首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 53 毫秒
1.
The selective enrichment of specific proteins or peptides on micropipette tips prior to mass spectrometry analysis, which can minimize non-specific interferences as well as sample loss, has been an important issue in current proteomics field. In this paper, we have developed an easy-to-use phosphopeptide-selective pipette tip in which titanium dioxide nanoparticles were embedded in monolithic structure photopolymerized from ethylene glycol dimethacrylate. The simple and convenient fabrication was feasible in a commercial polypropylene pipette tip. Phosphorylated peptides were isolated from non-phosphopeptides by TiO(2) nanoparticle and eluted by 100 mM ammonium phosphate (pH 8.5), which was compatible with 2,5-dihydroxybenzoic acid (DHB)/1% phosphoric acid matrix and allowed for direct analysis of the elution fraction by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) without the necessity of desalting pretreatment. Tryptic digested alpha-casein and beta-casein spiked into bovine serum albumin (BSA) nonphosphorylated peptides (molar ratio 1:1:10) were used to assess the selectivity of TiO(2) tips. The effect of 50 mM ammonium hydrogencarbonate, pH 8 in 50% acetonitrile used as a wash buffer in reduction of nonspecific bound peptide to TiO(2) tip was dramatic. Almost all non-phosphopeptides were not detected by MALDI-MS analysis. The lowest detectable amount of phosphopeptide was estimated at low femtomole level. The easy-to-use TiO(2)-embeded tips operated in combination with the modified wash and elution conditions enable an efficient phosphopeptide enrichment for mass spectrometric analysis.  相似文献   

2.
While surfactants are commonly used in preparing protein samples, their presence in a protein sample can potentially affect the enzymatic digestion process and the subsequent analysis of the resulting peptides by mass spectrometry. The extent of the tolerance of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) to surfactant interference in peptide analysis is very much dependent on the matrix/sample preparation method. In this work the effects of four commonly used surfactants, namely n-octyl glucoside (OG), Triton X-100 (TX-100), 3-[(3-cholamidopropyl)dimethylammonio]-1-propanesulfonate (CHAPS) and sodium dodecyl sulfate (SDS), for biological sample preparation on trypsin digestion and MALDI-MS of the resulting digest are examined in detail within the context of using a two-layer method for MALDI matrix/sample preparation. Non-ionic and mild surfactants, such as OG, TX-100 or CHAPS, are found to have no significant effect on trypsin digestion with surfactant concentrations up to 1%. However, TX-100 and CHAPS interfere with the subsequent peptide analysis by MALDI-MS and should be removed prior to peptide analysis. OG is an MS-friendly surfactant and no effect is observed for MALDI peptide analysis. The effect of SDS on trypsin digestion in terms of the number of peptides generated and the overall protein sequence coverage by these peptides is found to be protein dependent. The use of SDS to solubilize hydrophobic membrane proteins, followed by trypsin digestion in the presence of 0.1% SDS, results in a peptide mixture that can be analyzed directly by MALDI-MS. These peptides are shown to provide better sequence coverage compared with those obtained without the use of SDS in the case of bacteriorhodopsin, a very hydrophobic transmembrane protein. This work illustrates that MALDI-MS with the two-layer sample preparation method can be used for direct analysis of protein digests with no or minimum sample cleanup after proteins are digested in a solution containing surfactants.  相似文献   

3.
Analysis of tryptic digests of proteins using matrix-assisted laser desorption/ionization (MALDI) mass spectrometry commonly results in superior detection of arginine-containing peptides compared with lysine-containing counterparts. The effect is attributable in part to the greater stability of the arginine-containing peptide ions associated with the sequestration of the single ionizing proton on the arginine side-chain. Reaction of peptides with O-methylisourea resulted in conversion of lysine to homoarginine residues with consequent improved detection during MALDI-MS. Analysis of the underivatized tryptic digest of the yeast protein, enolase, revealed peptides representing 20% of the protein; the corresponding figure after derivatization was 46%.  相似文献   

4.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) analysis of complex peptide mixtures is often hampered by signal suppression effects as well as certain intrinsic properties of specific peptides that influence the desorption/ionization behavior. The present systematic study reports on the relationship between the occurrence of certain amino acids in peptides and the intensities of the related ions which appear during MALDI-MS analysis for both tryptic digests of proteins and synthetic peptide mixtures. The analysis of the tryptic digests revealed that the peptide sequences of the most intense peaks detected by MALDI-MS contained significantly higher proportions of arginine, phenylalanine, proline, and leucine than the average values for the measured proteins. The relationship between the relative signal intensities and amino acid compositions of peptides was studied in more detail by the partial least squares (PLS) method using equimolar mixtures of 144 well-characterized synthetic peptides. The regression coefficients clearly indicated that the presence of arginine, phenylalanine, leucine and proline tend to enhance the desorption/ionization process which results in higher MALDI-MS peak intensities. Furthermore, it was shown that the impact of arginine depends strongly on the identity of adjacent amino acids.  相似文献   

5.
Protocols for the analysis of the sulfhydryl content in peptides and proteins using chemical derivatization by organomercurial reagents and analysis by matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) have been developed. The number of reactive cysteine residues in peptides and proteins can be determined by exploiting the affinity and selectivity of organomercurial reagents for macromolecular thiols. Mass shifts observed in MALDI mass spectra obtained before and after cysteine derivatization with p-hydroxy-mercuribenzoate (pHMB) permit the number of free sulfhydryl groups to be determined. The pHMB derivative of each free cysteine residue provides a mass shift of 321 u, overcoming limitations in the mass resolution of MALDI time-of-flight mass spectrometry. Reactive cysteine residues in a macromolecule can be selectively derivatized by using a fivefold molar excess of pHMB reagent. Total sulfhydryl content (i.e., cysteine and cystine) can be determined after disulfide reduction. However, analyses for total cysteine content are more complex, requiring protein denaturation, cystine reduction, and sample purification before derivatization and analysis by MALDI-MS. Conditions for sample denaturation, alkyl-phosphine reduction, pHMB derivatization, and sample purification by analyte adsorption and desalting on protein transfer membranes, are described for cysteine/cystine analysis performed on microgram (10–200 pmol) quantities of somatostatin, insulin, hemoglobin, and β-lactoglobulin.  相似文献   

6.
Sample preparation still remains a great challenge in modern bioanalysis and the interest in new efficient solid phase extraction (SPE) materials still remains high. In this work, hexagonal boron nitride (h-BN) is introduced as a new SPE material for the isolation and enrichment of peptides. The h-BN is isoelectronic and structurally similar to graphite. It has remarkable properties including good thermal conductivity, excellent thermal and chemical stability and a better oxidation resistance than graphite. BN attracts increasing interest because of its wide range of applicability. In the present work, the great potential of h-BN, as a new SPE-material, on the enrichment, preconcentration and desalting of tryptic digest of model proteins is demonstrated. A special attention was dedicated to the efficient enrichment of hydrophilic phosphopeptides. Two elution protocols were developed for the enrichment of peptides compatible for subsequent MALDI-MS and ESI-MS analysis. In addition, the recoveries of 5 peptides and 3 phosphopeptides with wide range of pI values utilizing h-BN materials with different surface areas were investigated. 84–106% recovery rate could be achieved using h-BN materials. The results were compared with those obtained using graphite and silica C18 under the same elution conditions, and lower recoveries were obtained. In addition, h-BN was found to have a capability of protein depletion, which is requisite for the peptide profiling.  相似文献   

7.
We have applied an arginine-specific labeling technique to the study of peptides by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The reaction converts the guanidine group of the arginine side chain by reacting it with 2,3-butanedione and an arylboronic acid. Despite the general chemical lability of the tag under acidic conditions, it was possible to employ acidic matrices like alpha-cyano-4-hydroxycinnamic acid without adverse effects, using the thin-layer technique for preparation. After optimizing the method using arginine-containing model peptides--for which sensitivity down to the low fmol range was demonstrated--the procedure was applied to enzymatic digests of several model proteins in solution and to protein spots in gels obtained by two-dimensional electrophoretic separation of cell lysate samples. Information on the presence of arginine in peptides can be easily obtained from the mass spectra by the characteristic mass shift and the isotope pattern resulting from the incorporation of boron. This information might serve as a valuable additional search constraint for achieving a higher degree of confidence for protein identification by peptide mass fingerprinting.  相似文献   

8.
Tryptic peptides were labeled with sulfonic acid groups at the N-termini using an improved chemistry. The derivatization was performed in common aqueous buffers on peptides adsorbed onto a ZipTip trade mark C(18), thus allowing simultaneous desalting/concentration of the sample. When only Arg-terminating peptides were considered, the procedure from adsorption onto the ZipTip until analysis by MALDI-PSD took about 10 min and several samples could be worked on in parallel. The resulting improved post-source decay (PSD) fragmentation produced spectra containing only y-ions. PSD amino acid sequencing of underivatized and derivatized synthetic peptides was compared. From the sequence information obtained from derivatized peptides isolated by ion selection from tryptic in-gel digests, a protein was correctly identified which was difficult to analyze from an unclear peptide mass fingerprint analysis. The method was also applied to the identification and localization of phosphorylated Ser and Tyr residues in native and synthetic peptides.  相似文献   

9.
Finehout EJ  Lee KH 《Electrophoresis》2003,24(19-20):3508-3516
A comparison of automated in-gel digestion methods for low picomolar to femtomolar levels of protein is presented. Gel spots with 4 pmol to 120 fmol of protein were stained with either Coomassie colloidal blue or SYPRO Ruby and digested using an automated platform. The sequence coverages and average peak intensities obtained from a matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) analysis are compared. Results show that methods using an acetonitrile extraction or digest times greater than the standard 4 h give no significant increase in peptide sequence coverage for automated digestion of low protein level samples. It is also shown that digests from SYPRO Ruby-stained gels show a greater improvement upon ZipTip cleanup than digests from Coomassie colloidal blue-stained gels. The digests from SYPRO Ruby-stained gels are also shown to give a higher average peptide intensity if a method with minimal gel plug washing is used.  相似文献   

10.
Shiau KJ  Hung SU  Lee HW  Wu CC 《The Analyst》2011,136(9):1922-1927
Simultaneous detection of multiply and singly phosphorylated peptides using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is challenging because of suppression effects during ionization. In oder to overcome this problem, this study presents a new approach to improve the detection of phosphopeptides by stepwise enrichment using polyarginine-coated (PA-coated) and titanium dioxide-coated (TiO(2)-coated) nanodiamonds for fractionation of multiply and singly phosphorylated peptides prior to on-probe MALDI MS analysis. The feasibility of this approach was demonstrated using synthetic peptides containing different numbers of phosphate groups, tryptic digests of α-casein, β-casein, and complex protein mixtures. The high specificity of the approach is shown in its effective enrichment and fractionation of phosphopeptides from the digest of β-casein and bovine serum albumin at a molar ratio as low as 1 : 1000, which out-performs the commercial Fe(3+)-IMAC and TiO(2) isolation kits. It offers a simple and effective alternative for the fractionation and identification of multiply and singly phosphorylated peptides by MALDI MS and allows for deduction of more information from limited starting materials.  相似文献   

11.
米薇  王晶  应万涛  贾伟  蔡耘  钱小红 《色谱》2010,28(2):108-114
多维色谱分离、串联质谱分析技术已在蛋白质组研究中得到广泛应用。然而生物样品的蛋白质以及全酶切肽段具有高度的复杂性,这严重干扰了蛋白质高通量、规模化的分析。通过标签肽段富集进行样品预分离可以降低体系的复杂程度。本文建立了一种基于共价色谱技术选择性分离富集含半胱氨酸肽的方法,从而降低了样品体系的复杂程度。首先以牛血清白蛋白(BSA)的酶切肽段为模型,对富集条件进行了优化和考察,并在此基础上通过5种蛋白质酶切肽段混合物的富集对该方法进行了验证。结果证明此方法的重现性好,富集效率高,富集特异性好,能有效地富集鉴定含半胱氨酸肽段。所建立的方法在复杂体系的蛋白质组研究中具有广泛的应用前景,为复杂样品的蛋白质高通量、自动化、规模化鉴定和定量研究提供了实用技术。  相似文献   

12.
High-throughput proteomics has typically relied on protein identification based on MALDI-MS peptide maps of proteolytic digests of 2D-gel-separated proteins. This technique, however, requires significant sequence coverage in order to achieve a high level of confidence in the identification. Tandem MS data have the advantage of requiring fewer peptides (2) for high confidence identification, assuming adequate MS/MS sequence coverage. MALDI-MS/MS techniques are becoming available, but can still be problematic because of the difficulty of inducing fragment ions of a singly charged parent ion. Electrospray ionization, however, has the advantage of generating multiply charged species that are more readily fragmented during MS/MS analysis. Two electrospray/tandem mass spectrometry-based approaches, nanovial-ESI-MS/MS and LC-MS/MS, are used for high throughput proteomics, but much less often than MALDI-MS and peptide mass fingerprinting. Nanovial introduction entails extensive manual manipulation and often shows significant chemical background from the in-gel digest. LC-MS has the advantages that the chemical background can be removed prior to analysis and the analytes are concentrated during the separation, resulting in more abundant analyte signals. On the other hand, LC-MS can often be time intensive. Here, we report the incorporation of on-line sample clean-up and analyte concentration with a high-throughput, chip-based, robotic nano-ESI-MS platform for proteomics studies.  相似文献   

13.
Reverse-micelle forming amphiphilic homopolymers with carboxylic acid and quaternary amine substituents are used to selectively enrich biomarker peptides and protein fragments from human serum prior to matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) analysis. After depletion of human serum albumin (HSA) and immunoglobulin G (IgG), low abundance peptide biomarkers can be selectively enriched and detected by MALDI-MS at clinically relevant concentrations by using the appropriate homopolymer(s) and extraction pH value(s). Three breast cancer peptide biomarkers, bradykinin, C4a, and ITIH(4), were chosen to test this new approach, and detection limits of 0.5 ng mL(-1), 0.08 ng mL(-1), and 0.2 ng mL(-1), respectively, were obtained. In addition, the amphiphilic homopolymers were used to detect prostate specific antigen (PSA) at concentrations as low as 0.5 ng mL(-1) by targeting a surrogate peptide fragment of this protein biomarker. Selective enrichment and sensitive MS detection of low abundance peptide/protein biomarkers by these polymeric reverse micelles should be a sensitive and straightforward approach for biomarker screening in human serum.  相似文献   

14.
A mass spectrometric study has been carried out to elucidate the structures of glycated peptides obtained after in vitro gastrointestinal digestion of bovine beta-lactoglobulin (beta-LG) glycated with prebiotic galacto-oligosaccharides (GOS). The digests of both native and glycated beta-LG were analyzed by MALDI-MS, LC-ESI-MS, and LC-ESI-MS/MS. MALDI-MS profiles showed marked differences mainly related to the lower intensity of ions corresponding to the digest of glycated beta-LG. Overall, 58 and 23 unglycated peptides covering 97% and 63% of the mature beta-LG sequence could be identified in the digests of native and glycated samples, respectively. The LC-ESI-MS analyses corroborated the MALDI-MS results regarding the unglycated peptides but they also enabled an extensive investigation into the digest of glycated beta-LG. Thus, a total of 19 peptides glycated with GOS from two to seven hexose units could be identified. The tandem mass spectra of glycated peptides were mostly characterized by two neutral losses of 1026/1056, 864/894, 702/732, 540/570, 378/408, and 216/246 u, corresponding to the formation of the furylium ion and its subsequent "CHOH" loss, indicative of the peptide glycation with hepta-, hexa-, penta-, tetra-, tri-, and disaccharides, respectively. Also, other minor ionic species containing the furylium ring linked to different galactose units could be also detected, showing the diversity of the fragmentation pattern of peptides glycated with larger size carbohydrates. Finally, the putative GOS glycation sites could be determined at the NH(2)-terminal Leu residue and at Lys residues located in positions 14, 47, 75, 77, 83, 91, 100, 135, and 138.  相似文献   

15.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a powerful tool for the analysis and characterization of protein phosphorylation on the peptide level. In this study, the applicability of ionic liquid matrices (ILM) formed by combination of the crystalline MALDI matrix 2,5-dihydroxybenzoic acid (DHB) with pyridine or n-butylamine was tested for the analysis of phosphopeptides. Low ionization efficiency in both positive and negative ion mode was observed in acid-free sample preparations. Upon addition of 0.1% trifluoroacetic acid (TFA), ion formation was increased, but analogously to the situation described earlier for pure DHB, best results were obtained upon use of 1% phosphoric acid as matrix additive. The samples prepared in this way were significantly more homogeneous than preparations with pure DHB, thus avoiding the need for time-consuming search for hot spots. Other characteristics like metastable fragmentation of phosphopeptides did not differ from that observed in classical preparations. The limits of detection for synthetic phosphopeptides and singly or multiply phosphorylated peptides from tryptic digests of alpha- and beta-casein were comparable with those obtained when using pure DHB; in some cases even higher signal intensities could be observed in the ILM. The use of ILM in combination with 1% phosphoric acid as matrix additive significantly facilitates analysis of phosphopeptides by MALDI-MS.  相似文献   

16.
A method has been developed for rapid and sensitive identification of epitope-containing peptides, based on direct MALDI-MS/MS analysis of epitope-containing peptides affinity bound to affinity beads. This technique provides sequence information of the epitope that allows unambiguous identification of the epitope either by database searching or de novo sequencing. With MALDI-MS, affinity beads with bound peptides can be placed directly on the MALDI target and analyzed. Coupling a MALDI source to an orthogonal injection quadrupole time-of-flight (QqTOF) mass spectrometer allows direct sequencing of the bound peptides. In contrast to ESI-MS/MS, elution of the affinity-bound peptides followed by additional concentration and purification steps is not required, thus reducing the potential for sample loss. Direct mass spectrometric sequencing of affinity-bound peptides eliminates the need for chemical or enzymatic sequencing. Other advantages of this direct MALDI-MS/MS analysis of epitope-containing peptides bound to the affinity beads include its sensitivity (femtomole levels) and speed. In addition, direct analysis of peptides on affinity beads does not adversely affect the high mass accuracy of a QqTOF, and database searching can be performed on the MS/MS spectra obtained. In proof-of-principle experiments, this method has been demonstrated on beads containing immobilized antibodies against phosphotyrosine, the c-myc epitope tag, as well as immobilized avidin. Furthermore, de novo sequencing of epitope-containing peptides is demonstrated. The first application of this method was with anti-FLAG-tag affinity beads, where direct MALDI MS/MS was used to determine an unexpected enzymatic cleavage site on a growth factor protein.  相似文献   

17.
The present report describes the design and application of a dual sprayer system for high-throughput proteome analysis. This system comprises parallel solid-phase extraction cartridges used for preconcentration and desalting of proteolytic digests prior to nanoelectrospray mass spectrometry analyses. Tryptic peptides from in-gel digest of protein bands/spots are first adsorbed on styrene divinyl benzene membrane and subsequently eluted with a short plug of organic buffer prior to infusion to the mass spectrometer at a flow rate of typically 500 nL/min. Tryptic peptide eluting from the membrane are analyzed by the mass spectrometer by moving in turn each sprayer in front of the sampling orifice. Sequential injection, preconcentration and analyses of tryptic digests are typically achieved with a throughput of up to 3.5 min/sample and a detection limit of approximately 8-80 fmol per injection. Replicate injections of peptide mixtures indicated that reproducibility of peak areas ranged from relative standard deviations (RSD) of 1.1% to 4.5%. The application of this device is demonstrated for digests of gel-isolated proteins obtained from sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) separation of rat liver plasma membrane and from two-dimensional gel electrophoresis of total cell lysate extracts from human prostatic cancer cell.  相似文献   

18.
To improve the detection of phosphorylated peptides/proteins, a combination of optimized MS-based strategies were used involving chemical derivatization with a polyhistidine-tag (His-tag) and affinity enrichment of the resulting His-tag peptides on a nanoscale Ni(2+)-IMAC column. The phosphoserine and phosphothreonine peptides were derivatized using a one-pot beta-elimination/Michael addition reaction with a reversible His-tag possessing a thiol-containing Cys residue. The His-tag peptides were enriched selectively by Ni(2+)-IMAC and released using either imidazole or cleavage with Factor Xa. This novel capture and enzyme-mediated release provided an additional element of selectivity and yielded phosphopeptide-specific modifications with enhanced MS ionization characteristics. The eluted peptides were mapped using MALDI-TOF MS and QTRAP ESI-MS/MS techniques. The results obtained for a model peptide and two tryptic protein digests show that the method is highly specific and allows selective enrichment of phosphorylated peptides at low concentrations of femtomoles per microliter.  相似文献   

19.
A new mass spectrometry based analysis strategy has been established here for high-molecular-weight (HMW) proteome research. First, a 2-hydroxyethyl agarose/polyacrylamide (HEAG/PAM) electrophoresis gel was designed for the first time to realize an easy-handling separation method with high spatial resolution for HMW proteins, good reproducibility and mass spectrometry-compatible sliver staining. Second, ZnO-polymethyl methacrylate (ZnO-PMMA) nanobeads were applied here for enriching and desalting the peptides from the HMW proteins. Third, the peptides were analyzed by matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) with the presence of the ZnO-PMMA nanobeads, and their MS signals were enhanced markedly. The success rate of identification for HMW proteins was significantly increased due to high enriching efficiency and salt tolerance capability as well as signal enhancing capability of the ZnO-PMMA nanobeads. We believe that this analysis strategy will inspire and accelerate the HMW proteome studies.  相似文献   

20.
Multiple reaction monitoring (MRM) is commonly used for the quantitative analysis of proteins during mass pectrometry (MS), and has excellent specificity and sensitivity for an analyte in a complex sample. In this study, a pseudo-MRM method for the quantitative analysis of low-abundance serological proteins was developed using hybrid quadrupole time-of-flight (hybrid Q-TOF) MS and peptide affinity-based enrichment. First, a pseudo-MRM-based analysis using hybrid Q-TOF MS was performed for synthetic peptides selected as targets and spiked into tryptic digests of human serum. By integrating multiple transition signals corresponding to fragment ions in the full scan MS/MS spectrum of a precursor ion of the target peptide, a pseudo-MRM MS analysis of the target peptide showed an increased signal-to-noise (S/N) ratio and sensitivity, as well as an improved reproducibility. The pseudo-MRM method was then used for the quantitative analysis of the tryptic peptides of two low-abundance serological proteins, tissue inhibitor of metalloproteinase 1 (TIMP1) and tissue-type protein tyrosine phosphatase kappa (PTPκ), which were prepared with peptide affinity-based enrichment from human serum. Finally, this method was used to detect femtomolar amounts of target peptides derived from TIMP1 and PTPκ, with good coefficients of variation (CV 2.7% and 9.8%, respectively), using a few microliters of human serum from colorectal cancer patients. The results suggest that pseudo-MRM using hybrid Q-TOF MS, combined with peptide affinity-based enrichment, could become a promising alternative for the quantitative analysis of low-abundance target proteins of interest in complex serum samples that avoids protein depletion.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号