首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
This project evaluated solid-phase extraction (SPE) combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) to determine the trace amount of rosiglitazone in human urine. The analytical performance of four modes of LC-MS and tandem MS operation (atmospheric pressure chemical ionization (APCI), electrospray ionization (ESI), positive and negative ionization) was compared for two mass spectrometers, a triple-quadrupole and a quadrupole ion trap instrument. Rosiglitazone was extracted from urine using a SPE cartridge of 50mg C8 sorbent and acetonitrile used as the eluting solvent. Samples were then separated on a RP18 column interfaced with a tandem mass spectrometer. The recovery of rosiglitazone was greater than 91.2%. The urine assay combining SPE and LC-APCI-MS/MS of triple-quadrupole was proved a very selective and sensitive method for determination of trace rosiglitazone. The assay was linear over a wide range, with a lower limit of quantification of 0.1 ng/mL using 1 mL of urine. The intra- and inter-day precisions were <9.8% and <7.9%, respectively, and the accuracies were in the range 91.0-103.6%. The rosiglitazone concentration profile in human urine was also determined. The results of this study reveal the adequacy of SPE-LC-APCI-MS/MS method for analyzing rosiglitazone from diabetic patients' urines. The concentrations of rosiglitazone were detected to range from 760 to 164 pg/mL.  相似文献   

2.
An on-line solid-phase extraction liquid chromatography/tandem mass spectrometry (SPE LC/MS/MS) assay using a newly developed SPE column and a monolithic column was developed and validated for direct analysis of plasma samples containing multiple analytes. This assay was developed in an effort to increase bioanalysis throughput and reduce the complexity of on-line SPE LC/MS/MS systems. A simple column-switching configuration that requires only one six-port valve and one HPLC pumping system was employed for on-line plasma sample preparation and subsequent gradient chromatographic separation. The resulting analytical method couples the desired sensitivity with ease of use. The method was found to perform satisfactorily for direct plasma analysis with respect to assay linearity, specificity, sensitivity, precision, accuracy, carryover, and short-term stability of an eight-analyte mixture in plasma. A gradient LC condition was applied to separate the eight analytes that cannot be distinctly differentiated by MS/MS. With a run time for every injection of 2.8 min, a minimum of 300 direct plasma injections were made on one on-line SPE column without noticeable changes in system performance. Due to the ruggedness and simplicity of this system, generic methods can be easily developed and applied to analyze a wide variety of compounds in a high-throughput manner without laborious off-line sample preparation.  相似文献   

3.
A method for the liquid chromatography/tandem mass spectrometric (LC/MS/MS) quantification of piritramide, a synthetic opioid, in plasma after conventional off-line solid-phase extraction (SPE) and in urine by on-line SPE-LC/MS/MS in positive electrospray mode was developed and validated. Applicability of the on-line approach for plasma samples was also tested. Deuterated piritramide served as internal standard. For the off-line SPE plasma method mixed cation-exchange SPE cartridges and a 150 x 2 mm C18 column with isocratic elution were used. For the on-line SPE method, a Waters Oasis HLB extraction column and the same C18 analytical column in a column-switching set-up with gradient elution were utilized. All assays were linear within a range of 0.5-100 ng/mL with a limit of detection of 0.05 ng/mL. The intra- and interday coefficients of variance ranged from 1.3 to 6.1% for plasma and 0.5 to 6.4% for urine, respectively. The extraction recovery for the off-line plasma assay was between 90.7 and 100.0%. Influence of matrix effects, and freeze/thaw and long-term stability were validated for both approaches; influence of urine pH additionally for quantification in urine.  相似文献   

4.
A liquid chromatographic/tandem mass spectrometric (LC/MS/MS) multiresidue method for the simultaneous quantitative determination of oxytetracycline, 4-epi-oxytetracycline, tetracycline, 4-epi-tetracycline, chlortetracycline, 4-epi-chlortetracycline and doxycycline in milk has been developed. An extraction procedure consisting of a liquid extraction of the milk samples with trichloroacetic acid was performed. The extract was centrifuged and the supernatant was filtered. Solid-phase extraction (SPE) with an OASIS HLB SPE column was used to clean up the sample extracts. The samples were analysed by LC/MS/MS. The LC separation was performed on a reversed-phase C18 column using gradient elution with a mobile phase consisting of water and a mixture of methanol/acetonitrile. The tetracycline analytes were detected with a quadrupole mass spectrometer using positive ion electrospray ionisation. The confirmatory method has acceptable detection limits and the different tetracyclines can be detected at a residue concentration between 5 and 20 microg/L. The method is validated according to the European requirements for veterinary drug residues and all determined parameters were found to conform to the criteria. The recovery values ranged from 90.4 to 101.2% with relative standard deviations (RSDs) no larger than 9.7%. The overall or between-day precision of the analytical assay determined as repeatability at several residue concentrations and expressed as RSD ranged from 3.3 to 10%. This analytical assay is a useful tool within the Belgian monitoring programme for confirmation of samples which have been positively screened for residues of tetracyclines in raw farm cow's milk.  相似文献   

5.
Quantification of F(2)-isoprostanes is considered a reliable index of the oxidative stress status in vivo. Several immunoassays and chromatography/mass spectrometry-based assays are available for 15-F(2t)-isoprostane quantification. However, it remains unclear if results of immunoassays using different assays can be compared with those of liquid chromatography/mass spectrometry (LC/MS) assays. Previous studies comparing enzyme-linked immunosorbent assay (ELISA) and more specific gas chromatography/mass spectrometry assays have already indicated that ELISAs may overestimate 15-F(2t)-isoprostane concentrations in human plasma. Concentrations of 15-F(2t)-isoprostane in 25 human plasma and urine samples were measured by three commercially available ELISA assays (Assay Designs, Cayman Chemical and Oxford Biomedical Research) and compared with the concentrations measured with a validated, semi-automated high-throughput HPLC tandem mass spectrometry assay (LC/LC-MS/MS). All three ELISAs measured substantially higher 15-F(2t)-isoprostane concentrations (2.1-182.2-fold higher in plasma; 0.4-61.9-fold higher in urine) than LC/LC-MS/MS. Utilization of solid-phase extraction (SPE) columns, especially isoprostane affinity purification columns, brought ELISA isoprostane urine concentrations closer to the LC/LC-MS/MS results. However, SPE did not have much of an effect on ELISA plasma concentrations which remained significantly higher than corresponding LC/LC-MS/MS results. A poor correlation not only between LC/LC-MS/MS and immunoassay results, but also among the immunoassays was found. Especially in plasma, ELISAs grossly overestimate 15-F(2t)-isoprostane concentrations and are not comparable with each other or with LC/LC-MS/MS. It is most disturbing that a sample with relatively high concentrations measured with one ELISA may show low concentrations with another ELISA, and vice versa, potentially affecting the conclusions drawn from such data. The use of specific mass spectrometry-based assays seems advisable.  相似文献   

6.
A simplified protein precipitation/mixed-mode cation-exchange solid-phase extraction (PPT/SPE) procedure has been investigated. A mixture of acetonitrile and methanol along with formic acid was used to precipitate plasma proteins prior to selectively extracting the basic drug. After vortexing and centrifugation, the supernatants were directly loaded onto an unconditioned Oasis MCX microElution 96-well extraction plate, where the protonated drug was retained on the negatively charged sorbent while interfering neutral lipids, steroids or other endogenous materials were washed away. Normal wash steps were deemed unnecessary and not used before sample elution. The sample extracts were analyzed under both conventional and high-speed liquid chromatography/tandem mass spectrometry (LC/MS/MS) conditions to examine the feasibility of the PPT/SPE procedure for human plasma sample clean-up. For the conventional LC/MS/MS method, chromatographic separation was achieved on a C18, 2.1 x 50 mm column with gradient elution (k' = 5.5). The mobile phase contained 0.1% formic acid in water and 0.1% formic acid in acetonitrile. For the high-speed LC/MS/MS method, chromatographic separation was achieved on a C18, 2.1 x 10 mm guard column with gradient elution (k' = 2.2, Rt = 0.26 min). The mobile phase contained 0.1% formic acid in water and 0.001% trifluoroacetic acid in acetonitrile. Detection for both conventional and high-speed LC/MS/MS methods was by positive ion electrospray tandem mass spectrometry on a ThermoElectron Finnigan TSQ Quantum Ultra, where enhanced resolution (RP 2000; 0.2 amu) was used for high-speed LC/MS/MS. The standard curve, ranging from 0.5 to 100 ng/mL, was fitted to a 1/x weighted quadratic regression model.This combined PPT/SPE procedure effectively eliminated time-consuming sorbent conditioning and wash steps, which are essential for a conventional mixed-mode SPE procedure, but retained the advantages of both PPT (removal of plasma proteins) and mixed-mode SPE (analyte selectivity). The validation results demonstrated that this PPT/SPE procedure was well suited for both conventional and high-speed LC/MS/MS analyses. In comparison with a conventional mixed-mode SPE procedure, the simplified PPT/SPE process provided comparable sample extract purity. This simple sample clean-up procedure can be applied to other basic compounds with minor modifications of PPT solvents.  相似文献   

7.
The application of 384-well format solid phase extraction (SPE) for bioanalysis using liquid chromatography/tandem mass spectrometry (LC/MS/MS) is reported and a 384-well SPE method for the 5-HT agonist sumatriptan in human plasma described. Plasma samples were extracted on a prototype low-density polyethylene 384-well SPE block using a packed bed of 5 mg Oasistrade mark HLB. Liquid handling was automated by a combination of a robotic sampler processor and a 96/384 multi-channel dispensing station. Samples and SPE reagents were drawn through the SPE block by centrifugation. The extracts were analysed by LC/MS/MS with thermally and pneumatically assisted electrospray ionisation and selected reaction monitoring. The method is used to illustrate and discuss the feasibility and viability of sample preparation techniques in high-density microtitre plate format for routine bioanalysis.  相似文献   

8.
An analytical method was developed for the determination in urine of 2 metabolites of diazinon: 6-methyl-2-(1-methylethyl)-4(1H)-pyrimidinone (G-27550) and 2-(1-hydroxy-1-methylethyl)-6-methyl-4(1H)-pyrimidinone (GS-31144). Two of the urine sample preparation procedures presented rely on gas chromatography/mass selective detection (GC/MSD) in the selected ion monitoring mode for determination of G-27550. For fast sample preparation and a limit of quantitation (LOQ) of 1.0 ppb, urine samples were purified by using ENV+ solid-phase extraction (SPE) columns. For analyte confirmation at an LOQ of 0.50 ppb, classical liquid/liquid partitioning was used before further purification in a silica SPE column. An SPE sample preparation procedure and liquid chromatography/electrospray ionization/mass spectrometry/mass spectrometry (LC/ESI/MS/MS) were used for both G-27550 and GS-31144. The limit of detection was 0.01 ng for G-27550 with GC/MSD, and 0.016 ng when LC/ESI/MS/MS was used for both G-27550 and GS-31144. The LOQ was 0.50 ppb for G-27550 when GC/MSD and the partitioning/SPE sample preparation procedure were used, and 1.0 ppb for the SPE only sample preparation procedure. The LOQ was 1.0 ppb for both analytes when LC/ESI/MS/MS was used.  相似文献   

9.
The capabilities and limitations of 384-well formatted sample preparation technologies applied to regulated bioanalysis were evaluated by developing two assays for the simultaneous quantitation of lopinavir and ritonavir, the active ingredients of Kaletra. One method used liquid-liquid extraction (LLE), and the other used solid-phase extraction (SPE). The steps and apparatuses employed by the two methods covered most of those used for bioanalysis. Briefly, the previously validated 96-well formatted assays were adapted to the 384-format with minor modifications. Because the wells of a 384-well plate are clustered together, cross-contamination between adjacent wells was evaluated critically, along with sensitivity, assay throughput, and ruggedness. Samples (35 microL) containing plasma samples (15 microL), internal standard (10 microL), and sodium carbonate (0.5 M, 10 microL to basify the sample) were placed in a 384-well microtiter plate that may contain saquinavir or amprenavir as contamination markers. For LLE preparation, the samples were placed in a deep 384-well plate (300-microL well volume) and extracted with 150 microL of ethyl acetate. Approximately 50 microL of the extracts were removed from each well after phase separation for analysis. For SPE preparation, the fortified samples were transferred to a 384-formatted SPE plate (C18, 5 mg packing). The extracts were eluted from the plate with basified 2-propanol. The LLE or SPE extracts were dried and reconstituted for column-switching high-performance liquid chromatography with tandem mass spectrometric detection (HPLC/MS/MS). The lower limit of quantitation and the assay range were the same as the 96-well formatted assay. If combined with appropriate automation, sample preparation in the 384-well format would be up to five times more efficient than the 96-well format.  相似文献   

10.
A rapid, specific and sensitive liquid chromatography tandem mass spectrometry (LC–MS/MS) method was developed for the determination of penciclovir in human plasma. The method involved simple, one‐step SPE procedure coupled with a C18, 75 × 4.mm, 3µm column with a flow‐rate of 0.5 mL/min, and acyclovir was used as the internal standard. The Quattro Micro mass spectrometry was operated under the multiple reaction‐monitoring mode using the electrospray ionization technique. Using 250 µL plasma, the methods were validated over the concentration range 52.555–6626.181 ng/mL, with a lower limit of quantification of 52.55 ng/mL. The intra‐ and inter‐day precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a clinical pharmacokinetic study in human volunteers. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
A radioimmunoassay is described that measures budesonide in plasma after solid-phase extraction (SPE/RIA) of the analyte. The performance of the assay was compared with that of a selective LC/MS method. The limit of quantitation of budesonide determined for the LC/MS and SPE/RIA assay was 50 pg/mL and 120 pg/mL, respectively. Based on quality control samples, a higher variability was observed for the SPE/RIA (CV between 4.5 and 23.0%) than for the LC/MS method (CV between 7.5 and 12.5%). Plasma samples obtained from healthy volunteers after administration of budesonide rectal foam were assayed by both methods. In a subset of samples, these results were compared with those measured by direct RIA to evaluate the selectivity of two assays. About two times higher budesonide levels were measured with the direct RIA (lacking the extraction step), presumably because of cross-reactivity with budesonide metabolites, indicating that the extraction step in SPE/RIA is necessary for selectivity. Both SPE/RIA and LC/MS methods were found to be selective, sensitive and suitable for pharmacokinetic studies. Results obtained from the two methods were compared with a number of statistical methods. Ratios of results obtained for the clinical samples were close to 1 (ratio LC-MS/ SPE/RIA = 0.98 +/- 0.27). Linear regression indicated a slope of 1.17 +/- 0.0378. The concordance correlation (r = 0.91) indicated that the agreement between both methods was fair while the Bland-Altman plot indicated that the agreement was less pronounced at higher concentrations (1-3 ng/mL). In summary, the results confirm that the SPE/RIA is an alternative to HPLC/MS and that among the statistical methods tested the concordance correlation analysis was judged to be the most informative test to assess the comparability of two methods.  相似文献   

12.
The comparison of solid phase extraction(SPE) for the preconcentration and isolation of polyphenols in tobacco samples was carried out by ultra-high performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) and multivariate analysis.Several adsorbing materials of SPE(C18,NH2,SAX and OASIS) were investigated.It was found that the C18 and OASIS cartridges can not only speed up the purification process,but also simplify the SPE operation.A UPLC/MS/MS was used for the determination of polyphenols ...  相似文献   

13.
A sensitive and entirely automated solid-phase extraction/liquid chromatography/electrospray ionization tandem mass spectrometric (SPE/LC/ESI-MS/MS) method was developed and validated for the determination of eserine N-oxide (ENO), a cholinesterase inhibitor-like physostigmine in human plasma, for use in pharmacokinetic studies. ENO is light-sensitive and the use of a fully on-line process increased the reliability of the assay. Plasma samples previously mixed with neostigmine bromide to prevent in vitro degradation, and tacrine as internal standard (IS), were directly injected into the SPE/LC/ESI-MS/MS system. MS software piloted the overall system. MS/MS detection of ENO and the IS was performed in the positive ion ESI mode using multiple reaction monitoring. The linear calibration curve for ENO ranged from 25 pg ml(-1) to 12.5 ng ml(-1). The limit of quantitation was 25 pg ml(-1) with 250 microl of plasma injected. Precision, accuracy and stability tests were within the acceptable range and just one analyst is required to analyze 50 unknown samples a day five days per week, from the preparation of the samples (i.e. thawing and centrifugation) to data processing. A pilot pharmacokinetic study in three healthy volunteers treated with 4.5 mg of ENO (Génésérine3((R))) showed that the method was suitable for pharmacokinetic studies in humans.  相似文献   

14.
Bioanalytical methods using automated 96-well solid-phase extraction (SPE) and liquid chromatography with electrospray tandem mass spectrometry (LC/MS/MS) are widely used in the pharmaceutical industry. SPE methods typically require manual steps of drying of the eluates and reconstituting of the analytes with a suitable injection solvent possessing elution strength weaker than the mobile phase. In this study, we demonstrated a novel approach of eliminating these two steps in 96-well SPE by using normal-phase LC/MS/MS methods with low aqueous/high organic mobile phases, which consisted of 70-95% organic solvent, 5-30% water, and small amount of volatile acid or buffer. While the commonly used SPE elution solvents (i.e. acetonitrile and methanol) have stronger elution strength than a mobile phase on reversed-phase chromatography, they are weaker elution solvents than a mobile phase for normal-phase LC/MS/MS and therefore can be injected directly. Analytical methods for a range of polar pharmaceutical compounds, namely, omeprazole, metoprolol, fexofenadine, pseudoephedrine as well as rifampin and its metabolite 25-desacetyl-rifampin, in biological fluids, were developed and optimized based on the foregoing principles. As a result of the time saving, a batch of 96 samples could be processed in one hour. These bioanalytical LC/MS/MS methods were validated according to "Guidance for Industry - Bioanalytical Method Validation" recommended by the Food and Drug Administration (FDA) of the United States.  相似文献   

15.
For the detection of anabolic steroid residues in bovine urine, a highly sensitive liquid chromatographic/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method was developed using both positive and negative ionization. For four compounds the ESI mode was not sensitive enough and gas chromatographic/mass spectrometric GC/MS detection was therefore still necessary as a complementary method. The sample clean-up consisted of solid-phase extraction (SPE) on a C(18) column followed by enzymatic hydrolysis and a second solid-phase extraction on a combination of a C(18) and a NH(2) column. After this last SPE clean-up, the eluate was split into two equal aliquots. One aliquot was further purified and after derivatization used for GC/MS analysis. The other aliquot was analyzed with LC/MS/MS in both ESI+ and ESI- modes. The method was validated according to the European Commission Decision 2002/657/EC. Decision limits (CCalpha) were between 0.16 and 1 ng ml(-1) for the compounds detected with the LC/MS/MS method. The developed method is used in routine analysis in our laboratory.  相似文献   

16.
A method based on solid-phase extraction (SPE) and capillary zone electrophoresis-tandem mass spectrometry (CZE-MS/MS) is described for the separation and determination of six cytokinin nucleotides in coconut water. The best CZE separation for the six cytokinin nucleotide standards was achieved using a 25 mM ammonium formate/formic acid buffer (pH 3.8) and 2% (v/v) methanol with an applied gradient separation voltage (25 kV for 32 min, and then a linear gradient to 30 kV in 5 min, finally 30 kV to the end of separation) in less than 60 min. MS/MS with multiple reaction monitoring (MRM) detection was carried out to obtain sufficient selectivity and sensitivity for the cytokinin nucleotides. The combined use of on-line sample stacking and CZE-MS/MS achieved limits of detection (LODs) in the range of 0.06-0.19 microM for the six cytokinin nucleotides at a signal-to-noise ratio of 3. Furthermore, a novel dual-step SPE procedure was developed for the pre-concentration and purification of cytokinin nucleotides using Oasis HLB and Oasis MAX cartridges. The recoveries of the cytokinin nucleotides after the dual-step SPE were in the range of 44-71%. The combination of off-line SPE, on-line sample stacking and CZE-MS/MS approach was successfully applied to screen for endogenous cytokinin nucleotides present in coconut water sample. trans-Zeatin riboside-5'-monophosphate (ZMP) was detected and quantified in coconut water by CZE-MS/MS after SPE and on-line sample stacking.  相似文献   

17.
The simultaneous analysis of aflatoxins B1, G1, B2, G2 and ochratoxin A in beer was carried out by ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS). Mycotoxins were extracted, purified and concentrated from the beer sample in one step using a solid-phase extraction (SPE) cartridge that contained a polymeric sorbent. Optimization of different parameters, such as type of SPE sorbent, type and amount of wash solvent and pH of the sample, was carried out. The mobile phase consisted of a gradient of methanol + water (0.1% HCOOH) and a reversed-phase C18 column was used for the separation. The mass spectrometer used an electrospray ionization source operated in the positive mode to detect aflatoxins and in the negative mode to detect ochratoxin. UPLC/MS/MS is a rapid and sensitive technique that allows the separation of the five toxins in only 3.2 min. The limit of detection is 1 pg.  相似文献   

18.
A rapid, specific and sensitive LC-MS/MS assay using solid-phase extraction (SPE) for the determination of pravastatin, in human plasma is described. The plasma filtrate obtained after SPE, using a polymer base, a hydrophilic-lipophilic balance (HLB) cartridge, was submitted directly to short-column liquid chromatography-tandem mass spectrometric (LC-MS/MS) assay, with negligible matrix effect on the analysis. For validation of the method, the recovery of the free analytes was compared with that from an optimized extraction method, and the analyte stability was examined under conditions mimicking the sample storage, handling, and analysis procedures. The extraction procedure yielded extremely clean extracts with a recovery of 107.44 and 98.93% for pravastatin and IS, respectively. The intra-assay and inter-assay precisions for the samples at the LLOQ were 3.30 and 7.31% respectively. The calibration curves were linear for the dynamic range 0.5-200 ng/mL with correlation coefficient r > or = 0.9988. The intra- and inter-assay accuracy ranged from 95.87 to 112.40%. The method is simple and reliable with a total run time of 3 min. This novel validated method was applied to the pharmacokinetic (PK) study in human volunteers receiving a single oral dose of 40 mg immediate release (IR) formulation.  相似文献   

19.
We report a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for analyzing bisphenol A (BPA) and its halogenated derivatives. Since only tetrachlorobisphenol A and tetrabromobisphenol A (TBBPA) are commercially available, mono-, di- and trichlorobisphenol A were synthesized and purified in order to be used as analytical standards. This family of compounds was studied using electrospray ionization and an ion trap mass analyzer in order to characterize the new compounds and to propose fragmentation pathways. Multi-stage mass spectrometry was used to confirm the genealogical relationship between the ions. Some product ions were traced from MS/MS to MS(4) and the labelled compounds BPA-d(16) and TBBPA-(13)C(12) were used to assign some product ion structures. In general, the deprotonated molecule [M--H](-) loses a methyl and/or a halogen group during both MS/MS and MS(3), while the neutral loss of CO was also observed in MS(3) spectra. We selected the most intense and characteristic MS/MS transitions for LC/MS/MS analysis. LC separation was performed in a reversed-phase column; methanol/water (no additives) was used as the mobile phase in gradient elution mode; and BPA-d(16) was chosen as the internal standard. Solid-phase extraction (SPE) was used to pre-concentrate and to clean up water samples. The SPE LC/MS/MS method allows BPA and its halogenated derivatives to be detected at a few parts-per-billion (ppb) in surface water.  相似文献   

20.
The employment of chemical weapons by rogue states and/or terrorist organizations is an ongoing concern in the United States. The quantitative analysis of nerve agents must be rapid and reliable for use in the private and public sectors. Current methods describe a tedious and time‐consuming derivatization for gas chromatography–mass spectrometry and liquid chromatography in tandem with mass spectrometry. Two solid‐phase extraction (SPE) techniques for the analysis of glyphosate and methylphosphonic acid are described with the utilization of isotopically enriched analytes for quantitation via atmospheric pressure chemical ionization–quadrupole time‐of‐flight mass spectrometry (APCI‐Q‐TOF‐MS) that does not require derivatization. Solid‐phase extraction‐isotope dilution mass spectrometry (SPE‐IDMS) involves pre‐equilibration of a naturally occurring sample with an isotopically enriched standard. The second extraction method, i‐Spike, involves loading an isotopically enriched standard onto the SPE column before the naturally occurring sample. The sample and the spike are then co‐eluted from the column enabling precise and accurate quantitation via IDMS. The SPE methods in conjunction with IDMS eliminate concerns of incomplete elution, matrix and sorbent effects, and MS drift. For accurate quantitation with IDMS, the isotopic contribution of all atoms in the target molecule must be statistically taken into account. This paper describes two newly developed sample preparation techniques for the analysis of nerve agent surrogates in drinking water as well as statistical probability analysis for proper molecular IDMS. The methods described in this paper demonstrate accurate molecular IDMS using APCI‐Q‐TOF‐MS with limits of quantitation as low as 0.400 mg/kg for glyphosate and 0.031 mg/kg for methylphosphonic acid. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   