首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
对一种斜翅型外翅片带内螺纹的冷凝强化换热管进行传热性能的实验研究。管外冷凝换热的制冷剂为R134a,管内对流换热的介质为水。分别在定热流密度与定水流速的条件下进行一系列工况的实验,得到相应的实验数据。在定热流密度条件下,利用Wilson图解法得到管内的换热系数数据及相应的计算关联式。在定水流速的条件下,利用分离方法得到管外冷凝换热系数数据及相应的计算关联式。将强化管换热系数数据与光管换热系数的理论计算值进行了比较,结果表明:冷凝强化换热管管内对流换热的强化倍率为2.4,管外凝结换热系数随壁面过冷度的增加而增大,管外凝结换热的强化倍率为:1.78~3.92。  相似文献   

2.
D. Panahi 《实验传热》2017,30(3):179-191
Air bubble injection was employed to increase the heat transfer rate (Nusselt number) of a vertical shell and coiled tube heat exchanger in this article. Hot and cold water flowed into the coil side and shell side of heat exchanger, respectively, and air bubbles were injected inside the shell side of heat exchanger via a memorable method. Bubbles' vertical movement due to buoyancy forcing through the heat exchanger can enhance the heat transfer rate by mixing the thermal boundary layer, increasing the turbulence level of the fluid flow and increasing the shell-side fluid Reynolds number.  相似文献   

3.
螺旋槽管管内湍流流动与换热的三维数值模拟   总被引:1,自引:0,他引:1  
利用Fluent对5种不同槽深的螺旋槽管进行了模拟求解,得出了湍流状态下螺旋槽管内流体的速度场和温度场,从微观上说明了螺旋槽管的强化传热机理。分析了槽深对螺旋槽管阻力性能和换热性能的影响。数值计算结果表明,该类螺旋槽管在湍流工况下的平均Nu数大约是光管的1.6—2.1倍,平均阻力系数f大约是光管1.5—4.5倍。与实验数据进行比较发现,数值模拟具有相当的可靠性。  相似文献   

4.
G. Arslan  N. Eskin 《实验传热》2013,26(6):707-720
In this study, condensation of pure refrigerant R134a vapor inside a vertical 18° helical microfin tube was experimentally investigated. Tests were performed at saturation pressure of 5.7–5.9 bar with mass fluxes of 20–100 kg/m2s and heat fluxes of 1.7–5.3 kW/m2. The effects of mass flux and the temperature difference between the refrigerant and tube wall (ΔT) on the heat transfer performance were analyzed throughout experimental data. For experiments in which ΔT is more than 2.5°C, the average condensation Nusselt number showed a tendency to be independent from ΔT. Heat transfer enhancement ratio was found to be 1.59–1.71, which is always higher than the heat transfer area enhancement factor (1.55). Fins always act as a turbulence promoter in the given experimental data range. Finally, the most widely used heat transfer coefficient correlations for condensation inside microfin tubes were analyzed through the experimental data. Best fit was obtained with Yu and Koyama's correlation with an absolute mean deviation of 17% and Kedzierski and Goncalves's correlation with an absolute mean deviation of 19%.  相似文献   

5.
在水平管外沸腾换热实验中,热流密度沿管长方向的变化幅度较大,采用Wilson方法所得到的管内对流换热系数偏高,而管外沸腾换热系数偏低.为解决这一问题,本文提出了一种新的数据处理方法-局部换热系数法,并采用这种方法对实验测定R134a在水平放置的机械加工强化表面沸腾传热管的实验数据进行分析和处理,得到了较合理的结果.  相似文献   

6.
螺旋扁管管外蒸汽冷凝双侧强化传热试验研究   总被引:1,自引:0,他引:1  
为促进螺旋扁管在冷凝换热装置上的应用,对螺旋椭圆管管外蒸汽冷凝工况下的传热特性进行了试验研究。研究结果表明,螺旋椭圆管在强化管内无相变对流传热的同时也可以强化管外冷凝传热。相同工况下,同圆管相比,所用螺旋椭圆扁管的总传热系数高11%-16%,管内传热系数高约18%,管外冷凝传热系数高约9%。并从二次流减薄传热边界层及冷凝表面利于排除冷凝液的角度,分析了螺旋椭圆扁管的双侧强化传热机理。  相似文献   

7.
In this work, we study numerically the heat transfer and fluid flow inside a circular inclined tube. The thermal boundary condition is that of a constant and uniform (axially and circumferentially) heat flux on the tube wall. A finite volume method is used to solve, in dimensionless form, the parabolic equations of mixed convection. The results, obtained for water with different combinations of the Grashof number and the tube inclination, show that the average heat transfer is improved and the wall shear stress is increased compared to those of pure forced flow.  相似文献   

8.
Heat transfer was studied to two-phase flow in the post-CHF dispersed flow regime under swirl conditions. Data were used for post-CHF water flow at high pressure, 15.9 MPa, inside a vertical tube with twisted-tape inserts. Data used were obtained under test conditions typical of heat exchanger operation with low wall superheats of 5-40°C. The mass flux range of the data was 910-1878 kg/m2 s, and three tape-twist ratios were used: 2.55, 5.03, and 7.52. The low wall superheat and the relatively high mass fluxes resulted in higher than predicted drop-wall heat transfer. The only existing heat transfer correlation for this flow situation was modified to include this heat exchanger parameter range.  相似文献   

9.
FC-72在竖直壁面上及微小三角型通道内的沸腾传热   总被引:1,自引:0,他引:1  
本文对浸在FC-72液池中的竖直壁面及两个微小三角形通道进行了沸腾实验研究,考虑了管道尺寸对沸腾传热特性的影响。两个微小三角形通道的边长分别为1.5和2.5 mm,水力直径分别为0.87和1.44 mm,长度50 mm,采用铜块上开V型沟槽,再覆盖上透明的玻璃片构成。热流密度由贴在铜块背后的膜状加热器提供。实验得到了沸腾曲线和传热系数,并用DV摄影机拍摄到了沸腾状况。实验结果显示,管道尺寸对沸腾传热特性有显著的影响,CHF值随通道尺寸的减小而减小,小通道在低热流密度时传热系数较大。  相似文献   

10.
纳米流体对流换热的实验研究   总被引:15,自引:3,他引:12  
建立了测量纳米流体对流换热系数的实验系统,测量了不同粒子体积份额的水-Cu纳米流体在层流与湍流状态下的管内对流换热系数,实验结果表明,在液体中添加纳米粒子增大了液体的管内对流换热系数,粒子的体积份额是影响纳米流体对流换热系数的因素之一。综合考虑影响纳米流体对流换热的多种因素,提出了计算纳米流体对流换热系数的关联式。  相似文献   

11.
G. Arslan  N. Eskin 《实验传热》2015,28(5):430-445
In this study, condensation of pure refrigerant R134a vapor inside a smooth vertical tube was experimentally investigated. The test section was made of a copper tube with inside diameter of 7.52 mm and length of 1 m. Experimental tests were conducted for mass fluxes in the range of 20–175 kg/m2s with saturation pressure ranging between 5.8 and 7 bar. The effects of mass flux, saturation pressure, and temperature difference between the refrigerant and tube inner wall (ΔT) on the heat transfer performance were analyzed through experimental data. Obtained results showed that average condensation heat transfer coefficient decreases with increasing saturation pressure or temperature difference (ΔT). In addition, for the same temperature difference (ΔT), heat can be removed from the refrigerant at a higher rate at relatively low pressure values. Under the same operating conditions, it was shown that average condensation heat transfer coefficient increases as mass flux increases. Finally, the most widely used heat transfer coefficient correlations for condensation inside smooth tubes were analyzed through the experimental data. The best fit was obtained with Akers et al.'s (1959) correlation with an absolute mean deviation of 22.6%.  相似文献   

12.
针对螺旋扁管壁面温度难于准确测试的特点,提出采用线性曲线回归与非线性曲线回归相结合的方法进行管内传热系数计算.进行了光管与螺旋扁管管内对流传热实验,并用该方法计算管内对流传热系数.光管传热系数计算值与经典公式的大偏差小于6%.螺旋扁管管内传热系数的计算值略大于通过测量壁温获得的传热系数值,分析了二者存在差异的原因.组合...  相似文献   

13.
本文提出了利用管外流体诱导振动实现强化传热的新方法.采用了一种新的传热元件-弹性管束,它对管外流体流动具有良好的振动响应特性.提出了正置三角柱脉动流发生装置,该装置可诱导起弹性管束一定频率的周期性振动,并对强化传热具有显著的促进作用.在恒热流条件下,对管外水流诱导振动强化对流换热规律进行了试验研究,得到了管外对流换热的准则方程式.  相似文献   

14.
This study reports an experimental investigation of evaporative heat transfer and pressure drop of R-134a flowing downward inside vertical corrugated tubes with different corrugation pitches. The double tube test section is 0.5 m long with refrigerant flowing in the inner tube and hot water flowing in the annulus. The inner tubes are comprised of one smooth tube and three corrugated tubes with different corrugation pitches of 6.35, 8.46, and 12.7 mm. The test runs are performed at evaporating temperatures of 10°C, 15°C, and 20°C; heat fluxes of 20, 25, and 30 kW/m2; and mass fluxes of 200, 300, and 400 kg/m2s. The experimental data obtained from the smooth tube are plotted with flow pattern map for vertical flow. Comparisons between smooth and corrugated tubes on the heat transfer and pressure drop are also discussed. It is observed that the heat transfer coefficient and frictional pressure drop obtained from the corrugated tubes are higher than those from the smooth tube. Furthermore, the heat transfer coefficient and frictional pressure drop increase as the corrugation pitch decreases. The maximum heat transfer enhancement factor and penalty factor are up to 1.22 and 4.0, respectively.  相似文献   

15.
An experimental study of condensation heat transfer characteristics of flow inside horizontal micro-fin tubes is carried out using R410A, R22, and R32 as the test fluids. This study especially focuses on the influence of heat transfer area upon the condensation heat transfer coefficients. The test sections were made of double tubes using the counter-flow type; the refrigerants condensation inside the test tube enabled heat to exchange with cooling water that flows from the annular side. The saturation temperature and pressure of the refrigerants were measured at the inlet and outlet of the test sections to defined state of refrigerants, and the surface temperatures of the tube were measured. A differential pressure transducer directly measured the pressure drops in the test section. The heat transfer coefficients and pressure drops were calculated using the experimental data. The condensation heat transfer coefficient was measured at the saturation temperature of 48°C with mass fluxes of 50–380 kg/(m2s) and heat fluxes of 3–12 kW/m2. The values of experimental heat transfer coefficient results are compared with the predicted values from the existing correlations in the literature, and a new condensation heat transfer coefficient correlation is proposed.  相似文献   

16.
In this work, the flow boiling of TiO2/water and Al2O3/water nanofluids was investigated experimentally and simulated with two phases. Experimental results were obtained in two directions and compared together. The volume fraction and heat transfer coefficient obtained from the vertical tube were compared with those obtained from the horizontal tube. The results showed that the contours of vapor volume fraction in horizontal tube are completely different from the vertical tube, which is due to the buoyancy effect. Moreover, the effect of nanoparticles on both flow directions was almost the same, while heat transfer coefficient was not the same in these flow directions. Based on the experimental result, presence of nanoparticles in the base fluid cannot increase the heat transfer coefficient.  相似文献   

17.
以常压去离子水为工质,对自然循环工况下上升加热段内单相水的摩擦阻力及对流传热特性进行了实验研究.结果表明,自然循环工况下加热段内由浮升力引起的自由流动对摩擦阻力及对流传热特性有重要影响,自然循环与强制循环二种工况下加热段内的摩阻系数及对流换热系数存在明显差别;并且,自然循环工况下加热段内的摩擦阻力存在滞后现象.通过实验提出了计算自然循环工况下加热段内单相水的摩阻系数及对流换热系数的经验关系式.  相似文献   

18.
细圆管内流动凝结换热的实验研究   总被引:2,自引:1,他引:1  
通过实验,分析细圆管的倾斜角度和管径对管内蒸气流动凝结换热的影响。利用实测的管壁温度变化。估计凝结液沿周向的分布。探讨不同倾角和管径条件下;重力作用影响凝结换热的机制。研究表明,在小尺度下,重力的影响受蒸气剪切力和表面张力作用而削弱,现有通行的关联式不适用于细圆管内的凝结换热。  相似文献   

19.
Abstract

Forced convective heat transfer in a narrow concentric annulus was enhanced by turbulence promoters to improve the heat removal from a high-temperature gas-cooled reactor, a gas-cooled fusion reactor, and other narrow flow passages. The present experiments, which differed from those performed in conventional research, were carried out to examine the effect of turbulence promoters on the inner insulated wall opposite the outer smooth heated wall. This was achieved by changing the ratio of the pitch and the height P/ε, the ratio of the height and the space ε/ε1, and the type of turbulence promoters used. Experimental results were examined for the local heat transfer coefficient distribution on the smooth outer tube, the average heat transfer coefficient, the friction factor, and the thermal performance. Five kinds of evaluations for thermal performance were carried out.P24  相似文献   

20.
全玻璃真空太阳能热水器强化换热机理分析   总被引:1,自引:0,他引:1  
本文应用Ansys Fluent软件对加装导流板全玻璃真空太阳能热水器内自然对流流场进行三维数值模拟计算,并与实验进行对比分析,通过改变导流板长度和位置改善热水器内的流动和换热。结果表明,与无导流板结构相比较,加装导流板后管内涡流消失,流体流动稳定,有利于管内自然对流,增强了换热效果,水箱内温度分层效果明显,有助于提高换热效率;同时得出导流板长度最佳选择范围为1.4~1.6 m,导流板加装在玻璃管中间位置与距管中间位置偏下1/2之间范围内更有助于换热。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号