首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Analytical letters》2012,45(2):268-279
Estragole, a volatile phenylpropanoid contained in a variety of edible herbs, has been demonstrated to be genotoxic and carcinogenic, and its addition as a flavoring substance to foodstuffs has been banned by the regulatory bodies of the European Union. Fast and accurate analytical methods for its determination in herbs are thus necessary to assess the dietary exposure of this substance in humans and, in particular, to sensitive groups. In the present study, headspace solid-phase microextraction (HS-SPME) combined with gas chromatography–mass spectrometry (GC–MS) was applied for determination of estragole in infusions from different widely used commercial herbal teas based on Foeniculum vulgare (fennel) seeds. The optimized HS-SPME extraction conditions involved the use of a polydimethylsiloxane fiber exposed to the herbal infusion for 20 min at 50°C followed by GC–MS analysis. The method was fully validated for linearity, sensitivity, accuracy, and precision and applied to real samples; the level of estragole in infusions of commercial fennel seed teas was found to be within 50–250 µ`?1.  相似文献   

2.
Feng  Di  Liu  Luo  Zhao  Liyuan  Zhou  Qingfeng  Tan  Tianwei 《Chromatographia》2011,74(11):817-825

Nitrosamines which have been detected in various latex products are carcinogens. The method for determination of volatile nitrosamines in latex products was developed using a combination of headspace solid phase micro-extraction (HS-SPME) and gas chromatography–mass spectrometry (GC–MS). A carboxen/polydimethylsiloxane (CAR/PDMS) fiber was used for HS-SPME involving the following variables: (1) agitation conditions, (2) extraction temperature (3) extraction time, and (4) salt concentration. The instrument performances of three detection systems including GC combined thermal energy analyzer, nitrogen chemiluminescence detector and MS were evaluated. The agitation conditions including magnetic stirring and ultrasonication were investigated by the comparison of extraction efficiency of HS-SPME for nitrosamines. Obtained optimal detection conditions of nitrosamines were HS-SPME at 45 °C for 60 min assisted with magnetic stirring and saturated NaCl followed by GC–MS. To evaluate this method performance, the commercial products including eleven latex products (gloves, balloons and condoms) and four liquid silicone nipples were analyzed with the method. The results revealed that the method is suitable for simple and effective determination of nitrosamines in latex products. The advantage of this HS-SPME–GC–MS method is simple treatment, fast analysis, adequate sensitivity and without organic solvent.

  相似文献   

3.
A rapid and simple procedure for the determination of antioxidants and preservatives in cosmetics has been developed utilizing solid-phase microextraction combined with GC–MS. A silica fiber coated with polyacrylate provided the highest extraction efficiency. Detection limits in the range from 0.4 to 8.5 ng mL−1 were obtained. Linearity is over a wide range from 1 to 2,000 ng mL−1 with a relative standard deviation under 16%. Cosmetic from a local supermarket were analysed for antioxidants and preservatives to demonstrate the effectiveness of the proposed method. The concentration of antioxidants and preservatives determined was 20–1,218 μg g−1 for methylparaben and 5–3,779 μg g−1 for propylparaben.  相似文献   

4.
Levels of nicotine higher than the maximum residue level were detected in edible mushrooms. Analyses of self-collected and purchased dried mushrooms were performed with a QuEChERS approach. A small amount (2.5 g) of dried sample matrix was mixed with 5 mL sodium hydroxide solution, 2.5 g of sodium sulfate/sodium chloride mixture (4:1) and 5 mL ethyl acetate. The organic phase was cleaned by using dispersive solid-phase extraction and analysed by GC–MS–MS. The linear range of the method was 0.01–10.00 mg kg?1 and the limit of detection 0.006 mg kg?1 on dry weight basis by using EURACHEM method.  相似文献   

5.
6.
This article describes a gas chromatography–mass spectrometry (GC–MS) method for the determination of flurbiprofen in pharmaceutical preparations. The method is based on the derivatization of flurbiprofen with N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA). For GC–MS, electron ionization mode (EI = 70 eV) and selected ion monitoring (SIM) mode were used for quantitative analysis (m/z 180 for flurbiprofen). Calibration curve was linear between the concentration range of 0.25–5.0 μg/mL. Intra- and inter-day precision values for flurbiprofen were less than 3.64, and accuracy (relative error) was better than 2.67%. The mean recovery of flurbiprofen was 99.4% for pharmaceutical preparations. The limits of detection and quantification of flurbiprofen were 0.05 and 0.15 μg/mL, respectively. No interference was found from tablet excipients at the selected assay conditions. Also, the method was applied for the quality control of five commercial flurbiprofen dosage forms to quantify the drug and to check the formulation content uniformity.  相似文献   

7.
This paper presents the development, optimization and validation of a methodology to determine nine key steroid hormones (viz. pregnenolone, progesterone, dehydroepiandrosterone, androstenedione, testosterone, dihydrotestosterone, estrone, 17α-estradiol and 17β-estradiol) expressed in the steroidogenesis in biological fluids. The analytical method allows for the determination of steroid hormones in blood plasma and serum down to 0.08–0.16 ng/mL for estrogens, 0.20–0.36 ng/mL for androgens and 0.36–0.43 ng/mL for progestagens. These limits of detection were obtainable using a two-step solid-phase clean-up for fractionation and elimination of interfering lipids (fatty acids, phospholipids, glycerides and sterols) from the steroid hormones. The accuracy of the method was 50–112% in the range 0.10 to 2.00 ng/mL.  相似文献   

8.
Water contamination due to the wide variety of pesticides used in agriculture practices is a global environmental pollution problem. Analytical methods with low quantification limits are necessary. The application of a new extraction technique, solvent drop microextraction (SDME), followed by gas chromatography with a nitrogen-phosphorus detector, was assessed for determining carbamates and organophosphorus pesticides in natural water. Experimental parameters which control the performance of SDME such as selection of microextraction solvent, optimization of organic drop volume, effects of sample stirring, salt addition, and, finally, sorption time profiles were studied. Once SDME was optimized, analytical parameters such as linearity (r 2>0.99), precision (<13%), and detection limits (0.2 to 5 μg/L), plus matrix effects were evaluated (no matrix effects were found). SDME is a dynamic technique able to extract pesticides from water in 14 min; the use of organic solvents and water samples for SDME is negligible compared to other extraction techniques.  相似文献   

9.
The aim of the present study was to develop a chromatographic method for the analysis of atorvastatin, o- and p-hydroxyatorvastatin (acid and lactone forms) in human plasma after administration of atorvastatin at the lowest registered dose (10 mg) in clinical studies. Sample preparation was performed by solid-phase extraction and was followed by separation of the analytes on an HPLC system with a linear gradient and a mobile phase consisting of acetonitrile, water and formic acid. Detection was achieved by tandem mass spectrometry operated in the electrospray positive ion mode. Validation of the method for the compounds for which reference compounds were available (acid forms of atorvastatin, o- and p-hydroxyatorvastatin) showed linearity within the concentration range (0.2–30 ng/ml for atorvastatin acid and p-hydroxyatorvastatin acid, and 0.5–30 ng/ml for o-hydroxyatorvastatin acid) (r20.99, n=5 for all analytes). Accuracy and precision (evaluated at 0.5, 3 and 30 ng/ml for atorvastatin, p-hydroxyatorvastatin and 1, 3 and 30 ng/ml for o-hydroxyatorvastatin) were both satisfactory. The detection limit was 0.06 ng/ml for atorvastatin and p-hydroxyatorvastatin, and 0.15 ng/ml for o-hydroxyatorvastatin. The method has been successfully applied in a clinical study where atorvastatin, o- and p-hydroxyatorvastatin (both acid and lactone forms) could be detected in a 24-h sampling interval after administration of the lowest registered dose of atorvastatin (10 mg) for one week.  相似文献   

10.
Musty and earthy odors dramatically influence the esthetic quality and consumer acceptability of drinking water. This study was conducted to obtain a sensitive method for simultaneous analysis of seven odors, including geosmin (GSM), 2-methylisoborneol (2-MIB), 2-isopropyl-3-methoxy pyrazine (IPMP), dimethyl trisulfide (DMTS), 2,4,6-trichloroanisole (2,4,6-TCA), β-cyclocitral, and β-ionone, in water by applying headspace solid phase micro-extraction coupled to gas chromatography with mass spectrometry. Moreover, the proposed method was applied to obtain preliminary understanding of the levels of these odorants in purified water among various brands in the world, and to try to find out the potential causes when the odorants appeared in purified water. The target compounds could be separated and analyzed effectively within 23 min, and the GSM and DMTS could be detected in all brands of chosen countries, while the IPMP, β-ionone and 2,4,6-TCA cannot be observed in the above brands.  相似文献   

11.
A rapid method was developed for the determination of pentachloronitrobenzene (PCNB) and its metabolites pentachloroaniline, pentachlorothioanisole residues in ginseng. Extraction and clean-up were carried out in a single step and analysis was accomplished by gas chromatography–mass spectrometry with multiple reaction monitoring. The main parameters affecting extraction yield and selectivity, such as type and amount of dispersant material, clean-up co-sorbent and extraction solvent were evaluated. The best results were obtained using 1 g ginseng, 2 g florisil as dispersant sorbent, 0.5 g neutral alumina as clean-up co-sorbent, and subsequent extraction with 10 mL acetone–n-hexane (5:5, v/v) with assisted sonication and repeated with another 5 mL of the same solvent mixture. The method was validated by analysis of ginseng samples fortified at different concentration levels (0.01–0.10 mg kg?1). Average recoveries (n = 5) ranged from 85 to 95% with relative standard deviation between 2.5 and 11.2%. Spiked blank samples were used as standards to counteract the matrix effect observed in the chromatographic determination. The detection limits ranged from 0.2 to 0.9 µg kg?1 in ginseng. The method was applied to the analysis of PCNB and its metabolite residues in commercial ginseng samples.  相似文献   

12.
Sucralose (1,6-dichloro-1,6-dideoxy-β-d-fructofuranosyl-4-chloro-4-deoxy-α-d-galactopyranoside) is a high-intensity non-nutritive sweetener derived from sucrose. Determination of sucralose in food is important to ensure consistent product quality. The authors have developed a new method for determination of sucralose. The sucralose was converted into its trimethylsilyl (TMS) ether and qualitative and quantitative analysis were achieved by GC–MS and GC–FID, respectively, using myo-inositol ester as the internal standard. A good linear relationship between response and amount of sucralose TMS ether was obtained in the range 0.005–0.06 mg mL?1 (r = 0.9994). The detection limit was 0.25 ng.  相似文献   

13.
Sunflower agriculture is an important subsector that plays a key role in the economy of Turkey, contributing 1.38 million tonnes. The aim of this study is to investigate the levels of imidazolinone (IMI) group herbicides in Thrace Region, Turkey. In particular, we aimed to determine the residue levels of imazamox, a herbicide used in sunflower production in Thrace Region, in soil, different parts of plant, and seed. Five herbicides were identified in sunflower samples using solid–liquid extraction with gas chromatography–electrospray ionization mass spectrometry (GC–EI–MS) on single-quadruple instruments in selected ion monitoring (SIM) mode. The optimized conditions were found to be mobile-phase flow rate of 1 mL min?1 and injection volume of 3 μL in programmed temperature vaporization (PTV) solvent vent mode. The recovery of imazamox, imazaquin, imazethapyr, imazapyr, and imazapic from sunflower plant and soil was 89 and 99, 104 and 105, 92 and 93, 96 and 92, and 99 and 96%, respectively.  相似文献   

14.
15.
Li  Yonggang  Chen  Ziliang  Zhang  Rui  Luo  Ping  Zhou  Yan  Wen  Sheng  Ma  Meihu 《Chromatographia》2016,79(17):1165-1175

A quick, easy, cheap, rugged, effective, and safe (QuEChERS)-based method has been validated for the extraction of 42 pesticides and herbicides including organophosphorus pesticides (OPPs), carbamate pesticides (CBs), herbicides (HBs), organochlorine pesticides (OCPs), and synthetic pyrethroid pesticides (PYRs) from chicken eggs. The QuEChERS-based extraction procedure was followed by cleanup steps using C18 and primary secondary amine sorbents. The supernatant was analyzed by ultra-high performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) and gas chromatography–mass spectrometry (GC–MS). The OPPs, CBs, and HBs were quantified by UHPLC–MS/MS, while the OCPs and PYRs were detected by GC–MS. The limits of quantification ranged from 0.01 to 8.5 μg kg−1, and the analyte recoveries were in the range of 64.9–123.2 %. Furthermore, the repeatabilities (intra-day and inter-day) were good, and linear matrix-matched calibration curves were obtained. Acetochlor was identified in concentrations ranging from 0.27 to 0.44 μg kg−1 in four samples from 80 chicken eggs. The method was successfully demonstrated for the fast and reliable analysis of pesticides and herbicides in chicken egg samples.

  相似文献   

16.
A miniaturized QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Save) approach combined with gas chromatography–tandem mass spectrometry (GC–MS/MS) has been developed for the simultaneous determination of nine pesticides (Cyflufenamide, Difenoconazole, Dimethomorph, Fluopicolide, Fluopyram, Metrafenone, Myclobutanil, Quinoxyfen, and Tebuconazole) in insects, snails, and spiders. In contrast to the original QuEChERS approach, only 500 mg of dried and homogenized sample matrix, mixed with 1.0 mL ethyl acetate and 250 mg MgSO4:NaCl (4:1), is required for this novel “micro-QuEChERS” protocol. The organic phase was cleaned using dispersive solid-phase extraction (dSPE) with 75 mg MgSO4:PSA sorbent (4:1). The method was validated according to SANCO/12571/2013 and applied to real samples (n = 7). Fluopicolide was the only detectable pesticide in real samples from vineyards. In two samples, the Fluopicolide levels were between the determined LOD and LOQ (0.15–1.00 mg kg?1), and in one sample a concentration of 1.68 mg kg?1 was detected.  相似文献   

17.
Shen  Jianzhong  Zhang  Suxia  Wu  Congming  Jiang  Haiyang  Wang  Zhanhui  Cheng  Linli 《Chromatographia》2010,71(1-2):163-165

A method was developed to simultaneously detect six resorcylic acid lactones in feed by GC–MS. Samples were extracted with methanol followed by a two step liquid–liquid extraction and an HLB SPE clean-up. The samples were derivatized with BSTFA + TMCS (99/1; v/v) and determined by GC–MS. For all analytes, the ranges of recoveries were 81.2–98.2%, with RSDs of 3.2–15.2%, and the LODs were 0.2–0.6 μg kg−1.

  相似文献   

18.
We report on a method for the determination of twelve herbicides using solid–liquid–solid dispersive extraction (SLSDE), followed by dispersive liquid-liquid micro-extraction (DLLME) and quantitation by gas chromatography with triple quadrupole mass spectrometric detection. SLSDE was applied to the extraction of herbicides from tobacco samples using multi-walled carbon nanotubes (MWCNTs) as clean-up adsorbents. The effect of the quantity of MWCNTs on SLSDE, and of type and volume of extraction and disperser solvents and of salt effect on DLLME were optimized. Good linearity is obtained in the 5.0 - 500 μg kg?1 concentration range, with regression coefficients of >0.99. Intra-day and inter-day repeatability, expressed as relative standard deviations, are between 3 and 9 %. The recoveries in case of herbicide-spiked tobacco at concentration levels of 20.0, 50.0 and 100.0 g kg?1 ranged from 79 to 105 %, and LODs are between 1.5 and 6.1 μg kg?1. All the tobacco samples were found to contain butralin and pendimethalin at levels ranging from 15.8 to 500.0 μg kg?1.
Figure
Schematic diagram of herbicide extraction from tobacco samples by SLSDE-DLLME procedures. (a) sample solution containing herbicide and 10 mL acetonitril, (b) MWCNTs cleanup, (c) extract mixed with water, (d) addition of 100 μL of extraction solvent(chloroform) into mixed solution, (e) vortex mixer for 1 min, (f) phase separation after centrifugation. ? A method for analysis of 12 herbicides in tobacco samples was developed. ? MCNTs were used as sorbent, DLLME was further applied to purification and enrichment.. ? Butralin and pendimethalin were found in all tobacco samples.  相似文献   

19.
A rapid and sensitive method for determination of methyl nonyl ketone in rat plasma was developed based on GC–MS. The analyte and internal standard, propyl p-hydroxybenaoate, were extracted from plasma with methyl tert-butyl ether and then separated by an HP-5MS capillary analytical column (30 m × 0.25 mm, 0.25 µm) and determined by a quadrupole mass spectrometer detector operated under EI ionization and selected ion monitoring mode. Excellent linearity was found to be from 5.0 to 1,000 ng mL?1 with a lower limit of quantitation of 5.0 ng mL?1. The accuracy was between 96.0 and 106.3%, and the intra- and inter-day precision and accuracy values were found to be within the assay variability criteria limits according to the FDA guidelines. The developed method was successfully applied to the pharmacokinetic study of methyl nonyl ketone, a typical component in the traditional Chinese medicine Houttuynia cordata injection, in rats after a single oral dose of 100 mg kg?1 and peritoneal injection dose of 5 mg kg?1, respectively.  相似文献   

20.
Isotope-dilution analysis in combination with GC-ICP-MS detection has been applied to the determination of butyltin species in environmental samples. Different spikes containing the isotopically labeled butyltin species have been synthesized in the laboratory after optimization of the reaction conditions. The isotopic compositions of the tin species in the different spike solutions were determined by GC-ICP-MS after derivatization by aqueous ethylation with sodium tetraethylborate. Reverse isotope-dilution analysis was used for quantitation of the spike solutions by means of natural MBT, DBT, and TBT standards. The mixed spikes were used for simultaneous analysis of MBT, DBT and TBT in the certified reference materials, PACS-2, CRM 462, and CRM 646, with satisfactory results. The excellent agreement of the different speciation results obtained by use of the different spikes is a good indicator of the precision, accuracy, and reliability which can be achieved by using isotope-dilution analysis for trace metal speciation.Application of a double spike containing (119)Sn-enriched MBT (79.7 At%), (118)Sn-enriched DBT (86.7 At%), and (119)Sn-enriched TBT (83.1 At%) also enabled evaluation of the conditions resulting in quantitative extraction of the species from the solid matrix, in combination with possible alterations depending on the different extraction procedures used (mechanical shaking, ultrasounds, and microwaves). Mathematical equations used for this purpose computed the correct species concentrations directly and, additionally, the decomposition factors (from TBT to DBT and from DBT to MBT) after precise measurement of the (119)Sn/(120)Sn and (118)Sn/(120)Sn ratios for all butyltin species by GC-ICP-MS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号