首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 984 毫秒
1.
《中国化学快报》2023,34(4):107725
Extensive application of nuclear energy has caused widespread environmental uranium contamination. New detection approaches without complicated sample pretreatment and precision instruments are in demand for on-site and in-time determination of uranyl ions in environmental monitoring, especially in an emergency situation. In this work, a simple and effective fluorescent sensor (Z)-N'-hydroxy-4-(1,2,2-triphenylvinyl)benzimidamide (TPE-A) with aggregation-induced emission (AIE) character was established and studied. It could realize to detect UO22+ via quenching the fluorescence of its aggregation-induced emission, with good selectivity and sensitivity. Such strategy shows a wide linear range from 5.0 × 10?8 mol/L to 4.5 × 10?7 mol/L (R2 = 0.9988) with exceptional sensitivity reaching 4.7 × 10?9 mol/L, which is far below the limit for uranium in drinking water (30 μg/L, ca. 1.1 × 10?7 mol/L) stipulated by the WHO. A response time less than four minutes make it rapid for uranyl ion measurement. It was applied for detection of uranyl ion in spiked river water samples with recoveries in the range of 98.7%-104.0%, comparable to those obtained by ICP-MS. With the advantages of portable apparatus, rapid detection process and high sensitivity, TPE-A can serve as a promising fluorescent sensor for the detection of UO22+ in environmental water samples.  相似文献   

2.
A novel analytical approach for quantitative measurement of butylated hydroxyanisole (BHA) is dis‐ cussed in this paper. Such a method depends on the inhibitory effect of BHA on a Briggs‐Rauscher (B‐R) oscillating reaction. Unlike the classical B‐R system which involves Mn2+ as the catalyst, such a B‐R sys‐ tem is catalyzed by a macrocyclic nickel (II) complex [NiL](ClO4)2, where L in the complex is an unsatu‐ rated ligand 5,7,7,12,14,14‐hexemethyl‐1,4,8,11‐tetraazacyclotetradeca‐4,11‐diene. By perturbation of BHA on the system, the oscillation was inhibited in the presence trace amounts of BHA and the inhibition time was found to be proportional to the concentration of BHA over the range 1.00×10?7–1.20×10?4 mol/L. Two calibration curves were obtained: the first linear regression is over the range of 1.00×10?7–2.00×10?6 mol/L, and the second linear regression is over the range between 2.00×10?6 and 1.20×10?4 mol/L, with a lowest limit of detection of 4.00×10?8 mol/L. UV spectra measurements were employed to clarify the possible perturbation mechanism caused by BHA on the B‐R oscillating reaction.  相似文献   

3.
《Analytical letters》2012,45(15):2673-2682
Abstract

A new heteronuclear complex, rare earth (III)-copper (II)-m-trifluomethyl chlorophosphonazo (CPA-mCF3) system for determining trace rare earth ions is presented. In a medium of 0.02mol/L NH4Cl,1. 0×10?3mol/L Cu(II),1.0×10?5 mol/L CPA-mCF3, a very sensitive polarographic adsorptive wave is observed by using a single sweep oscillopolarograph at about –0.83V (vs. Ag/AgCl). The linear relationship between the peak current and the concentration of rare earth exists from 6. 0×10?9 to 1. 0×10?6 mol/L. The detection limit of rare earth is down to 2. 0×10?9 mol/L for Tm3+. This method has been applied to determine trace RE in several samples of Chinese tea. The results are satisfactory. The composition of the complex is detected as RE (II): Cu (II): CPA-mCF3 = 1: 1: 2.  相似文献   

4.
Introduction  Ionchromatography (IC)hasbeenrecognizedasausefulmethodfortheseparationofinorganicanionsandcationssinceitsintroductionbySmalletal .in 1975 .1AsignificanttrendinthedevelopmentofICmethodissearchforsensitiveanduniversaldetectionmethods .Themaindet…  相似文献   

5.
A novel Cr(III) ion‐selective electrode is constructed by incorporating a new aryl amide bifunctional bridging ligand, 2,2′‐bis{[(2″‐benzylaminoformyl)phenxoyl]methyl}‐diethylether (BBPMD) as a neutral carrier into the PVC matrix. The proposed electrode, with optimum membrane composition, exhibits an excellent near‐Nernstian response for Cr3+ ion ranging from 2.8 × 10?6 to 1.0 × 10?1 mol/L with a detection limit of 8.6 × 10?7 mol/L and a slope of 19.5 ± 0.2 mV/dec in pH 3.0 nitrate buffer solution at 25 °C. It has an appropriate response time, suitable reproducibility, and good selectivity towards Cr3+ ion. The operational pH range of the proposed electrode is 2.5–6.5. The response mechanism was discussed in view of UV‐vis spectroscopy and the A. C. impedance technique. The excellent analytical features of the proposed electrode could lead to its successful application as an indicator electrode in potentiometric titration of Cr3+ ion and in the direct determination of Cr3+ ion in tea leaves and coffee samples.  相似文献   

6.
《Analytical letters》2012,45(4):626-636
A new chemiluminescence system of Tb3+/K2S2O8 was developed for the determination of albumin. Some experimental conditions were examined and optimized. The linear ranges of the calibration curves are 5.0 × 10?9–5.0 × 10?6 mol/L for bovine serum albumin, 5.0 × 10?8–1.0 × 10?5 mol/L for human serum albumin and 2.5 × 10?7–1.0 × 10?5 mol/L for ovalbumin, and the corresponding detection limits are 1.9 × 10?9 mol/L, 1.5 × 10?8 mol/L, and 1.5 × 10?7 mol/L, respectively. The method was applied to the determination of albumin in human serum samples, and the results were in agreement with those obtained by the bromcresol green method. The relative errors for the analytical results were from ?2.0% to 4.3%.  相似文献   

7.
This work presents the analytical method development for iron and copper determination in ethanol fuel. This method was developed using stripping voltammetry with a glassy carbon electrode modified with Nafion/Carbon‐nanotubes. With linear sweep stripping voltammetry was achieved a limit of detection of 7.1×10?7 mol L?1 for Fe3+ and 5.1×10?8 mol L?1 for Cu2+. The amperometric sensitivities were 2.0×106 µA mol?1 L for Fe3+ and 2.8×107 µA mol?1 L for Cu2+. The recovery study showed that the method has good accuracy and repeatability, with recovery of 108 and 103 % for Fe3+ and Cu2+ respectively.  相似文献   

8.
Based on single‐walled carbon nanotubes (SWCNTs) modified glassy carbon electrode (GCE/SWCNTs), a novel method was presented for the determination of L ‐tyrosine. The GCE/SWCNTs exhibited remarkable catalytic and enhanced effects on the oxidation of L ‐tyrosine. In 0.10 mol/L citric acid‐sodium citrate buffer solution, the oxidation potential of L ‐tyrosine shifted negatively from +1.23 V at bare GCE to +0.76 V at GCE/SWCNTs. Under the optimized experimental conditions, the linear range of the modified electrode to the concentration of L ‐tyrosine was 5.0×10?6–2.0×10?5 mol/L (R1=0.9952) and 2.7×10?5–2.6×10?4 mol/L (R2=0.9998) with a detection limit of 9.3×10?8 mol/L. The kinetic parameters such as α (charge transfer coefficient) and D (diffusion coefficient) were evaluated to be 0.66, 9.82×10?5 cm2 s?1, respectively. And the electrochemical mechanism of L ‐tyrosine was also discussed.  相似文献   

9.
In this paper, an electrochemical aptamer sensor was proposed for the highly sensitive detection of mercury ion (Hg2+). Carbon nanofiber (CNF) was prepared by electrospinning and high‐temperature carbonization, which was used for the loading of platinum nanoparticles (PtNPs) by the hydrothermal method. The Pt@CNF nanocomposite was modified on the surface of carbon ionic liquid electrode (CILE) to obtain Pt@CNF/CILE, which was further decorated by gold nanoparticles (AuNPs) through electrodeposition to get Au/Pt@CNF/CILE. Self‐assembling of the thiol‐based aptamer was further realized by the formation of Au‐S bond to get an electrochemical aptamer sensor (Aptamer/Au/Pt@CNF/CILE). Due to the specific binding of aptamer probe to Hg2+ with the formation of T‐Hg2+‐T structure, a highly sensitive quantitative detection of Hg2+ could be achieved by recording the changes of current signal after reacting with Hg2+ within the concentration range from 1.0 × 10?15 mol/L to 1.0 × 10?6 mol/L and the detection limit of 3.33 × 10?16 mol/L (3σ). Real water samples were successfully analyzed by this method.  相似文献   

10.
杜会枝  杨频 《中国化学》2006,24(3):345-349
Using the whole cell patch clamp technique, the effect of Cu^2+on transient outward K^+current (/to) and delayed rectifier K^+ current (Idr) was studied in acutely isolated rat hippocampal neurons.Ito and Idr were increased when the concentration of Cu^2+ was lower than 2 × 10^-5 and 10^-5 tool/L, respectively, and increased ratio was decreased with increasing Cu^2+concentration in the bath solutions. When the concentration continued to increase to 5× 10^-5 and 2 × 10^- 5 mol/L, the currents were hardly changed, while the concentration was more than 10^-4 and 5 × 10^-5 mol/L, the currents were inhibited remarkably. Cu^2+ (10^-5 mol/L) did not affect the activation and inactivation process of Ito. The activation curve of Idr was shifted toward positive potential, but 10^-5 mol/L Cu^2+did not affect slope factor. According to these results, it was considered that Cu^2+at low concentration in the bath solution could promote Ito and Idr while at high concentration could inhibit them, and change of amplitude was different with different membrane voltage. Conclusion was drawn: Cu^2+may be involved in the pathophysiologic mechanism of diseases with neuropathological components.  相似文献   

11.
刘佩芳  文利柏 《中国化学》1998,16(3):234-242
The mass transport and charge transfer kinetics of ozone reduction at Nafion coated Au electrodes were studied in 0.5 mol/L H2SO4 and highly resistive solutions such as distilled water and tap water. The diffusion coefficient and partition coefficient of ozone in Nafion coating are 1.78×10-6 cm2·s-1 and 2.75 at 25℃ (based on dry state thickness), respectively. The heterogeneous rate constants and Tafel slopes for ozone reduction at bare Au are 4.1×10-6 cm·s-1, 1.0×10-6 cm·s-1 and 181 mV, 207 mV in 0.5 mol/L H2SO4 and distilled water respectively and the corresponding values for Nafion coated Au are 5.5×10-6 cm·s-1, 1.1×10-6 cm·s-1 and 182 mV, 168 mV respectively. The Au microelectrode with 3 μm Nafion coating shows good linearity over the range 0-10 mmol/L ozone in distilled water with sensitivity 61 μA·ppm-1 ·cm-2, detection limit 10 ppb and 95% response time below 5 s at 25℃. The temperature coefficient in range of 11-30℃ is 1.3%.  相似文献   

12.
A novel ion implantation sensor (DNA/COOH/ITO) based on DNA immobilization in COOH/ITO probe was manufactured for the first time. The surface morphologies of the electrodes were characterized by X‐ray photoelectron spectroscopy (XPS), field‐emission‐scanning electron microscopy (FSEM) and electrochemical methods. In a 0.5 mol/L PBS solution, a sensitive oxidation peak of DNA on the COOH/ITO electrode was obtained by voltammetry. The electrochemical behavior of DNA was studied. And the oxidative peak potential of DNA was +0.400 V (vs. Ag/AgCl). Its peak current was proportional to the concentration of DNA over the range of 1.0×10?8?1.0×10?6 mol/L with a detection limit of 5.0×10?9 mol/L (about 0.5 ng/mL). This sensor was applied to the direct detection of DNA samples.  相似文献   

13.
《Analytical letters》2012,45(9):1637-1646
Abstract

A poly(vinyl chloride) (PVC) membrane calcium-sensitive electrode based on a new type of synthetic carrier 1,7-di[2-(1-phenylazo)naphtyl]-1,4,7-trioxaheptan is introduced. This electrode exhibited Nernstian response over the concentration range 1.0×10?1 - 3.0×10?8 mol/L Ca2+ with a slope of 28.8 mV/pCa in calcium ion buffer solutions. The detection limit for calcium ion was 1.0X10?8 mol/L. The response time varied from 10 to 30 seconds. The working pH range for the electrode was 3.5 - 12.3 when the concentration of Ca2+ was 10?3 mol/L. The lifetime of the electrode was proved to exceed 8 months. It was applied successfully in the determination of calcium ion in river water, mineral water and cosmetic. A method for the determination of total calcium in urine was developed.  相似文献   

14.
《Analytical letters》2012,45(15):3239-3252
ABSTRACT

Potential dependent inhibition and enhancement effects of gallic acid on the electrochemiluminescence (ECL) of luminol in alkaline solutions were found. On the basis of the enhancement effect, a flow injection method was developed for the determination of gallic acid. The method was simple, convenient and sensitive. A detection limit of 1.8×10?8 mol/L, linear range of 3.0×10?8 - 1.0×10?4 mol/L, relative standard deviation of 1.0% for eleven measurements of 5.0×10?6 mol/L of gallic acid was found. This method was successfully applied to determine the content of gallic acid in Chinese gall (moshizi).  相似文献   

15.
Three types of ion‐selective electrodes: PVC membrane, modified carbon paste (CPE), and coated graphite electrodes (CGE) have been constructed for determining paroxetine hydrochloride (Prx). The electrodes are based on the ion pair of paroxetine with sodium tetraphenylborate (NaTPB) using dibutyl phthalate as plasticizing solvent. Fast, stable and potentiometric response was obtained over the concentration range of 1.1×10?5–1×10?2 mol L?1 with low detection limit of 6.9×10?6 mol L?1 and slope of a 56.7±0.3mV decade?1 for PVC membrane electrode, the concentration range of 2×10?5–1×10?2 mol L?1 with low detection limit of 1.2×10?5 mol L?1 and slope of a 57.7±0.6 mV decade?1 for CPE, and the concentration range of 2×10?5–1×10?2 mol L?1 with low detection limit of 8.9×10?6 mol L?1 and slope of a 56.1±0.1 mV decade?1 for CGE. The proposed electrodes display good selectivity for paroxetine with respect to a number of common inorganic and organic species. The electrodes were successfully applied to the potentiometric determination of paroxetine hydrochloride in its pure state, its pharmaceutical preparation, human urine and plasma.  相似文献   

16.
The initiation reaction of the polymerization of α-methylstyrene by trityl tetrachloroferate and tritylhexachloroantimonate in 1,2-dichloroethane at 20°C was studied. The rate constants were 14 × 10?3 and 27 × 10?3 L mol?1s?1, respectively. The dissociation constants of tritylterachloroferate (Kd = 0.88 × 10?4M?1) and tritylhexachloroantimonate (Kd = 2.64 × 10?4M?1) was determined. The effect of electron acceptors and donors on the dissociation equilibrium and initiation rate was investigated. It was shown that in strongly dissociated ion pairs such as stable carbenium salts the electron donors and acceptors have no appreciable effect on the magnitude of the dissociation. The temperature dependence of the rate constants in the ?20–+20°C range yielded the following thermodynamic parameters for trityltetrachloroferate: Ei = 8.54 kcal/mol; A = 3.2 × 104 mol?1s?1; ΔH* = 8 kcal/mol; and S* = ?39.8 eu.  相似文献   

17.
The complexation of thiabendazole (TBZ) with the cucurbit[6]uril (Q[6]), cucurbit[7]uril (Q[7]) and symmetric tetramethyl-cucurbit[6]uril (TMeQ[6]) in aqueous solution has been investigated using UV–vis and fluorespectrometry. The experimental results show 1:1 host–guest inclusion complexes at pH 6.5 for all three macrocyclic hosts, and the corresponding formation constants by UV and fluorescence methods are (5.37?±?1.05)?×?104?L?mol?1 and (1.47?±?0.41)?×?104?L?mol?1 for the Q[6]-TBZ system (7.76?±?0.51)?×?104?L?mol?1 and (9.36?±?0.22)?×?104?L?mol?1 for the Q[7]-TBZ system (1.28?±?0.78)?×?104?L?mol?1 and (2.69?±?0.55)?×?104?L?mol?1 for the TMeQ[6]-TBZ system, respectively. Based on the enhancement of the fluorescence intensity of TBZ with the addition of Q[n]s in neutral media, a fluorespectrometry method for the determination of TBZ in aqueous solution in the presence of Q[n] was established. In the range of 6.0?×?10?8?mol?L?1–8.0?×?10?6?mol?L?1 a linear relationship was obtained between fluorescence intensity and TBZ concentration. The detection limit was found to be between 5.51 and 8.85?×?10?9?mol?L?1. The interference of coexisting ions was found to be slight. The proposed method has been successfully applied to the determination of TBZ in different aqueous solutions with satisfactory recoveries of 92–103%. The method seems to be suitable for environmental water analysis.  相似文献   

18.
The interaction between mercuric ion and apoCopC in the absence or presence of cupric ion was investigated through difference UV spectra in Hepes buffer (10 mmol·L^-1) at pH 7.4. The results suggest that mercuric ion can bind to C- and N-terminal binding sites of apoCopC, and the conditional binding constants were calculated to be kN=(6.79± 1.12)× 10^6 mol^-1·L and kc=(3.06±0.05)× 10^5 mol^-1·L. Using urea as a chemical agent, the conformational stabilities of apoCopC and HgN^2+ -CopC-Hgc^2+ were monitored by fluorescence spectrum in Hepes buffer (50 mmol·L^-1) at pH 7.4. The free energy of stabilization is (14.69±0.85) and (16.66±0.55) kJ.mol^-1, respectively. HgN^2+ -CopC-Hgc^2+ is more stable than apoCopC.  相似文献   

19.
张洪林  于秀芳  聂毅  刘晓静  张刚 《中国化学》2003,21(11):1466-1469
IntroductionMostcomplicatedreactionshappenedinlivingcrea tures ,amongthemenzymecatalyzedreactionisanimpor tantclass .Itissignificantinboththeoryandpracticetoinvestigateenzymecatalyzedreaction .Therearemanyex perimentalmethodssuchasspectrophotometry ,titrimetry ,isotopemethod ,microcalorimetryandsoon ,inwhichmi crocalorimetryisanewoneduetoitshighsensitivityandaccuracy .Wecanstudythewholeprocessoftheheatef fectusingamicrocalorimeter .Sincetheabsorptionorpro ductionofheatisanintrinsicpropertyofe…  相似文献   

20.
A new voltammetric sensor, Langmuir–Blodgett (LB) film of a p‐tert‐butylcalix[4]arene derivative modified glassy carbon electrode, was designed and successfully used in simultaneous determination of Tl+ and Pb2+ by square‐wave anodic stripping voltammetry. Under the optimum experimental conditions, this newly developed sensor reveal good linear response for Tl+ and Pb2+ in the concentration range of 3×10?8–4×10?6 mol L?1 and 2×10?7–2×10?5 mol L?1 respectively. The detect limits are 2×10?8 mol L?1 for Tl+ and 8×10?8 mol L?1 for Pb2+. Using proposed method, Tl+ and Pb2+ in environment samples were determined with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号