首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Agarwal A  Yoo YM  Schneider FK  Kim Y 《Ultrasonics》2008,48(5):384-393
Quadrature demodulation-based phase rotation beamforming (QD-PRBF) is commonly used to support dynamic receive focusing in medical ultrasound systems. However, it is computationally demanding since it requires two demodulation filters for each receive channel. To reduce the computational requirements of QD-PRBF, we have previously developed two-stage demodulation (TSD), which reduces the number of lowpass filters by performing demodulation filtering on summation signals. However, it suffers from image quality degradation due to aliasing at lower beamforming frequencies. To improve the performance of TSD-PRBF with reduced number of beamforming points, we propose a new adaptive field-of-view (AFOV) imaging method. In AFOV imaging, the beamforming frequency is adjusted depending on displayed FOV size and the center frequency of received signals. To study its impact on image quality, simulation was conducted using Field II, phantom data were acquired from a commercial ultrasound machine, and the image quality was quantified using spatial (i.e., axial and lateral) and contrast resolution. The developed beamformer (i.e., TSD-AFOV-PRBF) with 1024 beamforming points provided comparable image resolution to QD-PRBF for typical FOV sizes (e.g., 4.6% and 1.3% degradation in contrast resolution for 160 mm and 112 mm, respectively for a 3.5 MHz transducer). Furthermore, it reduced the number of operations by 86.8% compared to QD-PRBF. These results indicate that the developed TSD-AFOV-PRBF can lower the computational requirement for receive beamforming without significant image quality degradation.  相似文献   

2.

Motivation

Commercial ultrasound machines in the past did not provide the ultrasound researchers access to raw ultrasound data. Lack of this ability has impeded evaluation and clinical testing of novel ultrasound algorithms and applications.

Objectives

Recently, we developed a flexible ultrasound back-end where all the processing for the conventional ultrasound modes, such as B, M, color flow and spectral Doppler, was performed in software. The back-end has been incorporated into a commercial ultrasound machine, the Hitachi HiVision 5500. The goal of this work is to develop an ultrasound research interface on the back-end for acquiring raw ultrasound data from the machine.

Methods

The research interface has been designed as a software module on the ultrasound back-end. To increase the amount of raw ultrasound data that can be spooled in the limited memory available on the back-end, we have developed a method that can losslessly compress the ultrasound data in real time.

Results and discussion

The raw ultrasound data could be obtained in any conventional ultrasound mode, including duplex and triplex modes. Furthermore, use of the research interface does not decrease the frame rate or otherwise affect the clinical usability of the machine. The lossless compression of the ultrasound data in real time can increase the amount of data spooled by ∼2.3 times, thus allowing more than 6 s of raw ultrasound data to be acquired in all the modes. The interface has been used not only for early testing of new ideas with in vitro data from phantoms, but also for acquiring in vivo data for fine-tuning ultrasound applications and conducting clinical studies. We present several examples of how newer ultrasound applications, such as elastography, vibration imaging and 3D imaging, have benefited from this research interface. Since the research interface is entirely implemented in software, it can be deployed on existing HiVision 5500 ultrasound machines and may be easily upgraded in the future.

Conclusions

The developed research interface can aid researchers in the rapid testing and clinical evaluation of new ultrasound algorithms and applications. Additionally, we believe that our approach would be applicable to designing research interfaces on other ultrasound machines.  相似文献   

3.
Schneider FK  Yoo YM  Agarwal A  Koh LM  Kim Y 《Ultrasonics》2006,44(3):265-271
In this paper, we present a new quadrature demodulation filter to reduce hardware complexity in digital phase rotation beamforming. Due to its low sensitivity to phase delay errors, digital quadrature demodulation is commonly used in ultrasound machines. However, since it requires two lowpass filters for each channel to remove harmonics, the direct use of conventional finite impulse response (FIR) filters in ultrasound machines is computationally expensive and burdensome. In our new method, an efficient multi-stage uniform coefficient (MSUC) filter is utilized to remove harmonic components in phase rotation beamforming. In comparison with the directly implemented FIR (DI-FIR) and the previously-proposed signed-power-of-two FIR (SPOT-FIR) lowpass filters, the proposed MSUC filter reduces the necessary hardware resources by 93.9% and 83.9%, respectively. In simulation, the MSUC filter shows a negligible degradation in image quality. The proposed method resulted in comparable spatial and contrast resolution to the DI-FIR approach in the phantom study. These preliminary results indicate that the proposed quadrature demodulation filtering method could significantly reduce the hardware complexity in phase rotation beamforming while maintaining comparable image quality.  相似文献   

4.
I.lntroductionltiswellknownthatthebeamformingisakeylinkinthesignalprocessingsystemofsonar,radar,exPlorationofundergroundresouxces,monitoringofseismicwaveandsoonref.[1-4].owingtotheofthelimitedspace,thispapermainlydiscussesthebeamforminginvolvedinsonarsystem.Regardlessofthepassiveoractivesonar,analogordigitalsonar,theremustbeabeamformingsystem,thepurposeistoacquirethehigherspatialgain,andinthemeantime,toobtaintheresolutionwithhigherprecisionforthesystem.So,thebeamformingsystemisa8igIilficanfact…  相似文献   

5.
This work reports the potential use of high-overtone self-focusing acoustic transducers for high-frequency ultrasonic Doppler. By using harmonic frequencies of a thick bulk Lead Zirconate Titanate (PZT) transducer with a novel air-reflector Fresnel lens, we obtained strong ultrasound signals at 60 MHz (3rd harmonic) and 100 MHz (5th harmonic). Both experimental and theoretical analysis has demonstrated that the transducers can be applied to Doppler systems with high frequencies up to 100 MHz.  相似文献   

6.
The primary objective of this work was to develop and optimize the calibration techniques for ultrasonic hydrophone probes used in acoustic field measurements up to 100 MHz. A dependable, 100 MHz calibration method was necessary to examine the behavior of a sub-millimeter spatial resolution fiber optic (FO) sensor and assess the need for such a sensor as an alternative tool for high frequency characterization of ultrasound fields. Also, it was of interest to investigate the feasibility of using FO probes in high intensity fields such as those employed in HIFU (high intensity focused ultrasound) applications. In addition to the development and validation of a novel, 100 MHz calibration technique the innovative elements of this research include implementation and testing of a prototype FO sensor with an active diameter of about 10 μm that exhibits uniform sensitivity over the considered frequency range and does not require any spatial averaging corrections up to about 75 MHz. The results of the calibration measurements are presented and it is shown that the optimized calibration technique allows the sensitivity of the hydrophone probes to be determined as a virtually continuous function of frequency and is also well suited to verify the uniformity of the FO sensor frequency response. As anticipated, the overall uncertainty of the calibration was dependent on frequency and determined to be about ±12% (±1 dB) up to 40 MHz, ±20% (±1.5 dB) from 40 to 60 MHz and ±25% (±2 dB) from 60 to 100 MHz. The outcome of this research indicates that once fully developed and calibrated, the combined acousto-optic system will constitute a universal reference tool in the wide, 100 MHz bandwidth.  相似文献   

7.
Jeong JS  Chang JH  Shung KK 《Ultrasonics》2012,52(6):730-739
In an ultrasound image-guided High Intensity Focused Ultrasound (HIFU) surgery, reflected HIFU waves received by an imaging transducer should be suppressed for real-time simultaneous imaging and therapy. In this paper, we investigate the feasibility of pulse compression scheme combined with notch filtering in order to minimize these HIFU interference signals. A chirp signal modulated by the Dolph-Chebyshev window with 3-9 MHz frequency sweep range is used for B-mode imaging and 4 MHz continuous wave is used for HIFU. The second order infinite impulse response notch filters are employed to suppress reflected HIFU waves whose center frequencies are 4 MHz and 8 MHz. The prototype integrated HIFU/imaging transducer that composed of three rectangular elements with a spherically con-focused aperture was fabricated. The center element has the ability to transmit and receive 6 MHz imaging signals and two outer elements are only used for transmitting 4 MHz continuous HIFU wave. When the chirp signal and 4 MHz HIFU wave are simultaneously transmitted to the target, the reflected chirp signals mixed with 4 MHz and 8 MHz HIFU waves are detected by the imaging transducer. After the application of notch filtering with pulse compression process, HIFU interference waves in this mixed signal are significantly reduced while maintaining original imaging signal. In the single scanline test using a strong reflector, the amplitude of the reflected HIFU wave is reduced to −45 dB. In vitro test, with a sliced porcine muscle shows that the speckle pattern of the restored B-mode image is close to that of the original image. These preliminary results demonstrate the potential for the pulse compression scheme with notch filtering to achieve real-time ultrasound image-guided HIFU surgery.  相似文献   

8.
FeSiBNb amorphous powder cores were prepared with the amorphous powder by gas atomization and subsequent hot pressing of resulting powder after creating oxide layers on the amorphous powder. Fully amorphous FeSiBNb powders with good soft magnetic properties were successfully obtained in the particle size range below 100 μm. FeSiBNb amorphous powder cores exhibit stable permeability up to 10 MHz, showing excellent high-frequency characteristics.  相似文献   

9.
Yoon C  Lee Y  Chang JH  Song TK  Yoo Y 《Ultrasonics》2011,51(7):795-802
Effective receive beamforming in medical ultrasound imaging is important for enhancing spatial and contrast resolution. In current ultrasound receive beamforming, a constant sound speed (e.g., 1540 m/s) is assumed. However, the variations of sound speed in soft tissues could introduce phase distortions, leading to degradation in spatial and contrast resolution. This degradation becomes even more severe in imaging fatty tissues (e.g., breast) and with obese patients. In this paper, a mean sound speed estimation method where phase variance of radio-frequency channel data in the region of interest is evaluated is presented for improving spatial and contrast resolution. The proposed estimation method was validated by the Field II simulation and the tissue mimicking phantom experiments. In the simulation, the sound speed of the medium was set to 1450 m/s and the proposed method was capable of capturing this value correctly. From the phantom experiments, the −18-dB lateral resolution of the point target at 50 mm obtained with the estimated mean sound speed was improved by a factor of 1.3, i.e., from 3.9 mm to 2.9 mm. The proposed estimation method also provides an improvement of 0.4 in the contrast-to-noise ratio, i.e., from 2.4 to 2.8. These results indicate that the proposed mean sound speed estimation method could enhance the spatial and contrast resolution in the medical ultrasound imaging systems.  相似文献   

10.
The objective of the study was to acoustically characterize trisacryl polymeric microparticles (TMP), which are derived from biocompatible embolic agents.With significant acoustic properties, these polymeric particles could be potentially used as targeted ultrasound contrast agents, directed towards a specific site, with ligands conjugation on the polymeric network surface. In the in vitro study, a pulser/receiver (PRF of 1 kHz), associated to different transducers (5, 10 and 15 MHz), was used to measure the acoustic properties of the TMP inserted in a Couette flow device. Acoustic characterization according to TMP concentration (0.12-15.63 mg/ml), frequency (4.5-17 MHz, defined by each transducer bandwidth), ultrasound pressure (137-378 kPa) and exposure time (0-30 min) was conducted. Particle attenuation was also evaluated according to TMP concentration and emission frequency. Backscattering increased non linearly with concentration and maximum enhancement was of 16.4 dB ± 0.89 dB above 7.8 mg/ml. This parameter was found non-linear with increasing applied pressure and no harmonic oscillation could be noticed. Attenuation reached approximately 1.4 dB/cm at 15 MHz and for the 15.6 mg/ml suspension.The TMP have revealed in vitro ultrasound properties comparable to those observed with known contrast agents, studied in similar in vitro systems. However, such set-ups combined with a rather aqueous suspending medium, have some limitations and further investigations need now to be conducted to approach in vivo conditions in terms of flow and blood environment.  相似文献   

11.
Magnetic labeling of living cells creates opportunities for numerous biomedical applications. Here we describe an instantly cell magnetic labeling method based on ultrasound. We present a detailed study on the ultrasound performance of a simple and efficient labeling protocol for H-22 cells in vitro. High frequency focus ultrasound was investigated as an alternative method to achieve instant cell labeling with the magnetic particles without the need for adjunct agents or initiating cell cultures. Mean diameter of 168 nm dextran-T40 coated superparamagnetic iron oxide (SPIO) nanoparticles were prepared by means of classical coprecipitation in solution in our laboratory. H-22 tumor cells suspended in phosphate-buffered saline (PBS, pH=7.2) were exposed to ultrasound at 1.37 MHz for up to 120 s in the presence of SPIOs. The cellular uptake of iron oxide nanoparticles was detected by prussion blue staining. The viability of cells was determined by a trypan blue exclusion test. At 2 W power and 60 s ultrasound exposure in presence of 410 μg/ml SPIOs, H-22 cell labeling efficiency reached 69.4±6.3% and the labeled cells exhibited an iron content of 10.38±2.43 pg per cell. Furthermore, 95.2±3.2% cells remained viable. The results indicated that the ultrasound protocol could be potentially applied to label cells with large-sized magnetic particles. We also calculated the shear stress at the 2 W power and 1.37 MHz used in experiments. The results showed that the shear stress threshold for ultrasonically induced H-22 cell reparable sonoporation was 697 Pa. These findings provide a quantitative guidance in designing ultrasound protocols for cell labeling.  相似文献   

12.
We propose a novel dispersion-based optical beamforming network scheme employing phase modulation and direct detection. Optical phase modulators have the advantages of simple-structure, low loss and absence of bias. Dispersion-induced phase-to-intensity conversion is utilized to facilitate direct detection. A structure of wideband dispersive device (WDD) cascaded with periodic dispersive device (PDD) is introduced to enhance the system flexibility, so that the delay adjustability and RF response can be properly designed respectively by choosing appropriate dispersions of the WDD and PDD. A concept-proof system with a wideband chirped fiber grating (CFG) as the WDD and two multiband CFGs (MCFG1 and MCFG2) as the PDD separately is built to demonstrate the basic idea. The delay tuning range is 0-1.8 ns with increment of 164.2 ps. The passband center is 30 GHz for MCFG1 and 20 GHz for MCFG2, and the fractional bandwidth is 51.8%. The shot-noise-limited spurious-free dynamic range is also analyzed and measured to be 105.7 dB ⋅ Hz2/3 when the average photocurrent is 2.7 mA.  相似文献   

13.
Tsui PH  Wang SH  Huang CC 《Ultrasonics》2005,43(7):560-565
The effect of ultrasound at various energy levels on the conduction properties of neural tissue is explored in this in vitro study. Excised sciatic nerves from the bullfrog were used for experiments. The nerves were stimulated by 3.5 MHz continuous wave ultrasound at 1, 2, and 3 W for 5 min. The peak-to-peak amplitude of the electrically evoked compound action potential (CAP) and the conduction velocity (CV) were measured in the nerves before and during ultrasound stimulation. The CV of the nerves increased by 5-20% for ultrasound stimulations at 1-3 W. The CAP amplitude increased by 8% during stimulation with 1 W ultrasound, and progressively decreased for 2 and 3 W ultrasound. This indicates that the effect of lower energy ultrasound increases both the CV and the CAP amplitude and that the reduction in the CAP amplitude for higher energy ultrasound is associated largely with ultrasonic thermal effects.  相似文献   

14.
Moisturizing creams and lotions are commonly used in daily life for beauty and treatment of different skin conditions such as dryness and wrinkling, and ultrasound stimulation has been used to enhance the delivery of ingredients into skin. However, there is a lack of convenient methods to study the effect of ultrasound stimulation on lotion absorption by skin in vivo. Ultrasound biomicroscopy was adopted as a viable tool in this study to investigate the effectiveness of ultrasound stimulation on the enhancement of lotion delivery into skin. The forearm skin of 10 male and 10 female young subjects was tested at three different sites, including two lotion treatment sites with (Ultrasound Equipment – UE ON) and without (UE OFF) ultrasound stimulation and a control site without any lotion treatment. 1 MHz ultrasound with a duty cycle of 1.7%, a spatial peak temporal peak pressure of 195 kPa and an average power of 0.43 W was used for the stimulation. The skin thickness before, immediately after (0 min), and 15 and 30 min after the treatment was measured by an ultrasound biomicroscopic system (55 MHz). It was found that the skin thickness significantly increased immediately after the lotion treatment for both UE ON (from 1.379 ± 0.187 mm to 1.466 ± 0.182 mm, p < 0.001) and UE OFF (from 1.396 ± 0.193 mm to 1.430 ± 0.194 mm, p < 0.001) groups. Further comparison between the two groups revealed that the skin thickness increase of UE ON group was significantly larger than that of UE OFF group (6.5 ± 2.4% vs. 2.5 ± 1.3%, p < 0.001). Furthermore, it was disclosed that the enhancement of lotion delivery by ultrasound stimulation was more effective for the female subjects than the male subjects (7.6 ± 2.3% vs. 5.4 ± 2.0% immediately after treatment, = 0.017). In conclusion, this study demonstrated that ultrasound biomicroscopy was a feasible method for studying the effectiveness of lotion treatment in vivo, and ultrasound stimulation was effective to enhance the rate of lotion absorption into skin.  相似文献   

15.
Phospholipid encapsulated microbubbles are widely employed as clinical diagnostic ultrasound contrast agents in the 1–5 MHz range, and are increasingly employed at higher ultrasound transmit frequencies. The stiffness and viscosity of the encapsulating “shells” have been shown to play a central role in determining both the linear and nonlinear response of microbubbles to ultrasound. At lower frequencies, recent studies have suggested that shell properties can be frequency dependent. At present, there is only limited knowledge of how the viscoelastic properties of phospholipid shells scale at higher frequencies. In this study, four batches of in-house phospholipid encapsulated microbubbles were fabricated with decreasing volume-weighted mean diameters of 3.20, 2.07, 1.82 and 1.61 μm. Attenuation experiments were conducted in order to assess the frequency-dependent response of each batch, resulting in resonant peaks in response at 4.2, 8.9, 12.6 and 19.5 MHz, respectively. With knowledge of the size measurements, the attenuation spectra were then fitted with a standard linearized bubble model in order to estimate the microbubble shell stiffness Sp and shell viscosity Sf, resulting in a slight increase in Sp (1.53–1.76 N/m) and a substantial decrease in Sf (0.29 × 106–0.08 × 10−6 kg/s) with increasing frequency. These results performed on a single phospholipid agent show that frequency dependent shell properties persist at high frequencies (up to 19.5 MHz).  相似文献   

16.
Optical homodyne receivers based on modified balanced optical phase-locked loop is analyzed taking into account loop propagation delay. This modified loop contains all the components of a standard BOPLL in conjunction of an additional phase modulator. This modified loop offers a much improved tracking performance and also shows good improvements in the reduction performance over previously reported methods, like, relaxed line-width requirement and improved lock-in range. This study for the first time shows the imperfect-phase-recovery-induced power penalty as a function of laser line-width with the optimum phase deviations in the presence of non-negligible loop propagation delay. It is found that in order to maintain a 10−10 BER system performance with ξ = 1, R = 1 A/W, PR = −53 dBm, Δυ = 1 MHz, phase modulator sensitivity KPM = 10 rad/V and 10° phase deviation between the two transmitted bits, the loop delay must be kept below 3 ns. Further, the required line-width with the non-negligible loop delay time is evaluated and found to be (2.1 × 10−3)/τ, where τ (s) is the loop delay. This number corresponds to BER = 10−10, imperfect phase recovery power penalty of 1 dB and phase modulator sensitivity KPM = 20 rad/V.  相似文献   

17.

Objective and motivation

The goal of this work was to test experimentally that exposing air bubbles or ultrasound contrast agents in water to amplitude modulated wave allows control of inertial cavitation affected volume and hence could limit the undesirable bioeffects.

Methods

Focused transducer operating at the center frequency of 10 MHz and having about 65% fractional bandwidth was excited by 3 μs 8.5 and 11.5 MHz tone-bursts to produce 3 MHz envelope signal. The 3 MHz frequency was selected because it corresponds to the resonance frequency of the microbubbles used in the experiment. Another 5 MHz transducer was used as a receiver to produce B-mode image. Peak negative acoustic pressure was adjusted in the range from 0.5 to 3.5 MPa. The spectrum amplitudes obtained from the imaging of SonoVueTM contrast agent when using the envelope and a separate 3 MHz transducer were compared to determine their cross-section at the - 6 dB level.

Results

The conventional 3 MHz tone-burst excitation resulted in the region of interest (ROI) cross-section of 2.47 mm while amplitude modulated, dual-frequency excitation with difference frequency of 3 MHz produced cross-section equal to 1.2 mm.

Conclusion

These results corroborate our hypothesis that, in addition to the considerably higher penetration depth of dual-frequency excitation due to the lower attenuation at 3 MHz than that at 8.5 and 11.5 MHz, the sample volume of dual-frequency excitation is also smaller than that of linear 3-MHz method for more spatially confined destruction of microbubbles.  相似文献   

18.
High performance limiters are described in this paper for applications in high frequency ultrasound imaging systems. Limiters protect the ultrasound receiver from the high voltage (HV) spikes produced by the transmitter. We present a new bipolar power transistor (BPT) configuration and compare its design and performance to a diode limiter used in traditional ultrasound research and one commercially available limiter. Limiter performance depends greatly on the insertion loss (IL), total harmonic distortion (THD) and response time (RT), each of which will be evaluated in all the limiters. The results indicated that, compared with commercial limiter, BPT-based limiter had less IL (−7.7 dB), THD (−74.6 dB) and lower RT (43 ns) at 100 MHz. To evaluate the capability of these limiters, they were connected to a 100 MHz single element transducer and a two-way pulse-echo test was performed. It was found that the −6 dB bandwidth and sensitivity of the transducer using BPT-based limiter were better than those of the commercial limiter by 22% and 140%, respectively. Compared to the commercial limiter, BPT-based limiter is shown to be capable of minimizing signal attenuation, RT and THD at high frequencies and is thus suited for high frequency ultrasound applications.  相似文献   

19.
Miniature flat ultrasound transducers have shown to be effective for a large variety of thermal therapies, but the associated superficial heating implicates developing original strategies in order to extend therapeutic depth. The goal of the present paper is to use ultrasound contrast agents (UCA) to increase remote attenuation and heating. Theoretical simulations demonstrated that increasing attenuation from 0.27 to 0.8 Np/cm at 10 MHz beyond a distance of 18 mm from the transducer should result in longer thermal damages due to protein coagulation in a tissue mimicking phantom. Contrast agents (BR14, Bracco, Plan-les-Ouates, Switzerland) were embedded in thermo-sensitive gel and attenuations ranging from 0.27 to 1.33 Np/cm were measured at 10 MHz for concentrations of BR14 between 0 and 4.8%. Thermal damages were then induced in several gels, which had different layering configurations. Thermal damages, 12.8 mm in length, were obtained in homogeneous gels. When mixing contrast agents at a concentration of 3.2% beyond a first 18 mm-thick layer of homogeneous gel, the thermal damages reached 21.5 mm in length. This work demonstrated that contrast agents can be used for increasing attenuation remotely and extending therapeutic depth induced by a non-focused transducer. Additional work must be done in vivo in order to verify the remote-only distribution of bubbles and associated increase in attenuation.  相似文献   

20.
This paper focuses on the use of poly (vinyl alcohol)-shelled microbubbles as a contrast agent in ultrasound medical imaging. The objective was an in vitro assessment of the different working conditions and signal processing methods for the visual detection (especially in small vessels) of such microbubbles, while avoiding their destruction. Polymer-shelled microbubbles have recently been proposed as ultrasound contrast agents with some important advantages. The major drawback is a shell that is less elastic than that of the traditional lipidic microbubbles. Weaker echoes are expected, and their detection at low concentrations may be critical. In vitro experiments were performed with a commercial ultrasound scanner equipped with a dedicated acquisition board. A concentration of 100 bubbles/mm3, excitation pressure amplitudes from 120 kPa to 320 kPa, and a central frequency of 3 MHz or 4.5 MHz were used. Three multi-pulse techniques (i.e., pulse inversion, contrast pulse sequence based on three transmitted signals, and contrast pulse sequence in combination with the chirp pulse) were compared. The results confirmed that these microbubbles produce a weaker ultrasound response than lipidic bubbles with a reduced second-order nonlinear component. Nevertheless, these microbubbles can be detected by the contrast pulse sequence technique, especially when the chirp pulse is adopted. The best value of the contrast-to-tissue ratio was obtained at an excitation pressure amplitude of 230 kPa: although this pressure amplitude is higher than what is typically used for lipidic microbubbles, it does not cause the rupture of the polymeric contrast agent.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号