共查询到20条相似文献,搜索用时 15 毫秒
1.
Christiane Béatrice Duyck Tatiana Dillenburg Saint'PierreNorbert Miekeley Teresa Cristina Oliveira da FonsecaPeter Szatmari 《Spectrochimica Acta Part B: Atomic Spectroscopy》2011,66(5):362-367
A method was developed for the determination of V and Ni as tetrapyrroles by High Performance Liquid Chromatography hyphenated to Inductively Coupled Plasma Mass Spectrometry (HPLC-ICP-MS) using reversed phase and elution gradient. Chlorinated solvents and tetrahydrofuran were investigated as regard to separation time and ICP-MS detection efficiencies. The final elution gradient program started from pure methanol to a mixture of 20:80 (v/v) chloroform:methanol. External quantification of V and Ni with inorganic standards by flow injection ICP-MS, used online with HPLC, resulted in 95% of recoveries. The Limits of Detection for V during methanol elution and for Ni during the 20% chloroform gradient elution were evaluated by their minimum detectable concentrations, which were, respectively, 5 μg L− 1 and 8 μg L− 1. The methodology was applied to polar and resin fractions separated from a Brazilian crude oil and a sediment extract from an oil-polluted area in the Guanabara Bay, Rio de Janeiro, Brazil. Vanadium as tetrapyrroles represented the totality of V content in the polar fraction, whereas Ni was in different polar forms in the resin and sediment extract. 相似文献
2.
Siethoff C Feldmann I Jakubowski N Linscheid M 《Journal of mass spectrometry : JMS》1999,34(4):421-426
The quantitative determination of nucleotides from DNA modified by styrene oxide is described using a combination of inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) and electrospray ionization mass spectrometry (ESI-MS), both interfaced to reversed-phase high-performance liquid chromatography (HPLC). LC/ICP-MS (resolution > 1500 to discriminate against 15N16O+ and 14N16OH+) was employed to determine quantitatively the content of modified nucleotides in standard solutions based on the signal of phosphorus; phosphoric acid served as an internal standard. By means of the standard addition technique the sensitivity of the LC/ESI-MS approach was subsequently determined. Since a comparison of UV, ICP and ESI-MS data suggested that in ESI-MS the ionization efficiency of the adducts is identical within the error limits, quantitative determination of all adducts is possible. For LC/ESI-MS with single ion monitoring, the detection limit for styrene oxide adducts of nucleotides was determined to be 20 pg absolute or 14 modified in 10(8) unmodified nucleotides in a 5 micrograms DNA sample, which comes close to the best methods available for the detection of chemical modifications in DNA. 相似文献
3.
Arsenic composes a danger for human health all over the world as it is responsible for water resources contamination. The toxicity of arsenic depends on its chemical form. However, occurrence of particular arsenic species is dependent on processes occurring in water. Nowadays, more arsenic species is detected and analyzed in different kind of water (mineral, tap, waste), mainly owing to great possibilities resulting from coupling high performance liquid chromatography (HPLC) with inductively coupled plasma mass spectrometry (ICP-MS). This review mainly describes arsenic speciation analysis by HPLC-ICP-MS technique on the basis of articles that have been published since 2000. Arsenic chemistry, occurrence in different kind of water, total arsenic determination with interferences elimination and its validation and analytical performance are also reviewed. 相似文献
4.
Sylwia Studzińska Sandra Mounicou Joanna Szpunar Ryszard Łobiński Bogusław Buszewski 《Analytica chimica acta》2015
This text presents a novel method for the separation and detection of phosphorothioate oligonucleotides with the use of ion pair ultra high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry The research showed that hexafluoroisopropanol/triethylamine based mobile phases may be successfully used when liquid chromatography is coupled with such elemental detection. However, the concentration of both HFIP and TEA influences the final result. The lower concentration of HFIP, the lower the background in ICP-MS and the greater the sensitivity. The method applied for the analysis of serum samples was based on high resolution inductively coupled plasma mass spectrometry. Utilization of this method allows determination of fifty times lower quantity of phosphorothioate oligonucleotides than in the case of quadrupole mass analyzer. Monitoring of 31P may be used to quantify these compounds at the level of 80 μg L−1, while simultaneous determination of sulfur is very useful for qualitative analysis. Moreover, the results presented in this paper demonstrate the practical applicability of coupling LC with ICP-MS in determining phosphorothioate oligonucleotides and their metabolites in serum within 7 min with a very good sensitivity. The method was linear in the concentration range between 0.2 and 3 mg L−1. The limit of detection was in the range of 0.07 and 0.13 mg L−1. Accuracy varied with concentration, but was in the range of 3%. 相似文献
5.
A method developed to determine organic and inorganic selenium species in human urine samples is presented in detail. After a simple sample treatment based on elimination of non-charged organic compounds, selenium species were separated by high performance liquid chromatography (HPLC) on a Spherisorb 5 ODS/AMINO column using two different chromatographic conditions: phosphate buffers at pH 2.8 and 6.0. Detection was carried out using an on-line inductively coupled plasma mass spectrometer (ICP-MS). Trimethylselenonium ion and two unknown selenium species in urine samples were found. Selenium species were shown to have stability problems, with the maximum allowed storage time of 1 week. 相似文献
6.
7.
Duckett CJ Bailey NJ Walker H Abou-Shakra F Wilson ID Lindon JC Nicholson JK 《Rapid communications in mass spectrometry : RCM》2002,16(4):245-247
The use of directly coupled high performance liquid chromatography/inductively coupled plasma mass spectroscopy (HPLC/ICPMS) employing chlorine ((35)Cl/(37)Cl) detection has been investigated with respect to the detection and quantitation of the drugs diclofenac and chlorpromazine. By integration of peak areas in the 'chloratogram' (the chlorine specific HPLC chromatogram), a calibration curve was constructed, from which the concentrations could be determined. Chlorine detected HPLC/ICPMS is quantitative over a wide range of concentrations of pharmaceutical relevance for metabolite detection and the results reproducible (standard deviation +/- 0.43%) over multiple injections. Application of gradient chromatography and variation in the bulk mobile phase physicochemical properties has little effect on the ICPMS detection response for these compounds. This work indicates that the use of HPLC/ICPMS is likely to be quantitatively reliable for metabolism studies for a range of chlorinated xenobiotics. 相似文献
8.
Smith C Jensen BP Wilson ID Abou-Shakra F Crowther D 《Rapid communications in mass spectrometry : RCM》2004,18(13):1487-1492
High-performance liquid chromatography (HPLC) combined with inductively coupled plasma mass spectrometry (ICPMS) has been studied as a means for the detection of carbon to provide a 'universal' method for detecting organic compounds in chromatographic eluents. Carbon is particularly difficult to ionise and the amount of carbon present in normal chromatographic systems leads to high backgrounds, making detection a challenge. Novel separation approaches were therefore employed, using either entirely aqueous eluents (at temperatures of 60 and 160 degrees C, dependent on the column used) to eliminate the organic modifier completely, or isotopically enriched solvents. For the aqueous eluents, detection limits for sulphanilamide were found to be 2.26 microg, corresponding to 1.13 micromol (0.47 micromol of carbon), injected on a conventional 4.6 mm i.d. column. The use of a narrow bore column with highly isotopically enriched 12C-methanol (99.95 atom%) as organic modifier for the mobile phase enabled the detection of 86 micromol for 13C-triple-labelled caffeine and 79 micromol for 13C-double-labelled phenacetin. The sensitive detection of 12C-compounds with 13C-enriched methanol as organic modifier proved impractical due to a lower level of isotopic enrichment (99 atom%) of this solvent, with the residual 12C-methanol resulting in significant interference. 相似文献
9.
A simple and sensitive method for the speciation of vanadium(III), (IV), and (V) was developed by using high performance liquid chromatography and inductively coupled plasma mass spectrometry (HPLC-ICPMS). The EDTA-complexed vanadium species were separated on a strong anion exchange column with an eluent containing 2 mM EDTA, 3% acetonitrile, and 80 mM ammonium bicarbonate at pH 6. Each analysis was complete in 5 min. The detection limits were 0.6, 0.7 and 1.0 μg L−1 for V(III), V(IV), and V(V), respectively. The method was applied to coke pore water samples from an oilsand processing/upgrading site in Fort McMurray, Alberta, Canada and to Shewanella putrefaciens CN32 bacterial cultures incubated with V(V). In the coke pore water samples, V(IV) and V(V) were found to be the major species. For the first time, V(III) was detected in the bacterial cultures incubated with V(V). 相似文献
10.
Arsenic and its speciation analysis using high-performance liquid chromatography and inductively coupled plasma mass spectrometry 总被引:10,自引:0,他引:10
It is known that arsenic has different toxicological properties dependent upon both its oxidation state for inorganic compounds, as well as the different toxicity levels exhibited for organic arsenic compounds. The field of arsenic speciation analysis has grown rapidly in recent years, especially with the utilization of high-performance liquid chromatography (HPLC) coupled to inductively coupled plasma mass spectrometry (ICP-MS), a highly sensitive and robust detector system. Complete characterization of arsenic compounds is necessary to understand intake, accumulation, transport, storage, detoxification and activation of this element in the natural environment and living systems. This review describes the essential background and toxicity of arsenic in the environment, and more importantly, some currently used chromatographic applications and sample handling procedures necessary to accurately detect and quantify arsenic in its various chemical forms. Applications and work using only HPLC-ICP-MS for arsenic speciation of environmental and biological samples are presented in this review. 相似文献
11.
Daniela KretschyAuthor Vitae Gunda KoellenspergerAuthor VitaeStephan Hann 《Analytica chimica acta》2012
This article reviews novel quantification concepts where elemental labelling is combined with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS) or liquid chromatography inductively coupled plasma mass spectrometry (LC–ICP-MS), and employed for quantification of biomolecules such as proteins, peptides and related molecules in challenging sample matrices. In the first sections an overview on general aspects of biomolecule quantification, as well as of labelling will be presented emphasizing the potential, which lies in such methodological approaches. In this context, ICP-MS as detector provides high sensitivity, selectivity and robustness in biological samples and offers the capability for multiplexing and isotope dilution mass spectrometry (IDMS). Fundamental methodology of elemental labelling will be highlighted and analytical, as well as biomedical applications will be presented. A special focus will lie on established applications underlining benefits and bottlenecks of such approaches for the implementation in real life analysis. Key research made in this field will be summarized and a perspective for future developments including sophisticated and innovative applications will given. 相似文献
12.
Trong-Mui Do Hui-Fang Hsieh Wei-Ciang Chang E.-E. Chang Chu-Fang Wang 《Spectrochimica Acta Part B: Atomic Spectroscopy》2011,66(8):610-618
In this study we developed a dried-droplet method for laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method provides accurate and precise results when building calibration curves and determining elements of interest in real liquid samples. After placing just 1 μL of a liquid standard solution or a real sample onto the filter surface and then converting the solution into a very small, thin dry spot, the sample could be applied as an analytical subject for LA. To demonstrate the feasibility of this proposed method, we used LA-ICP-MS and conventional ICP-MS to determine the levels of 13 elements (Li, V, Mn, Co, Ni, Cu, Zn, As, Mo, Cd, Sb, Tl, and Pb) in five water samples. The correlation coefficients obtained from the various calibration curves ranged from 0.9920 (205Tl) to 0.9998 (51V), sufficient to allow the determination of a wide range of elements in the samples. We also investigated the effects of Methylene Blue (MB) and the NaCl concentration on the elemental analyses. MB could be used as an indicator during the ablation process; its presence in the samples only negligibly influenced the intensities of the signals of most of the tested elements. Notably, high NaCl contents led to signal suppression for some of the elements. In comparison with the established sample introduction by nebulization, our developed technique abrogates the need for time-consuming sample preparation and reduces the possibility of sample contamination. 相似文献
13.
Axelsson BO Jörnten-Karlsson M Michelsen P Abou-Shakra F 《Rapid communications in mass spectrometry : RCM》2001,15(6):375-385
Quantification of unknown components in pharmaceutical, metabolic and environmental samples is an important but difficult task. Most commonly used detectors (like UV, RI or MS) require standards of each analyte for accurate quantification. Even if the chemical structure or elemental composition is known, the response from these detectors is difficult to predict with any accuracy. In inductively coupled plasma mass spectrometry (ICP-MS) compounds are atomised and ionised irrespective of the chemical structure(s) incorporating the element of interest. Liquid chromatography coupled with inductively coupled plasma mass spectrometry (LC/ICP-MS) has been shown to provide a generic detection for structurally non-correlated compounds with common elements like phosphorus and iodine. Detection of selected elements gives a better quantification of tested 'unknowns' than UV and organic mass spectrometric detection. It was shown that the ultrasonic nebuliser did not introduce any measurable dead volume and preserves the separation efficiency of the system. ICP-MS can be used in combination with many different mobile phases ranging from 0-100% organic modifier. The dynamic range was found to exceed 2.5 orders of magnitude. The application of LC/ICP-MS to pharmaceutical drugs and formulations has shown that impurities can be quantified below the 0.1 mol-% level. 相似文献
14.
Summary An ICP-MS detector in combination with HPLC has been evaluated for the analysis of six arsenic compounds. The influence of the presence of an organic modifier in the mobile phase on arsenic response and the quality parameters of the analysis are discussed. Detection limits for arsenic species under study range from 10 to 30 pg. The determination of arsenic compounds in solutions simulating fish or sediment extracts has been used to demonstrate the applicability of this technique. 相似文献
15.
This paper describes the use of chemical reaction interface mass spectrometry (CRIMS) combined with liquid chromatography for the detection of trace level sulfur-containing impurities in pharmaceutical materials. A mixture of sulfur- and non-sulfur-containing compounds were analyzed initially to test the system. Then the determination of trace level impurities in a cimetidine drug substance was carried out. Detection of sulfur-containing impurities at less than 0.1% of the major component was obtained with good linearity. The results obtained are consistent with the expected results for this sample and illustrate the applicability of the technique. 相似文献
16.
Shin-ichiro Fujii Kazumi InagakiAkiko Takatsu Takashi YaritaKoichi Chiba 《Journal of chromatography. A》2009,1216(44):7488-7492
We performed the quantification of phosphorus in deoxynucleotides using capillary electrophoresis (CE) and micro-HPLC (μHPLC) hyphenated with inductively coupled plasma mass spectrometry (ICP-MS). DNA and its component units have conventionally been determined by photometry; however, more selective and sensitive methods are needed for small biological samples. CE and μHPLC offer the advantages of good separation and small consumption of samples, and ICP-MS is a highly sensitive technique for the determination of a chemical element. Therefore, we have developed an interface device for combining CE and μHPLC with ICP-MS for quantifying nucleotides based on phosphorus content. The interface utilizes 4.5 μL/min for nebulizing and effective introduction of the sample into ICP. The samples of nucleotides and free phosphoric acid were well separated in the CE–ICP-MS measurement, and the calibration curves (1–100 μg/mL) of the nucleotides showed a linear (R2 > 0.999) increase in intensity. Similarly, the samples of nucleotides were baseline separated using μHPLC–ICP-MS, and the calibration curves of the nucleotides were linear (R2 > 0.998). The detection limits of these species and phosphorus in nucleotides using CE–ICP-MS and μHPLC–ICP-MS were 0.77–6.5 ng/mL and 4.0–6.5 ng/mL, respectively. These values were about one or two orders lower than those in a previous report. The sample volumes of these experiments were calculated to be about 10 nL and 50 nL per analysis. Therefore, these analytical methods have the potential to be useful for the determination of biological samples, such as DNA and RNA molecules. 相似文献
17.
Wille K Claessens M Rappé K Monteyne E Janssen CR De Brabander HF Vanhaecke L 《Journal of chromatography. A》2011,1218(51):9162-9173
The presence of both pharmaceuticals and pesticides in the aquatic environment has become a well-known environmental issue during the last decade. An increasing demand however still exists for sensitive and reliable monitoring tools for these rather polar contaminants in the marine environment. In recent years, the great potential of passive samplers or equilibrium based sampling techniques for evaluation of the fate of these contaminants has been shown in literature. Therefore, we developed a new analytical method for the quantification of a high number of pharmaceuticals and pesticides in passive sampling devices. The analytical procedure consisted of extraction using 1:1 methanol/acetonitrile followed by detection with ultra-high performance liquid chromatography coupled to high resolution and high mass accuracy Orbitrap mass spectrometry. Validation of the analytical method resulted in limits of quantification and recoveries ranging between 0.2 and 20 ng per sampler sheet and between 87.9 and 105.2%, respectively. Determination of the sampler-water partition coefficients of all compounds demonstrated that several pharmaceuticals and most pesticides exert a high affinity for the polydimethylsiloxane passive samplers. Finally, the developed analytical methods were used to measure the time-weighted average (TWA) concentrations of the targeted pollutants in passive samplers, deployed at eight stations in the Belgian coastal zone. Propranolol, carbamazepine and seven pesticides were found to be very abundant in the passive samplers. These obtained long-term and large-scale TWA concentrations will contribute in assessing the environmental and human health risk of these emerging pollutants. 相似文献
18.
An analytical method for the speciation of selenomethionine, selenocystine, selenite and selenate by high performance liquid
chromatography (HPLC) with atomic spectrometric detection is presented. An organic polymeric strong anion exchange column
was used as the stationary phase in combination with an aqueous solution of 6 mmol L–1 of salicylate ion at pH 8.5 as the mobile phase which allowed the isocratic separation of the four selenium analytes within
8 minutes. The separated selenium species were detected on-line by flame atomic absorption spectrometry (FAAS) or inductively
coupled plasma mass spectrometry (ICP-MS). The signal-to-noise ratio of the FAAS detector was optimized using a hydrogen-argon
entrained-air flame and a slotted-tube atom trap (STAT) in the flame. The limit of detection (3 σ) achieved by the HPLC-FAAS
system was 1 mg L–1 of selenium (100 μL injections) for each of the four selenium species. More powerful selenium detection was achieved using
an ELAN 5000 ICP-MS instrument. Selenium was measured at m/z = 82. The ICP-MS signal intensity was enhanced by a factor of
3–4 after addition of 3% methanol to the chromatographic mobile phase and by using an increased plasma power input of 1300
W. The limit of detection achieved under these conditions was 1 μg L–1 (100 μL injections). The HPLC-ICP-MS system was used for selenium speciation of selenite and selenate in aqueous solutions
during a BCR certification exercise and for selenium speciation in the certified reference material, BCR No. 402 White Clover.
Extraction experiments revealed that the selenium species in the biological material were extractable only in the presence
of water in the extraction medium. The results indicated that selenate and a compound of unknown identity U were present in
the plant sample.
Received: 4 September 1996 / Accepted: 12 December 1996 相似文献
19.
Summary A method for the determination of elements in liquids using inductively coupled plasma mass spectrometry (ICP-MS) is described. The different possibilities and problems together with instrumental parameters are reviewed. After the dissolution step samples are analyzed directly without any preconcentration. Detection limits for 53 elements have been tested and are found to be less than 0.1 ng/ml. Monoisotopic elements can be detected at levels less than 0.05 ng/ml. Interference problems have been studied and hints are given to predict molecular species using algorithm implemented in software packages. The application to trace element analysis in the geological field is demonstrated with a basalt reference sample to verify figures of merit for this method. Accuracy is checked with a NBS SRM steel sample.
Erfahrungen und Möglichkeiten mit der Anwendung eines induktiv gekoppelten Plasma/Massenspektrometer Systems相似文献
20.
An analytical method for the speciation of selenomethionine, selenocystine, selenite and selenate by high performance liquid chromatography (HPLC) with atomic spectrometric detection is presented. An organic polymeric strong anion exchange column was used as the stationary phase in combination with an aqueous solution of 6 mmol L–1 of salicylate ion at pH 8.5 as the mobile phase which allowed the isocratic separation of the four selenium analytes within 8 minutes. The separated selenium species were detected on-line by flame atomic absorption spectrometry (FAAS) or inductively coupled plasma mass spectrometry (ICP-MS). The signal-to-noise ratio of the FAAS detector was optimized using a hydrogen-argon entrained-air flame and a slotted-tube atom trap (STAT) in the flame. The limit of detection (3 σ) achieved by the HPLC-FAAS system was 1 mg L–1 of selenium (100 μL injections) for each of the four selenium species. More powerful selenium detection was achieved using an ELAN 5000 ICP-MS instrument. Selenium was measured at m/z = 82. The ICP-MS signal intensity was enhanced by a factor of 3–4 after addition of 3% methanol to the chromatographic mobile phase and by using an increased plasma power input of 1300 W. The limit of detection achieved under these conditions was 1 μg L–1 (100 μL injections). The HPLC-ICP-MS system was used for selenium speciation of selenite and selenate in aqueous solutions during a BCR certification exercise and for selenium speciation in the certified reference material, BCR No. 402 White Clover. Extraction experiments revealed that the selenium species in the biological material were extractable only in the presence of water in the extraction medium. The results indicated that selenate and a compound of unknown identity U were present in the plant sample. 相似文献