首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Wang K  Xu JJ  Tang KS  Chen HY 《Talanta》2005,67(4):798-805
A novel solid-contact potentiometric sensor for ascorbic acid based on cobalt phthalocyanine nanoparticles (NanoCoPc) as ionophore was fabricated without any need of auxiliary materials (such as membrane matrix, plasticizer, and other additives). The electrode was prepared by simple drop-coating NanoCoPc colloid on the surface of a glassy carbon electrode. A smooth, bright and blue thin film was strongly attached on the surface of the glassy carbon electrode. The electrode showed high selectivity for ascorbic acid, as compared with many common anions. The influences of the amount of NanoCoPc at the electrode surface and pH on the response characteristics of the electrode were investigated. To overcome the instability of the formal potential of the coated wire electrode, a novel electrochemical pretreatment method was proposed for the potentiometric sensor based on redox mechanism. This resulting sensor demonstrates potentiometric response over a wide linear range of ascorbic acid concentration (5.5 × 10−7 to 5.5 × 10−2 M) with a fast response (<15 s), lower detection limit (ca. 1.0 × 10−7 M), and a long-term stability. Furthermore, microsensors based on different conductors (carbon fiber and Cu wire) were also successfully fabricated for the determination of practical samples.  相似文献   

2.
A novel electrode was developed through electrodepositing gold nanoparticles (GNPs) on overoxidized-polyimidazole (PImox) film modified glassy carbon electrode (GCE). The combination of GNPs and the PImox film endowed the GNPs/PImox/GCE with good biological compatibility, high selectivity and sensitivity and excellent electrochemical catalytic activities towards ascorbic acid (AA), dopamine (DA), uric acid (UA) and tryptophan (Trp). In the fourfold co-existence system, the peak separations between AA–DA, DA–UA and UA–Trp were large up to 186, 165 and 285 mV, respectively. The calibration curves for AA, DA and UA were obtained in the range of 210.0–1010.0 μM, 5.0–268.0 μM and 6.0–486.0 μM with detection limits (S/N = 3) of 2.0 μM, 0.08 μM and 0.5 μM, respectively. Two linear calibrations for Trp were obtained over ranges of 3.0–34.0 μM and 84.0–464.0 μM with detection limit (S/N = 3) of 0.7 μM. In addition, the modified electrode was applied to detect AA, DA, UA and Trp in samples using standard addition method with satisfactory results.  相似文献   

3.
We report a new nonenzymatic amperometric detection of ascorbic acid (AA) using a glassy carbon (GC) disk electrode modified with hollow gold/ruthenium (hAu–Ru) nanoshells, which exhibited decent sensing characteristics. The hAu–Ru nanoshells were prepared by the incorporation of Ru on hollow gold (hAu) nanoshells from Co nanoparticle templates, which enabled AA selectivity against glucose without aid of enzyme or membrane. The structure and electrocatalytic activities of the hAu–Ru catalysts were characterized by spectroscopic and electrochemical techniques. The hAu–Ru loaded on GC electrode (hAu–Ru/GC) showed sensitivity of 426 μA mM−1 cm−2 (normalized to the GC disk area) for the linear dynamic range of <5 μM to 2 mM AA at physiological pH. The response time and detection limit were 1.6 s and 2.2 μM, respectively. Furthermore, the hAu–Ru/GC electrode displayed remarkable selectivity for ascorbic acid over all potential biological interferents, including glucose, uric acid (UA), dopamine (DA), 4-acetamidophenol (AP), and nicotinamide adenine dinucleotide (NADH), which could be especially good for biological sensing.  相似文献   

4.
A novel amperometric biosensor utilizing two enzymes, glucose oxidase (GOD) and horseradish peroxidase (HRP), was developed for the cathodic detection of glucose. The glucose biosensor was constructed by electrochemical formation of a polypyrrole (PPy) membrane in the presence of GOD on the surface of a HRP-modified sol-gel derived-mediated ceramic carbon electrode. Ferrocenecarboxylic acid (FCA) was used as mediator to transfer electron between enzyme and electrode. In the hetero-bilayer configuration of electrode, all enzymes were well immobilized in electrode matrices and showed favorable enzymatic activities. The amperometric detection of glucose was carried out at +0.16 V (versus saturated calomel reference electrode (SCE)) in 0.1 M phosphate buffer solution (pH 6.9) with a linear response range between 8.0×10−5 and 1.3×10−3 M glucose. The biosensor showed a good suppression of interference in the amperometric detection.  相似文献   

5.
A novel plant tissue-based bioelectrode obtained by incorporating sunflower (Helianthus annuus L.) leaves tissue as a source of glycolate oxidase and peroxidase into a ferrocene-mediated carbon paste electrode for the determination of glycolic acid was developed. It was coupled with the flow-injection (FI) system and used as the basis to develop a novel FI amperometric procedure for glycolic acid determination. The flow-injection amperometric measurements were performed by injecting aliquot of glycolic acid solution into the flowing stream of 0.05 mol L−1 of phosphate buffer solution having pH 8.0 with a flow rate of 0.3 mL min−1. The bioelectrode consisted of 20% (w/w) of sunflower leaves tissue and 5% (w/w) of ferrocene at 0.00 V (vs Ag/AgCl). The bioelectrode exhibited a linear response from 1.0 × 10−6 up to 2.0 × 10−3 mol L−1 glycolic acid with a detection limit (S/N = 3) and a quantitation limit (S/N = 10) of 1 × 10−6 and 3.3 × 10−6 mol L−1, respectively. The sampling rate of 12 h−1 and a relative standard deviation of 1.67% (n = 15) were achieved. The bioelectrode response decreased to 70% of the original value within 90 continuous injections. The proposed bioelectrode was satisfactorily applied to glycolic acid determination in human urine samples after appropriate sample pretreatment. Results obtained by the FI method were compared favorably with those obtained by HPLC. It offers advantages, which included rapidity, high activity, limited stability, ease of preparation and low cost.  相似文献   

6.
We report for the first time the use of polyhistidine (Polyhis) to efficiently disperse multiwall carbon nanotubes (MWCNTs). The optimum dispersion MWCNT–Polyhis was obtained by sonicating for 30 min 1.0 mg mL−1 MWCNTs in 0.25 mg mL−1 Polyhis solution prepared in 75:25 (v/v) ethanol/0.200 M acetate buffer solution pH 5.00. The dispersion was characterized by scanning electron microscopy, and by cyclic voltammetry and amperometry using ascorbic acid as redox marker. The modification of glassy carbon electrodes with MWCNT–Polyhis produces a drastic decrease in the overvoltage for the oxidation of ascorbic acid (580 mV) at variance with the response observed at glassy carbon electrodes modified just with Polyhis, where the charge transfer is more difficult due to the blocking effect of the polymer. The reproducibility for the sensitivities obtained after 10 successive calibration plots using the same surface was 6.3%. The MWCNT-modified glassy carbon electrode demonstrated to be highly stable since after 45 days storage at room temperature the response was 94.0% of the original. The glassy carbon electrode modified with MWCNT–Polyhis dispersion was successfully used to quantify dopamine or uric acid at nanomolar levels, even in the presence of large excess of ascorbic acid. Determinations of uric acid in human blood serum samples demonstrated a very good correlation with the value reported by Wienner laboratory.  相似文献   

7.
The electrochemical responses of tannic acid have been obtained at porous pseudo-carbon paste electrode (PPCPE), polypyrrole modified carbon paste electrode (PCPE), SBA-15 modified CPE (SBA-MCPE) and carbon paste electrode (CPE) under same conditions, respectively. The results show that the sensitivity of PPCPE is the highest among all the checked electrodes. The detection limit at PPCPE is 0.01 μM, which is about 10 times lower than that at CPE and is about 5 times lower than that at PCPE or SBA-MCPE. The developed electrode PPCPE possesses a few obvious advantages and no binding reagents are needed. The surface area of PPCPE is 59.26 m2 g−1 with pores ranging from 2 to 5 μm in diameter. The PPCPE is easy to preserve and has good reusability, which affords a nice electrochemical platform for detecting tannic acid.  相似文献   

8.
We are proposing for the first time the use of a Nafion/multi-walled carbon nanotubes dispersion deposited on glassy carbon electrodes (GCE) as a new platform for developing enzymatic biosensors based on the self-assembling of a chitosan derivative and different oxidases. The electrodes are obtained by deposition of a layer of Nafion/multi-wall carbon nanotubes dispersion on glassy carbon electrodes, followed by the adsorption of a chitosan derivative as polycation and glucose oxidase, l-aminoacid oxidase or polyphenol oxidase, as polyanions and biorecognition elements. The optimum configuration for glucose biosensors has allowed a highly sensitive (sensitivity = (0.28 ± 0.02) μA mM−1, r = 0.997), fast (4 s in reaching the maximum response), and highly selective (0% interference of ascorbic acid and uric acid at maximum physiological levels) glucose quantification at 0.700 V with detection and quantification limits of 0.035 and 0.107 mM, respectively. The repetitivity for 10 measurements was 5.5%, while the reproducibility was 8.4% for eight electrodes. The potentiality of the new platform was clearly demonstrated by using the carbon nanotubes/Nafion layer as a platform for the self-assembling of l-aminoacid oxidase and polyphenol oxidase. Therefore, the platform we are proposing here, that combines the advantages of nanostructured materials with those of the layer-by-layer self-assembling of polyelectrolytes, opens the doors to new and exciting possibilities for the development of enzymatic and affinity biosensors using different transdution modes.  相似文献   

9.
Chen L  Chen W  Ma C  Du D  Chen X 《Talanta》2011,84(1):104-108
A novel solid-phase microextraction (SPME) fiber coated with multiwalled carbon nanotubes/polypyrrole (MWCNTs/Ppy) was prepared with an electrochemical method and used for the extraction of pyrethroids in natural water samples. The results showed that the MWCNTs/Ppy coated fiber had high organic stability, and remarkable acid and alkali resistance. In addition, the MWCNTs/Ppy coated fiber was more effective and superior to commercial PDMS and PDMS/DVD fibers in extracting pyrethroids in natural water samples. Under optimized conditions, the calibration curves were found to be linear from 0.001 to 10 μg mL−1 for five of the six pyrethroids studied, the exception being fenvalerate (which was from 0.005 to 10 μg mL−1), and detection limits were within the range 0.12-0.43 ng mL−1. The recoveries of the pyrethroids spiked in water samples at 10 ng mL−1 ranged from 83 to 112%.  相似文献   

10.
A fullerene-C60-modified glassy carbon electrode (GCE) is used for the simultaneous determination of adenosine and guanosine by differential pulse voltammetry. Compared to a bare glassy carbon electrode, the modified electrode exhibits an apparent shift of the oxidation potentials in the cathodic direction and a marked enhancement in the voltammetric peak current response for both the biomolecules. Linear calibration curves are obtained over the concentration range 0.5 μM-1.0 mM in 0.1 M phosphate buffer solution at pH 7.2 with a detection limit of 3.02 × 10−7 M and 1.45 × 10−7 M for individual determination of adenosine and guanosine, respectively. The interference studies showed that the fullerene-C60-modified glassy carbon electrode exhibited excellent selectivity in the presence of hypoxanthine, xanthine, uric acid and ascorbic acid. The proposed procedure was successfully applied to detect adenosine and guanosine in human blood plasma and urine, without any preliminary pre-treatment.  相似文献   

11.
Platinum nanoparticles were used in combination with multi-walled carbon nanotubes (MWCNTs) for fabricating sensitivity-enhanced electrochemical DNA biosensor. Multi-walled carbon nanotubes and platinum nanoparticles were dispersed in Nafion, which were used to fabricate the modification of the glassy carbon electrode (GCE) surface. Oligonucleotides with amino groups at the 5′ end were covalently linked onto carboxylic groups of MWCNTs on the electrode. The hybridization events were monitored by differential pulse voltammetry (DPV) measurement of the intercalated daunomycin. Due to the ability of carbon nanotubes to promote electron-transfer reactions, the high catalytic activities of platinum nanoparticles for chemical reactions, the sensitivity of presented electrochemical DNA biosensors was remarkably improved. The detection limit of the method for target DNA was 1.0 × 10−11 mol l−1.  相似文献   

12.
In this study, an electrochemical ascorbic acid (AA) sensor was constructed based on a glassy carbon electrode modified with palladium nanoparticles supported on graphene oxide (PdNPs-GO). PdNPs with a mean diameter of 2.6 nm were homogeneously deposited on GO sheets by the redox reaction between PdCl42− and GO. Cyclic voltammetry and amperometric methods were used to evaluate the electrocatalytic activity towards the oxidation of AA in neutral media. Compared to a bare GC or a Pd electrode, the anodic peak potential of AA (0.006 V) at PdNPs-GO modified electrode was shifted negatively, and the large anodic peak potential separation (0.172 V) of AA and dopamine (DA), which could contribute to the synergistic effect of GO and PdNPs, was investigated. A further amperometric experiment proved that the proposed sensor was capable of sensitive and selective sensing of AA even in the presence of DA and uric acid. The modified electrode exhibited a rapid response to AA within 5 s and the amperometric signal showed a good linear correlation to AA concentration in a broad range from 20 μM to 2.28 mM with a correlation coefficient of R = 0.9991. Moreover, the proposed sensor was applied to the determination of AA in vitamin C tablet samples. The satisfactory results obtained indicated that the proposed sensor was promising for the development of novel electrochemical sensing for AA determination.  相似文献   

13.
Hocevar SB  Ogorevc B 《Talanta》2007,74(3):405-411
The present paper demonstrates the preparation and characterization of micro-electrodes based on carbon paste which is composed of carbon nano-particles with an average diameter of 30 nm and binding oil. The carbon paste electrode material is encased in pulled glass capillaries ranging in diameter from several tens down to less than ten micro-meters (r = 4.5 μm). Manipulation of the carbon paste micro-electrode (CPME) was accomplished via newly developed piston-driven system which construction and related problems are presented. Several parameters influencing the CPME performance including carbon paste composition and its electrochemical activation/preconditioning were investigated. Basic electrochemical behavior and properties were examined using typical redox system, i.e. potassium hexacyanoferrate. Applicability of the proposed carbon paste micro-electrode is illustrated by measuring some potentially interesting organic and inorganic analytes such as dopamine, ascorbic acid and selected heavy metals.  相似文献   

14.
This work offers construction and comparative evaluation the performance characteristics of conventional polymer (I), carbon paste (II) and carbon nanotubes chemically modified carbon paste ion selective electrodes (III) for meclofenoxate hydrochloride are described. These electrodes depend mainly on the incorporation of the ion pair of meclofenoxate hydrochloride with phosphomolybdic acid (PMA) or phosphotungestic acid (PTA). They showed near Nernestian responses over usable concentration range 1.0 × 10−5 to 1.0 × 10−2 M with slopes in the range 55.15–59.74 mV (concentration decade)−1. These developed electrodes were fully characterized in terms of their composition, response time, working concentration range, life span, usable pH and temperature range. The electrodes showed a very good selectivity for Meclo with respect to a large number of inorganic cations, sugars and in the presence of the degradation product of the drug (p-chloro phenoxy acetic acid). The standard additions method was applied to the determination of MecloCl in pure solution, pharmaceutical preparations and biological samples. Dissolution testing was also applied using the proposed sensors.  相似文献   

15.
Kyoungseon Min 《Talanta》2009,80(2):1007-191
A novel 3-dimensional single wall carbon nanotubes (SWNTs)-polypyrrole (Ppy) composite was prepared as an electrode by chemically polymerizing polypyrrole onto SWNTs using a LiClO4 oxidant. This composite electrode was characterized by scanning electron microscopy (SEM) and cyclic voltammetry with 1 mM [Fe(CN)6]−3/[Fe(CN)6]−4. The SWNTs were thickly coated with chemically polymerized polypyrrole and the composite had many surface pores and crevices which could enhance mass transfer. The SWNTs-Ppy composite electrode showed a large specific surface area (30 m2/g) and a good reproducible current response, at about 100 times the peak current of a glassy carbon electrode (GCE). The diffusion coefficient was calculated to be 4.81 × 10−6 cm2/s. As a biosensor application, tyrosinase was immobilized on the functionalized SWNTs and tyrosinase-SWNTs-Ppy composite was prepared in the same manner. This tyrosinase-SWNT-Ppy composite electrode was used for amperometric detection of dopamine in the presence of ascorbic acid and showed high sensitivity (467 mA/M cm2) and lower detection limit (5 μM) compared to previous reports.  相似文献   

16.
A novel anode material for lithium-ion batteries, tin nanoparticles coated with carbon embedded in graphene (Sn@C/graphene), was fabricated by hydrothermal synthesis and subsequent annealing. The structure and morphology of the nanocomposite were characterized by X-ray diffraction, scanning electron microscopy, and transmission electron microscopy. The size of the Sn@C nanoparticles is about 50-200 nm. The reversible specific capacity of the nanocomposite is ∼662 mAh g−1 at a specific current of 100 mA g−1 after 100 cycles, even ∼417 mAh g−1 at the high current of 1000 mA g−1. These results indicate that Sn@C/graphene possesses superior cycle performance and high rate capability. The enhanced electrochemical performances can be ascribed to the characteristic structure of the nanocomposite with both of the graphene and carbon shells, which buffer the volume change of the metallic tin and prevent the detachment and agglomeration of pulverized tin.  相似文献   

17.
A novel biochemical oxygen demand (BOD) sensing method employing a ferricyanide (FC) mediator immobilized in an ion-exchangeable polysiloxane was developed. The ion-exchangeable polysiloxane containing alkylammonium groups (PAPS-Cl) was synthesized by sol-gel reaction of 3-(aminopropyl)trimethoxysilane (APTMOS) catalyzed by hydrochloric acid. FC was combined in PAPS-Cl via ion-association and the product was labeled as PAPS-FC, which was employed for a modified glassy carbon electrode. The apparent diffusion coefficient (Dapp) of FC on the modified glassy carbon electrode was 9.8 × 10−11 cm2 s−1. In a three-electrode system, a linear relationship between the anodic current responses and glucose/glutamate (GGA) concentration was obtained up to 40 mg O2 L−1 (r = 0.994) when the reaction mixture was incubated for 30 min. Single sensor and piece-to-piece reproducibility were less than 3.8 and 7.7%, respectively. The effects of dissolved oxygen, pH, temperature and co-existing substances on the BOD responses were studied. The sensor responses to nine pure organic substances were compared with the conventional BOD5 method and other biosensor methods. Detection results of seawater samples were compared with those obtained from the BOD5 method and showed a good correlation (r = 0.988).  相似文献   

18.
Ozer ET  Güçer S 《Talanta》2011,84(2):362-367
The determination of six phthalate acid esters was achieved in artificial saliva using gas chromatography-mass spectrometry following activated carbon enrichment of samples. Central composite experimental design was applied to optimize method parameters, such as pH, adsorption time and amount of activated carbon. The best compromise of analytical conditions for the simultaneous determination of analytes from spiked artificial saliva were found to be: pH (3), adsorption time (30 min), activated carbon amount (1.8 g L−1) and elution solvent (chloroform). These conditions were applied to study the migration of phthalate acid esters from different children's toys into saliva. A horizontal agitation method was applied to extract the analytes from plastic toys into saliva for 2 h at 37 °C. The detection limits of the method were in the range of 1.3-5.1 μg L−1, while the relative standard deviation (%) values for the analysis of 100 μg L−1 of the analytes were below 3.0% (n = 5). Di-2-ethylhexyl phthalate was the main analyte found in these samples.  相似文献   

19.
Potentiometric FIA titrations were performed to determine enzyme activities of lipase type B from Candida antarctica, CAL-B. Two substrates, triacetin and tributyrin were hydrolyzed in phosphate buffer solutions, and the concentration change of the base component of the buffer was titrated in a carrier solution containing hydrochloric acid and potassium chloride. The system was calibrated with butyric acid and acetic acid, respectively. FIA titration peaks were evaluated with respect to peak height and peak area. Butyric acid and acetic acid could be titrated in the buffer solution from 3 × 10−3 mol L−1 to 0.1 mol L−1. The detection limit of enzyme activity was determined to be 0.07 U mL−1 (15 min reaction time) and the minimum activity was calculated to be 0.035 units corresponding to 35 nmol min−1. The specific activities of lipase B for the hydrolysis of tributyrin and triacetin were determined as 16 ± 2 U mg−1 and 2 ± 0.2 U mg−1 (per mg commercial lipase preparation), respectively.  相似文献   

20.
Wei Zhao  Xia Qin  Zixia Zhao  Lili Chen  Yuxin Fang 《Talanta》2009,80(2):1029-943
A novel strategy to fabricate hydrogen peroxide (H2O2) sensor was developed based on multi-wall carbon nanotube/silver nanoparticle nanohybrids (MWCNT/Ag nanohybrids) modified gold electrode. The process to synthesize MWCNT/Ag nanohybrids was facile and efficient. In the presence of carboxyl groups functionalized multi-wall carbon nanotubes (MWCNTs), silver nanoparticles (Ag NPs) were in situ generated from AgNO3 aqueous solution and readily attached to the MWCNTs convex surfaces at room temperature, without any additional reducing reagent or irradiation treatment. The formation of MWCNT/Ag nanohybrids product was observed by transmission electron microscope (TEM), and the electrochemical properties of MWCNT/Ag nanohybrids modified gold electrode were characterized by electrochemical measurements. The results showed that this sensor had a favorable catalytic ability for the reduction of H2O2. The resulted sensor could detect H2O2 in a linear range of 0.05-17 mM with a detection limit of 5 × 10−7 M at a signal-to-noise ratio of 3. The sensitivity was calculated as 1.42 μA/mM at a potential of −0.2 V. Additionally, it exhibited good reproducibility, long-term stability and negligible interference of ascorbic acid (AA), uric acid (UA), and acetaminophen (AP).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号