首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
建立了同时测定饮用水源水中24种挥发性有机物(VOCs)的顶空固相微萃取-气相色谱-质谱法.用75 μm CarboxenTM-Polydimethylsiloxane(CAR-PDMS)固相微萃取柱顶空萃取水样中的VOCs,VOCs用气相色谱-质谱联用仪检测,采用内标法定量.对萃取柱涂层、样品盐度、萃取温度和萃取时间等样品前处理条件进行了优化,VOCs的检出限在0.03~0.31 μg/L之间,线性相关系数r>0.996(二氯甲烷和三氯甲烷除外).对饮用水源水实际水样0.50μg/L和1.00 μg/L两个加标浓度水平的回收率进行了测定,三氯甲烷回收率均值分别为104%和142%,其余VOCs回收率分别为90.0%~120%和88.0%~110%,除二氯甲烷和三氯甲烷外,其余VOCs测定结果的相对标准偏差均小于15.0%(n=6).该方法适用于饮用水源水中挥发性有机物的监测分析.  相似文献   

2.
An ultrasound-assisted emulsification-microextraction (USAEME) procedure was developed for the extraction of US EPA 16 polycyclic aromatic hydrocarbons (PAHs) in 10 mL of water samples, with subsequent determination by gas chromatography-mass spectrometry (GC-MS). After determination of the most suitable solvent and solvent volume, several other parameters (i.e., extraction time, centrifugation time and ionic strength of the sample) were optimized using a 23 factorial experimental design. Limits of detection ranged from 0.001 to 0.036 μg L−1. The developed procedure was applied to fortified distilled water with different fortification levels (0.5, 2 and 5 μg L−1). Recoveries were over 92% and relative standard deviations of the recoveries were below 8%. The efficiency of the USAEME was compared with traditional liquid-liquid extraction (LLE) and solid-phase extraction on real water samples (i.e., tap water, well water and surface (lake) water as well as domestic and industrial wastewaters). The USAEME showed comparable efficiencies especially with LLE. The developed USAEME was demonstrated to be robust, viable, simple, rapid and easy to use for the determination of PAHs in water samples by GC-MS.  相似文献   

3.
In this study, a microextraction method termed as ultrasound‐assisted emulsification–microextraction (USAEME) has been developed for the extraction of organophosphorus pesticides (OPPs) in water and orange juice samples. In the USAEME method, aliquots of 50 μL chlorobenzene used as extraction solvent was added to 10 mL water sample in a conical glass centrifugal tube. Factors influencing the USAEME extraction efficiency such as sonication time, extraction solvent, extraction volume and salt addition were evaluated. Under the optimum conditions, enrichment factors ranged from 241 to 311, LOD varied from 5.3 to 10.0 ng/L and linearity with a coefficient of estimation (r2) varied from 0.9991 to 0.9998 in the concentration level range of 0.05–2.5 μg/L for the extraction of OPPs in water samples. Finally, the proposed USAEME method was used for the extraction of OPPs from water and orange juice. The recoveries were in the range of 80.0–110.0%, and the repeatability of the method expressed as RSD (n=3) varied between 1.6 and 13%. The USAEME method has the advantage of being easy to operate, low consumption of organic solvent and high extraction efficiency.  相似文献   

4.
A method was developed for viable and rapid determination of seven polychlorinated biphenyls (PCBs) in water samples with vortex-assisted liquid-liquid microextraction (VALLME) using gas chromatography-mass spectrometry (GC-MS). At first, the most suitable extraction solvent and extraction solvent volume were determined. Later, the parameters affecting the extraction efficiency such as vortex extraction time, rotational speed of the vortex, and ionic strength of the sample were optimized by using a 2(3) factorial experimental design. The optimized extraction conditions for 5 mL water sample were as follows: extractant solvent 200 μL of chloroform; vortex extraction time of 2 min at 3000 rpm; centrifugation 5 min at 4000 rpm, and no ionic strength. Under the optimum condition, limits of detection (LOD) ranged from 0.36 to 0.73 ng/L. Mean recoveries of PCBs from fortified water samples are 96% for three different fortification levels and RSDs of the recoveries are below 5%. The developed procedure was successfully applied to the determination of PCBs in real water and wastewater samples such as tap, well, surface, bottled waters, and municipal, treated municipal, and industrial wastewaters. The performance of the proposed method was compared with traditional liquid-liquid extraction (LLE) of real water samples and the results show that efficiency of proposed method is comparable to the LLE. However, the proposed method offers several advantages, i.e. reducing sample requirement for measurement of target compounds, less solvent consumption, and reducing the costs associated with solvent purchase and waste disposal. It is also viable, rapid, and easy to use for the analyses of PCBs in water samples by using GC-MS.  相似文献   

5.
The simultaneous extraction of acidic and basic pollutants from water samples is an interesting and debatable work in sample preparation techniques. A novel and efficient method named ion pair based surfactant assisted microextraction (IP-SAME) was applied for extraction and preconcentration of five selected acidic and basic aromatic species as model compounds in water samples, followed by high performance liquid chromatography-ultraviolet detection. A mixture including 1 mL of ultra-pure water (containing ionic surfactant as emulsifier agent) and 60 μL 1-octanol (as extraction solvent) was rapidly injected using a syringe into a 10.0 mL water sample which formed an emulsified solution. IP-SAME mechanism can be interpreted by two types of molecular mass transfer into the organic solvent (partitioning and ion pairing for non-ionized and ionized compounds, respectively) during emulsification process. The effective parameters on the extraction efficiency such as the extraction solvent type and its volume, type of the surfactant and its concentration, sample pH and ionic strength of the sample were optimized. Under the optimum conditions (60 μL of 1-octanol; 1.5 mmol L(-1) cethyltrimethyl ammonium bromide (CTAB) as emulsifier agent and sample pH 10.0), the preconcentration factors (PFs), detection limits and linear dynamic ranges (LDRs) were obtained in the range of 87-348, 0.07-0.6 μg L(-1) and 0.1-200 μg L(-1) respectively. All of natural water samples were successfully analyzed by the proposed method.  相似文献   

6.
A novel method using sample preparation method, "ultrasound-assisted emulsification microextraction" (USAEME) with manual shaking, coupled with gas chromatography using and an electron capture detector (GC-ECD) was developed for the analysis of organochlorine pesticides (OCPs) in aqueous samples. The apparatus is simple and easy to operate. After manual shaking for 10s, ultrasound was used to accelerate emulsification of the organic solvent (1-decanol) in aqueous solution. Only 10 μL of the low-toxicity extraction solvent is used in this method; no dispersive solvent is required and the total extraction time is ~4 min. Manual shaking before ultrasound-assisted emulsification enhances the extraction efficiency by >100%. The effects of horizontal and vertical orientation as well as the location of the sample within the ultrasonic bath were studied. After centrifugation, we used an improved solvent collection system (ISCS) to reduce the amount of extraction solvent required. A 1 μL sample of the extract was injected into the GC column. Under optimum conditions, the linear range of the method is 5-2500 ngL(-1) for most of the OCPs, and the limit of detection of the method ranged from 0.6 to 2.9 ngL(-1).The relative recoveries ranged from 75 to 107% for sea water and from 70 to 99% for field fresh water. The method, which provides good enrichment factors, low LODs and minimization of the consumption of organic solvent, provides a rapid, simple and environment-friendly procedure for determining OCPs in aqueous samples.  相似文献   

7.
吴翠琴  雷金妹  李韵灵  王韵靓  陈迪云  龚剑 《色谱》2014,32(12):1362-1367
建立了一种基于离子液体的分散液液微萃取技术结合柱前荧光衍生高效液相色谱(IL-DLLME-HPLC-FL)对8种磺胺类药物进行检测的方法,并成功应用于实际环境水样的分析。实验考察了萃取参数对磺胺萃取效率的影响及衍生产物的稳定性。最佳实验条件:以40 μL [C6MIM]PF6]为萃取剂,0.1 mL丙酮为分散剂,对pH=4且不含NaCl的水溶液进行不超声的分散液液微萃取,并衍生化反应6 h。结果表明:在最佳实验条件下,该法在0.2~10 μg/L和10~500 μg/L两个浓度范围内线性良好,线性相关系数r ≥0.9989;检出限为0.08~0.5 μg/L (S/N=3)。对实验室自来水、湖水、珠江水、池塘水分别加标5、50、200 μg/L的回收率为87.2%~101.4%,相对标准偏差为3.7%~6.2%。该法环保、简便,可用于测定实际水样中磺胺类药物。  相似文献   

8.
Guo L  Lee HK 《Journal of chromatography. A》2011,1218(31):5040-5046
For the first time, the low-density solvent-based solvent demulsification dispersive liquid-liquid microextraction was developed for the fast, simple, and efficient determination of 16 priority polycyclic aromatic hydrocarbons (PAHs) in environmental samples followed by gas chromatography-mass spectrometric (GC-MS) analysis. In the extraction procedure, a mixture of extraction solvent (n-hexane) and dispersive solvent (acetone) was injected into the aqueous sample solution to form an emulsion. A demulsification solvent was then injected into the aqueous solution to break up the emulsion, which turned clear and was separated into two layers. The upper layer (n-hexane) was collected and analyzed by GC-MS. No centrifugation was required in this procedure. Significantly, the extraction needed only 2-3 min, faster than conventional DLLME or similar techniques. Another feature of the procedure was the use of a flexible and disposable polyethylene pipette as the extraction device, which permitted a solvent with a density lighter than water to be used as extraction solvent. This novel method expands the applicability of DLLME to a wider range of solvents. Furthermore, the method was simple and easy to use, and some additional steps usually required in conventional DLLME or similar techniques, such as the aforementioned centrifugation, ultrasonication or agitation of the sample solution, or refrigeration of the extraction solvent were not necessary. Important parameters affecting the extraction efficiency were investigated in detail. Under the optimized conditions, the proposed method provided a good linearity in the range of 0.05-50 μg/L, low limits of detection (3.7-39.1 ng/L), and good repeatability of the extractions (RSDs below 11%, n=5). The proposed method was successfully applied to the extraction of PAHs in rainwater samples, and was demonstrated to be fast, efficient, and convenient.  相似文献   

9.
建立了涂料中5种挥发性有机物(VOCs)的顶空气相色谱-质谱(HS/GC-MS)分析方法.对溶剂、平衡温度、平衡时间、GC-MS的分离检测等实验条件进行了优化.涂料样品经N,N-二甲基甲酰胺(DMF)-水(1 :1,体积比)溶解分散,经90 ℃、90 min静态顶空后,通过DB-VRX色谱柱分离和质谱检测,外标法定量....  相似文献   

10.
Zheng C  Zhao J  Bao P  Gao J  He J 《Journal of chromatography. A》2011,1218(25):3830-3836
A novel, simple and efficient dispersive liquid-liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) technique coupled with high-performance liquid chromatography with ultraviolet detection (HPLC-UV) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the determination of triclosan and its degradation product 2,4-dichlorophenol in real water samples. The extraction solvent used in this work is of low density, low volatility, low toxicity and proper melting point around room temperature. The extractant droplets can be collected easily by solidifying it at a lower temperature. Parameters that affect the extraction efficiency, including type and volume of extraction solvent and dispersive solvent, salt effect, pH and extraction time, were investigated and optimized in a 5 mL sample system by HPLC-UV. Under the optimum conditions (extraction solvent: 12 μL of 1-dodecanol; dispersive solvent: 300 of μL acetonitrile; sample pH: 6.0; extraction time: 1 min), the limits of detection (LODs) of the pretreatment method combined with LC-MS/MS were in the range of 0.002-0.02 μg L(-1) which are lower than or comparable with other reported approaches applied to the determination of the same compounds. Wide linearities, good precisions and satisfactory relative recoveries were also obtained. The proposed technique was successfully applied to determine triclosan and 2,4-dichlorophenol in real water samples.  相似文献   

11.
Ionic liquid-based dispersive liquid-liquid micro-extraction (IL-DLLME) was coupled with high-performance liquid chromatography-ultraviolet (HPLC-UV) for the determination of four phthalate esters, including butyl benzyl phthalate, di-n-butyl phthalate, dicyclohexyl phthalate and bis(2-ethylhexyl) phthalate in water samples. The mixture of ionic liquid (IL) and dispersive solvent was rapidly injected into 10 mL aqueous sample. Then, IL phase was separated by centrifugation and was determined by high-performance liquid chromatography-ultraviolet. The factors influencing the extraction efficiency, such as type and volume of IL, disperse solvent, extraction time, centrifuging time and ionic strength, were investigated and optimized. Under the optimized conditions, the extraction recoveries by the proposed ionic liquid-based dispersive liquid-liquid micro-extraction for the four phthalates ranged from 83.0 to 91.7%. The relative standard deviations were between 7.8 and 15%. The limits of quantification for four phthalates were between 10.6 and 28.5 μg/L. The proposed method was successfully applied for the analysis of PAEs in tap, lake and treated wastewater samples.  相似文献   

12.
For the first time, the low‐density solvent‐based vortex‐assisted surfactant‐enhanced emulsification liquid–liquid microextraction, followed by GC‐flame photometric detection has been developed for the determination of eight organophosphorus pesticides in aqueous samples. A small volume of organic extraction solvent (toluene) was dispersed into the aqueous samples by the assistance of surfactant and vortex agitator. The extraction was performed in a special disposable polyethylene pipette, allowing using the reagents with lower density than water as extraction solvents. The influence parameters were systemically investigated and optimized: toluene (30 μL) and Triton X‐100 (0.2 mmol/L) were used as the extraction solvent and the surfactant, respectively, and the extraction was performed for 1 min under room temperature without adding sodium chloride. Under the optimum conditions, the validation parameters such as the RSD (n = 6; 2.1–11.3%), LOD (0.005 and 0.05 μg/L), and linear range (0.1–50.0 μg/L with correlation coefficients (0.9958–0.9992) showed the method was satisfying. The proposed method has been successfully applied to the determination of the organophosphorus pesticides in real samples with recoveries between 82.8 and 100.2%.  相似文献   

13.
<正>Triacontyl modified silica gel as a sorbent coupled with gas chromatography-mass spectrometry(GC-MS) was developed to determine EPA prior 16 polycyclic aromatic hydrocarbons(PAHs) in water samples.Various parameters of solid-phase extraction such as organic modifier solvent,eluent,sample flow rate and volume were optimized.The developed method was found to yield a linear calibration curve in the concentration range of 0.05-8μg/L with respect to naphthalene,acenaphthylene,acenaphthene and 0.01-8μg/L for dibenz[a,h]anthracene and 0.05-14μg/L for fluorene,phenanthrene,anthracene and 0.01-14μg/L for the rest of analytes.Furthermore,the good accuracy and repeatability of the method made sure the requirements for achieving reliable analysis of PAHs in the environmental water samples,and the recoveries of optimal method were in the range of 80-120%except to higher volatility PAHs.C_(30)-bonded silica was proved to be an efficient sorbent for extraction of high molecular weight PAHs.  相似文献   

14.
Guo L  Lee HK 《Journal of chromatography. A》2011,1218(52):9321-9327
Micro-solid-phase extraction (μ-SPE) was developed for the determination of trace level of 16 United States Environmental Protection Agency priority polycyclic aromatic hydrocarbons (PAHs) in river water samples with gas chromatography-mass spectrometry (GC-MS). In the μ-SPE device, multiwalled carbon nanotubes was employed as sorbent and was packed inside an porous polypropylene membrane "envelope" whose edges were heat-sealed to secure the contents. The μ-SPE device was placed in a stirred sample solution to extract the analytes. The porous polypropylene membrane envelope in μ-SPE device acts as a filter to exclude potential interferences, such as eliminating or reducing the influence of particles that are bigger than the pore size. After extraction, analyte desorption was carried out with a suitable organic solvent under ultrasonication. Important extraction parameters were optimized in detail, including the selection and amount of sorbent materials, the extraction temperature and extraction time, desorption solvent and desorption time, amount of organic modifier, agitation speed and sample ionic strength. Under the developed extraction conditions, the proposed method provided good linearity in the range of 0.1-50 μg/L, low limits of detection (4.2-46.5 ng/L), and good repeatability of the extractions (relative standard deviations, <12%, n=5). The developed μ-SPE method was successfully applied to the extraction of PAHs in river water samples. The μ-SPE method was demonstrated to be a fast and efficient method for the determination of PAHs from environmental water samples.  相似文献   

15.
In this study, a method based on ultrasound-assisted emulsification-microextraction (USAEME) was optimised for the determination of Brett character responsible compounds (4-ethylguaiacol (EG), 4-ethylphenol (EP), 4-vinylguaiacol (VG) and 4-vinylphenol (VP)) in wines. For this purpose, once the extraction solvent had been selected, the influence on the extraction efficiency of ratio between extraction solvent and sample volumes, temperature, ionic strength and time was studied using experimental design methodology. The optimum conditions found for USAEME of 5mL of wine were 160μL of chlorobenzene at 60°C during 5min without salt addition. Then, the analytical performance of the optimised USAEME procedure was evaluated. For all the studied compounds, the proposed method showed correlation coefficients over 0.984. Satisfactory repeatability (below 10%) and inter-day repeatability (below 11%) were obtained at different concentration levels and the method achieved detection limits similar or even lower than previously reported for these compounds in wines. Moreover, the applicability of the method was evaluated by the analysis of real samples. To our knowledge, this is the first time that USAEME has been applied to the determination of Brett character responsible compounds in wine.  相似文献   

16.
An in-syringe ultrasound-assisted emulsification microextraction (USAEME) was developed for the extraction of organophosphorus pesticides (OPPs) from water samples. The OPPs subsequently analyzed gas chromatography (GC) using a microelectron capture detector (μECD). Ultrasound radiation was applied to accelerate the emulsification of μL-level low-density organic solvent in aqueous solutions to enhance the microextraction efficiency of OPPs in the sample preparation for GC-μECD. Parameters affecting the efficiency of USAEME, such as the extraction solvent, solvent volume, pH, salt-addition, and extraction time were thoroughly investigated. Based on experimental results, OPPs were extracted from a 5 mL aqueous sample by the addition of 20 μL toluene as the extraction solvent, followed by ultrasonication for 30 s, and then centrifugation for 3 min at 3200 rpm, offered the best extraction efficiency. Detections were linear in the concentration of 0.01–1 μg/L with detection limits between 1 ng/L and 2 ng/L for OPPs. Enrichment factors ranged from 330 to 699. Three spiked aqueous samples were analyzed, and recovery ranged from 90.1% to 104.7% for farm-field water, and 90.1% to 101.8% for industrial wastewater. The proposed method provides a simple, rapid, sensitive, inexpensive, and eco-friendly process for determining OPPs in water samples.  相似文献   

17.
We present a novel dispersive liquid–liquid microextraction method based on the solidification of deep eutectic solvent coupled with high‐performance liquid chromatography with a variable‐wavelength detection for the detection of five benzoylureas in real water samples. In this work, a green solvent consisting of 1‐octyl‐3‐methylimidazolium chloride and 1‐dodecanol was used as an extraction solvent, yielding the advantages of material stability, low density, and a suitable freezing point near room temperature. Parameters that significantly affect extraction efficiency were optimized by the one‐factor‐at‐a‐time approach. Under optimal conditions, the recoveries of five target compounds were obtained ranging from 87.39 to 98.05% with correlation coefficients ranging from 0.9994 to 0.9997 for pure water. The limits of detection were in the range of 0.09–0.16 μg/L. The enrichment factors were in the range of 171–188. Linearities were achieved in the range of 0.5–500 μg/L. The proposed method was successfully applied to determine benzoylureas in environmental water samples with a satisfactory recovery of approximately 81.38–97.67%.  相似文献   

18.
Dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry (GC-MS) was evaluated for the simultaneous determination of five chlorophenols and seven haloanisoles in wines and cork stoppers. Parameters, such as the nature and volume of the extracting and disperser solvents, extraction time, salt addition, centrifugation time and sample volume or mass, affecting the DLLME were carefully optimized to extract and preconcentrate chlorophenols, in the form of their acetylated derivatives, and haloanisoles. In this extraction method, 1mL of acetone (disperser solvent) containing 30μL of carbon tetrachloride (extraction solvent) was rapidly injected by a syringe into 5mL of sample solution containing 200μL of acetic anhydride (derivatizing reagent) and 0.5mL of phosphate buffer solution, thereby forming a cloudy solution. After extraction, phase separation was performed by centrifugation, and a volume of 4μL of the sedimented phase was analyzed by GC-MS. The wine samples were directly used for the DLLME extraction (red wines required a 1:1 dilution with water). For cork samples, the target analytes were first extracted with pentane, the solvent was evaporated and the residue reconstituted with acetone before DLLME. The use of an internal standard (2,4-dibromoanisole) notably improved the repeatability of the procedure. Under the optimized conditions, detection limits ranged from 0.004 to 0.108ngmL(-1) in wine samples (24-220pgg(-1) in corks), depending on the compound and the sample analyzed. The enrichment factors for haloanisoles were in the 380-700-fold range.  相似文献   

19.
A new method using gas chromatography-tandem mass spectrometry (GC-MS/MS) was developed for the determination of four benzotriazoles, i.e. benzotriazole (BT), 5-methylbenzotriazole (5-TTri), 5-chlorobenzotriazole (CBT), 5,6-dimethylbenzotriazole (XTri), and six UV filters, i.e. benzophenone-3 (BP-3), 3-(4-methylbenzylidene)camphor (4-MBC), octyl 4-methoxycinnamate (OMC), 2-(3-t-butyl-2-hydroxy-5-methylphenyl)-5-chloro benzotriazole (UV-326), 2-(2'-hydroxy-5'-octylphenyl)-benzotriazole (UV-329), and octocrylene (OC) in ground water, effluent and biosolid samples. Solid phase extraction (SPE) and pressurized liquid extraction (PLE) were applied as the preconcentration method for water samples (ground water and effluent) and biosolid samples, respectively. The optimized method allowed us to quantify all target compounds with the method detection limits ranging from 0.29 to 11.02 ng/L, 0.5 to 14.1 ng/L and 0.33 to 8.23 ng/g in tap water, effluent and biosolid samples, respectively. The recoveries of the target analytes in tap water, effluent and biosolid samples were 70-150%, 82-127% and 81-133%, respectively. The developed analytical method was applied in the determination of these target compounds in ground water, effluent and biosolid samples collected from Bolivar sewage treatment plants in South Australia. In effluent samples, the target compounds BT, 5-TTri, CBT, XTri and BP-3 tested were detected with the maximum concentration up to 2.2 μg/L for BT. In biosolid samples, eight out of ten compounds tested were found to be present at the concentrations ranging between 18.7 ng/g (5-TTri) and 250 ng/g (4-MBC).  相似文献   

20.
In this study, the organochlorine pesticides (OCPs) levels in lake and tap water samples were determined by a dispersive liquid-liquid microextraction method using a low-density organic solvent and an improved solvent collection system (DLLME-ISCS). This method used a very small volume of a solvent of low toxicity (11 μL of 1-nonanol and 400 μL of methanol) to extract OCPs from 10 mL water samples prior to the analysis by GC. After centrifugation in the dispersive liquid-liquid microextraction, there was a liquid organic drop floating between the water surface and the glass wall of the centrifuge tube. The liquid organic drop (with some water phase) was transferred into a microtube (3 mm×15 mm) with a syringe. The organic and aqueous phases were separated in the microtube immediately. Then, 1 μL of the organic solvent (which was in the upper portion of liquid in the microtube) was easily collected by a syringe and injected into the GC-ECD system for the analysis. Under optimum conditions, the linear range of this method was 5-5000 ng/L for most of the analytes. The correlation coefficient was higher than 0.997. Enrichment factors ranged from 1309 to 3629. The relative recoveries ranged from 73 to 119% for lake water samples. The LODs of the method ranged from 0.7 to 9.4 ng/L. The precision of the method ranged from 1.0 to 10.8% for lake water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号