1.
A commercial particle beam interface coupled to a single quadrupole mass spectrometer has been used for a nontarget screening of highly contaminated water samples from a former gas plant. A liquid chromatographic system has been used to separate hydrophilic compounds with a high percentage water gradient without any loss of efficiency in the MS interface. The ground water showed a high pollution burden in the total ion current chromatogram. Full scan EI mass spectra have been obtained for identification of unknown compounds which could be assigned to oxidation products of heterocyclic aromatic compounds, some known constituents of coal tar. The identification of 6(5H)-phenanthridinone has been confirmed by comparison with a corresponding standard. The difficulties of an unequivocal identification of isoquinolinone and methyl derivatives of quinolinone based on their EI mass spectra are discussed. Received: 7 March 1997 / Revised: 15 May 1997 / Accepted: 22 May 1997  相似文献   

2.
A cluster-based chemical ionization method has been developed that produces protonated molecular ions from molecules introduced through a supersonic molecular beam interface. Mixed clusters of the analyte and a clustering agent (water or methanol) are produced in the expansion region of the beam, and are subsequently ionized by “fly through” electron impact (EI) ionization, which results in a mass spectrum that is a combination of protonated molecular ion peaks together with the conventional EI fragmentation pattern. The technique is presented and discussed as a tool complementary to electron impact ionization in supersonic molecular beams. Surface-induced dissociation on a rhenium oxide surface is also applied to simplify the mass spectra of clusters and reveal the analyte spectrum. The high gas flow rates involved with the supersonic molecular beam interface that enable the easy introduction of the clustering agents also have been used to introduce deuterating agents. An easy-to-use, fast, and routine on-line deuterium exchange method was developed to exchange active hydrogens (NH, OH). This method, combined with electron impact ionization, is demonstrated and discussed in terms of the unique information available through the EI fragmentation patterns, its ability to help in isomer identification, and possible applications with fast gas chromatography-mass spectrometry in supersonic molecular beams.  相似文献   

3.
A miniaturized, aerosol based interface for directly coupling a liquid chromatograph with a mass spectrometer is presented. The interface is entirely within the electron ionization (EI) source of the mass spectrometer and no additional, external devices are needed. This simple and effective approach exploits micro-flow nebulization technology providing a new interface suitable for a variety of applications of environmental and biological interest. The new interface provides necessary linearity, ruggedness, sensitivity, and reproducibility of response for trace level analysis, and readily interpretable mass spectra for unambiguous identification of unknown compounds of small to medium molecular weight.  相似文献   

4.
Upon the supersonic expansion of helium mixed with vapor from an organic solvent (e.g. methanol), various clusters of the solvent with the sample molecules can be formed. As a result of 70 eV electron ionization of these clusters, cluster chemical ionization (cluster CI) mass spectra are obtained. These spectra are characterized by the combination of EI mass spectra of vibrationally cold molecules in the supersonic molecular beam (cold EI) with CI-like appearance of abundant protonated molecules, together with satellite peaks corresponding to protonated or non-protonated clusters of sample compounds with 1-3 solvent molecules. Like CI, cluster CI preferably occurs for polar compounds with high proton affinity. However, in contrast to conventional CI, for non-polar compounds or those with reduced proton affinity the cluster CI mass spectrum converges to that of cold EI. The appearance of a protonated molecule and its solvent cluster peaks, plus the lack of protonation and cluster satellites for prominent EI fragments, enable the unambiguous identification of the molecular ion. In turn, the insertion of the proper molecular ion into the NIST library search of the cold EI mass spectra eliminates those candidates with incorrect molecular mass and thus significantly increases the confidence level in sample identification. Furthermore, molecular mass identification is of prime importance for the analysis of unknown compounds that are absent in the library. Examples are given with emphasis on the cluster CI analysis of carbamate pesticides, high explosives and unknown samples, to demonstrate the usefulness of Supersonic GC/MS (GC/MS with supersonic molecular beam) in the analysis of these thermally labile compounds. Cluster CI is shown to be a practical ionization method, due to its ease-of-use and fast instrumental conversion between EI and cluster CI, which involves the opening of only one valve located at the make-up gas path. The ease-of-use of cluster CI is analogous to that of liquid CI in ion traps with internal ionization, and is in marked contrast to that of CI with most other standard GC/MS systems that require a change of the ion source.  相似文献   

5.
The heavy petroleum fractions produced during refining processes need to be upgraded to useable products to increase their value. Hydrogenated heavy paraffinic fractions can be oxidised to produce high value products that contain a variety of oxygenates. These heavy oxygenated paraffinic fractions need to be characterised to enable the control of oxidation processes and to understand product properties. The accurate identification of the oxygenates present in these fractions by electron ionisation (EI) mass spectrometry is challenging due to the complexity of these heavy fractions. Adding to this challenge is the limited applicability of EI mass spectral libraries due to the absence of molecular ions from the EI mass spectra of many oxygenates. The separation of oxygenates from the complex hydrocarbon matrix prior to high temperature GC‐MS (HT‐GC‐MS) analysis reduces the complexity of these fractions and assists in the accurate identification of these oxygenates. Solid phase extraction (SPE) and supercritical fluid chromatography (SFC) were employed as prefractionation techniques. GC‐MS with supersonic molecular beams (SMBs) (also named GC‐MS with cold‐EI) utilises a SMB interface with which EI is done with vibrationally cold sample compounds in a fly‐through ion source (cold‐EI) resulting in a substantial increase in the molecular ion signal intensity in the mass spectrum. This greatly enhances the accurate identification of the oxygenates in these fractions. This study investigated the ionisation behaviour of oxygenated compounds using cold‐EI. The prefractionation by SPE and SFC and the subsequent analysis with GC‐MS with cold‐EI were applied to an oxygenated heavy paraffinic fraction.  相似文献   

6.
Electron ionization (EI) mass spectra of 46 compounds from several different compound classes were measured. Their molecular ion abundances were compared as obtained with 70‐eV EI, with low eV EI (such as 14 eV), and with EI mass spectra of vibrationally cold molecules in supersonic molecular beams (Cold EI). We further compared these mass spectra in their National Institute of Standards and Technology (NIST) library identification probabilities. We found that
  1. Low eV EI is not a soft ionization method, and it has little or no influence on the molecular ion relative abundances for large molecules and those with weak or no molecular ions.
  2. Low eV EI for compounds with abundant or dominant molecular ions in their 70 eV mass spectra results in the reduction of low mass fragment ions abundances thereby reducing their NIST library identification probabilities thus rarely justifies its use in real‐world applications.
  3. Cold EI significantly enhances the relative abundance of the molecular ions particularly for large compounds; yet, it retains the low mass fragment ions; hence, Cold EI mass spectra can be effectively identified by the NIST library.
  4. Different standard EI ion sources provide different 70 eV EI mass spectra. Among the Agilent technologies ion sources, the “Extractor” exhibits relatively abundant molecular ions compared with the “Inert” ion source, while the “High efficiency source” (HES) provides mass spectra with depleted molecular ions compared with the “Inert” ion source or NIST library mass spectra.
These conclusions are demonstrated and supported by experimental data in nine figures and two tables.  相似文献   

7.
A HPLC procedure has been optimized and successfully applied to porphyrins of environmental interest, such as etio and octaethylporphyrins and their VO and Ni compounds. The use of UV-Vis diode array allowed the detection of the analytes within the 5-15 ng/ml range. In order to achieve greater specificity and some structural information, the coupling of liquid chromatography with mass spectrometry was investigated, and the particle beam interface conditions were optimized. Electron impact (EI) spectra, comparable to those reported in the literature were obtained. The entire procedure has been applied to a real marine sediment, previously spiked with porphyrins to resemble oil-contaminated samples. The results pointed out that the method is suitable for such levels of analytes (5-10 microg/ml), allowing their identification and quantification with no need for purification steps.  相似文献   

8.
用EIMS、高分辨及B/E联动扫描技术, 对二十一个20-C-未被氧化的-对映-贝壳杉烯化合物的结构特征进行了研究, 根据它们的结构和质谱行为, 分为三种类型的化合物,B环的7C上有取代基, B环的6C上有取代基, B环的6C和7C同时有取代基, 并讨论裂解过程与A、B、C环上的取代基的影响。  相似文献   

9.
Propranolol, deuterium- and 18O-labeled propranolol and related compounds were analyzed using an ion trap mass spectrometer equipped with a modified Finnigan API electrospray interface. Sequential product ion (MSn) experiments were used to elucidate fragmentation pathways for these compounds. The observed ions were compared to those observed under electron impact (EI) conditions. The electrospray ionization (ESI) ion trap spectra, as well as the EI spectra, afford useful information to allow assignments of most product ions, many of which retain portions of the aliphatic three-carbon side chain.  相似文献   

10.
A commercially available particle beam interface developed by the Vestec Corporation has been coupled to a double-focusing high-resolution mass spectrometer (VG ZAB 2F) via a momentum separator. An ultraviolet detector was in-line with the interface and allowed monitoring of the eluting materials. With this instrumentation, complete electron-impact (EI) mass spectra on synthetic mixtures of steroids, nucleosides, and several derivatives of amino acids were recorded. Amongst these the EI mass spectra of 2,4-dinitrophenyl, 9-fluorenylmethoxycarbonyl and phenylthiohydantoin derivatives were obtained. The standard LC conditions used here (250 mm x 4.6 mm I.D., reversed-phase C18 column, 1.0 or 1.5 ml/min flow-rate, isocratic or gradient programming) allowed separation of the mixtures. The resulting mass spectra were compared with those obtained using a direct insertion probe. The agreement was excellent in most cases. Sensitivity measurements were performed on cholesterol and caffeine. A complete low-resolution mass spectrum can be obtained on 100 ng of cholesterol. Single-ion monitoring of the M+.of 200 pg of caffeine gave a 4:1 signal-to-noise ratio at m/z 194. Complete high-resolution mass spectra were obtained on 5 micrograms of cholesterol (loop injection) and on every peak of a five-steroid mixture of 5 micrograms each. The accuracy of the mass measurements were better than 5 m.m.u. for most cases. Three to four scans could be obtained for each liquid chromatographic peak. Mass-analyzed ion kinetic energy spectra were recorded on the M+.of 2.5 micrograms of cholesterol at m/z 386. Similarly the B/E linked scan of the same ion was recorded on 2.5 micrograms and 500 ng.  相似文献   

11.
Electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photo-ionization (APPI) are the most important techniques for the ionization of liquid samples. However, working under atmospheric pressure conditions, all these techniques involve some chemical rather than purely physical processes, and therefore, side reactions often yield to matrix-dependent ionization efficiencies. Here, a system is presented that combines both soft single-photon ionization (SPI) and hard 70 eV electron impact ionization (EI) of dissolved compounds under vacuum conditions. A quadrupole mass spectrometer was modified to enable direct EI, a technique developed by Cappiello et al. to obtain library-searchable EI mass spectra as well as soft SPI mass spectra of sample solutions. An electron beam-pumped rare gas excimer lamp working at 126 nm was used as well as a focusable vacuum UV light source for single-photon ionization. Both techniques, EI and SPI, were applied successfully for flow injection experiments providing library-matchable EI fragment mass spectra and soft SPI mass spectra, showing dominant signals for the molecular ion. Four model compounds were analyzed: hexadecane, propofol, chlorpropham, and eugenol, with detection limits in the picomolar range. This novel combination of EI and SPI promises great analytical benefits, thanks to the possibility of combining database alignment for EI data and molecular mass information provided by SPI. Possible applications for the presented ionization technology system are a matrix-effect-free detection and a rapid screening of different complex mixtures without time-consuming sample preparation or separation techniques (e.g., for analysis of reaction solutions in combinatorial chemistry) or a switchable hard (EI) and soft (SPI) MS method as detection step for liquid chromatography.
Figure
Scheme of the interface for introduction of liquid samples for vacuum photoionization/electron impact ionization MS  相似文献   

12.
Selected organotin compounds, relating to antifouling paints, have been analysed using a particle beam interface system designed for use on liquid chromatography–mass spectrometry (LC–MS) instruments. The resultant mass spectra matched those obtained from conventional electron-impact (EI) techniques, and consistent data over several injections and different elution times were obtained. Data obtained from tributyltin, dibutyltin, monobutyltin, triphenyltin and diphenyltin (each as the chlorides) are presented. This interface has been shown to maintain sample and therefore spectral integrity for these compounds and is of potential use in further investigations relating to organotin environmental pollution.  相似文献   

13.
The purpose of this article is to underline the possibility of efficiently using electron ionization (EI) in liquid chromatography (LC) and mass spectrometry (MS). From a historical perspective, EI accompanied the first attempts in LC-MS but, owing to several technical shortcomings, it was soon outshined by soft, atmospheric pressure ionization (API) techniques. Nowadays, two modern approaches, supersonic molecular beam LC-MS and direct-EI LC-MS, offer a valid alterative to API, and preserve the advantages of EI also in LC-MS applications. These advantages can be summarized in three crucial aspects: automated library identification; identification of unknown compounds, owing to EI extensive fragment information; inertness to coeluted matrix interferences owing to very unlikely ion–ion and ion–molecule interactions in the EI gas-phase environment. The direct-EI LC-MS interface is a simple and efficient solution able to produce high-quality, interpretable EI spectra from a wide range of low molecular weight molecules of different polarity. Because of the low operative flow rates, this interface relies on a nano-LC technology that helps in reducing the impact of the mobile phase on the gas-phase environment of EI. This review provides an extensive discussion on the role of EI in LC-MS interfacing, and presents in detail several performance aspects of the direct-EI LC-MS interface, especially in terms of response, mass-spectral quality, and matrix effects. In addition, several key applications are also reported.  相似文献   

14.
Accurate mass measurement (used to determine elemental formulae) is an essential tool for impurity identification in pharmaceutical development for process understanding. Accurate mass liquid chromatography/mass spectrometry (LC/MS) is used widely for these types of analyses; however, there are still many occasions when gas chromatography (GC)/MS is the appropriate technique. Therefore, the provision of robust technology to provide accurate mass GC/MS (and GC/MS/MS) for this type of activity is essential. In this report we describe the optimisation and application of a newly available atmospheric pressure chemical ionisation (APCI) interface to couple GC to time‐of‐flight (TOF) MS. To fully test the potential of the new interface the APCI source conditions were optimised, using a number of standard compounds, with a variety of structures, as used in synthesis at AstraZeneca. These compounds were subsequently analysed by GC/APCI‐TOF MS. This study was carried out to evaluate the range of compounds that are amenable to analysis using this technique. The range of compounds that can be detected and characterised using the technique was found to be extremely broad and include apolar hydrocarbons such as toluene. Both protonated molecules ([M + H]+) and radical cations (M+.) were observed in the mass spectra produced by APCI, along with additional ion signals such as [M + H + O]+. The technique has been successfully applied to the identification of impurities in reaction mixtures from organic synthesis in process development. A typical mass accuracy of 1–2 mm/zunits (m/z 80–500) was achieved allowing the reaction impurities to be identified based on their elemental formulae. These results clearly demonstrate the potential of the technique as a tool for problem solving and process understanding in pharmaceutical development. The reaction mixtures were also analysed by GC/electron ionisation (EI)‐MS and GC/chemical ionisation (CI)‐MS to understand the capability of GC/APCI‐MS relative to these two firmly established techniques. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

15.
Six synthesized 6-nitroquipazine derivatives were examined by electron ionization (EI) and electrospray ionization (ESI) mass spectrometry in positive and negative ion mode. The compounds exhibit high affinity for the serotonin transporter (SERT) and belong to a new class of SERT inhibitors. The EI mass spectra registered in negative ion mode showed prominent molecular ions for all the compounds studied. All EI mass spectra and all ESI mass spectra showed similar fragmentation pathways of molecular ions, but the pathways differed between EI and ESI. The differences were explained with the aid of theoretical evaluation of the stability of the respective radical ions (EI MS) and protonated ions (ESI MS).  相似文献   

16.
A method to extract and analyze organic compounds from water is presented. A solid phase micro-trap (micro-SPE) directly connected to the micro-analytical column is used. Sensibility and specificity needed for trace analysis are guaranteed by mass spectrometric electron ionization (EI) detection. A new micro-HPLC/EI-MS interface called Capillary-EI (Cap-EI) is described. The ultimate evolution of this interface is also presented: in this extremely simplified interface the analytes are nebulized, vaporized and ionized in the small volume of the ion source. This interface, called Direct-EI, exploits nano- and micro-HPLC columns with a mobile phase flow rates ranging from 0.3 to 1.5 microL/min. Contemporary use of micro SPE, Cap-EI or Direct-EI gives us a powerful technique to identify and quantify organic pollutants at part per billion level (ppb).  相似文献   

17.
Comprehensive gas chromatography (GC) has emerged in recent years as the technique of choice for the analysis of volatile and semivolatile compounds in complex matrices. Coupling it with high‐resolution mass spectrometry (MS) makes a powerful tool for identification and quantification of organic compounds. The results obtained in this study showed a significant improvement by using GC×GC‐EI‐MS in comparison with GC‐EI‐MS; the separation of chromatogram peaks was highly improved, which facilitated detection and identification. However, the limitation of Orbitrap mass analyzer compared with time‐of‐flight analyzer is the data acquisition rate; the frequency average was about 25 Hz at a mass resolving power of 15.000, which is barely sufficient for the proper reconstruction of the narrowest chromatographic peaks. On the other hand, the different spectra obtained in this study showed an average mass accuracy of about 1 ppm. Within this average mass accuracy, some reasonable elemental compositions can be proposed and combined with characteristic fragment ions, and the molecules can be identified with precision. At a mass resolving power of 7.500, the scan rate reaches 43 Hz and the GC×GC‐MS peaks can be represented by more than 10 data points, which should be sufficient for quantification. The GC×GC‐MS was also applied to analyze a cellulose bio‐oil sample. Following this, a highly resolved chromatogram was obtained, allowing EI mass spectra containing molecular and fragment ions of many distinct molecules present in the sample to be identified.  相似文献   

18.
The mass spectra of tert-butyldimethylsilyl (TBDMS) derivatives of 17 amino acids were obtained using electron ionization (EI) and atmospheric pressure photochemical ionization (APPhCI) mass spectrometry. The APPhCI mass spectra for all of the derivatives except arginine were shown to consist of only molecular [M](+.) and quasimolecular [MH](+) ions whereas, in the case of EI, the compounds in question underwent a drastic fragmentation. The application of APPhCI to gas chromatography-mass spectrometry enables a reliable identification of the TBDMS derivatives of amino acids in a mixture, even if its components are only partially resolved, due to the unique molecular masses for each compound. Comparison of the respective positive-ion chemical ionization (PICI) mass spectra available in the literature with APPhCI spectra has shown that, in the case of PICI, unlike APPhCI, noticeable fragmentation occurs.  相似文献   

19.
A major benefit of gas chromatography/mass spectrometry (GC/MS) with a supersonic molecular beam (SMB) interface and its fly-through ion source is the ability to obtain electron ionization of vibrationally cold molecules (cold EI), which show enhanced molecular ions. However, GC/MS with an SMB also has the flexibility to perform 'classical EI' mode of operation which provides mass spectra to mimic those in commercial 70 eV electron ionization MS libraries. Classical EI in SMB is obtained through simple reduction of the helium make-up gas flow rate, which reduces the SMB cooling efficiency; hence the vibrational temperatures of the molecules are similar to those in traditional EI ion sources. In classical EI-SMB mode, the relative abundance of the molecular ion can be tuned and, as a result, excellent identification probabilities and very good matching factors to the NIST MS library are obtained. Classical EI-SMB with the fly-through dual cage ion source has analyte sensitivity similar to that of the standard EI ion source of a basic GC/MS system. The fly-through EI ion source in combination with the SMB interface can serve for cold EI, classical EI-SMB, and cluster chemical ionization (CCI) modes of operation, all easily exchangeable through a simple and quick change (not involving hardware). Furthermore, the fly-through ion source eliminates sample scattering from the walls of the ion source, and thus it offers full sample inertness, tailing-free operation, and no ion-molecule reaction interferences. It is also robust and enables increased column flow rate capability without affecting the sensitivity.  相似文献   

20.
IntroductionIn1893,Pietro Biginelli reported the first synthe-sis(termed the Biginelli reaction)of3,4-dihydropyrim-idinone(denoted as“oxo-orO-Biginelli compound”in-cluding its derivatives,type A in Scheme1).In thelast decade,interest in these compounds …  相似文献   