首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 687 毫秒
1.
The use of air bubbles as a heat transfer improvement technique for heat exchangers has been proposed by some researchers. The vertical motion of tiny bubbles because of density difference with liquid provides extra vibration, eddies, turbulences, and consequently further heat transfer rate. The variety of affected parameters, such as injection method, air mass flow rate, bubbles size, number of perforations that forms bubbles, etc., has added to the complexity of this phenomena so that any change in the said parameters significantly influences the thermal-exergetic behavior of the heat exchanger. The quality and quantity of the impact of bubbles on the thermal performance of heat exchangers are different for any type of them. Moreover, each type of heat exchanger requires a specific injection method depending on the heat exchanger structure. In the present research, an injection way is proposed for vertical double-tube heat exchangers, and the effect of bubbles on thermal-exergetic characteristics is experimentally studied and discussed, which have not been performed before. Nondimensional exergy destruction, number of heat transfer units, and effectiveness are the main evaluated parameters in the present paper. Results showed a significant thermal improvement of the heat exchanger under the bubble injection.  相似文献   

2.
随着纳米流体用于换热器的强化换热,纳米流体热管换热器的研究逐步扩展到各个领域,从航天到化工,从电子到能源。纳米流体热管由于表面温度低,较高的传热系数和较小的热阻,受到了广泛的关注。文中总结了纳米流体热管国内外的最新研究进展。  相似文献   

3.
 对用于固体激光介质冷却的组合式中间换热器的流动与传热特性进行了实验研究。实验研究结果表明:努塞尔数随雷诺数的增加而增加,总热阻随微通道侧蒸馏水流量的增加而减小,总换热量随微通道侧蒸馏水流量的增加而增加,且换热器的传热系数可以达到1.5×104 W/(m2·K),总热阻小于0.3 K/W,能较好地解决当前固体激光介质冷却系统中间换热器所存在的问题。  相似文献   

4.
介绍了一种适用于小流量大温升的新型盘状螺旋管换热器,具有结构简单、质轻,体积小的特点;利用相关的实验研究,获得其换热性能和流动阻力特性。实验结果表明,其在小流量下仍具有较高的传热系数,适合于做热泵热水器的水冷换热器。  相似文献   

5.
相变乳状液在蛇形管中的流动和传热特性   总被引:10,自引:1,他引:9  
用正十四烷、复合表面活化剂和水制成O/W型相变乳状液作为相变蓄冷及传热介质,对其作为非牛顿流体和固液两相流的流动和传热特点进行了分析,通过测试得出不同浓度乳状液在蛇形管道中的对流换热Nυ数和摩擦系数,并给出了换热和阻力的无量纲关联式。指出了对这类特殊相变蓄冷材料作进一步研究的方向。  相似文献   

6.
升膜蒸发是在换热器表面形成一层薄液膜,薄膜蒸发能够强化换热。文中研究采用光滑铜板的板式升膜蒸发器,以去离子水作为介质,在不同进水流量、不同加热量(热流密度)下,测定换热器某些点的局部换热系数,计算出总的换热系数,研究影响板式换热器升膜蒸发的因素和变化趋势。  相似文献   

7.
C. Zhang  Y. Han  Y. Zhu  X. Peng 《实验传热》2017,30(2):162-177
There has been increased attention on various types of plate heat exchangers because of their high efficiency and compactness. This article presents an investigation of heat transfer and fluid flow performance of a novel plate heat exchanger based on numeric studies and experimental tests. Parameters of the novel plate heat exchanger are analyzed and discussed. The thermo-hydraulic transfer performance of different plate heat exchangers is comprehensively analyzed using the exergy and entransy principle. The results indicate that the novel plate heat exchanger has better thermo-hydraulic transfer performance than the smooth plate heat exchanger. The result of this study provides a paradigm for the optimal design of plate heat exchangers.  相似文献   

8.
采用由SRK方程计算得出的混合工质物性参数,将具有相变两相流体物性分三部分处理,得出混合工质分段物性数据拟合曲线,并输入FLUENT软件的材料物性数据文件中,作为数值模拟物性参数数据。在上述物性数据处理的基础上,对混合工质天然气液化装置中换热器采用分段方式进行稳态数值模拟研究,得到沿长度方向一定温度下传热系数、压力梯度的变化曲线。通过与MUSE软件数据比较,计算结果有一定合理性,所得结论为有相变换热的混合工质低温板翅式换热器的设计和优化提供一定参考。  相似文献   

9.
弹性管束汽-水换热器强化传热试验研究   总被引:2,自引:0,他引:2  
本文设计了一种新的传热元件-弹性管束,它对管内外流体流动具有良好的振动响应特性。利用传热表面振动提高管外对流换热系数的同时,利用振动变形减少积垢,降低污垢热阻,实现了复合强化传热。在汽水换热条件下,对流作诱导振动强化传热规律进行了试验研究,得到了管外对流换热的准则方程式。  相似文献   

10.
The article presents the results of experimental investigation of boiling heat transfer of refrigerant R-21 in upward flow in a vertical plate-fin heat exchanger with transverse size of the channels that is smaller than the capillary constant. The heat transfer coefficients obtained in ranges of small mass velocities and low heat fluxes, which are typical of the industry, have been poorly studied yet. The characteristic patterns of the upward liquid-vapor flow in the heat exchanger channels and the regions of their existence are detected. The obtained data show a weak dependence of heat transfer coefficient on equilibrium vapor quality, mass flow rate, and heat flux density and do not correspond to calculations by the known heat transfer models. A possible reason for this behavior is a decisive influence of evaporation of thin liquid films on the heat transfer at low heat flux.  相似文献   

11.
This paper presents an experimental study of waste heat recovery shell-and-tube heat exchangers. The exchanger heat duty, overall heat transfer coefficient, effectiveness and tubeside friction factor are investigated as functions of the tube surface geometry (plain or dimpled), the flow type (counter or parallel), the tube Reynolds number and the shellside heat capacity rate. Water and the exhaust gases of a Diesel engine are passed inside the tube and the shell, respectively.The heat transfer characteristics increase with an increase in tube Reynolds number and the shellside heat capacity rate, for all the flow types and the surface geometries examined. The counter-flow, shell-and-dimpled-tube heat exchanger, compared with that exchanger having a plain tube, increases the heat duty and the overall heat transfer coefficient by 80%, and the heat exchanger -effectiveness increases by 35%. For the parallel-flow, shell-and-dimpled-tube heat exchanger, the heat duty, the overall heat transfer coefficient and the effectiveness increase by 30, 55, and 25%, respectively. At the same time the dimpled tube increases the tubeside friction factor by 600% over that of the plain tube. The rate of waste heat recovered from the exhaust gases of the Diesel engine by the counter-flow, shell-and-dimpled-tube heat exchanger is equal to 10% of the maximum brake power of the engine running at 1500 rpm, and the tube Reynolds number equal to 8875.  相似文献   

12.
螺旋折流片换热器壳侧传热与流动的数值模拟   总被引:9,自引:1,他引:8  
提出了一种强化管壳式换热器壳侧传热的螺旋折流片式换热器新方案,该方案在部分管子上套上螺旋折流片,不仅强化传热,而且对相邻管子形成支撑;利用FLUENT流体计算软件对同心套管螺旋折流片式换热段的壳侧流场、温度场进行了数值模拟,并讨论了螺旋角对其强化传热和阻力性能的影响。结果显示螺旋折流片诱导的涡旋流动对于减薄边界层,促进近壁流体与主流区流体的动量和质量交换进而强化传热有明显的作用,传热系数可比光管提高约40%-100%,但其流动阻力也将增大。  相似文献   

13.
马龙信  路昆 《低温与超导》2021,49(1):96-101
基于空气源热泵在低温寒冷地区运行中遇到的结霜问题,对不同风速工况下,结霜过程中设备性能的变化进行分析,以换热量、换热系数为指标对不同翅型换热器的换热特性进行研究.实验结果显示:换热器结霜过程中,换热过程主要分为初始增加段、换热平稳段、缓慢衰减段、后期平稳等四段,结晶体在增加空气湍流度强化换热的同时,也增加了换热热阻使换...  相似文献   

14.
An experimental energy storage system has been designed using a new type flat micro heat pipe heat exchanger that incorporates a moderate-temperature phase change material paraffin with a melting point of 58°C. The basic structure, working principles, and design concept are discussed. The heat transfer process during the charging and discharging of the heat exchanger under various operating conditions has been experimentally investigated. Results show that the performance of the new type flat micro heat pipe was steady and efficient during charging and discharging. The average thermal storage power and absorption efficiency have been determined to be approximately 537 W and 92.5%, respectively.  相似文献   

15.
热漏对换热器(火积)耗散最小化的影响   总被引:2,自引:0,他引:2       下载免费PDF全文
夏少军  陈林根  戈延林  孙丰瑞 《物理学报》2014,63(2):20505-020505
建立了存在热漏的换热器的传热过程模型.假定热流体与冷流体间的传热以及冷流体与外界环境间的热漏均服从牛顿传热定律,在冷流体净传热量一定的条件下,应用最优控制理论导出了换热过程(火积)耗散最小时热流体温度和冷流体温度的最优构型,并将最优路径分别与热流体温度一定和热流率一定的传统传热策略进行了比较.研究结果对于实际换热器的优化设计和最优运行具有一定的理论指导意义.  相似文献   

16.
Forced convection heat transfer from a helically coiled heat exchanger embedded in a packed bed of spherical glass particles was investigated experimentally. With dry air at ambient pressure and temperature as a flowing fluid, the effect of particle size, helically coiled heat exchanger diameter, and position was studied for a wide range of Reynolds numbers. It was found that the particle diameter, the helically coiled heat exchanger diameter and position, and the air velocity are of great influence on the convective heat transfer between the helically coiled heat exchanger and air. Results indicated that the heat transfer coefficient increased with increasing the air velocity, increasing helically coiled heat exchanger diameter, and decreasing the particle size. The highest heat transfer coefficients were obtained with the packed-bed particle size of 16 mm and heat exchanger coil diameter of 9.525 mm (1/4 inch) at a Reynolds number range of 1,536 to 4,134 for all used coil positions in the conducted tests. A dimensionless correlation was proposed for Nusselt number as a function of Reynolds number, particle size, coil size, and coil position.  相似文献   

17.
波纹板式空冷器阻力与传热特性实验研究   总被引:5,自引:0,他引:5  
在可改变风量和热水流量的实验条件下,对波纹板式空冷器的阻力与传热特性进行实验研究。得到了空气侧的阻力降关联式以及两侧的对流换热系数关联式,其适用于热水雷诺数在2000-8000之间、空气雷诺数在2000-10000之间。在相同工况下,比较了波纹板式、光管式和翅片管式空冷器的性能指标,结果表明:迎面风速在2.45-4.1 m/s之间,波纹板式空冷器传热系数达到100-160 W/m2/℃;约比光管式提高70%,但只有以管束外表面为基准的翅片管式传热系数的六分之一;板式空冷器单位体积换热量约是翅片管式空冷器的1.5倍,是光管式的15倍;板式空冷器单位功耗换热量约是光管式空冷器的5.5倍,而翅片管式空冷器与光管式空冷器则相差不大。  相似文献   

18.
An experimental investigation has been carried out to study the enhancement in heat transfer coefficient by inserting coiled wire around the outer surface of the inner tube of the double-pipe heat exchanger. Insulated wires, with a circular cross-section of 2 mm diameter, forming a coil of different pitches (p = 6, 12, and 20 mm), were used as turbulators. The investigation is performed for turbulent water flow in a double-pipe heat exchanger with cold water in the annulus space for both parallel and counter flows. The experiments were performed for Reynolds numbers ranging from 4,000 to 14,000. The experimental results reveal that the use of coiled circular wires leads to a considerable increase in heat transfer coefficients compared with a smooth wall tube for both parallel and counter water flows. The mean Nusselt number increases with Reynolds number and pitch. The convective heat transfer coefficient for a turbulent water flow increases for all coiled wire pitches, with the highest enhancement of about 450% for counter flow and 400% for the parallel flow. New correlations for mean relative Nusselt numbers at different coiled wire pitches are provided.  相似文献   

19.
伴随有水蒸气凝结的烟气对流换热的实验研究   总被引:13,自引:0,他引:13  
本文通过实验研究了冷凝式燃气热水器中烟气伴随有水蒸气凝结的受迫对流换热过程。着重介绍实验系统、测试方法和对塔板式换热器和肋片板式换热器的实验研究结果。实验表明,有水蒸气凝结时的烟气对流换热系数远大于无凝结时的换热系数,可提高数倍。在冷凝式换热器中,塔板式换热器的换热系数大于肋片板式换热器。  相似文献   

20.
The two-phase heat transfer coefficients of R404A and R134a in a smooth tube of 7.49-mm inner diameter were experimentally investigated at low heat and mass flux conditions. The test section is a 10-m-long counter-flow horizontal double-tube heat exchanger with refrigerant flow inside the tube and hot fluid in the annulus. The heat transfer coefficients along the length of the test section were measured experimentally under varied heat flux conditions between 4 and 18 kW m?2 and mass flux ranging between 57 and 102 kg m?2 s?1 (2.5 to 4.5 g s?1) for saturation temperatures of ?10°C, ?5°C, and 0°C. The saturation temperatures correspond to pressures of 4.4, 5.2, and 6.1 bar for R404A and 2.0, 2.4, and 3.0 bar for R134a, respectively. The results showed that under the tested conditions, the contribution of the nucleate boiling mechanism is predominant in the heat transfer coefficient throughout the flow boiling process. The Kattan–Thome–Favrat flow pattern maps confirm the occurrence of stratified and stratified-wavy flow patterns for all of the tested conditions. The average heat transfer coefficient of R404A is estimated to be 26 to 30% higher than that of R134a for the same saturation temperature.  相似文献   