首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method using off-line supercritical fluid extraction (SFE) and micro liquid chromatography (μLC) with UV detection at 260 nm, was developed for selective determination of fenpyroximate in apple samples. The packed capillary liquid chromatography method utilises 20 μl injection volumes with on-column focusing. A 350×0.32 mm capillary column packed with Kromasil 100-C18 of 5 μm particle size was used with a mobile phase of acetonitrile–10 mM ammonium acetate (85:15, v/v) at a flow of 5 μl/min. A two-step SFE procedure was used to extract fenpyroximate selectively in 2 g apple samples, with Hydromatrix (HMX) added as a water absorbent at a 1:1 (w:w) ratio. Fenpyroximate was extracted at 200 bar and 90°C for 15 min using carbon dioxide at a flow of 2 ml/min, and solvent trapping collection in 10 ml acetonitrile. The volume of the acetonitrile extract was reduced by evaporation and water was added to a final composition of acetonitrile–water (40:60, v/v). The resulting 2.0 ml solution was filtered using a 0.45 μm poly(vinylidene difluoride) syringe filter before μLC analysis. Validation of the method was accomplished with apple samples spiked with fenpyroximate, covering the range of 0.1 to 1.0 μg/kg. The within-day and between-day repeatabilities were in the range 4–18% relative standard deviation. Accuracy, measured as recovery, was found to be approximately 60%. Apple samples from a field treated with fenpyroximate were analysed. None of the samples contained fenpyroximate above the quantification level.  相似文献   

2.
Determination of cadmium and lead in river water by sequential metal vapor elution analysis (SMVEA, column temperature; >1210 K) with argon carrier gas and an atomic absorption detector (AA) is reported. The column was a molybdenum tube inserted a tungsten coil. The flow rate of carrier gas was 1.8 ml min–1. Cadmium and lead were separated from Ca, Fe, K, Na, and Zn metal vapours by SMVEA with the step-heated column (1210–1520 K) at an atomization temperature of 1830 K. Under the optimal experimental conditions, the recoveries of spiked-cadmium and lead in river waters were in the range of 91 to 106%. It is to determine cadmium and lead in river water without the interferences by matrix elements observed by electrothermal AAS, after only the addition of hydrochloric acid to the sample.  相似文献   

3.
A flow injection procedure for the separation and pre-concentration of inorganic arsenic based on the complexation with ammonium diethyl dithiophosphate (DDTP) and sorption on a C-18 bonded silica gel minicolumn is proposed. During the sample injection by a time-based fashion, the As3+-DDTP complex is stripped from the solution and retained in the column. Arsenic(V) and other ions that do not form complexes are discarded. After reduction to the trivalent state by using potassium iodide plus ascorbic acid, total arsenic is determined by electrothermal atomic absorption spectrometry (ETAAS). Arsenic(V) concentration can be calculated by difference. After processing 6 ml sample volume, the As3+-DDTP complexes were eluted directly into the autosampler cup (120 μl). Ethanol was used for column rinsing. Influence of pH, reagent concentration, pre-concentration and elution time and column size were investigated. When 30 μl of eluate plus 10 μl of 0.1% (w/v) Pd(NO3)2 were dispensed into the graphite tube, analytical curve in the 0.3–3 μg As l−1 range was obtained (r=0.9991). The accuracy was checked for arsenic determination in a certified water, spiked tap water and synthetic mixtures of arsenite and arsenate. Good recoveries (97–108%) of spiked samples were found. Results are precise (RSD 7.5 and 6% for 0.5 and 2.5 μg l−1, n=10) and in agreement with the certified value of reference material at 95% confidence level.  相似文献   

4.
Colloidal palladium was used as a chemical modifier for analysis of complex samples by electrothermal atomic absorption spectrometry. In order to demonstrate high potential of the modifier, optimization of the time–temperature program of the atomizer was limited with only pyrolysis and atomization temperatures. Fixed palladium modifier masses were applied (6 μg for pure analyte solutions and 15 μg for matrix-containing solutions). It was shown that in the presence of colloidal palladium, interference-free determinations of As, Sb and Pb are possible up to at least 450 μg of chloride ion, or 40 μg of sulfate ion (as their sodium salts) in the atomizer. Colloidal palladium was used for the direct determination of As, Sb and Pb in a spiked sea water sample (from Bosphorus channel near Istanbul) by means of the calibration graphs prepared with pure analyte solutions. The detection limits for As, Sb and Pb in a sea water matrix calculated according to 2σ criteria are 5.4, 3.6 and 1.1 ng ml−1, respectively (for sample volume 10 μl). In unspiked sea water, the contents of As, Sb and Pb were found to be below the detection limits. Recoveries of spiked analytes (25 and 50 ng ml−1) were in the region of 98–112% depending on the nature of analyte and the concentration of spike.  相似文献   

5.
The suitability of Empore-activated carbon disks (EACD), Envi-Carb graphitized carbon black (GCB) and CPP-50 graphitized carbon for the trace enrichment of polar pesticides from water samples was studied by means of off-line and on-line solid-phase extraction (SPE). In the off-line procedure, 0.5-2 1 samples spiked with a test mixture of oxamyl, methomyl and aldicarb sulfoxide were enriched on EnviCarb SPE cartridges or 47 mm diameter EACD and eluted with dichloromethane-methanol. After evaporation, a sample was injected onto a C18-bonded silica column and analysed by liquid chromatography with ultraviolet (LC-UV) detection. EACD performed better than EnviCarb cartridges in terms of breakthrough volumes (>2 1 for all test analytes), reproducibility (R.S.D. of recoveries, 4–8%, n=3) and smapling speed (100 ml/min); detection limits in drinking water were 0.05–0.16 μg/l. In the on-line experiments, 4.6 mm diameter pieces cut from original EACD and stacked onto each other in a 9 mm long precolumn, and EnviCarb and CPP-50 packed in 10×2.0 mm I.D. precolumn, were tested, and 50–200 ml spiked water samples were preconcentrated. Because of the peak broadening caused by the strong sorption of the analytes on carbon, the carbon-packed precolumns were eluted by a separate stream of 0.1 ml/min acetonitrile which was mixed with the gradient LC eluent in front of the C18 analytical column. The final on-line procedure was also applied for the less polar propoxur, carbaryl and methiocarb. EnviCarb could not be used due to its poor pressure resistance. CPP-50 provided less peak broadening than EACD: peak widths were 0.1–0.3 min and R.S.D. of peak heights 4–14% (n = 3). In terms of analyte trapping efficiency on-line SPE-LC-UV with a CPP-50 precolumn also showed better performance than when Bondesil C18/OH or polymeric PLRP-S was used, but chromatographic resolution was similar. With the CPP-50-based system, detection limits of the test compounds were 0.05–1 μg/l in surface water.  相似文献   

6.
Rodriguez AM  de Torres AG  Pavon JM  Ojeda CB 《Talanta》1993,40(12):1861-1866
A method for the simultaneous spectrophotometric determination of cadmium, copper and zinc based on the formation of their complexes with 1,5-bis(di-2-pyridylmethylene)thiocarbonohydrazide is proposed. The absorption curves of these complexes overlap severely in the scanning range 380–480 nm. The analyte concentrations are calculated by a least squares fit of the pure spectra to the mixture spectra. A linear determination range of 0.1–1.7 μg/ml for cadmium, 0.1–1.3 μg/ml for copper and 0.2–1.2 μg/ml for zinc were obtained. The effect of interference was studied. The method has been applied to the determination of these metal ions in various type of materials.  相似文献   

7.
A method for the simultaneous determination of μg/1 or sub-μg/1 levels of cadmium and lead in sea water by chelation ion chromatography is demonstrated. The method consists in the preconcentration of a sea-water sample containing cadmium and lead on an iminodiacetate chelating resin; alkali and alkaline earth metals are removed from the resin with an ammonium acetate buffer, the metals are eluted and separated by cation-exchange chromatography, followed by postcolumn derivatization with 4-(2-pyridylazo)resorcinol and spectrophotometric detection at 520 nm. The concentration and separation steps are automated. The detection limit, when concentrating 200 ml of sea water, was found to be 2 ng for cadmium and 6 ng for lead. Relative standard deviations of 4.5% and 6.8% for 10 μg/1 of cadmium and lead, respectively, were obtained. Transition metals (Fe, Co, Ni, Zn, Cu, Mn) do not interfere in the analysis. An application of the method to the determination of cadmium and lead in sea-water samples collected in the Taranto gulf (Italy) is presented.  相似文献   

8.
Poly(styrene-divinylbenzene) (PS-DVB) membrane extraction disks were used as sorbents for the on-line solid phase extraction of 13 phenols (nitro and chlorophenols) in river and tap waters. Determination was performed by liquid chromatography with electrochemical detection (LC-ED). An acetate buffer-acetonitrile-methanol mixture as mobile phase and amperometric detection at +1100 mV were used. High water volumes, up to 250 ml, can be preconcentrated without loss of phenols (recoveries between 80% and 100%) except for the more polar ones. Moreover, detection limits between 0.01 and 0.1 μg l−1 in tap water and between 0.1 and 1.0 μg−1 in river water were obtained. The method has been applied to the analysis of two river water samples.  相似文献   

9.
A fully automated at-line solid-phase extraction-gas chromatography procedure has been developed for the analysis of aqueous samples using the PrepStation. The sample extract is transferred from the sample preparation module to the gas chromatograph via an autosampler vial. With flame-ionization detection, limits of determination (S/N=10) of 0.05–0.13 μg/l were obtained for the analysis of HPLC-grade water when modifying the PrepStation by: (i) increasing the sample volume to 50 ml, (ii) increasing the injection volume up to 50 μl, and (iii) decreasing the desorption volume to 300 μl. The HP autosampler had to be modified to enable the automated “at-once” on-column injection of up to 50 μl of sample extract. The amount of packing material in the original cartridge had to be reduced to effect the decrease of the desorption volume. The total set-up did not require any further optimization after having set up the method once. The analytical characteristics of the organonitrogen and organophosphorus test analytes, i.e. recoveries (typically 75–105%), repeatability (2–8%) and linearity (0.09–3.0 μg/l) were satisfactory. The potential of the system was demonstrated by determining triazines and organophosphorus pesticides in river Rhine water at the 0.6 μg/l level using flame-ionization and mass-selective detection. No practical problems were observed during the analysis of more than 100 river water samples.  相似文献   

10.
Ammonium perchlorate, a key ingredient in solid rocket propellants, has recently been found in ground and surface waters in the USA in a number of states, including California, Nevada, Utah, and West Virginia. Perchlorate poses a health risk and preliminary data from the US Environmental Protection Agency reports that exposure to less than 4–18 μg/l provides adequate human health protection. An ion chromatographic method was developed for the determination of low μg/l levels of perchlorate in drinking and ground waters based on a Dionex IonPac AS11 column, a 100 mM hydroxide eluent, large loop (1000 μl) injection, and suppressed conductivity detection. The method is free of interferences from common anions, linear in the range of 2.5–100 μg/l, and quantitative recoveries were obtained for low μg/l levels of perchlorate in spiked drinking and ground water samples. The method detection limit of 0.3 μg/l permits quantification of perchlorate below the levels which ensure adequate health protection. A new polarizable anion analysis column, the IonPac AS16, and its potential applicability for this analysis is also discussed.  相似文献   

11.
A procedure for separation and preconcentration of trace amounts of copper in natural water samples, has been proposed. It is based on the adsorption of copper(II) ions onto a column of Amberlite XAD-2 resin loaded with calmagite reagent. This way amounts of copper within the range from 0.0125 to 25.0 μg, in a sample volume of 25 to 250 ml, and pH from 3.7 to 10.0 was concentrated as calmagite complex in a column of 0.50 g of Amberlite XAD-2 resin. Copper (II) ion was desorpted by using 5.0 ml of 2 mol l−1 hydrochloric acid. Detection and determination limits of the proposed procedure for 250 ml sample volume were 0.15 and 0.50 μg l−1, respectively. Selectivity test showed that (in the indicated concentration), calcium(II) (500 mg l−1), magnesium(II) (500 mg l−1), strontium(II) (50 mg l−1), iron(III) (10 mg l−1), nickel(II) (10 mg l−1), cobalt(II) (10 mg l−1), cadmium(II) (10 mg l−1) and lead(II) (10 mg l−1) did not interfere in copper determination by this procedure. Precision of the method, evaluated as the relative standard deviation by analyzing a series of seven replicates, was 2.42% for a copper mass of 1.0 μg in a sample volume of 100 ml. The accuracy of the proposed procedure was evaluated by means of copper determination in reference biological samples. The achieved results were in good agreement with certified values. The extractor system had a sorption capacity of 1.59 μmol of copper per gram of resin loaded with calmagite. The proposed procedure was applied for copper determination by FAAS in natural water samples. Samples were collected from different places of Salvador city, Bahia, Brazil. The achieved recovery, measured by the standard addition technique, showed that the proposed procedure had good accuracy. A good enrichment factor (50×) and simplicity are the main advantages in this analytical procedure.  相似文献   

12.
Matoso E  Kubota LT  Cadore S 《Talanta》2003,60(6):1105-1111
An analytical method using silica gel chemically modified with zirconium (IV) phosphate for preconcentration of lead and copper, in a column system, and their sequential determination by flame atomic absorption spectrometry (FAAS), was developed. Sample solutions are passed through a glass column packed with 100 mg of the sorbent material, at pH 4.5, and lead and copper are eluted with 1.0 mol l−1 HNO3 at a flow rate of 2.0 ml min−1. The extraction of copper is affected by Fe(II), Mn(II), Zn(II), Ni(II) and Co(II) while only Fe(II) interferes in the lead determination. These interferences may be overcome with an appropriate addition of a KI or NaF solution. An enrichment factor of 30 was obtained for both metals. While the limits of detection (3σ) were 6.1 and 1.1 μg l−1, for Pb and Cu, respectively, the limits of determination were 16.7 and 3.3 μg l−1. The precision expressed as relative standard deviation (R.S.D.) obtained for 3.3 μg l−1 of Cu and 16.7 μg l−1 of Pb were 4.3 and 4.7%, respectively, calculated from ten measurements. The proposed method was evaluated with reference material and was applied for the determination of lead and copper in industrial and river waters.  相似文献   

13.
An integrated on-line SPE–HPLC–MS/MS system has been developed for the rapid analysis of various trace level priority pesticides in surface and drinking water. Eleven pesticides were included in this study, with various phenylureas, triazines and organophosphorous species among them. Use of turbulent-flow chromatography columns (TFC, 50×1 mm, 30–50 μm particle size) as extraction cartridges enables fast on-line SPE at high sampling flow-rate (5 ml/min). Polymeric and carbon based TFC columns (Oasis HLB, Cyclone, Hypercarb) allow complete extraction with good recoveries from water volumes up to 50 ml. On-line coupling to HPLC is performed with re-mixing of the organic TFC eluate with water in front of the analytical column to ensure efficient band focussing. For fast HPLC analysis, a short monolithic column is applied in combination with highly selective API–MS/MS detection. Matrix effects on the APCI–MS/MS signal were found to be reduced by the system to an acceptable minimum. Limits of detection, determined for 10-ml samples of river water were in the range between 0.4 and 13 ng/l typically, except trifluralin (approximately 280 ng/l), which is less susceptible to ionization under atmospheric pressure conditions. At an enriched water volume of 10 ml, the whole SPE–HPLC–MS/MS procedure requires less than 14 min. The method was successfully applied to the analysis of drinking and surface water samples taken from several sampling sites around the city of Leipzig, Germany. Concentrations measured (maximum: 16 ng/l simazine in river water) were far below the concentration limits scheduled by law.  相似文献   

14.
Bones J  Thomas K  Nesterenko PN  Paull B 《Talanta》2006,70(5):1117-1128
A simplified preconcentration method for a range of ultra-trace level pharmaceuticals in natural waters has been developed. Solid phase extraction was performed on-line using a micro-reversed-phase monolithic silica column, allowing for very rapid trace enrichment from large volume (500 ml) samples with minimal sample handling. Acceptable recoveries of >70% were obtained for the majority of compounds investigated and the monolithic columns could be washed and conditioned on-line with no sample carryover and used reproducibly for up to eight extractions each. The on-line SPE-LC-UV method was coupled to electrospray ionisation ion trap mass spectrometry (ESI-MS) to increase both selectivity and specificity. Detection limits were determined in spiked river and tap water samples and found to lie in the low ng/l region using sample volumes of 500 ml, loaded at a flow rate of 10 ml/min, and therefore, were suitable for ultra trace analysis.  相似文献   

15.
Arbab-Zavar MH  Hashemi M 《Talanta》2000,52(6):2842-1014
A batch electrochemical hydride generation system was developed for the spectrophotometric determination of inorganic As(III) by silver diethyldithiocarbamate. This method is based on electrochemical reduction of As to Arsine (AsH3) in acidic media and on the subsequent reaction of AsH3 with silver diethyldithiocarbamate to give an absorbing complex at 525 nm. The electrochemical generator consisted of a cathode cell separated from the anode cell by a porous glass frit and was operated with a constant direct current. A pre-activated graphite rod was used as cathode material for the production of AsH3. The parameters related to the electrochemical hydride generation were investigated. Under optimized conditions, only As(III) can be converted to AsH3 and a pre-reducing stage is required for total inorganic As analysis. The characteristic data of the electrochemical hydride generation and common hydride generation by NaBH4 were compared. Also, the effects of interferences and their elimination were investigated. An absolute detection limit of 0.5 μg (3sb) and a concentration detection limit of 0.05 μg/ml were obtained using a 10 ml sample volume. The relative standard deviation for five replicate analysis of 30 μg As(III) was 1.2%. The accuracy and recovery of the method were demonstrated by analysing spiked artificial sea water and tap water.  相似文献   

16.
Liu JF  Liang X  Jiang GB  Cai YQ  Zhou QX  Liu GG 《Talanta》2003,60(6):1155-1161
An on-line coupled continuous flow liquid membrane extraction (CFLME) and C18 precolumn system was developed for sample preconcentration in liquid chromatography determination. After preconcentration by CFLME, which is based on the combination of continuous flow liquid–liquid extraction and supported liquid membrane, bisphenol A (BPA) was enriched in 960 μl of 1 mol l−1 NaOH used as acceptor. This acceptor was on-line neutralized and transported onto the C18 precolumn where analytes were absorbed and focused. Then the focused analytes were injected onto a C18 analytical column for separation and detected at 220 nm with a diode array detector. CFLME related parameters such as flow rates, pH of donor and acceptor, and enrichment time were optimized. The proposed method presents a detection limit of 0.03 μg l−1 (S/N=3) when 60 ml samples was enriched with an enrichment time of 30 min. Compared with C18 based column-switching procedure, this proposed procedure presents similar sample throughput and lower detection limits. The proposed method was successfully applied to determine BPA in tap water, river water, and municipal sewage effluent samples.  相似文献   

17.
Khajeh M  Yamini Y  Hassan J 《Talanta》2006,69(5):1088-1094
In the present work, a rapid method for the extraction and determination of chlorobenzenes (CBs) such as monochlorobenzene, 1,2-dichlorobenzene, 1,3-dichlorobenzene, 1,4-dichlorobenzene, 1,2,3-trichlorobenzene and 1,2,4-trichlorobenzene in water samples using the headspace solvent microextraction (HSME) and gas chromatography/electron capture detector (ECD) has been described. A microdrop of the dodecane containing monobromobenzene (internal standard) was used as extracting solvent in this investigation. The analytes were extracted by suspending a 2.5 μl extraction drop directly from the tip of a microsyringe fixed above an extraction vial with a septum in a way that the needle passed through the septum and the needle tip appeared above the surface of the solution. After the extraction was finished, the drop was retracted back into the needle and injected directly into a GC column. Optimization of experimental conditions such as nature of the extracting solvent, microdrop and sample temperatures, stirring rate, microdrop and sample volumes, the ionic strength and extraction time were investigated. The optimized conditions were as follows: dodecane as the extracting solvent, the extraction temperature, 45 °C; the sodium chloride concentration, 2 M; the extraction time, 5.0 min; the stirring rate, 500 rpm; the drop volume, 2.5 μl; the sample volume, 7 ml; the microsyringe needle temperature, 0.0 °C. The limit of detection (LOD) ranged from 0.1 μg/l (for 1,3-dichlorobenzene) to 3.0 μg/l (for 1,4-dichlorobenzene) and linear range of 0.5–3.0 μg/l for 1,2-dichlorobenzene, 1,3-dichlorobenzene and from 5.0 to 20.0 μg/l for monochlorobenzene and from 5.0 to 30 μg/l for 1,4-dichlorobenzene. The relative standard deviations (R.S.D.) for most of CBs at the 5 μg/l level were below 10%. The optimized procedure was successfully applied to the extraction and determination of CBs in different water samples.  相似文献   

18.
A fast analytical method for quantifying a mixture of 12 naphthalenesulfonates and naphthalenedisulfonates has been developed. This method consists of on-line ion-pair solid-phase extraction with PLRP-s sorbent and ion-pair liquid-chromatography using fast-scanning fluorescence spectrometer as a detection system and multivariate calibration. As complete separation is unnecessary, the compounds were analysed in isocratic conditions and the chromatographic analysis took only 25 min. Three-way partial least-squares (PLS) was used to carry out multivariate calibration for spiked tap water. In these conditions, quantification limits were between 0.01 and 3 μg l−1. Repeatability was also evaluated and relative standard deviations (n=3) were between 0.5 and 4, depending on the compound. Finally, spiked tap and Ebro river waters were analysed to evaluate prediction capability of the method.  相似文献   

19.
A method for the rapid trace analysis of 17 residual pesticides in water by narrow-bore capillary (I.D. 100 microm) gas chromatography-mass spectrometry (GC-MS) using a programmable temperature vaporizer (PTV) was discussed. The method consisted of a large-volume injection (40 microl) by a PTV, high-speed analysis using a narrow-bore capillary column and MS detection. The PTV with solvent vent mode was very useful for large-volume injection into a narrow-bore capillary column because the injected solvent volume could be reduced to less than 2 microl. The analysis time was 8.5 min [less than 50% of the analysis time using conventional columns (I.D. 250 microm)]. A 10-ml volume of river water was extracted by dichloromethane (4 ml), and then the extract was condensed to 1 ml. This extract was analyzed. Mean recoveries for river water spiked at 100 pg/ml ranged from 83.4 to 96.7%. The limit of detections of the 17 pesticides ranged from 1 to 100 pg/ml.  相似文献   

20.
Montero R  Gallego M  Valcarcel M 《Talanta》1990,37(12):1129-1132
A simple method for the determination of chloramphenicol in pure powders, capsules, tablets, oral suspensions and eye ointments, based on its reduction to the amino derivative by a cadmium or zinc column, is reported. Chloramphenicol can be determined in the range 2–30 μg/ml, with a relative standard deviation of 1.5% and a sampling frequency of 150/hr. The proposed method has greater simplicity, sensitivity and rapidity than the previously reported batch method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号