共查询到5条相似文献,搜索用时 15 毫秒
1.
Visualizing and analyzing the morphological structure of carotid bifurcations are important for understanding the etiology of carotid atherosclerosis, which is a major cause of stroke and transient ischemic attack. For delineation of vasculatures in the carotid artery, ultrasound examinations have been widely employed because of a noninvasive procedure without ionizing radiation. However, conventional 2D ultrasound imaging has technical limitations in observing the complicated 3D shapes and asymmetric vasodilation of bifurcations. This study aims to propose image-processing techniques for better 3D reconstruction of a carotid bifurcation in a rat by using 2D cross-sectional ultrasound images. A high-resolution ultrasound imaging system with a probe centered at 40 MHz was employed to obtain 2D transversal images. The lumen boundaries in each transverse ultrasound image were detected by using three different techniques; an ellipse-fitting, a correlation mapping to visualize the decorrelation of blood flow, and the ellipse-fitting on the correlation map. When the results are compared, the third technique provides relatively good boundary extraction. The incomplete boundaries of arterial lumen caused by acoustic artifacts are somewhat resolved by adopting the correlation mapping and the distortion in the boundary detection near the bifurcation apex was largely reduced by using the ellipse-fitting technique. The 3D lumen geometry of a carotid artery was obtained by volumetric rendering of several 2D slices. For the 3D vasodilatation of the carotid bifurcation, lumen geometries at the contraction and expansion states were simultaneously depicted at various view angles. The present 3D reconstruction methods would be useful for efficient extraction and construction of the 3D lumen geometries of carotid bifurcations from 2D ultrasound images. 相似文献
2.
In this paper we propose a skin-scanning technique with a high-frequency ultrasound imaging system that enables images to be acquired at the fixed depth of field of a single-element focused transducer along the profile of an object contour by simultaneously moving the transducer in the horizontal and vertical directions. The scanning path, which closely parallels the profile of the object contour, was determined from the intensity difference between an object and the background in a brightness-mode image. The transducer moved along the profile of the object contour while maintaining a constant distance interval between adjacent pairs of ultrasonic signals in the horizontal direction. The image was then reconstructed by applying an alignment process to eliminate the distortion. The performance of skin-scanning technique was verified in vitro experiment using an arc-shaped phantom and the results showed a percentage error of 0.55% for the volumetric blood flow estimates. Moreover, in vivo experiment on a subcutaneous tumor was also performed. The results indicated that the proposed technique can accurately estimate the blood flow information along the profile of the object contour and avoid distortion of the morphology of blood vessels. The skin-scanning technique has potential for assessing superficial blood flows and prognoses in the oncology and dermatology fields. 相似文献
3.
A multimodal nonlinear optical imaging system that integrates coherent anti-Stokes Raman scattering (CARS), sum-frequency generation (SFG), and two-photon excitation fluorescence (TPEF) on the same platform was developed and applied to visualize single cells and extracellular matrix in fresh carotid arteries. CARS signals arising from CH2-rich membranes allowed visualization of endothelial cells and smooth muscle cells of the arterial wall. Additionally, CARS microscopy allowed vibrational imaging of elastin and collagen fibrils which are also rich in CH2 bonds. The extracellular matrix organization was further confirmed by TPEF signals arising from elastin’s autofluorescence and SFG signals arising from collagen fibrils’ non-centrosymmetric structure. Label-free imaging of significant components of arterial tissues suggests the potential application of multimodal nonlinear optical microscopy to monitor onset and progression of arterial diseases. 相似文献
4.
Full field laser Doppler imaging (LDI) and single exposure laser speckle contrast imaging (LSCI) are directly compared using a novel instrument which can concurrently image blood flow using both LDI and LSCI signal processing. Incorporating a commercial CMOS camera chip and a field programmable gate array (FPGA) the flow images of LDI and the contrast maps of LSCI are simultaneously processed by utilizing the same detected optical signals. The comparison was carried out by imaging a rotating diffuser. LDI has a linear response to the velocity. In contrast, LSCI is exposure time dependent and does not provide a linear response in the presence of static speckle. It is also demonstrated that the relationship between LDI and LSCI can be related through a power law which depends on the exposure time of LSCI. 相似文献
5.
Tomm B. Müller Richard A. Jones Olav Haraldseth Jørgen Westby Geirmund Unsgård 《Magnetic resonance imaging》1996,14(10):1177-1183
The purpose of this investigation was to correlate magnetic resonance (MR) perfusion measurements with absolute regional cerebral blood flow (rCBF) in a rat model of focal ischemia. The MR perfusion measurements were made using dynamic first-pass bolus tracking of a susceptibility contrast agent, whereas rCBF was measured using radioactive microspheres. Two simple MR perfusion parameters, the maximum change in
(
) and time delay to
(
), were derived from the signal intensity versus time curves on a pixel-to-pixel basis, without applying curve-fitting procedures or tracer kinetic theory. In each hemisphere,
and
were compared with the rCBF measurements in four selected regions of interest. Sixteen MR bolus tracking series were performed in 12 rats with occlusion of the middle cerebral artery. In all of the individual series there was a significant correlation (.0001 ≤ p ≤ .02) between
and the microsphere rCBF measurements, with correlation coefficients ranging from .784 to .983. Pooling the
data resulted in a correlation coefficient of .809 (p = .0001). There was a nonlinear correlation between the
and rCBF. For both parameters there was considerable variation between different measurements regarding both the slope of the regression line and its intercept with the y-axis. Our results justify the use of
as a relative measure of perfusion during acute cerebral ischemia. Because of the interindividual variation, calibration of MR perfusion measurements for the estimation of absolute flow values must be considered unreliable. The
may have physiological relevance as a marker of collateral flow. 相似文献