首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This work reports the development and application of a negative ion mode online LC-ESI-MS method for studying the effect of water deficit on the carbohydrate content of Lupinus albus stems, using a porous graphitic carbon (PGC) stationary phase and an ion trap mass spectrometer. Using this method, separation and detection of several water soluble carbohydrates, ranging from mono-, di-, and oligosaccharides (raffinose, stachyose, and verbascose) to sugar alcohols was achieved in approximately 10 min. This on-line PGC-LC-ESI-MS method shows good linearity with correlation coefficients R(2)>0.99, selectivity, short analysis time, and limits of detection (LOD) ranging from 0.4 to 9 pmol for sugars and 4-20 pmol for sugar alcohols. This PGC-LC-ESI-MS method is sensitive and allowed us to detect even small alterations in carbohydrate levels in L. albus stems that resulted from a mild/early water deficit (nmol g(-1)DW). This paper describes details of our method and its application to the quantitative analysis of water soluble underivatised carbohydrates extracted from L. albus stem tissues that have been subjected to early and severe water deficit conditions, followed by a rewatering period.  相似文献   

2.
Enzymatically digested oligosaccharides of kappa-carrageenans were separated on a porous graphitic carbon (PGC) column and characterised on-line by electrospray ionisation mass spectrometry (ESI-MS). Two different developing ions were applied. Among them ammonium hydrogencarbonate showed more eluting power as it should on normal anion-exchange stationary phases. The oligosaccharides were detected by ESI-MS as fully deprotonated oligosaccharides.  相似文献   

3.
Monolithic columns having long hydrocarbon chains were prepared by in-situ polymerization in capillary fused silica tubing. The capillary columns were coupled with a newly developed carbon fiber electrospray ionization (ESI) emitter for proteomic analysis using sheathless capillary HPLC-ESI mass spectrometry (MS). The sample loading capacity and chromatographic performance of the styrene-based monolithic column, which was prepared by photo-polymerization of octylstyrene (OS) and divinylbenzene (DVB) were compared with that of the methacrylate-based monolithic column composed of lauryl methacrylate (LMA) and ethylene dimethacrylate (EDMA). The sample loading ability of tryptic digested protein in poly-OS (POS)-DVB column was higher than that of poly-LMA (PLMA)-EDMA column, possibly due to the irregular and rugluous surface offering a greater surface area of POS-DVB stationary phase. The POS-DVB column also provided better separation efficiency in the separation of high concentration (10 microg) of tryptic digested albumin bovine serum (BSA). Due to the successful interface of a highly efficient monolithic column and a stable, durable carbon fiber emitter, low femtomole levels of peptides were successfully separated and identified in the presence of large amounts of tryptic digested protein.  相似文献   

4.
A simple and robust method for quantification of zolpidem in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI MS/MS). Es-citalopram was used as an internal standard. Zolpidem and internal standard in plasma sample were extracted using solid-phase extraction cartridges (Oasis HLB, 1 cm3/30 mg). The samples were injected into a C8 reversed-phase column and the mobile phase used was acetonitrile-ammonium acetate (pH 4.6; 10 mm) (80:20, v/v) at a flow rate of 0.7 mL/min. Using MS/MS in the selected reaction-monitoring (SRM) mode, zolpidem and Es-citalopram were detected without any interference from human plasma matrix. Zolpidem produced a protonated precursor ion ([M+H]+) at m/z 308.1 and a corresponding product ion at m/z 235.1. The internal standard produced a protonated precursor ion ([M+H]+) at m/z 325.1 and a corresponding product ion at m/z 262.1. Detection of zolpidem in human plasma by the LC-ESI MS/MS method was accurate and precise with a quantification limit of 2.5 ng/mL. The proposed method was validated in the linear range 2.5-300 ng/mL. Reproducibility, recovery and stability of the method were evaluated. The method has been successfully applied to bioequivalence studies of zolpidem.  相似文献   

5.
Native cyclodextrin-based columns are particularly useful for the analysis of oligosaccharides because the retention of these carbohydrates is based mainly on the hydrogen bonding interactions of oligosaccharide hydroxyl groups with the stationary phase. Thus, the retention time predictably increases with the number of analyte hydroxyl groups, which corresponds to the elongation of the oligosaccharide chain. High-performance liquid chromatography (HPLC) coupled to electrospray ionization (ESI) mass spectrometry (MS) was used for the separation and characterization of underivatized oligosaccharide mixtures. With the limits of detection as low as 50 pg, all individual components of oligosaccharide mixtures (up to 11 glucose units long) were baseline resolved on a Cyclobond I 2000 column and detected using ESI-MS. Low flow rates and narrow I.D. columns increase the ESI-MS sensitivity significantly. The method showed potential usefulness for the sensitive and quick analysis of hydrolysis products of polysaccharides, and for trace levels of individual oligosaccharide or oligosaccharide isomers from biological systems.  相似文献   

6.
建立了鸡组织中聚醚类药物多残留检测的高效液相色谱-电喷雾串联质谱方法。采用甲醇提取鸡组织中的拉沙洛菌素、盐霉素、莫能菌素、甲基盐霉素和马杜霉素,经硅胶柱净化,以乙腈(含0.1%甲酸)-0.1%甲酸水溶液(体积比为97:3)为流动相,Symmetry Shield RP18作为色谱分析柱,多反应监测(MRM)正离子扫描方式进行质谱检测。当5种聚醚类药物的添加水平为鸡肉0.1~1500 μg/kg、鸡肝0.2~4500 μg/kg时,平均回收率为71.6%~99.1%,日内测定的相对标准偏差(RSD)(n=5)为3.2%~10.7%,日间RSD(n=3)为4.6%~14.7%。2种鸡组织中5种聚醚类药物的定量限为0.1~1.0 μg/kg。该方法的灵敏度、准确度和精密度均符合兽药残留分析技术的要求,适用于鸡肉和鸡肝中5种聚醚类药物的多残留检测。  相似文献   

7.
A simple and reliable method using liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) for the determination of tetrodotoxin in the puffer-fish has been developed. The LC separation was performed on a Shodex RSpak NN-414 column (15 cm x 4.6 mm id) using 20 mM ammonium acetate-methanol (75 + 25) as the mobile phase at a flow rate of 0.5 ml min(-1). The positive ionization produced the typical [M + H]+ molecular ion of tetrodotoxin (m/z 320). The calibration graph for tetrodotoxin was rectilinear from 0.01 to 1 microg ml(-1) with selected ion monitoring (SIM). Tetrodotoxin was extracted with 0.1% acetic acid by heating in a boiling water-bath and the extracts were cleaned up on a Bond Elut C18 (500 mg) cartridge. The recoveries of the tetrodotoxin from the puffer-fish fortified at 1 microg g(-1) were 77.7-80.7% and the detection limit was 0.1 microg g(-1) (equivalent to ca. 0.5 mouse units per gram).  相似文献   

8.
刘正才  杨方  余孔捷  林永辉  刘素珍  张琼  苏芝娇 《色谱》2012,30(12):1253-1259
建立了鸡组织中抗病毒类药物多残留检测的液相色谱-电喷雾串联质谱法(LC-ESI-MS/MS)。采用三氯乙酸-乙腈溶液提取鸡组织中的金刚烷胺、金刚乙胺、美金刚、咪喹莫特和吗啉胍,离心过滤后经强阳离子交换柱(SCX)净化,色谱柱Xamide(100 mm×2.1 mm, 5 μm)分离,多反应监测(MRM)正离子扫描方式进行质谱检测。结果表明,鸡组织与鸡肝中5种药物的检出限为0.06~0.30 μg/kg,定量限为0.2~1.0 μg/kg。当5种药物的添加水平为0.2~10.0 μg/kg时,在鸡肉中的平均回收率为72.3%~94.2%,相对标准偏差(RSD)(n=6)为3.5%~11.3%;在鸡肝中的平均回收率为70.8%~92.7%, RSD(n=6)为5.3%~12.6%。该方法选择性好,抗干扰能力强,可作为鸡肉和鸡肝中抗病毒药物残留检测的确证方法。  相似文献   

9.
The fragmentation pattern of 30 compounds belonging to different classes of the lignan family was studied by liquid chromatography-electrospray ionization ion-trap mass spectrometry. On the basis of the observed fragmentation patterns, identification of different types of lignans was achieved. For example, dibenzylbutyrolactone lignans showed a characteristic fragmentation pathway by the loss of 44 Da (CO(2)) from the lactone moiety, whereas dibenzylbutanediols showed a loss of 48 Da by a combined loss of formaldehyde and water from the 1,4-butanediol moiety. Lignan glycosides readily lost the sugar residue to give the parent lignan as their primary product ion. In addition, several compound-specific fragmentations were observed and used for identification of individual compounds.A versatile method for analyses of lignans was developed using LC separation on a C8 column followed by fragmentation and detection of ions produced in the ion trap.  相似文献   

10.
The alcoholic extract of the aerial parts of Hypericum perforatum L. finds wide application because of its antidepressant activity. The extract contains a number of constituents with documented biological activity including chlorogenic acid, a broad range of flavonoids, naphthodianthrones and phloroglucinols. Hyperforin and adhyperforin are the major phloroglucinol constituents found in the lipophilic fraction of the extracts. Since the stability of hyperforin has been shown to be limited, an investigation of the hyperforin degradation products using HPLC-electrospray ionization mass spectrometry and multiple mass spectrometry was undertaken.  相似文献   

11.
High-performance liquid chromatography combined with a UV absorbance detector and electrospray ionization mass spectrometer is used for the simultaneous analysis of moexipril and moexiprilat in biological samples. Moexipril and moexiprilat are determined in samples metabolized by rat and human liver microsomal preparations, and also in rat urine. The calibration curve is linear in the ng/mL and microg/mL concentration range of the injected moexipril.  相似文献   

12.
Unusual amino acids such as beta-methoxytyrosine (beta-MeOTyr), allo-threonine (allo-Thr) and allo-isoleucine (allo-Ile) were derivatized with N-alpha-(2,4-dinitro-5-fluorophenyl)-L-alaninamide (FDAA), 2,3,4,6-tetra-O-acetyl-beta-D-glucopyranosyl isothiocyanate (GITC), (S)-N-(4-nitrophenoxycarbonyl)phenylalanine methoxyethyl ester (S-NIFE), or o-phthalaldehyde/isobutyryl-L-cysteine (OPA-IBLC), and then separated via reversed-phase high-performance chromatography followed by UV and electrospray ionization mass spectrometry detection. FDAA generally showed the highest enantioselectivity but the lowest sensitivity among the chiral derivatizing agents (CDAs) investigated. The detection limit of FDAA-derivatized amino acids was in the low picomolar range. Although the enantioselectivity of FDAA derivatives was generally quite high, its selectivity among beta-MeOTyr isomers was poor. The best separation of beta-MeOTyr stereoisomers was achieved with S-NIFE. Due to the complex relationships between the investigated CDAs, stereochemical analyses using a combination of two or more of the CDAs gave the most reliable results for a given separation problem. In general, the methods described are selective and reliable, and are being applied to the analysis of unusual amino acids as they occur in marine peptides.  相似文献   

13.
Symphytum officinale L. (comfrey) is a medicinal plant commonly used in decoctions and aliments. Besides therapeutic bioactive compounds present in the herb, it is found to contain hepatotoxic pyrrolizidine alkaloids (PAs), such as lycopsamine and others. In the present study, PAs such as lycopsamine, echimidine and lasiocarpine were determined using electrospray liquid chromatography-mass spectrometry (LC-MS) with the method precision (relative standard deviation, RSD) <10%. Detection of lycopsamine, symviridine and their N-oxides could be confirmed with a newly developed method based on HPLC ion-trap and orbitrap MS with electrospray ionization interface. With LC-MS, quantitative analysis of lycopsamine in the botanical extract was carried out. The effect of extraction solvent was optimized by sonication and methanol: H2O (50:50) was selected. Then a rapid method based on pressurized hot water extraction (PHWE) was employed for the extraction of lycopsamine from comfrey followed by the comparison with heating under reflux with the RSD ranging from 2.49% to 19.32%. Our results showed a higher extraction efficiency for heating under reflux compared with PHWE. It was proposed that the lower extraction efficiency for PHWE was attributable to dissolved nitrogen from air which caused the reduction in the solubility of lycopsamine in the compressed hot solvent. In this study, quantitative analysis of PAs in comfrey was demonstrated. In addition, it was found that the use of subcritical water for extractions depended on the physical properties of the dissolved solutes and their tendency to degrade under the chosen extraction conditions.  相似文献   

14.
15.
Liquid chromatography coupled to electrospray mass spectrometry (LC-ES-MS) with positive ion detection was used to determine abamectin in oranges. MS conditions were optimized to achieve maximum sensitivity. The main ion for abamectin was [M+Na]+ at a fragmentor voltage of 180 V. Abundant structural information can be obtained at different fragmentor voltages. The detection limit for the standard solution was 12 pg injected, and good linearity and reproducibility were observed. Abamectin residues were extracted using matrix solid-phase dispersion. Orange samples were homogenized with C18 bonded silica placed onto a glass column and eluted with dichloromethane. Recoveries of the abamectin from oranges fortified with approximately 0.01-10 mg/kg ranged from 94 to 99% with an overall average recovery of 96%. The quantification limit is 0.0025 mg/kg, which means detection limit for this analyte could be set at a few hundred picograms per gram of fruit. The presence in the electrosprayed solution of numerous citrus constituents did not interfere significantly with the ionization process of abamectin. The assay procedure provides a simple, rapid, and sensitive method for monitoring residues in oranges. The method was applied to field treatment orange samples.  相似文献   

16.
Due to the proteomics revolution, multi-dimensional separation and detection instruments are required to evaluate many peptides and proteins in single samples. In this study, electrospray ionization (ESI) ion mobility spectrometry (IMS) was evaluated as an additional separation after HPLC separations. Common HPLC mobile phase compositions (solvents, acid modifiers, and buffers) were assessed for the effect on ESI-IMS response. Up to 5 mM sodium phosphate, a non-volatile buffer, was able to be electrosprayed into the IMS without degradation of the instrumental performance. Due to the rapid separation times of IMS, multiple IMS spectra were obtained within a single HPLC peak. A five-peptide mixture was separated in a capillary HPLC column under isocratic conditions within 3 min. Coelution of two peaks due to non-optimal HPLC conditions occurred and these two peaks could not be distinguished by HPLC with UV detection. In contrast, the single ion mobility chromatograms provided separation of each peptide as well as providing a second degree of analyte identification (HPLC retention time and IMS mobility). Furthermore, IMS-MS analysis of the five peptides and comparison with HPLC retention times showed that each peptide had a unique retention time-ion mobility-mass to charge value. This work showed that IMS could be employed for direct separation and detection of HPLC eluents and also could be combined with HPLC-MS for three unique dimensions of separation.  相似文献   

17.
Due to the presence of a large number of proteins in cell extracts, ion chromatograms of cell extracts obtained by electrospray ionization mass spectrometry (ESI-MS) can be quite complicated. It is found that the elevated baseline in an ion chromatogram contains many protein signals. One deficiency of current commercially available LC-ESI-MS data interpretation software is found to be the lack of functional operation that allows automated mass spectral integration and interpretation over signals hidden in the baseline. This current limitation can be overcome by a technique that involves the introduction of artificial pulses to an ion chromatogram by removing the solvent mixer in the HPLC pump. These artificial pulses are treated as chromatographic peaks by the software, thereby allowing automated spectral integration over the duration of a pulse. The reliability of mass analysis from the integrated spectra is shown to be dependent on spectral interpretation parameters such as mass spectral baseline threshold. The application of this method is demonstrated for rapid detection and mass analysis of low-molecular-mass proteins from cell extracts of Escherichia coli or Bacillus globigii.  相似文献   

18.
Genetic polymorphisms can significantly affect the enzyme activity of the drug metabolizing enzyme Cytochrome P450 2D6 (CYP2D6; OMIM 124030). Accordingly, CYP2D6 genotyping is considered as a valid approach to predict the individual CYP2D6 metabolizing status. We introduce ion-pair reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry (ICEMS) as method for the characterization of single base variants, small deletions, and insertions in the CYP2D6 gene. A two-step polymerase chain reaction (PCR) was developed for the simultaneous amplification of nine polymorphic regions within the CYP2D6 gene. Cleanup, separation, and denaturation of PCR amplicons were achieved by high-performance liquid chromatography. High-performance molecular mass measurements provided nucleotide composition profiles that principally enable the resolution of 37 reported CYP2D6 alleles. The developed assay was applied to the genotyping of 93 unrelated Austrian individuals. For validation, a selected number of samples and polymorphic sites were retyped by alternative genotyping technologies. The PCR-ICEMS assay turned out to be an accurate, robust, and cost-effective CYP2D6 genotyping strategy.  相似文献   

19.
This study details the sensitivity achieved with capillary columns when used with a micro-HPLC-electrospray ionization MS system. It is comprised of two sections, the first is the comparative study of three columns, one of narrow-bore diameter and two of capillary diameter. The second section compares three columns of decreasing diameter in the capillary scale. All the experiments achieved enhanced sensitivity using capillary columns. The increase in the experimental MS response ranged from -20% to +20% compared to the UV experimental response when decreasing the internal diameter of the columns used. When comparing the experimental MS response to the maximum theoretical UV response achievable, the increase in response ranged from 40 to 50%.  相似文献   

20.
A high performance liquid chromatography (HPLC) tandem mass spectrometric (MS/MS) method has been developed for the simultaneous determination of fifteen glucose, or acetate derived metabolites isolated from tumor cells. Glycolytic and tricarboxylic acid (TCA) cycle metabolites as well as acidic amino acids were separated on a HPLC porous graphitic carbon (PGC) column and simultaneously determined by means of triple quadrupole MS/MS using multiple reaction monitoring (MRM). Target compounds were eluted within 10 min with 8% v/v formic acid as an electronic modifier added to a 4:1 v/v methanol water mobile phase. The calibration is linear in the 1–100 μM concentration range for each analyte. The limit of detection ranges between 0.39 and 2.78 μM for the analytes concerned. To test the PGC–HPLC–MS/MS method in metabolomic studies, ZR-75.1 human mammary adenocarcinoma cells were labeled with U-13C glucose or 1-13C acetate. Applying the MRM mode, the incorporation of 13C into metabolites, isolated from the tumor cells, and derived from glucose or acetate, could be properly identified.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号