首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Fluorescence spectroscopy and circular dichroism (CD) spectroscopy were used to investigate the interaction of coumarin-3-carboxylic acid with human serum albumin (HSA) and bovine serum albumin (BSA) under physiological conditions in a buffer solution of pH 7.4.   相似文献   

2.
A new amperometric titration method was developed for quantitative determination of ferrate(VI) (FeVIO4 2−) in the 7.06×10−5−5.73×10−3 M concentration range. Chromium(III) hydroxide solution was used as the titrant. The diffusion current (Id) had a linear relationship with the concentration of ferrate(VI) and slopes were dependent on the concentration of NaOH. The amperometric titration could detect a lower concentration of ferrate(VI) than could potentiometric and colorimetric titrations. The method was applied successfully to determine concentrations of ferrate(VI), generated electrochemically, in strong alkaline solutions.   相似文献   

3.
Lutetium has been determined by differential pulse anodic stripping voltammetry in an acidic solution containing Zn-EDTA. Lutetium (III) ions liberated zinc (II), which was preconcentrated on a hanging mercury drop electrode and stripped anodically, resulting in peak current linearly dependent on lutetium (III) concentration. Less than 0.4 ng mL−1 lutetium could be detected after a 2 min deposition.   相似文献   

4.
In the present study newly produced semiconductor ceramic nanopowder materials made of CdTe and Cd1−xZnxTe (CZT) are considered. Common features and differences in microstructures, phase transformations, grain growth and properties of the ceramic materials of the binary and ternary compositions are studied.   相似文献   

5.
Electrochemical oxidation of methylthiomethyleneisoquinolinium chloride (MTMIQ), the first alkylthiomethyl substituted ammonium salt, which is fully miscible with water has been investigated by voltammetric (SWV) method using glassy carbon electrode. On the electrode, MTMIQ undergoes oxidation at the potential near Ep = 0.07V (vs. Ag/AgCl/3 M KCl). The influence of the pH of buffers, amplitude, frequency, step potential on the received signal was studied. The best results were obtained with a citrate buffer at a pH of 5. The oxidation peak current used for MTMIQ voltammetric determination was in the range of 2–8×10−5 mol L−1, LOD = 3.7×10−6, LOQ = 1.2×10−5. The product of the oxidation was accumulated at the working electrode and was investigated by spectroscopic method. Mechanistic pathways of the oxidation have been proposed.   相似文献   

6.
Ionic liquids (IL) are gaining importance as green solvents. Imidazolium ionic liquid [bmim]+[Cl], an environmentally benign solvent, was found to promote the Diels-Alder reaction between anthrone and maleimides at room temperature with excellent yields. The ionic liquid played a dual role as solvent and catalyst.   相似文献   

7.
Preliminary results of development of a direct and fast method of determination of antimony in samples of tap water using GFAAS are presented. The found levels of antimony were lower than permitted for human consumption. A mixture of Pd and Mg(NO3)2 (concentrations in the injected solution: 8.6 μg mL−1 and 5.8 μg mL−1 respectively) was used as the chemical modifier. The pyrolysis and atomization temperatures were 1000 and 1700°C, respectively and the mean analytical recovery 98.2%.   相似文献   

8.
The influence of EDTA, carboxylic acids, amino-and hydroxocarboxylic acids, monosaccharides and humic substances on the generation of arsines in hydride generation atomic absorption spectrometry (HGAAS) was investigated. EDTA (0.02 mol L−1), ascorbic acid (0.02 mol L−1) and glucose or fructose (0.2 mol L−1) are useful additives for levelling sensitivities for As(III), monomethylarsonate (MMA) and dimethylarsinate (DMA). The presence of glycine, malonic, tartaric acids, BICIN and soil humin extracts leads to differences in analytical signal response between these arsenic species. An analytical application to the determination of the sum of As(III), monomethylarsonate (MMA) and dimethylarsinate (DMA) as well as the sum of toxicologically relevant hydride forming arsenic fraction As(III) + As(V) + MMA + DMA in EDTA soil/sediment extracts using continuous flow HGAAS was demonstrated. The limit of detection was 0.2 mg kg−1 As. Within-day and between-day precision were in the range 3–7% and 4–10%, respectively, for arsenic contents of 0.7–25 mg kg−1, with recoveries 95–103%.   相似文献   

9.
Selected β-diketones bearing unsaturated derivatives have been demonstrated to undergo homo-metathesis and cross-metathesis with selected olefins in the presence of Grubbs catalysts. The reactions led to respective homo- and cross-metathesis products mainly with good yields and selectivities.   相似文献   

10.
A simple flow-based method was developed for the simultaneous separation of certain transition metal ions (Co, Ni, Cu, Zn, Cd) from aqueous systems, which ions show ecotoxic effects when present at elevated concentrations. A silica-gel-bonded macrocycle system, commonly known as molecular recognition technology (MRT) gel, was used for solid phase extraction (SPE) of the target analytes. The collection behavior of the MRT-SPE system was studied based on pH. Fortified deionized water samples containing 250 μg L−1 of each of the elements were treated at the flow rate of 1 mL min−1. The collected analytes were then eluted by 3 M HNO3 and analyzed using inductively coupled plasma spectrometry. Detection limits of the proposed technique were in the range of 0.004–0.040 μg L−1 for the studied metal ions. The validity of this separation technique was checked with spiked ‘real’ water samples, which produced satisfactory recoveries of 96–102%. The non-destructive nature and highly selective ion-extraction capability of the SPE material are the most important aspects of the proposed method and they are the main focus of this paper.   相似文献   

11.
This article describes the simple hydrodehalogenation of halogenated anilines and their derivatives by the action of Raney aluminium-nickel alloy in aqueous alkaline solution at room temperature. The reaction course was monitored by means of 1H nuclear magnetic resonance (NMR) spectroscopy and GC-MS spectra.   相似文献   

12.
A hollow fibre liquid phase microextraction for gas chromatographic determination of some p-hydroxybenzoic acid esters has been developed. Chlorobenzene containing tetradecane as internal standard was used for the extraction. Optimized extraction was carried out at room temperature for 40 min in the presence of 0.4 g mL−1 NaCl in the sample solution. Calibration was linear up to 30 mg L−1. Correlation coefficients were 0.996–0.998. Enrichment factors were 21, 95 and 154, and detection limits were 0.20, 0.03 and 0.01 μg mL−1 for methylparaben, ethylparaben and propylparaben, respectively. Reproducibility was acceptable with relative standard deviations up to 11.7%. The technique was tested for water and urine analysis.   相似文献   

13.
A partial least squares (PLS-1) calibration model based on kinetic—spectrophotometric measurement, for the simultaneous determination of Cu(II), Ni(II) and Co(II) ions is described. The method was based on the difference in the rate of the reaction between Co(II), Ni(II) and Cu(II) ions with 1-(2-pyridylazo)2-naphthol in a pH 5.8 buffer solution and in micellar media at 25°C. The absorption kinetic profiles of the solutions were monitored by measuring the absorbance at 570 nm at 2 s intervals during the time range of 0–10 min after initiation of the reaction. The experimental calibration matrix for the partial least squares (PLS-1) model was designed with 30 samples. The cross-validation method was used for selecting the number of factors. The results showed that simultaneous determination could be performed in the range 0.1-2 μg mL−1 for each cation. The proposed method was successfully applied to the simultaneous determination of Cu(II), Ni(II) and Co(II) ions in water and in synthetic alloy samples.   相似文献   

14.
The optimal process of pre-treatment and activation of gold rotating disc electrode (AuRDE) before voltammetric determination of mercury is proposed. This treatment encompasses polishing of the electrode surface, electrochemical cycling, and activation. This procedure both increases determination sensitivity as well as improves determination reproducibility. The detection limit on the working electrode achieved using this approach amounted to 8.26·10−10 mol L−1for direct mercury determination in water solution (applying 200 s running accumulation). The procedure of the quantitative mercury isolation from complicated sample matrix was developed as well. It provides better selectivity and significant increase of sensitivity of mercury determination. In case of mercury isolation from one liter of water the detection limit is 6.23·10−11 mol L−1 (analyzing a greater sample volume the determined concentration could be lower).   相似文献   

15.
This paper describes the preparation and characterization of poly(ethyl cyanoacrylate) colloidal particles loaded with the organic fluorophore Rhodamine 6G. We studied the physicochemical properties of the colloidal particles: morphology, size-distribution, ζ-potential, fluorescent properties and photobleaching upon UV-light illumination. The properties of the obtained colloidal particles, as well as the dye loading efficiency, were found to depend on the concentrations of ethyl cyanoacrylate monomer and Rhodamine 6G in the polymerization medium. The fluorophore release from the colloidal particles in aqueous buffer is also studied.   相似文献   

16.
A new all plastic sensor for Co2+ ions based on 2-amino-5 (hydroxynaphtyloazo-1′)-1,3,4 thiadiazole (ATIDAN) as ionophore was prepared. The electrode exhibits a low detection limit of 1.5 × 10−6 mol L−1 and almost theoretical Nernstian slope in the activity range 4.0 × 10−6–1 × 10−1 mol L−1 of cobalt ions. The response time of the sensor is less than 10 s and it can be used over a period of 6 months without any measurable divergence in potential. The proposed sensor shows a fairly good selectivity for Co(II) over other metal ions. The electrode was successfully applied for determination of Co2+ in real samples and as an indicator electrode in potentiometric titration of Co2+ ions with EDTA.   相似文献   

17.
The potentiometric response characteristics of a diclofenac selective electrode, based on ion association in different plasticizers, were compared. The sensitivity, working range, detection limit and selectivity of membrane sensors demonstrated significant dependence on the type of plasticizers. The potentiometric unit presented a linear response toward diclofenac concentrations between 1 × 10−5 − 5 × 10−2 mol L−1, with slopes of approximately 60 mV dec−1, and exhibited a response time of 3 s. The potentiometric analysis of sodium diclofenac in pharmaceutical formulations was perfomed by the membrane electrode proposed and compared with the results of potentiometric titration given by the Pharmacopoeia of Ukraine.   相似文献   

18.
This work proposes a method for determination Cu(II) concentrations, based on the formation of a copper-1-nitroso-2-naphthol complex, in the presence of micelles; formed by a triblock copolymer, made up of two blocks of polyethylene oxide (PEO), and one block of polypropylene oxide (PPO). The insoluble copper complexes, are concentrated inside the hydrophobic micelle core; formed by the PPO block. For a solution containing 0.200 mg L−1 Cu(II), the proposed method had a relative standard deviation of 2.0% (n = 3); an absolute error from 0.11 to 0.39 mg L−1; and a linear calibration range, from 0.200 to 0.800 mg L−1. Detection and quantification limits, were 43.1 mg L−1 and 144 mg L−1, respectively. We show that there is excellent agreement, between the results obtained using our novel method; and those obtained using flame atomic absorption spectrometry: In the determination of Cu(II) concentrations, in Brazilian sugar-cane spirits. The proposed method, is the first to apply macromolecular micelle systems, to the determination of copper concentrations; and improves upon the results obtained using molecular surfactants. This method is environmentally friendly (since it does not use any organic solvents for extraction), and the triblock copolymer is biodegradable and non-toxic.   相似文献   

19.
A simple, sensitive and selective flotation method is described for the preconcentration and atomic absorption spectrometric determination of zinc ion in water and blood samples. At a solution pH of 5.2, 4-(2-pyridylazo-resorcinol) and Triton X-114 were used as hydrophobic ligand and non-ionic surfactant, respectively. The chemical variables affecting the preconcentration process were optimized. Under the optimized experimental conditions, the selective preconcentration and determination of as low zinc concentration as 6.5 μg L−1 can be made. The proposed method was successfully applied to the preconcentration and low-level determination of zinc in different water and blood serum samples.   相似文献   

20.
A simple and selective method for penicillin V potassium (PVK) determination by chemiluminescence (CL) was developed. Oxidation of PVK by alkaline hydrogen peroxide produces CL, which is greatly enhanced by N, N-dimethyl formamide (DMF) and N-cetyl-N,N,N-trimethylammonium bromide (CTMAB). Optimum conditions were established using luminometry. There is a linear relationship between the chemiluminescent peak height and the amount of PVK within the range 0.5–129.5 mg L−1, with a detection limit of 0.2 mg L−1. The coefficient of variation was 1.2% for 40 mg L−1 PVK solution (n = 7). The method is very simple, has high sensitivity and good selectivity, and is usable for process control. It was successfully utilized for the determination of PVK in pharmaceuticals and spiked human urine.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号