共查询到20条相似文献,搜索用时 15 毫秒
1.
The fatty acyl esters of L-carnitine (acylcarnitines) are useful biomarkers for the diagnosis of some inborn errors of metabolism analyzed by liquid chromatography/tandem mass spectrometry. In this study the acylcarnitines were analyzed by atmospheric pressure thermal desorption chemical ionization using a commercial tandem mass spectrometer (APTDCI-MS/MS). The method is based on the precursor ion scan mode determination of underivatized acylcarnitines desorbed from samples by a hot desolvation gas flow and ionized by a corona pin discharge. During desorption/ionization step the temperature induces the degradation of acylcarnitines; nevertheless, the common fragment to all acylcarnitines [MH-59](+) is useful for analyzing their profile. APTDCI parameters, including angle of collection and incidence, gas flows and temperatures, were optimized for acylcarnitines. The experiments were performed drying 2 microL of an equimolar mixture of acylcarnitine standards on a glass slide. The specificity was evaluated by comparing product ion spectra and the precursor ion spectra of 85 m/z of acylcarnitines obtained by the APTDCI method and by electrospray ionization flow injection analysis (ESI-FIA). The method was also employed to analyze acylcarnitines extracted from a pathological dried blood spot and a control. The method enables analysis of biological samples and recognition of some acylcarnitines that are diagnostic markers of inherited metabolic diseases. The intrinsic high-throughput analysis of the ambient desorption ionization methods offers a new opportunity either for its potential application in clinical chemistry and for the expanded screening of some inborn errors of metabolism. 相似文献
2.
Peng S Ahlmann N Kunze K Nigge W Edler M Hoffmann T Franzke J 《Rapid communications in mass spectrometry : RCM》2004,18(16):1803-1808
The desorption of an analyte by a continuous wave diode laser from a porous surface of a thin-layer plate covered with a graphite suspension is presented. The thermally desorbed analyte molecules are ionized in the gas phase by a corona discharge at atmospheric pressure. Therefore, both essential processes--the desorption and the ionization of analyte molecules, which are often performed in one step--are separated. The target preparation is easy and fast since no additional extraction process is required. The mass spectrometric background signal was mostly limited to the low mass range showing no interference with typical compounds of interest. In this study, the calmative and antihypertensive drug reserpine was chosen as model analyte, which is often used for specification of mass spectrometers. No fragmentation was observed because of efficient collisional cooling under atmospheric pressure. The influence of diode laser power and the composition of the graphite suspension were investigated, and a primary optimization was performed. 相似文献
3.
Glyburide (glibenclamide) is widely prescribed in the treatment of Type II diabetes. A validated liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry (LC/APCI-MS/MS) method for the determination of glyburide is reported. The method uses a stable isotope labeled glyburide as the internal standard. Subsequent to acetonitrile protein precipitation, the supernatant was directly (unfiltered) injected onto the LC column (retention time approximately 3 min) for analysis. A lower limit of quantification (LLOQ) of 1.01 ng/mL was attained for the human plasma assay. The method was fast, specific, and exhibited excellent ruggedness. It was successfully applied to the analysis of clinical samples from patients dosed with glyburide. 相似文献
4.
Eiceman GA Bergloff JF Rodriguez JE Munro W Karpas Z 《Journal of the American Society for Mass Spectrometry》1999,10(11):1157-1165
Atmospheric pressure chemical ionization (APCI)-mass spectrometry (MS) for fluorinated phenols (C6H5-xFxOH Where x = 0-5) in nitrogen with Cl- as the reagent ion yielded product ions of M Cl- through ion associations or (M-H)- through proton abstractions. Proton abstraction was controllable by potentials on the orifice and first lens, suggesting that some proton abstraction occurs through collision induced dissociation (CID) in the interface region. This was proven using CID of adduct ions (M Cl-) with Q2 studies where adduct ions were dissociated to Cl- or proton abstracted to (M-H)-. The extent of proton abstraction depended upon ion energy and structure in order of calculated acidities: pentafluorophenol > tetrafluorophenol > trifluorophenol > difluorophenol. Little or no proton abstraction occurred for fluorophenol, phenol, or benzyl alcohol analogs. Ion mobility spectrometry was used to determine if proton abstraction reactions passed through an adduct intermediate with thermalized ions and mobility spectra for all chemicals were obtained from 25 to 200 degrees C. Proton abstraction from M Cl- was not observed at any temperature for phenol, monofluorophenol, or difluorophenol. Mobility spectra for trifluorophenol revealed the kinetic transformations to (M-H)- either from M Cl- or from M2 Cl- directly. Proton abstraction was the predominant reaction for tetra- and penta-fluorophenols. Consequently, the evidence suggests that proton abstraction occurs from an adduct ion where the reaction barrier is reduced with increasing acidity of the O-H bond in C6H5-xFxOH. 相似文献
5.
Ambient mass spectrometry, pioneered with desorption electrospray ionization (DESI) technique, is of increasing interest in recent years. In this study, a corona discharge ionization source is adapted for direct surface desorption chemical ionization of compounds on various surfaces at atmospheric pressure. Ambient air, with about 60% relative humidity, is used as a reagent to generate primary ions such as H(3)O(+), which is then directed to impact the sample surface for desorption and ionization. Under experimental conditions, protonated or deprotonated molecules of analytes present on various samples are observed using positive or negative corona discharge. Fast detection of trace amounts of analytes present in pharmaceutical preparations, viz foods, skins and clothes has been demonstrated without any sample pretreatment. Taking the advantage of the gasless setup, powder samples such as amino acids and mixtures of pharmaceutical preparations are rapidly analyzed. Impurities such as sudan dyes in tomato sauce are detected semiquantitatively. Molecular markers (e.g. putrescine) for meat spoilage are successfully identified from an artificially spoiled fish sample. Chemical warfare agent stimulants, explosives and herbicides are directly detected from the skin samples and clothing exposed to these compounds. This provides a detection limit of sub-pg (S/N > or = 3) range in MS2. Metabolites and consumed chemicals such as glucose are detected successfully from human skins. Conclusively, surface desorption atmospheric pressure chemical ionization (DAPCI) mass spectrometry, without toxic chemical contamination, detects various compounds in complex matrices, showing promising applications for analyses of human related samples. 相似文献
6.
A new solid phase extraction (SPE) method coupled to a high throughput sample analysis technique was developed for the simultaneous determination of nine selected emerging contaminants in wastewater (atrazine, desethylatrazine, 17β-estradiol, ethynylestradiol, norethindrone, caffeine, carbamazepine, diclofenac and sulfamethoxazole). We specifically included pharmaceutical compounds from multiple therapeutic classes, as well as pesticides. Sample pre-concentration and clean-up was performed using a mixed-mode SPE cartridge (Strata ABW) having both cation and anion exchange properties, followed by analysis by laser diode thermal desorption atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS). The LDTD interface is a new high-throughput sample introduction method, which reduces total analysis time to less than 15 s per sample as compared to minutes with traditional liquid-chromatography coupled to tandem mass spectrometry (LC–MS/MS). Several SPE parameters were evaluated in order to optimize recovery efficiencies when extracting analytes from wastewater, such as the nature of the stationary phase, the loading flow rate, the extraction pH, the volume and composition of the washing solution and the initial sample volume. The method was successfully applied to real wastewater samples from the primary sedimentation tank of a municipal wastewater treatment plant. Recoveries of target compounds from wastewater ranged from 78% to 106%, the limit of detection ranged from 30 to 122 ng L−1 while the limit of quantification ranged from 90 to 370 ng L−1. Calibration curves in the wastewater matrix showed good linearity (R2 ≥ 0.991) for all target analytes and the intraday and interday coefficient of variation was below 15%, reflecting a good precision. 相似文献
7.
8.
9.
Liying Ding Feng Hong Yongzhong Ouyang Rui Chen Shumin Zhou Huanwen Chen Xiang Fang 《Journal of mass spectrometry : JMS》2013,48(9):1042-1049
Molecular images of documents were obtained by sequentially scanning the surface of the document using desorption atmospheric pressure chemical ionization mass spectrometry (DAPCI‐MS), which was operated in either a gasless, solvent‐free or methanol vapor‐assisted mode. The decay process of the ink used for handwriting was monitored by following the signal intensities recorded by DAPCI‐MS. Handwritings made using four types of inks on four kinds of paper surfaces were tested. By studying the dynamic decay of the inks, DAPCI‐MS imaging differentiated a 10‐min old from two 4 h old samples. Non‐destructive forensic analysis of forged signatures either handwritten or computer‐assisted was achieved according to the difference of the contour in DAPCI images, which was attributed to the strength personalized by different writers. Distinction of the order of writing/stamping on documents and detection of illegal printings were accomplished with a spatial resolution of about 140 µm. A Matlab® written program was developed to facilitate the visualization of the similarity between signature images obtained by DAPCI‐MS. The experimental results show that DAPCI‐MS imaging provides rich information at the molecular level and thus can be used for the reliable document analysis in forensic applications. © 2013 The Authors. Journal of Mass Spectrometry published by John Wiley & Sons, Ltd. 相似文献
10.
11.
Fragmentation mechanisms of protonated chalcone and its derivatives with different functional groups were investigated by atmospheric pressure chemical ionization with tandem mass spectrometry (MS/MS). The major fragmentation pathways were loss of the phenyl group from the A or B ring, combined with loss of CO. Losses of H(2)O and CO from the precursor ions of [M+H](+) are proposed to occur via rearrangements. Elimination of water from protonated chalcones was observed in all the title compounds to yield a stable ion but it was difficult to obtain skeletal fragmentation of a precursor ion. Loss of CO was found in the MS/MS spectra of all the compounds except the nitro-substituted chalcones. When the [M+H--CO](+) ion was fragmented in the MS/MS experiments, there were distinctive losses of 15 and 28 Da, as the methyl radical and ethylene, respectively. The ion at m/z 130, found only in the nitro-substituted chalcones, was assigned as C(9)H(6)O by Fourier transform ion cyclotron resonance (FTICR)-MS/MS; m/z 130 is a common fragment ion in the electron ionization (EI) spectra of chalcones. In order to more easily distinguish the constitutional isomers of these chalcones, breakdown curves were produced and these provided strong support in this study. 相似文献
12.
We present the results of studying the effects of temperature and humidity of the reaction medium and the intensity of ultraviolet radiation on the atmospheric pressure chemical ionization of Penthrite. The peculiarities of the ion mobility spectra of this compound obtained by ion mobility spectrometry-tandem mass spectrometry are analyzed. 相似文献
13.
A new technique is presented for the coupling of atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) mass spectrometry with liquid delivery systems. Mass measurements of polymers and peptides are demonstrated using a co-dissolved matrix, e.g. alpha-cyano-4-hydroxycinnamic acid (HCCA). Improvements in terms of sensitivity are achieved by optimizing the shape und control of the exit capillary and by using a laser (355 nm) at a 1 kHz repetition rate. Two calibration experiments promise a good applicability of the presented coupling method for quantitative measurements. The limit of detection achieved so far is 500 nM for peptides in methanol solution containing 25 mM HCCA. 相似文献
14.
The fragmentation behavior of taxoids was studied using electrospray (ESI) and atmospheric pressure chemical ionization (APCI) sources with multi-stage tandem mass spectrometry. In the positive ion mode taxoids gave prominent [M+Na]+ and [M+K]+ ions with the ESI source, and [M+NH4]+ or [M+H]+ ions with the APCI source. The MS/MS fragmentations of ions produced by APCI and ESI sources were very similar. For both sources, the presence of cinnamoyl or benzoyl groups could be characterized by initial losses of 148 or 122 u, respectively, from molecular adduct ions. However, the elimination of cinnamic acid was relatively difficult for the molecular adduct ions formed by APCI, and was comparable in importance to the loss of acetic acid. The other fragments involved losses of CH2CO, CO, and H2O. The 5/7/6 type taxoids underwent characteristic losses of 58 or 118 u from ions produced by both APCI and ESI sources. The fragmentation behavior was remarkably influenced by substitution locations. The elimination of the C-10 benzoyl group was usually the first fragmentation step, while that of the C-2 benzoyl group was relatively difficult. The acetoxyl group at C-7 was more active than those at C-2, C-9, and C-10, which in turn were more active than that at C-4. These fragmentation rules could facilitate the rapid screening and structural characterization of taxoids in plant extracts by high-performance liquid chromatography/mass spectrometry (HPLC/MS). 相似文献
15.
16.
di Donna L Grassi G Mazzotti F Perri E Sindona G 《Journal of mass spectrometry : JMS》2004,39(12):1437-1440
A high-throughput method is presented for the determination of rotenone in contaminated matrices. The procedure involves atmospheric pressure chemical ionization tandem mass spectrometry with a triple-quadrupole instrument and the use as internal standard of a cycloadduct derivative of rotenone itself. The method was applied to the evaluation of the decay of rotenone in olives and olive oil at various times after exposure to the contaminant. 相似文献
17.
Simon Ningsun Zhou Eric J. Reiner Chris Marvin Paul Helm Nicole Riddell Frank Dorman Michelle Misselwitz Li Shen Patrick Crozier Karen MacPherson Ian D. Brindle 《Analytical and bioanalytical chemistry》2010,396(3):1311-1320
Until recently, atmospheric pressure photoionization (APPI) has typically been used for the determination of non-polar halogenated flame retardants (HFRs) by liquid chromatography (LC) tandem mass spectrometry. In this study, we demonstrated the feasibility of utilizing liquid chromatography atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (LC-APCI-MS/MS) for analysis of 38 HFRs. This developed method offered three advantages: simplicity, rapidity, and high sensitivity. Compared with APPI, APCI does not require a UV lamp and a dopant reagent to assist atmospheric pressure ionization. All the isomers and the isobaric compounds were well resolved within 14-min LC separation time. Excellent instrument detection limits (6.1 pg on average with 2.0 μL injection) were observed. The APCI mechanism was also investigated. The method developed has been applied to the screening of wastewater samples for screening purpose, with concentrations determined by LC-APCI-MS/MS agreeing with data obtained via gas chromatography high resolution mass spectrometry. Figure
LC-APCI-MS/MS for analysis of halogenated flame reterdants 相似文献
18.
Lee Chuin Chen Md. Matiur Rahman Kenzo Hiraoka 《Journal of mass spectrometry : JMS》2013,48(3):392-398
Super‐atmospheric pressure chemical ionization (APCI) mass spectrometry was performed using a commercial mass spectrometer by pressurizing the ion source with compressed air up to 7 atm. Similar to typical APCI source, reactant ions in the experiment were generated with corona discharge using a needle electrode. Although a higher needle potential was necessary to initiate the corona discharge, discharge current and detected ion signal were stable at all tested pressures. A Roots booster pump with variable pumping speed was installed between the evacuation port of the mass spectrometer and the original rough pumps to maintain a same pressure in the first pumping stage of the mass spectrometer regardless of ion source pressure. Measurement of gaseous methamphetamine and research department explosive showed an increase in ion intensity with the ion source pressure until an optimum pressure at around 4–5 atm. Beyond 5 atm, the ion intensity decreased with further increase of pressure, likely due to greater ion losses inside the ion transport capillary. For benzene, it was found that besides molecular ion and protonated species, ion due to [M + 2H]+ which was not so common in APCI, was also observed with high ion abundance under super‐atmospheric pressure condition. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
19.
Atmospheric pressure chemical ionization mass (APCI-MS) and tandem mass spectrometry (APCI-MS/MS) is used to probe the mechanism of the Petasis olefination reaction. Oxatitanacycle intermediates 4 were transferred from solution to the gas phase, detected as 4H+ by APCI-MS with characteristic Ti-isotopic patterns, and structurally characterized by APCI-MS/MS. Detection of 4H+, which upon collision activation dissociates to both 3H+ and Cp(2)TiOH+, fully supports the Hughes mechanism as depicted above. [reaction: see text] 相似文献
20.
Nicholas E. Manicke Thomas Kistler Demian R. Ifa R. Graham Cooks Zheng Ouyang 《Journal of the American Society for Mass Spectrometry》2009,20(2):321-325
A newly developed high-throughput desorption electrospray ionization (DESI) source was characterized in terms of its performance in quantitative analysis. A 96-sample array, containing pharmaceuticals in various matrices, was analyzed in a single run with a total analysis time of 3 min. These solution-phase samples were examined from a hydrophobic PTFE ink printed on glass. The quantitative accuracy, precision, and limit of detection (LOD) were characterized. Chemical background-free samples of propranolol (PRN) with PRN-d7 as internal standard (IS) and carbamazepine (CBZ) with CBZ-d10 as IS were examined. So were two other sample sets consisting of PRN/PRN-d7 at varying concentration in a biological milieu of 10% urine or porcine brain total lipid extract, total lipid concentration 250 ng/μL. The background-free samples, examined in a total analysis time of 1. 5 s/sample, showed good quantitative accuracy and precision, with a relative error (RE) and relative standard deviation (RSD) generally less than 3% and 5%, respectively. The samples in urine and the lipid extract required a longer analysis time (2. 5 s/sample) and showed RSD values of around 10% for the samples in urine and 4% for the lipid extract samples and RE values of less than 3% for both sets. The LOD for PRN and CBZ when analyzed without chemical background was 10 and 30 fmol, respectively. The LOD of PRN increased to 400 fmol analyzed in 10% urine, and 200 fmol when analyzed in the brain lipid extract. 相似文献