Duggan MP  McCreedy T  Aylott JW 《The Analyst》2003,128(11):1336-1340
The on-chip measurement of absorbing species has proven to be challenging, particularly with respect to the sample pathlengths available in a miniaturised system. This paper demonstrates how the principles of total internal reflection can be utilised to form a liquid-core waveguide along a single microfluidic channel, increasing the sampling pathlength to 5 mm while maintaining a detection volume of < or = 1 microL. This was achieved using the Teflon fluoropolymers PTFE, FEP and AF as cladding for the liquid-core waveguide. In conjunction with a 3D chip architecture, the use of the liquid-core waveguide enables more efficient use of the probing light beam along with easy and effective coupling of the source, microfluidic chip and the detection system. The confirmation that waveguiding was occurring was successfully demonstrated and the subsequent spectrophotometric analysis of crystal violet provided a linear calibration with reproducibility (< 2.4% RSD) and limits of detection (< 1.3 microM), comparable to absorbance measurements made with a standard UV-Vis spectrophotometer.  相似文献   

2.
L Li  X Bi  J Yu  CL Ren  Z Liu 《Electrophoresis》2012,33(16):2591-2597
Manufacturing materials are an essential element for the fabrication of microfluidic chips. PDMS, the most widely used polymeric material, is associated with apparent disadvantages such as hydrophobic nature, while other materials also suffer from some limitations. In this paper, a new soft lithographic route was proposed for the facile manufacturing of hydrophilic sandwich microchips, using bisphenol A based epoxy acrylate (BABEA) as a new patterning material. The BABEA copolymers are hydrophilic, highly transparent in visible range while highly untransparent when the wavelength is less than 290 nm, and of high replication fidelity. By combining with appropriate monomers, including glycidyl methacrylate, methylmethacrylate, and acrylic acid, the copolymers contain active functional groups, which allows for easy postmodification for desirable functional units. A fabrication procedure was proposed for manufacturing hybrid quartz/BABEA copolymer/quartz microchips. In the procedure, no micromachining equipments, wet etching, or imprinting techniques were involved, making the fabrication approach applicable in ordinary chemistry laboratories. The performance of the prepared microchips was demonstrated in terms of CIEF with UV-whole channel imaging detection. The hydrophilic microchannel ensures stable focusing while the polymeric middle layer acts as a perfectly aligned optical slit for whole channel UV absorbance detection.  相似文献   

3.
A new, versatile architecture is presented for microfluidic devices made entirely from glass, for use with reagents which would prove highly corrosive for silicon. Chips consist of three layers of glass wafers bonded together by fusion bonding. On the inside wafer faces a network of microfluidic channels is created by photolithography and wet chemical etching. Low dead-volume fluidic connections between the layers are fabricated by spark-assisted etching (SAE), a computer numerical controlled (CNC)-like machining technique new to microfluidic system fabrication. This method is also used to form a vertical, long path-length, optical cuvette through the middle wafer for optical absorbance detection of low-concentration compounds. Advantages of this technique compared with other, more standard, methods are discussed. When the new glass-based device for flow-injection analysis of ammonia was compared with our first-generation chips based on silicon micromachining, concentration sensitivity was higher, because of the longer path-length of the optical cuvette. The dependence of dispersion on velocity profile and on channel cross-sectional geometry is discussed. The rapid implementation of the devices for an organic synthesis reaction, the Wittig reaction, is also briefly described.  相似文献   

4.
An integrated microfluidic distillation system is proposed for separating a mixed ethanol-methanol-water solution into its constituent components. The microfluidic chip is fabricated using a CO2 laser system and comprises a serpentine channel, a boiling zone, a heating zone, and a cooled collection chamber filled with de-ionized (DI) water. In the proposed device, the ethanol-methanol-water solution is injected into the microfluidic chip and driven through the serpentine channel and into the collection chamber by means of a nitrogen carrier gas. Following the distillation process, the ethanol-methanol vapor flows into the collection chamber and condenses into the DI water. The resulting solution is removed from the collection tank and reacted with a mixed indicator. Finally, the methanol concentration is inversely derived from the absorbance measurements obtained using a spectrophotometer. The experimental results show the proposed microfluidic system achieves an average methanol distillation efficiency of 97%. The practicality of the proposed device is demonstrated by detecting the methanol concentrations of two commercial fruit wines. It is shown that the measured concentration values deviate by no more than 3% from those obtained using a conventional bench top system.  相似文献   

5.
利用溴化1-丁基-3-甲基咪唑离子液体/碳酸钠溶液双水相体系,实现了多相层流液液萃取.以具有较高折射率的离子液体为液芯,较低折射率的盐溶液为包层,实现了液液波导吸光度检测.据此建立了一种液液萃取与液液波导检测集成化的微流控分析系统.该系统对甲酚红试样的萃取率在93%以上,对甲酚红试样检测的线性范围为0.01~0.40 mg/m L,相对标准偏差为3.4%(n=11),检出限为3.8μg/m L(3σ).该系统将萃取分离与液液波导长光程吸光度检测集成在一起,为拓展吸光度检测在微流控系统中的应用提供了新思路.  相似文献   

6.
The separation and UV absorbance detection of four toxic alkaloids, colchicine, thiocolchicine, colchicoside, and thiocolchicoside, on a microchip-based capillary electrophoresis device are reported. To increase the sensitivity of UV absorbance detection, optical cells with extended path lengths were integrated into the separation channel during the microfabrication process. The absorbance values realized on the microchip using these optical cells were proportional to the increase in average depths according to the Beer-Lambert Law, resulting in sensitivity enhancements by as much as five times. Linearity of response was observed from 5.0 to 500 mg L−1 of colchicine, with detection limits ranging from 2 to 6 mg L−1 depending upon the specific alkaloid and the dimension of the optical cell. The extraction of colchicine from spiked milk samples was performed and an average recovery rate of 83% with a relative standard deviation of 3.8% was determined using the optimized conditions on the microchip.  相似文献   

7.
Y Zhang  Y Tang  YH Hsieh  CY Hsu  J Xi  KJ Lin  X Jiang 《Lab on a chip》2012,12(17):3012-3015
This work reports an integrated platform combining localized-surface plasmon resonance (LSPR) and microfluidic chips to carry out multiplexed and label-free protein analysis. We fabricated an optical bench to enable detection using only a laboratory UV-Vis spectrophotometer. This assay not only improves throughput, but also allows quantitative analysis.  相似文献   

8.
Ma B  Zhou X  Wang G  Dai Z  Qin J  Lin B 《Electrophoresis》2007,28(14):2474-2477
We exploited a PDMS-quartz hybrid microchip with a thin PDMS membrane on the concave detection window for UV absorbance detection. The thickness of the PDMS membrane is about 100 mum, with high UV transmittance. As compared to a PDMS-quartz hybrid chip with a common detection window, the proposed one exhibited over an one order of magnitude sensitivity enhancement, and an about two orders of magnitude S/N increase for gastrodin (p-hydroxymethylphenyl-beta-D-glucopyranoside). In addition, the limit of the detection wavelength has been extended from 240 to 210 nm, which is otherwise impossible for a traditional PDMS-quartz hybrid microchip. This kind of microchip has the potential for a large range of applications in an integrated microfluidic system with UV detection.  相似文献   

9.
The optical properties and surface area of quantum dots (QDs) have made them an attractive platform for the development of nucleic acid biosensors based on fluorescence resonance energy transfer (FRET). Solid-phase assays based on FRET using mixtures of immobilized QD–oligonucleotide conjugates (QD biosensors) have been developed. The typical challenges associated with solid-phase detection strategies include non-specific adsorption, slow kinetics of hybridization, and sample manipulation. The new work herein has considered the immobilization of QD biosensors onto the surfaces of microfluidic channels in order to address these challenges. Microfluidic flow can be used to dynamically control stringency by adjustment of the potential in an electrokinetic-based microfluidics environment. The shearing force, Joule heating, and the competition between electroosmotic and electrophoretic mobilities allow the optimization of hybridization conditions, convective delivery of target to the channel surface to speed hybridization, amelioration of adsorption, and regeneration of the sensing surface. Microfluidic flow can also be used to deliver (for immobilization) and remove QD biosensors. QDs that were conjugated with two different oligonucleotide sequences were used to demonstrate feasibility. One oligonucleotide sequence on the QD was available as a linker for immobilization via hybridization with complementary oligonucleotides located on a glass surface within a microfluidic channel. A second oligonucleotide sequence on the QD served as a probe to transduce hybridization with target nucleic acid in a sample solution. A Cy3 label on the target was excited by FRET using green-emitting CdSe/ZnS QD donors and provided an analytical signal to explore this detection strategy. The immobilized QDs could be removed under denaturing conditions by disrupting the duplex that was used as the surface linker and thus allowed a new layer of QD biosensors to be re-coated within the channel for re-use of the microfluidic chip.  相似文献   

10.
提出了一种基于芯片-毛细管复合装置的紫外检测-微流控芯片毛细管电泳分析系统.采用小死体积的耦合技术实现了石英毛细管与“十”字通道型微流控玻璃芯片的耦合.本系统的紫外检测灵敏度与商品化毛细管电泳仪相当.采用夹流进样方式,达到较高的进样重现性,2mmol/L苯甲酸的峰高相对标准偏差(RSD)为1.5%(n=11).可用于复方磺胺甲唑片剂的两种有效成分的快速分离.  相似文献   

11.
This work demonstrates the development of microfluidic compact discs (CDs) for protein purification and fractionation integrating a series of microfluidic features, such as microreservoirs, microchannels, and microfluidic fractionators. The CDs were fabricated with polydimethylsiloxane (PDMS), and each device contained multiple identical microfluidic patterns. Each pattern employed a microfluidic fractionation feature with operation that was based on the redirection of fluid into an isolation chamber as a result of an overflow. This feature offers the advantage of automated operation without the need for any external manipulation, which is independent of the size and the charge of the fractionated molecules. The performance of the microfluidic fractionator was evaluated by its integration into a protein purification microfluidic architecture. The microfluidic architecture employed a microchamber that accommodated a monolithic microcolumn, the fractionator, and an isolation chamber, which was also utilized for the optical detection of the purified protein. The monolithic microcolumn was polymerized “in situ” on the CD from a monolith precursor solution by microwave-initiated polymerization. This technique enabled the fast, efficient, and simultaneous polymerization of monoliths on disposable CD microfluidic platforms. The design of the CD employed allows the integration of various processes on a single microfluidic device, including protein purification, fractionation, isolation, and detection.   相似文献   

12.
基于液芯波导原理的微流控芯片长光程光度检测系统   总被引:2,自引:0,他引:2  
提出了一种基于液芯波导(Liquidcorewaveguide,LCW)原理的微流控芯片吸收光度检测系统.通过芯片与外界接口技术实现液芯波导管与芯片的耦合,建立了芯片上长光程(毫米至厘米级)吸收光度检测池.采用邻菲啉-铁(Ⅱ)显色体系验证系统分析性能,以5.5cm外覆TeflonAF液芯波导管作为检测池(检测池体积240nL)时,芯片系统的检测线性范围为0.03~50μmol/L,对邻菲啉-铁(Ⅱ)配合物的检出限为8nmol/L,检测池有效光程达1.7cm,分析精度RSD(n=5)为0.8%.  相似文献   

13.
Recent advance in liquid crystal (LqC) based immunoassays enables label-free detection of antibody, but manual preparation of LqC cells and injection of LqC are required. In this work, we developed a new format of LqC-based immunoassay which is hosted in a microfluidic device. In this format, the orientations of LqC are strongly influenced by four channel walls surrounding the LqC. When the aspect ratio (depth/width) of the channel is smaller than 0.38, LqC orients homeotropically inside the microchannel and appears dark. After antigens bind to immobilized antibodies on the channel walls, a shift of the LqC appearance from dark to bright (due to the disruption of LqC orientation) can be visualized directly. To streamline the immunoassay process, a tubing cartridge loaded with a sample solution, washing buffers and a plug of LqC is connected to the microfluidic device. By using pressure-driven flow, the cartridge allows antigen/antibody binding, washing and optical detection to be accomplished in a sequential order. We demonstrate that this microfluidic immunoassay is able to detect anti-rabbit IgG with a naked-eye detection limit down to 1 μg mL−1. This new format of immunoassay provides a simple and robust approach to perform LqC-based label-free immunodetection in microfluidic devices.  相似文献   

14.
A novel determination method for urea using an acid urease column-FIA system was developed, and the system was applied to the determination of urea in rice wine. This novel FIA system was characterized by CO2 detection due to the property of acid urease and by a microfluidic gas-diffusion device with the use of an ultra-thin hollow fiber membrane. A biosensing system fabricated in this study was assembled with a double-plunger pump, a sample-injection valve, an immobilized acid urease column as a recognition element for the assay of urea, a gas-diffusion unit, and a flow-type spectrophotometer. The gas-diffusion unit consisted of a double-tubing structure in which the outer tubing was made of PTFE (i.d. 1.0 mm; o.d. 1.5 mm) and the inner tubing was of porous PTFE (i.d. 0.19 mm; o.d. 0.25 mm). Standard urea solutions (20 microl) were measured through monitoring variations in the absorbance of a coloring agent solution resulting from a pH shift due to carbon dioxide molecules being enzymatically generated. A wide and linear relationship was obtained between the concentration of urea (16 microM - 1.0 mM) and the change in absorbance. This FIA system has great advantages that the system did not suffer from ammonia and ethanol in samples. This system, armed with a microfluidic gas-diffusion device, was applicable to the determination of various substrates of many kinds of decarboxylase, amino-acid oxidase, and amino-acid oxygenase, producing CO2 and NH3 molecules.  相似文献   

15.
Song W  Yang J 《Lab on a chip》2012,12(7):1251-1254
We present a novel optofluidic differential method for carrying out absorbance spectroscopy of sub-nanolitre volumes of liquid samples on a microfluidic chip. Due to the reduction of liquid volume, the absorbance detection in microfluidics is often hindered by either low sensitivity or complex fabrication. To address this issue, we introduced an optofluidic modulator which can be easily integrated into a PDMS (polydimethylsiloxane) based microfluidic chip. The modulator was controlled by the fluid pressure and the absorbance spectrum of the analyte was obtained by taking differential measurements between the analyte and reference medium. An advantage is that this method doesn't need a complicated fabrication step. It is compatible with conventional microfluidic chips and measurements can be carried out on a normal transmission microscope. The performance of the device was tested by measuring solutions containing methylene blue, with concentrations as low as 13 μM.  相似文献   

16.
As is well known, controlling the local magnetic field distribution on the micrometer scale in a microfluidic chip is significant and has many applications in bioanalysis based on magnetic beads. However, it is a challenge to tailor the magnetic field introduced by external permanent magnets or electromagnets on the micrometer scale. Here, we demonstrated a simple approach to controlling the local magnetic field distribution on the micrometer scale in a microfluidic chip by nickel patterns encapsulated in a thin poly(dimethylsiloxane) (PDMS) film under the fluid channel. With the precisely controlled magnetic field, magnetic bead patterns were convenient to generate. Moreover, two kinds of fluorescent magnetic beads were patterned in the microfluidic channel, which demonstrated that it was possible to generate different functional magnetic bead patterns in situ, and could be used for the detection of multiple targets. In addition, this method was applied to generate cancer cell patterns.  相似文献   

17.
The design, fabrication and testing of a photolithographically fabricated, glass-based multireflection absorbance cell for microfluidic devices, in particular microchip-based capillary electrophoresis (CE) systems is described. A multireflection cell was fabricated lithographically using a three-mask process to pattern aluminum mirrors above and below a flow channel in a chip, with 30 microm diameter optical entrance or exit apertures (one in each mirror) positioned 200 microm apart. Source and detector were positioned on opposite sides, and the metal mirrors were made 1 cm square, to reduce stray light effects. Calibration curves using bromothymol blue (BTB) with a 633 nm source (He:Ne laser) were linear to at least 0.5 absorbance units, with typical r2 values of 0.9997, relative standard deviations in the slopes of +/- 1.3%, and intercepts of zero within experimental error. Effective optical pathlengths of 50-272 microm were achieved, compared to single-pass pathlengths of 10-30 microm, corresponding to sensitivity enhancements (i.e., optical path length increase) of 5 to 10-fold over single-pass devices. Baseline absorbance noise varied within a factor of two in almost all devices, depending only weakly on path length. This device can give much higher absorbance sensitivity, and should be much easier to manufacture than planar, glass-based devices previously reported.  相似文献   

18.
A microfluidic device with integrated waveguides and a long path length detection cell for UV/Vis absorbance detection is presented. The 750 microm U-cell detection geometry was evaluated in terms of its optical performance as well as its influence on efficiency for electrophoretic separations in the microdevice. Stray light was found to have a strong effect on both, the sensitivity of the detection and the available linear range. The long path length U-cell showed a 9 times higher sensitivity when compared to a conventional capillary electrophoresis (CE) system with a 75 microm inner diameter (ID) capillary, and a 22 times higher sensitivity than with a 50 microm ID capillary. The linear range was comparable to that achieved in a 75 microm ID capillary and more than twice as large as in a 50 microm ID capillary. The use of the 750 microm U-cell did not contribute significantly to band broadening; however, a clear quantification was made difficult by the convolution of several other band broadening sources.  相似文献   

19.
We describe a microfluidic cytometer that performs simultaneous optical and electrical characterisation of particles. The microfluidic chip measures side scattered light, signal extinction and fluorescence using integrated optical fibres coupled to photomultiplier tubes. The channel is 80 μm high and 200 μm wide, and made from SU-8 patterned and sandwiched between glass substrates. Particles were focused into the analysis region using 1-D hydrodynamic focusing and typical particle velocities were 0.1 ms(-1). Excitation light is coupled into the detection channel with an optical fibre and focused into the channel using an integrated compound air lens. The electrical impedance of particles is measured at 1 MHz using micro-electrodes fabricated on the channel top and bottom. This data is used to accurately size the particles. The system is characterised using a range of different sized polystyrene beads (fluorescent and non-fluorescent). Single and mixed populations of beads were measured and the data compared with a conventional flow cytometer.  相似文献   

20.
Y Hanada  K Sugioka  K Midorikawa 《Lab on a chip》2012,12(19):3688-3693
The demand for increased sensitivity in the concentration analysis of biochemical liquids is a crucial issue in the development of lab on a chip and optofluidic devices. We propose a new design for optofluidic devices for performing highly sensitive biochemical liquid assays. This design consists of a microfluidic channel whose internal walls are coated with a polymer and an optical waveguide embedded in photostructurable glass. The microfluidic channel is first formed by three-dimensional femtosecond laser micromachining. The internal walls of the channel are then coated by the dipping method with a polymer that has a lower refractive index than water. Subsequently, the optical waveguide is integrated with the microfluidic channel. The polymer coating on the internal walls permits the probe light, which is introduced by the optical waveguide, to propagate along the inside of the microfluidic channel. This results in a sufficiently long interaction length between the probe light and a liquid sample in the channel and thus significantly improves the sensitivity of absorption measurements. Using the fabricated optofluidic chips, we analyzed protein in bovine serum albumin to concentrations down to 7.5 mM as well as 200 nM glucose-D.  相似文献   