首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
ZnS-polyacrylic acid (ZnS-PAA) was prepared by an in situ polymerization method using nano-ZnS as core in the presence of acrylic acid (AA), and ZnS-PAA nanoparticles was characterized by ultraviolet spectrometry (UV) and transmission electron microscopy (TEM). Based on the significant increase of the resonance light scattering (RLS) intensity with the interaction between nanoparticles and serum albumin, RLS method was developed for the sensitive determination of serum albumin (BSA and HSA). Under optimum conditions, the change of the intensity (ΔI) of the RLS spectra at λ = 392 nm was linearly proportional to the concentration of BSA and HSA. The linear range was 1–100 ng mL?1 for HSA and 1–120 ng mL?1 for BSA, and the limit of detection (LOD) was 0.4 ng mL?1 for HSA and 0.5 ng mL?1 for BSA. This method proved to be very sensitive, rapid, simple and tolerant of most interfering substances.  相似文献   

2.
An ultra-preconcentration technique composed of solid-phase extraction (SPE) and dispersive liquid–liquid microextraction (DLLME) coupled with gas chromatography–flame photometric detection (GC–FPD) was used for determination of thirteen organophosphorus pesticides (OPPs) including phorate, diazinon, disolfotane, methyl parathion, sumithion, chlorpyrifos, malathion, fenthion, profenphose, ethion, phosalone, azinphose-methyl and co-ral in aqueous samples. The analytes were collected from large volumes of aqueous solutions (100 mL) into 100 mg of a SPE C18 sorbent. The effective variables of SPE including type and volume of elution solvent, volume and flow rate of sample solution, and salt concentration were investigated and optimized. Acetone was selected as eluent in SPE and disperser solvent in DLLME and chlorobenzene was used as extraction solvent. Under the optimal conditions, the enrichment factors were between 15,160 and 21,000 and extraction recoveries were 75.8–105.0%. The linear range was 1–10,000 ng L?1 and limits of detection (LODs) were between 0.2 and 1.5 ng L?1. The relative standard deviations (RSDs) for 50 ng L?1 of OPPs in water with and without an internal standard, were in the range of 1.4–7.9% (n = 5) and 4.0–11.6%, respectively. The relative recoveries of OPPs from well and farm water sat spiking levels of 25 and 250 ng L?1 were 88–109%.  相似文献   

3.
In this work, the potential of modified multiwalled carbon nanotubes for separation and preconcentration of trace amounts of manganese ion is studied. Multiwalled carbon nanotubes were oxidized with concentrated HNO3 and then modified with loading 1-(2-pyridylazo)-2-naphtol. Mn(II) ions could be quantitatively retained by modified multiwalled carbon nanotubes in the pH range of 8–9.5. Elution of the adsorbed manganese was carried out with 5.0 mL of 0.1 mol L?1 HNO3. Detection limit is 0.058 ng mL?1 and analytical curve is linear in the range of 0.1 ng mL?1–5.0 μg mL?1 in the initial solution with a correlation coefficient 0.9977 and the preconcentration factor is 100. Relative standard deviation for eight replicate determination of 0.5 μg mL?1 of manganese in the final solution is 0.41%. The effects of the experimental parameters, including the sample pH, flow rates of sample and eluent solution, eluent type, breakthrough volume and interference ions, were studied for preconcentration of Mn(II) ions in detail to optimize the conditions. The method was successfully applied for separation, preconcentration and determination of manganese in different samples.  相似文献   

4.
A sensitive and selective liquid chromatographic–tandem mass spectrometric (LC–MS–MS) method was developed to determine pantoprazole sodium (PNT) in human urine. After solid-phase extraction with SPE cartridge, the urine sample was analysed on a C18 column (symmetry 3.5 μm; 75 mm × 4.6 mm i.d) interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of acetonitrile–water (90:10, v/v). The method was linear over a concentration range of 1–100 ng mL?1. The lower limit of quantitation was 1 ng mL?1. The intra-day and inter-day relative standard deviation across three validation runs over the entire concentration range was <10.5%. The accuracy determined at three concentrations (8.0, 50.0 and 85.0 ng mL?1 PNT) was within ±1.25% in terms of relative errors.  相似文献   

5.
A disposable sensor for the determination of cotinine in human serum was developed based on immunochromatographic test strip and quantum dot label. In this assay, cotinine linked with quantum dot competes with cotinine in sample to bind to anti-cotinine antibody in the test strip and the quantum dots serve as signal vehicles for electrochemical readout. Some parameters governing the performance of the sensor were optimized. The sensor shows a wide linear range from 1 ng mL?1 to 100 ng mL?1 cotinine with a detection limit of 1.0 ng mL?1. The sensor was validated with spiked human serum samples and it was found that this method was reliable in measuring cotinine in human serum. The results demonstrate that this sensor is rapid, accurate, and less expensive and has the potential for point of care (POC) detection of cotinine and fast screening of tobacco smoke exposure.  相似文献   

6.
A simple and rapid technique based on salting out assisted solvent extraction was developed for extraction of atorvastatin from serum sample and high performance liquid chromatography–UV was used for its detection. In the present study, 1.0 mL serum was extracted by 0.5 mL of acetonitrile and some parameters that can affect extraction such as type and volume of extraction solvent, type of salt, and pH were optimized. Under optimized experimental conditions, the calibration curve was found to be linear in the range of 0.001–10 ng mL−1 in human serum and the correlation coefficient (R2) and the limits of detection were >0.99 and 0.0005 ng mL−1, respectively. The accuracy of the method in terms of average recovery of the compound in spiked serum and water samples was better than 90%.  相似文献   

7.
This paper presents a novel approach to electrochemically determine enzymatically active PSA using ferrocene-functionalized helix peptide (CHSSLKQK). The principle of electrochemical measurement is based on the specific proteolytic cleavage events of the FC-peptide on the gold electrode surface in the presence of PSA, resulting the change of the current signal of the electrode. The percentage of the decreased current is linear with the concentration of active PSA at the range of 0.5–40 ng mL?1 with a detection limit of 0.2 ng mL?1. The direct transduction of peptide cleavage events into an electrical signal provides a simple, sensitive method for detecting the enzymatic activity of PSA and determining the active PSA concentration.  相似文献   

8.
In this study, dispersive liquid–liquid microextraction (DLLME) combined with ultra-high-pressure liquid chromatography (UHPLC)–tunable ultraviolet detection (TUV), has been developed for pre-concentration and determination of triclosan (TCS), triclocarban (TCC) and methyl-triclosan (M-TCS) in aqueous samples. The key factors, including the kind and volume of extraction solvent and dispersive solvent, extraction time, salt effect and pH, which probably affect the extraction efficiencies were examined and optimized. Under the optimum conditions, linearity of the method was observed in the range of 0.0500–100 μg L?1 for TCS, 0.0250–50.0 μg L?1 for TCC, and 0.500–100 μg L?1 for M-TCS, respectively, with correlation coefficients (r2) > 0.9945. The limits of detection (LODs) ranged from 45.1 to 236 ng L?1. TCS in domestic waters was detected with the concentration of 2.08 μg L?1. The spiked recoveries of three target compounds in river water, irrigating water, reclaimed water and domestic water samples were achieved in the range of 96.4–121%, 64.3–84.9%, 77.2–115% and 75.5–106%, respectively. As a result, this method can be successfully applied for the rapid and convenient determination of TCS, TCC and M-TCS in real water samples.  相似文献   

9.
The originality on the high efficiency of murexide modified halloysite nanotubes as a new adsorbent of solid phase extraction has been reported to preconcentrate and separate Pd(II) in solution samples. The new adsorbent was confirmed by Fourier transformed infrared spectra, X-ray diffraction, scanning electron microscope, transmission electron microscope and N2 adsorption–desorption isotherms. Effective preconcentration conditions of analyte were examined using column procedures prior to detection by inductively coupled plasma-optical emission spectrometry (ICP-OES). The effects of pH, the amount of adsorbent, the sample flow rate and volume, the elution condition and the interfering ions were optimized in detail. Under the optimized conditions, Pd(II) could be retained on the column at pH 1.0 and quantitatively eluted by 2.5 mL of 0.01 mol L?1 HCl–3% thiourea solution at a flow rate of 2.0 mL min?1. The analysis time was 5 min. An enrichment factor of 120 was accomplished. Common interfering ions did not interfere in both separation and determination. The maximum adsorption capacity of the adsorbent at optimum conditions was found to be 42.86 mg g?1 for Pd(II).The detection limit (3σ) of the method was 0.29 ng mL?1, and the relative standard deviation (RSD) was 3.1% (n = 11). The method was validated using certified reference material, and has been applied for the determination of trace Pd(II) in actual samples with satisfactory results.  相似文献   

10.
In the present study, a simple and sensitive extraction method based on polypropylene membrane-protected micro-solid phase extraction (MP-μ-SPE) has been developed for analysis of sulfonamides in food samples. Poly (methacrylic acid-ethylene glycol dimethacrylate) (p-MAA-EDMA) was synthesized using orthogonal array experimental design, optimized with three factors at four levels and evaluated on yield, hydrophobic and cation-exchange properties. The optimized p-MAA-EDMA was then employed as the sorbent in the MP-μ-SPE for extraction of sulfonamides from milk and chicken muscle samples, followed by high performance liquid chromatographic analysis with ultraviolet detection. Under optimized extraction conditions, good linearities (0.010–1.0 μg mL?1 with r2 > 0.9900), low limits of detection (0.38–0.62 ng mL?1), and acceptable intra-day (2.7–13.7%) and inter-day (6.7–15.2%) relative standard deviations were obtained. It was demonstrated to be an effective approach to handle semi-solid/solid samples with good resistance to interference from “dirty” samples.  相似文献   

11.
Titanium dioxide (i.e. TiO2) in nano-form is a constituent of many nanomaterials that are used in sunscreens, cosmetics, industrial products and in biomedical applications. Quantification of TiO2 nanoparticles in various matrixes is a topic of great interest for researchers studying the potential health and environmental impacts of nanoparticles. However, analysis of TiO2 as Ti4+ is difficult because current digestion techniques require use of strong acids that may be a health and safety risk in the laboratory. To overcome this problem, we developed a new method to digest TiO2 nanoparticles using ammonium persulfate as a fusing reagent. The digestion technique requires short times to completion and optimally requires only 1 g of fusing reagent. The fusion method showed >95% recovery of Ti4+ from 6 μg mL?1 aqueous suspensions prepared from 10 μg mL?1 suspension of different forms of TiO2, including anatase, rutile and mixed nanosized crystals, and amorphous particles. These recoveries were greater than open hot-plate digestion with a tri-acid solution and comparable to microwave digestion with a tri-acid solution. Cations and anions commonly found in natural waters showed no significant interferences when added to samples in amounts of 10 ng to 110 mg, which is a much broader range of these ions than expected in environmental samples. Using ICP-MS for analysis, the method detection limit (MDL) was determined to be 0.06 ng mL?1, and the limit of quantification (LOQ) was 0.20 ng mL?1. Analysis of samples of untreated and treated wastewater and biosolids collected from wastewater treatment plants yielded concentrations of TiO2 of 1.8 and 1.6 ng mL?1 for the wastewater samples, respectively, and 317.4 ng mg?1 dry weights for the biosolids. The reactions between persulfate ions and TiO2 were evaluated using stoichiometric methods and FTIR and XRD analysis. A formula for the fusing reaction is proposed that involves the formation of sulfate radicals.  相似文献   

12.
A cloud point extraction process using mixed micelle of the anionic surfactant sodium dodecyl sulfate (SDS) and the non-ionic surfactant polyoxyethylene(7.5)nonylphenylether (PONPE 7.5) to extract two fluoroquinolone antimicrobial agents, ofloxacin and gatifloxacin, from aqueous media was investigated. The method is based on the mixed micelle-mediated extraction of fluoroquinolones in the presence of NaCl as an inducing agent in phase separation, followed by spectrofluorimetric determination. The effect of different variables such as pH, PONPE7.5 concentration, SDS concentration, NaCl concentration, cloud point temperature, and time was investigated, and optimum conditions were established. At optimum conditions, the rectilinear calibration graphs were obtained in the concentration range of 0.1–150 and 0.1–250 ng mL?1 for ofloxacin and gatifloxacin, and the limits of detection were 0.04 and 0.06 ng mL?1, respectively. The proposed procedure was applied successfully for the detection of the investigated drugs in their pharmaceutical dosage forms, in spiked plasma, spiked urine, and urine samples, with good precision and accuracy.  相似文献   

13.
《Microchemical Journal》2011,97(2):277-282
UV photochemical vapor generation (photo-CVG) as sample introduction was first adapted for determination of ultratrace cobalt by atomic fluorescence spectrometry (AFS). Cobalt volatile species can be generated when the buffer system of formic acid and formate containing Co (II) is exposed to UV radiation. The generated gaseous products were separated from liquid phase within a gas–liquid separator and then transported to AFS for determination of cobalt. Factors affecting the efficiency of photo-CVG were investigated in detail, including type and concentration of low molecular weight (LMW) organic acid, buffer system, UV irradiation time, reaction temperature, carrier gas flow rate and hydrogen flow rate. With 4% (v/v) HCOOH and 0.4 mol L 1 HCOONa buffer solution, 150 s irradiation time and 15 W low pressure mercury lamp, a generation efficiency of 23–25% was achieved. A limit of detection (LOD) of 0.08 ng mL 1 without any pre-concentration procedure and a precision of 2.2% (RSD, n = 11) at 20 ng mL 1 were obtained under the optimized conditions. The proposed method was successfully applied in the analysis of several simple matrix real water samples.  相似文献   

14.
A new approach to performing extraction and preconcentration employing functionalized magnetic nanoparticles for the determination of trace metals is presented. Alumina-coated iron oxide nanoparticles were synthesized and used as the solid support. The nanoparticles were functionalized with sodium dodecyl sulfate and used as adsorbents for solid phase extraction of the analyte. Extraction, elution, and detection procedures were performed sequentially in the sequential injection lab-on-valve (SI-LOV) system followed by electrothermal atomic absorption spectrometry (ETAAS). Mixtures of hydrophobic analytes were successfully extracted from solution using the synthesized magnetic adsorbents. The potential use of the established scheme was demonstrated by taking cobalt as a model analyte. Under the optimal conditions, the calibration curve showed an excellent linearity in the concentration range of 0.01–5 μg L?1, and the relative standard deviation was 2.8% at the 0.5 μg L?1 level (n = 11). The limit of detection was 6 ng L?1 with a sampling frequency of 18 h?1. The present method has been successfully applied to cobalt determination in water samples and two certified reference materials.  相似文献   

15.
A method for preconcentration of palladium at trace level on modified multiwalled carbon nanotubes columns and determination by flame atomic absorption spectrometry (FAAS) has been developed. Multiwalled carbon nanotubes (MWCNTs) were oxidized with concentrated HNO3 and the oxidized multiwalled carbon nanotubes were modified with 5-(4′-dimethylamino benzyliden)-rhodanine, and then were used as a solid sorbent for preconcentration of Pd(II) ions. Factors influencing sorption and desorption of Pd(II) ions were investigated. The sorption of Pd(II) ions was quantitative in the pH range of 1.0–4.5, whereas quantitative desorption occurs with 3.0 mL 0.4 mol L?1 thiourea. The amount of eluted palladium was measured using flame atomic absorption spectrometry. The effects of experimental parameters, including sample flow rate, eluent flow rate, and eluent concentration were investigated. The effect of coexisting ions showed no interference from most ions tested. The proposed method permitted a large enrichment factor (about 200). The relative standard deviation of the method was ±2.73% (for eight replicate determination of 2.0 μg mL?1 of Pd(II)) and the limit of detection was 0.3 ng mL?1. The method was applied to the determination of Pd(II) in water, road dust, and standard samples.  相似文献   

16.
We developed a simple strategy for designing a sensitive electrochemical stripping voltammetric sensor for organophosphate pesticides (OPs) based on solid-phase extraction (SPE) using nanosized Pt intercalated Ni/Al layered double hydroxides (labeled as NanoPt-LDHs). By assembling NanoPt with LDHs together, the resulting NanoPt-LDHs are highly efficient to capture OPs. It dramatically facilitates the enrichment of OPs onto their surface and realizes the sensitive stripping voltammetric detection of methyl parathion (MP) as a model of OPs. The stripping analysis shows highly linear over MP concentration ranges of 0.001–0.15 and 0.3–1.0 μg mL? 1 with a detection limit of 0.6 ng mL–1 (S/N = 3). The combination of NanoPt, LDHs, SPE, and square-wave voltammetry (SWV) provides a fast, simple, and sensitive electrochemical method for OPs.  相似文献   

17.
Electrochemical immunosensors based on single wall nanotube (SWNT) forests and 5 nm glutathione-protected gold nanoparticles (GSH-AuNP) were developed and compared for the measurement of human cancer biomarker interleukin-6 (IL-6) in serum. Detection was based on sandwich immunoassays using multiple (14–16) horseradish peroxidase labels conjugated to a secondary antibody. Performance was optimized by effective blocking of non-specific binding (NSB) of the labels using bovine serum albumin. The GSH-AuNP immunosensor gave a detection limit (DL) of 10 pg mL?1 IL-6 (500 amol mL?1) in 10 μL calf serum, which was 3-fold better than 30 pg mL?1 found for the SWNT forest immunosensor for the same assay protocol. The GSH-AuNPs platform also gave a much larger linear dynamic range (20–4000 pg mL?1) than the SWNT system (40–150 pg mL?1), but the SWNTs had 2-fold better sensitivity in the low pg mL?1 range.  相似文献   

18.
A novel and sensitive electrochemiluminescence (ECL) immunosensor based on CdS quantum dots (QDs)-carbon nanotubes (CNTs) and gold nanoparticles-chitosan (GNPs-CHIT) was presented. CdS QDs ECL was much enhanced by combing poly(diallyldimethylammonium chloride) functionalized CNTs. GNPs-CHIT nanohybrids was used to construct an effective antibody immobilization matrix with excellent stability and bioactivity. The principle of ECL detection for target human IgG is based on the increment of steric hindrance after immunoreaction, which resulted in the decrease in ECL intensity. The linear response range was between 0.006 and 150 ng mL?1, and the detection limit was 0.001 ng mL?1. This approach offers obvious advantages of being simpler, faster, and more stable compared with other immunosensors, which possesses great potential for protein detection in clinical laboratory.  相似文献   

19.
Analytical performances of metal coated slotted quartz tube flame atomic absorption spectrometry (SQT-FAAS) and slotted quartz tube in situ atom trapping flame atomic absorption spectrometry (SQT-AT-FAAS) systems were evaluated for determination of Bi. Non-volatile elements such as Mo, Zr, W and Ta were tried as coating materials. It was observed that W-coated SQT gave the best sensitivity for the determination of Bi for SQT-FAAS and SQT-AT-FAAS. The parameters for W-coated SQT-FAAS and W-coated SQT-AT-FAAS were optimized. Sensitivity of FAAS for Bi was improved as 4.0 fold by W-coated SQT-FAAS while 613 fold enhancement in sensitivity was achieved by W-coated SQT-AT-FAAS using 5.0 min trapping with respect to conventional FAAS. MIBK was selected as organic solvent for the re-atomization of Bi from the trapping surface. Limit of detection values for W-coated SQT-FAAS and W-coated SQT-AT-FAAS was obtained as 0.14 μg mL 1 and 0.51 ng mL 1, respectively. Linear calibration plot was obtained in the range of 2.5–25.0 ng mL 1 for W-coated SQT-AT-FAAS. Accuracy of the W-coated SQT-AT-FAAS system was checked by analyzing a standard reference material, NIST 1643e.  相似文献   

20.
Highly luminescent LaF3:Ce3+/Tb3+ nanocrystals were successfully prepared and surface functionalized via Layer-by-Layer technology. These as-prepared nanocrystals are highly resistant to photobleaching and pretty dispersible in aqueous solution. Due to the efficient luminescence quenching of the nanocrystals by nucleic acids, a facile fluorescence quenching method was developed for the detection of trace amount of nucleic acids. Under optimal conditions, the fluorescence intensity was proportional to the DNA concentration over the range of 0.60–25.0 μg mL?1 for calf thymus DNA (ct-DNA) and 0.60–30.0 μg mL?1 for herring sperm DNA (hs-DNA), respectively. The corresponding detection limit is 0.21 μg mL?1 for ct-DNA and 0.31 μg mL?1 for hs-DNA, respectively. The results indicated that the reported method is simple and rapid with wide linear range. Also, the recovery and relative standard deviation of this method are reasonable and satisfactory.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号