其声流场的影响。研究结果表明:(1)在变幅杆下端面处观察到由大量空化气泡均匀分布组成的倒置锥形空泡结构,并且锥形空泡结构为稳态流动结构。(2)在超声变幅杆附近产生了两种不同的声流形式,第一种是变幅杆底端的射流型声流,第二种是变幅杆两侧的回旋流。此外,通过研究空泡与声流场中最大速度点之间的空间对应关系,发现声流是因为空泡流动带动而产生的。(3)空间位置和输入功率能显著影响射流型声流的流场结构,但是对回旋流的影响十分微弱。  相似文献   

2.
Suspension culture is an essential large-scale cell culture technique for biopharmaceutical development and regenerative medicine. To transition from monolayer culture on the culture surface of a flask to suspension culture in a bioreactor, a pre-specified cell number must first be reached. During this period of preparation for suspension culture, static suspension culture in a flask is generally performed because the medium volume is not large enough to use a paddle to circulate the medium. However, drawbacks to this static method include cell sedimentation, leading to high cell density near the bottom and resulting in oxygen and nutrient deficiencies. Here, we propose a suspension culture method with acoustic streaming induced by ultrasonic waves in a T-flask to create a more homogeneous distribution of oxygen, nutrients, and waste products during the preparation period preceding large-scale suspension culture in a bioreactor. To demonstrate the performance of the ultrasonic method, Chinese hamster ovary cells were cultured for 72 h. Results showed that, on average, the cell proliferation was improved by 40% compared with the static method. Thus, the culture time required to achieve a 1000-fold increase could be reduced by 32 h (a 14% reduction) compared with the static method. Furthermore, the ultrasonic irradiation did not compromise the metabolic activity of the cells cultured using the ultrasonic method. These results demonstrate the effectiveness of the ultrasonic method for accelerating the transition to large-scale suspension culture.  相似文献   

3.
The strength of cell adhesion is important in understanding the cell’s health and in culturing them. Quantitative measurement of cell adhesion strength is a significant challenge in bioengineering research. For this, the present study describes a system that can measure cell adhesion strength using acoustic streaming induced by Lamb waves. Cells are cultured on an ultrasound transducer using a range of preculture and incubation times with phosphate-buffered saline (PBS) just before the measurement. Acoustic streaming is then induced using several Lamb wave intensities, exposing the cells to shear flows and eventually detaching them. By relying upon a median detachment rate of 50 %, the corresponding detachment force, or force of cell adhesion, was determined to be on the order of several nN, consistent with previous reports. The stronger the induced shear flow, the more cells were detached. Further, we employed a preculture time of 8 to 24 h and a PBS incubation time of 0 to 60 min, producing cell adhesion forces that varied from 1.2 to 13 nN. Hence, the developed system can quantify cell adhesion strength over a wide range, possibly offering a fundamental tool for cell-based bioengineering.  相似文献   

4.
5.
It is well known that ultrasonic cavitation causes a steady flow termed acoustic streaming. In the present study, the velocity of acoustic streaming in water and molten aluminum is measured. The method is based on the measurement of oscillation frequency of Karman vortices around a cylinder immersed into liquid. For the case of acoustic streaming in molten metal, such measurements were performed for the first time. Four types of experiments were conducted in the present study: (1) Particle Image Velocimetry (PIV) measurement in a water bath to measure the acoustic streaming velocity visually, (2) frequency measurement of Karman vortices generated around a cylinder in water, and (3) in aluminum melt, and (4) cavitation intensity measurements in molten aluminum. Based on the measurement results (1) and (2), the Strouhal number for acoustic streaming was determined. Then, using the same Strouhal number and measuring oscillation frequency of Karman vortices in aluminum melt, the acoustic streaming velocity was measured. The velocity of acoustic streaming was found to be independent of amplitude of sonotrode tip oscillation both in water and aluminum melt. This can be explained by the effect of acoustic shielding and liquid density.  相似文献   

6.
The direct finite-difference fluid simulation of acoustic streaming on a fine-meshed three-dimensional model using a graphics processing unit (GPU)-based calculation array is discussed. Airflows are induced by an acoustic traveling wave when an intense sound field is generated in a gap between a bending transducer and a reflector. The calculation results showed good agreement with measurements in a pressure distribution. Several flow vortices were observed near the boundary layer of the reflector and the transducer, which have often been observed near the boundary of acoustic tubes, but have not been observed in previous calculations for this type of ultrasonic air pump.  相似文献   

7.
In order to determine the parameters required to describe and to optimize sonochemical reactors, we have investigated the water flow inside such a reactor. With this aim, the experimental velocity field has been measured by tomography laser. The influence of certain parameters such as the electric power, the water height and the fluid viscosity has been evaluated. At the same time, the water movement has been studied theoretically using Nyborg's model. We have tried to improve this model by considering a three-dimensional velocity.  相似文献   

8.
Whilst sonothrombolysis is a promising and noninvasive ultrasound technique for treating blood clots, bleeding caused by thrombolytic agents used for dissolving clots and potential obstruction of blood flow by detached clots (i.e., embolus) are the major limitations of the current approach. In the present study, a new sonothrombolysis method is proposed for treating embolus without the use of thrombolytic drugs. Our proposed method involves (a) generating a spatially localised acoustic radiation force in a blood vessel against the blood flow to trap moving blood clots (i.e., generation of an acoustic net), (b) producing acoustic cavitation to mechanically destroy the trapped embolus, and (c) acoustically monitoring the trapping and mechanical fractionation processes. Three different ultrasound transducers with different purposes were employed in the proposed method: (1) 1-MHz dual focused ultrasound (dFUS) transducers for capturing moving blood clots, (2) a 2-MHz High Intensity Focused Ultrasound (HIFU) source for fractionating blood clots and (3) a passive acoustic emission detector with broad bandwidth (10 kHz to 20 MHz) for receiving and analysing acoustic waves scattered from a trapped embolus and acoustic cavitation. To demonstrate the feasibility of the proposed method, in vitro experiments with an optically transparent blood vessel-mimicking phantom filled with a blood mimicking fluid and a blood clot (1.2 to 5 mm in diameter) were performed with varying the dFUS and HIFU exposure conditions under various flow conditions (from 1.77 to 6.19 cm/s). A high-speed camera was used to observe the production of acoustic fields, acoustic cavitation formation and blood clot fragmentation within a blood vessel by the proposed method. Numerical simulations of acoustic and temperature fields generated under a given exposure condition were also conducted to further interpret experimental results on the proposed sonothrombolysis. Our results clearly showed that fringe pattern-like acoustic pressure fields (fringe width of 1 mm) produced in a blood vessel by the dFUS captured an embolus (1.2 to 5 mm in diameter) at the flow velocity up to 6.19 cm/s. This was likely to be due to the greater magnitude of the dFUS-induced acoustic radiation force exerted on an embolus in the opposite direction to the flow in a blood vessel than that of the drag force produced by the flow. The acoustically trapped embolus was then mechanically destructed into small pieces of debris (18 to 60 μm sized residual fragments) by the HIFU-induced strong cavitation without damaging the blood vessel walls. We also observed that acoustic emissions emitted from a blood clot captured by the dFUS and cavitation produced by the HIFU were clearly distinguished in the frequency domain. Taken together, these results can suggest that our proposed sonothrombolysis method could be used as a promising tool for treating thrombosis and embolism through capturing and destroying blood clots effectively.  相似文献   

9.
This study considers the acoustic streaming in water produced by a lithotripsy pulse. Particle image velocimetry (PIV) method was employed to visualize the acoustic streaming produced by an electromagnetic shock wave generator using video images of the light scattering particles suspended in water. Visualized streaming features including several local peaks and vortexes around or at the beam focus were easily seen with naked eyes over all settings of the lithotripter from 10 to 18 kV. Magnitudes of the peak streaming velocity measured vary in the range of 10-40 mm s(-1) with charging voltage settings. Since the streaming velocity was estimated on the basis of a series of the video images of particles averaged over 1/60s, the time resolution limited by the video frame rate which is 1-2 orders of magnitude larger than driving acoustic activities, measured velocities are expected to be underestimated and were shown a similar order of magnitude lower than those calculated from a simple theoretical consideration. Despite such an underestimation, it was shown that, as predicted by theory, the magnitude of the streaming velocity measured by the present PIV method was proportional to acoustic intensity. In particular it has almost a linear correlation with peak negative pressures (r=0.98683, p=0.0018).  相似文献   

10.
Ultrasound is an emerging and promising method for demulsification, which is highly affected by acoustic parameters and emulsion properties. Herein, a series of microscopic and dehydration experiments are carried out to investigate the parameter optimization of ultrasonic separation. The results show that the optimal acoustic parameters highly depend on the emulsion properties. For low frequency ultrasonic standing waves (USWs), mechanical vibrations not only facilitate droplet collision and coalescence, but also disperse the surfactant absorbed on the interface to decrease the interfacial strength. Therefore, low frequency ultrasound is suitable for separating emulsions with high viscosity and high interfacial strength. Increasing the energy density to produce moderate cavitation can increase demulsification efficiency. However, excessive cavitation results in secondary emulsification. In high frequency USWs, the droplets migrate directionally and form bandings, thereby promoting droplet coalescence. Therefore, high frequency ultrasound is favorable for separating emulsions with low dispersed phase content and small droplet size. Increasing the energy density can accelerate the aggregation of droplets, however, excessive energy density causes acoustic streaming that disturbs the aggregated droplets, resulting in reduced demulsification efficiency. This work presents rules for acoustic parameter optimization, further advancing industrial applications of ultrasonic separation.  相似文献   

11.
I.IntroductionUptonowtheultrasonicpu1seechotechniquehasbeenwide1yusedinthefieldofnon-destructivetesting.Toachievehightargetreso1ution,narrowpu1seshou1dbeadoptcd.Butthiswill1imitthetransmitpowerandthcdetectab1erange,whichisveryboportantcspecia1lyinthemediumwithstrongacousticattenuation.Itmeansthatthetargetresolutionanddetcctablerangehavccontradictorydcmands.Thcrcforethepulsccompressionandcorre1ationtechniqucdeve1opedinradarsystemhavebeenintroducedintotheultrasonicNDTandsomeprogresseshavebeenp…  相似文献   

12.
利用有限元方法研究了有限长换能器激发的超声波在套管井多层介质中的传播规律。数值模拟了换能器长度及套管曲率对反射回波的影响。随着换能器长度增加,反射回波频谱谱陷个数由单一向多个变化;套管共振透射窗的反射波相对能量先逐渐减小后振荡变化,较小长度的换能器对套管与水泥环界面的声阻抗区分能力优于较大长度的换能器。随着套管曲率的增大,套管共振透射窗的反射波由单一模式的厚度振动纵波向其他模式波变化。数值模拟结果对超声脉冲反射声波测井仪器的换能器结构优化设计起到了良好的指导作用。  相似文献   

13.
m伪随机序列在声相关计程仪中的应用研究   总被引:1,自引:0,他引:1       下载免费PDF全文
本文通过立声相关计程仪的海底混响回波模型,将脉冲信号调制在伪随机序列中作为发射信号,对在低航 速下的声相关测速性能进行了计算机仿真研究。  相似文献   

14.
This paper presents a resonant technique to accurately measure phase-velocity and attenuation of longitudinal acoustic waves in suspensions of solid particles in water. The technique is based on exciting thickness resonances of a layer of fluid and analyzing its spectrum. To this end, a resonant cell to contain the fluid is described and used. Two different type of water suspensions are studied: titanium dioxide and alumina particles; particle volume fraction is in the range 0–0.18. Simultaneous determination of particle size distribution in the suspension by an optical method are also carried out. Finally, the experimental results are compared with theoretical predictions obtained from three different approaches.  相似文献   

15.
16.
Wei Wang 《中国物理 B》2022,31(9):94302-094302
Acoustic orbital angular momentum (OAM) associated with helicoidal wavefront recently attracts rapidly-growing attentions, offering a new degree of freedom for acoustic manipulation. Due to the unique dynamical behavior and inherent mode orthogonality of acoustic OAM, its harnessing is of fundamental interests for wave physics, with great potential in a plethora of applications. The recent advance in materials physics further boosts efforts into controlling OAM-carrying acoustic vortices, especially acoustic metasurfaces with planar profile and subwavelength thickness. Thanks to their unconventional acoustic properties beyond attainable in the nature, acoustic artificial structures provide a powerful platform for new research paradigm for efficient generation and diverse manipulation of OAM in ways not possible before, enabling novel applications in diverse scenarios ranging from underwater communication to object manipulation. In this article, we present a comprehensive view of this emerging field by delineating the fundamental physics of OAM-metasurface interaction and recent advances in the generation, manipulation, and application of acoustic OAM based on artificial structures, followed by an outlook for promising future directions and potential practical applications.  相似文献   

17.
Mode conversions of Lamb waves can occur upon encountering damage or defect such as a notch, leading to newly-converted modes apart from wave reflection and transmission. In this paper, the transmission of the fundamental Lamb modes symmetrical S0 and anti-symmetrical A0 with anti-symmetrical notches were investigated in steel plates within the relatively short propagation distance. The group velocity and modal energy of the converted modes were analyzed using simulations and experiments. Two-dimensional finite difference time domain (2D-FDTD) method was employed to calculate the scattering field and extract numerical trends for simulation study and experimental confirmation. Both simulations and experiments revealed that the apparent group velocities of the converted modes in the transmitted signals subject to the notch positions. To describe the mode conversion degree and evaluate the notch severity, wave packets of the originally-transmitted modes and newly-converted modes were separated and corresponding mode energy percentages were analyzed at different notch severities. Frequency-sweeping measurements illustrated that the modal energy percentages varied monotonically over the notch-depth increase with a statistically consistency (R = 1.00, P < 0.0004).  相似文献   

18.
In many technical applications, like supersonic jets, noise with a characteristic spectrum including certain dominant frequencies (e.g. jet-screech) is prevalent, and the elimination of sharp peaks in the acoustic spectrum is the aim of active or passive flow/noise control efforts. A mathematical framework for the optimization of control strategies is introduced that uses a cost objective in frequency-space coupled to constraints in form of partial differential equations in the time domain. An iterative optimization scheme based on direct and adjoint equations arises, which has been validated on two examples, the one-dimensional Burgers equation and the two-dimensional compressible Navier–Stokes equations. In both cases, the iterative scheme has proven effective and efficient in targeting and removing specified frequency bands in the acoustic spectrum. It is expected that this technique will find use in acoustic and other applications where the elimination or suppression of distinct frequency components is desirable.  相似文献   

19.
Detection of glutathione (GSH) is technically challenging at clinical field strengths of 1.5 or 3 T due to its low concentration in the human brain coupled with the fact that conventional single-echo acquisitions, typically used for magnetic resonance (MR) spectroscopy acquisitions, cannot be used to resolve GSH given its overlap with other resonances. In this study, an MR spectral editing scheme was used to generate an unobstructed detection of GSH at 7 T. This technique was used to obtain normative white (WM) and gray matter (GM) GSH concentrations over a two-dimensional region. Results indicated that GSH was significantly higher (P<.001) in GM relative to WM in normal subjects. This finding is consistent with previous radionuclide experiments and histochemical staining and validates this 7 T MR spectroscopy technique. To our knowledge, this is the first study to report normative differences in WM and GM glutathione concentrations in the human brain. Glutathione is a biomarker for oxidative status and this non-invasive in vivo measurement of GSH was used to explore its sensitivity to oxidative state in multiple sclerosis (MS) patients. There was a significant reduction (P<.001) of GSH between the GM in MS patients and normal controls. No statistically significant GSH differences were found between the WM in controls and MS patients. Reduced GSH was also observed in a MS WM lesion. This preliminary investigation demonstrates the potential of this marker to probe oxidative state in MS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号