首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Yan CT  Shih TS  Jen JF 《Talanta》2004,64(3):650-654
Microwave-assisted desorption (MAD) coupled to in situ headspace solid-phase microextraction (HS-SPME) was first proposed as a possible alternative pretreatment of samples in absorbent collected from workplace monitoring. Aniline collected on silica gel was investigated. Under microwave irradiation, the aniline was desorbed from silica gel and directly absorbed onto the SPME fiber in the headspace. Having been sampled on the SPME fiber, and desorbed in the GC injection port, aniline was analyzed using a GC-FID system. Parameters that affect the proposed extraction efficiency, including the extraction media and its pH, the microwave irradiation power and the irradiation time as well as desorption parameters of the GC injector, were investigated. Experimental results revealed that the extraction of a 150-mg silica gel sample using a 0.8-ml aqueous solution (pH 12) and a PDMS/DVB fiber under medium-high-powered irradiation (345 W) for 3 min maximized the efficiency of extraction. Desorption of aniline from the SPME fiber was optimal at 230 °C held for 3 min. The detection limit was 0.09 ng. The proposed method provided a simple, fast, and organic solvent-free procedure to analyze aniline from a silica gel matrix.  相似文献   

2.
Microwave-assisted thermal desorption (MAD) coupled to headspace solid-phase microextraction (HS-SPME) has been studied for in-situ, one-step, sample preparation for PAHs collected on XAD-2 adsorbent, before gas chromatography with mass spectrometric detection. The PAHs on XAD-2 were desorbed into the extraction solution, evaporated into the headspace by use of microwave irradiation, and absorbed directly on a solid-phase microextraction fiber in the headspace. After desorption from the SPME fiber in the hot GC injection port, PAHs were analyzed by GC–MS. Conditions affecting extraction efficiency, for example extraction solution, addition of salt, stirring speed, SPME fiber coating, sampling temperature, microwave power and irradiation time, and desorption conditions were investigated. Experimental results indicated that extraction of 275 mg XAD-2, containing 10–200 ng PAHs, with 10-mL ethylene glycol–1 mol L−1 NaCl solution, 7:3, by irradiation with 120 W for 40 min (the same as the extraction time), and collection with a PDMS–DVB fiber at 35 °C, resulted in the best extraction efficiency. Recovery was more than 80% and RSD was less than 14%. Optimum desorption was achieved by heating at 290 °C for 5 min. Detection limits varied from 0.02 to 1.0 ng for different PAHs. A real sample was obtained by using XAD-2 to collect smoke from indoor burning of joss sticks. The amounts of PAHs measured varied from 0.795 to 2.53 ng. The method is a simple and rapid procedure for determination of PAHs on XAD-2 absorbent, and is free from toxic organic solvents.  相似文献   

3.
Ming-Chi Wei 《Talanta》2007,72(4):1269-1274
The novel pretreatment technique, microwave-assisted heating coupled to headspace solid-phase microextraction (MA-HS-SPME) has been studied for one-step in situ sample preparation for polycyclic aromatic hydrocarbons (PAHs) in aqueous samples before gas chromatography/flame ionization detection (GC/FID). The PAHs evaporated into headspace with the water by microwave irradiation, and absorbed directly on a SPME fiber in the headspace. After being desorbed from the SPME fiber in the GC injection port, PAHs were analyzed by GC/FID. Parameters affecting extraction efficiency, such as SPME fiber coating, adsorption temperature, microwave power and irradiation time, and desorption conditions were investigated.Experimental results indicated that extraction of 20 mL aqueous sample containing PAHs at optional pH, by microwave irradiation with effective power 145 W for 30 min (the same as the extraction time), and collection with a 65 μm PDMS/DVB fiber at 20 °C circular cooling water to control sampling temperature, resulted in the best extraction efficiency. Optimum desorption of PAHs from the SPME fiber in the GC hot injection port was achieved at 290 °C for 5 min. The method was developed using spiked water sample such as field water with a range of 0.1-200 μg/L PAHs. Detection limits varied from 0.03 to 1.0 μg/L for different PAHs based on S/N = 3 and the relative standard deviations for repeatability were <13%. A real sample was collected from the scrubber water of an incineration system. PAHs of two to three rings were measured with concentrations varied from 0.35 to 7.53 μg/L. Recovery was more than 88% and R.S.D. was less than 17%. The proposed method is a simple, rapid, and organic solvent-free procedure for determination of PAHs in wastewater.  相似文献   

4.
Determination of aniline in wastewater was investigated by microwave-assisted headspace solid-phase microextraction (MA-HS-SPME), for one-step in-situ sample preparation, and gas chromatography. Aniline in the water was evaporated into the headspace under the action of microwave irradiation and adsorbed directly by the SPME fiber. After desorption in the GC injection port and gas chromatography aniline was detected by FID. Conditions affecting the extraction efficiency, for example the pH of the water, addition of salt, microwave power and irradiation time, and desorption conditions were investigated. Experimental results indicated that adjustment of the pH of the water sample to 12 and headspace SPME sampling with a PDMS-DVB fiber under medium–high power irradiation (345 W) for 3 min resulted in the best extraction efficiency. Desorption of aniline was optimum when the SPME fiber was heated at 230 °C for 3 min. The detection limit was approximately 0.01 g mL–1. The proposed method is a simple, fast, and organic-solvent-free procedure for analysis of aniline in water. Application was illustrated by analysis of aniline in wastewater from a polymer factory.  相似文献   

5.
Microwave-assisted extraction coupled to headspace solid-phase microextraction was studied and applied for one-step in-situ sample preparation prior to analysis of chlorophenols (CPs) in soil samples. The CPs in soil sample were extracted into the aqueous solution and then directly onto the solid-phase microextraction (SPME) fiber in headspace under the aid of microwave irradiation. After being desorbed from SPME fiber in the GC injection port, CPs were analyzed with a GC-electron-capture detection system. Parameters affecting the extraction efficiency such as the extraction solutions, the pH in the slurry, the humic acid content in the soil, the power and the irradiation time of microwave as well as the desorption parameters were investigated. Experimental results indicated that the extraction of a 1.0 g soil sample with a 6-ml aqueous solution (pH 2) and a polyacrylate fiber under the medium-power irradiation (132 W) for 9 min achieved the best extraction efficiency of about 90% recovery and less than 10% RSD. Desorption was optimal at 300 degrees C for 3 min. Detection limits were obtained at around 0.1-2.0 microg/kg levels. The proposed method provided a simple, fast, and organic solvent-free procedure to analyze CPs from soil sample matrix.  相似文献   

6.
The pretreatment technique of microwave-assisted extraction on-line headspace solid-phase microextraction (MAE-HS-SPME) was designed and studied for one-step in-situ sample preparation prior to the chromatographic analysis of a pesticide on vegetables. The pesticide on chopped vegetables was extracted into an aqueous solution with the aid of microwave irradiation and then directly onto the SPME fiber in headspace. After being collected on to the SPME fiber and desorbed in the GC injection port, the pesticide (dichlorvos) was analyzed with a GC-electron-capture detection system. The optimum conditions for obtaining extraction efficiency, such as the pH, the polarity modifier, and the salt added in sample solution, the microwave irradiation, as well as the desorption parameters were investigated. Experimental results indicated that the proposed MAE-HS-SPME technique attained the best extraction efficiency of 106% recovery under the optimized conditions, i.e. irradiation of extraction solution (10% aqueous ethylene glycol) at pH 5.0 with medium microwave power for 10 min. Desorption at 220 degrees C for 3 min offered the best detection result. The detection was linear at 5-75 microg/l with correlation coefficient of 0.9985. Detection limit was obtained at approximately 1.0 microg/l level based on S/N=3. The proposed method provided a very simple, fast, and solvent-less procedure to collect pesticides directly from vegetables for GC determination. Its application was illustrated by the analysis of trace dichlorvos in vegetables.  相似文献   

7.
This investigation evaluates headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) to determine trace levels of organotins in water. The organotins were derivatized in situ with sodium tetraethylborate and adsorbed on a poly(dimethysiloxane) (PDMS)-coated fused silica fiber. The SPME experimental procedures to extract organotins in water were at pH 5, with extraction and derivatization simultaneously at 45 degrees C for 30 min in a 2% sodium tetraethylborate solution and a sample solution volume in the ratio of 1:1, and desorption in the splitless injection port of the GC at 260 degrees C for 2 min. Detection limits are determined to be in the low ng/L range. According to the analysis, the linearity range is from 10 to 10,000 ng/L with R.S.D. values below 12% except triphenyltin (24%). The proposed method was tested by analyzing surface seawater from the harbors on the Taiwanese coast for organotins residues. Some organotins studied were detected in the analyzed samples. Results of this study demonstrate the adequacy of the headspace SPME-GC-MS method for analyzing organotins in sea water samples.  相似文献   

8.
陈军 《色谱》2002,20(1):87-89
 采用顶空固相微萃取技术和气相 质谱联用技术对纺织品中的挥发性防虫蛀剂的残留进行了测定。该方法对挥发性二氯苯和萘的检测限量为 1μg/kg ,回收率为 83 6 %~ 115 2 % ,相对标准偏差为 8 1%~ 9 8%。  相似文献   

9.
A method was developed for the selective determination of Se4+ in drinkable water by solid-phase microextraction (SPME) and gas chromatography/mass spectrometry (GC/MS). Se4+ was selectively derivatized to ethane, 1,1'-selenobis by reaction with sodium tetraethylborate, extracted by the SPME fiber, and determined by GC/MS. Both headspace (HS)-SPME and direct SPME were studied. The method requires only a few milliliters of sample and 20 min for completion. At 2.0 microg/L concentration, the relative standard deviation was 10.1% for HS-SPME and 9.1% for direct SPME. For HS-SPME, the theoretical detection limit was 81 ng/L and 166 ng/L for direct SPME. The recovery rate was 95%. The method was used to determine Se4+ in 10 tap water samples.  相似文献   

10.
A new generation of solid-phase microextraction (SPME) fiber, an internally cooled fiber (cold fiber with polydimethylsiloxane loading) that allows heating the sample matrix and simultaneously cooling the fiber coating, was used to determine 2,4-dichloroanisole, 2,6-dichloroanisole, 2,4,6-trichloroanisole and pentachloroanisole in cork. A comparison between the cold fiber and regular SPME fiber was performed. An automated headspace solid-phase microextraction (HS-SPME) using commercial fibers and an internally cooled SPME fiber (CF-HS-SPME) coupled to gas chromatography-time-of-flight mass spectrometry (GC-TOF-MS) was used. The extraction conditions for both CF-HS-SPME and HS-SPME were optimized using full factorial design and Doehlert matrix. The best extraction conditions for CF-HS-SPME were obtained using 10 min of incubation time, 10 min of extraction time, and sample and fiber temperature of 130 and 10 degrees C, respectively. For HS-SPME, polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was used with 10 min of incubation time, 75 min of extraction time, 85 degrees C of sample temperature, 8 ml of water was added and agitated at 500 rpm. The quantification limits for the target compounds using CF-HS-SPME procedure were between 0.8 and 1.6 ng g(-1) of cork, while for HS-SPME were between 4 and 6 ng g(-1) of cork. Furthermore, the CF-HS-SPME procedure could be used as a non-destructive method after minor modification of the agitator for the autosampler.  相似文献   

11.
The analysis of samples contaminated by organic compounds is an important aspect of environmental monitoring. Because of the complex nature of these samples, isolating target organic compounds from their matrices is a major challenge. A new isolation technique, solid phase microextraction, or SPME, has recently been developed in our laboratory. This technique combines the extraction and concentration processes into one step; a fused silica fiber coated with a polymer is used to extract analytes and transfer them into a GC injector for thermal desorption and analysis. It is simple, rapid, inexpensive, completely solvent-free, and easily automated. To minimize matrix interferences in environmental samples, SPME can be used to extract analytes from the headspace above the sample. The combination of headspace sampling with SPME separates volatile and semi-volatile analytes from non-volatile compounds, thus greatly reducing the interferences from non-target compounds. This paper reports the use of headspace SPME to isolate volatile organic compounds from various matrices such as water, sand, clay, and sludge. By use of the technique, benzene, toluene, ethyl-benzene, and xylene isomers (commonly known as BTEX), and volatile chlorinated compounds can be efficiently isolated from various matrices with good precision and low limits of detection. This study has found that the sensitivity of the method can be greatly improved by the addition of salt to water samples, water to soil samples, or by heating. Headspace SPME can also be used to sample semi-volatile compounds, such as PAHs, from complex matrices.  相似文献   

12.
A headspace solid-phase microextraction method (HS-SPME) followed by gas chromatography with mass spectrometric detection (GC/MS) has been developed for the determination of low concentrations of nicotine in hair. Parameters affecting the SPME procedure including type of fiber coating, extraction mode, extraction temperature and time, desorption time, stirring, and salt addition have been evaluated and optimised. The method provided good linearity (r(2)≥0.9980) over the concentration range tested (0.2-20 ng/mg) and low detection limit (0.02 ng/mg). Precision expressed as relative standard deviation was <10%. The average accuracy was 95%. The proposed method was used to determine hair nicotine levels in 100 children in order to assess exposure to environmental tobacco smoke (ETS). The described HS-SPME procedure is fast, simple, sensitive, and solvent-free and is therefore suitable for studies involving ETS exposure assessment.  相似文献   

13.
The simultaneous determination of several odorous trichlorobromophenols in water has been carried out by an in-sample derivatization headspace solid-phase microextraction method (HS-SPME).The analytical procedure involved their derivatization to methyl ethers with dimethyl sulfate/NaOH and further HS-SPME and gas chromatography-mass spectrometry (GC/MS) determination. Parameters affecting both the derivatization efficiency and headspace SPME procedures, such as the selection of the SPME fiber coating, derivatization–extraction time and temperature, were studied. The commercially available polydimethylsiloxane (PDMS) 100 μm and Carboxen-polydimethylsiloxane-divinylbenzene (CAR-PDMS-DVB) fibers appeared to be the most suitable for the simultaneous determination of these compounds. The precision of the HS-SPME/GC/MS method gave good relative standard deviations (RSDs) run-to-run between 9% and 19% for most of them, except for 2,5-diCl-6-Br-phenol, 2,6-diCl-3-Br-phenol and-2,3,6-triBr-phenol (22%, 25% and 23%, respectively). The method was linear over two orders of magnitude, and detection limits were compound dependent but ranged from 0.22 ng/l to 0.95 ng/l. The results obtained for water samples using the proposed SPME procedure were compared with those found with the EPA 625 method, and good agreement was achieved. Therefore, the in-sample derivatization HS-SPME/GC/MS procedure here proposed is a suitable method for the simultaneous determination of odorous trichlorobromophenols in water.  相似文献   

14.
The hyphenated technique namely microwave-assisted headspace solid-phase microextraction (MA-HS-SPME) was developed and studied for the simultaneous extraction/enrichment of polychlorinated biphenyls (PCBs) in aqueous samples prior to the quantification by gas chromatography (GC). The PCBs in aqueous media are extracted onto a solid-phase micro fibre via the headspace with the aid of microwave irradiation. The optimum conditions for obtaining extraction efficiency, such as the extraction time, addition of salts, addition of methanol, ratio of sample to headspace volume, and the desorption parameters were investigated. Experimental results indicated that the proposed MA-HS-SPME method attained the best extraction efficiency under the optimized conditions, i.e., irradiation of extraction solution (20 ml aqueous sample in 40 ml headspace vial with no additions of salt and methanol) under 30 W microwave power for 15 cycles (1 min power on and 3 min power off of each cycle). Desorption at 270 degrees C for 3 min provided the best detection results. The detection limit obtained were between 0.27 and 1.34 ng/l. The correlation coefficient for the linear dynamic range from 1 to 80 ng/l exceeded 0.99 for 18 PCBs.  相似文献   

15.
Simultaneous determination of pyrethroid, organophosphate (OP) and organochlorine (OC) pesticides in water was achieved with headspace solid-phase microextraction (HS-SPME) followed by gas chromatography-electron-capture detection (GC-ECD). The parameters affecting HS-SPME of pesticides from water were optimized, including extraction temperature, sample and headspace volumes, and sodium chloride amounts. The effects of desorption temperature, desorption time, and position of the fibre in the GC inlet were also investigated. Extraction temperature was the most important factor affecting the recoveries of analytes, and the optimized temperature was 96°C. The addition of salt did not increase extraction efficiencies of the pesticides from the water. The optimized desorption conditions in the GC were as follows: desorption time of 10?min; desorption temperature of 260°C; and a 2?cm position of the fibre in the inlet. The method detection limits were in the low-ng/L level with a linearity range of 50–1000?ng/L for the OCs, 50–5000?ng/L for the OP, and 50–20?000?ng/L for the pyrethroids. These data demonstrated that HS-SPME is a sensitive method for the determination of pyrethroid, OC, and OP pesticides in water.  相似文献   

16.
The popular solid phase micro extraction (SPME) device and method is compared with SnifProbe (Gordin and Amirav in J Chromatogr A 903:155–172, 2000) in their application for coffee aroma sampling for its analysis. The main difference between SPME and SnifProbe is in the relative motion of the sampled air. While SPME is based on static air sampling and the achievement of equilibrium, SnifProbe is based on active air pumping through the adsorption trap. A second important difference concerns the sample introduction into the GC injector for its intra injector thermal desorption. SPME is based on the use of a special syringe for sample introduction without any change to the injector, while SnifProbe requires a ChromatoProbe for sample introduction. We found that as a result of these differences, while SnifProbe provides a more faithful (representative) headspace and aroma sample collection, SPME is characterized by major compound dependent sample bias. In addition, SnifProbe enabled much faster sample collection than SPME. Since SnifProbe uses the ChromatoProbe for sample introduction into the GC, bigger sample collection/trapping devices such as silicone tubing can be used, and as a result, over ten times superior SnifProbe sensitivity (versus SPME) was demonstrated. Additional SnifProbe and SPME features are compared and discussed.  相似文献   

17.
A new method for determination of fluoride in toothpaste employing the headspace solid-phase microextraction (HS-SPME) followed by gas chromatography/flame ionization detection (GC/FID) has been proposed. It is a development of the method for determination of fluoride using trimethylchlorosilane (TMCS) as the derivatization reagent to form trimethylfluorosilane (TMFS), with the liquid/liquid extraction (LLE) step replaced by HS-SPME. To introduce the latter, it was necessary to determine the conditions of the reaction and to optimize the two stages of the SPME procedure: extraction and desorption. The parameters of the SPME analysis using carboxen/polydimethylsiloxane (CAR/PDMS) fiber were defined and compared with the corresponding ones for the LLE method, used as a reference. Also, these two methods were compared with respect to their linearity, precision, and accuracy. Results from toothpaste analyses using these two methods were highly correlated, indicating the potential to use the SPME extraction as an inexpensive and solventfree alternative to the LLE method.  相似文献   

18.
A simple, sensitive and rapid method for the determination of diisopropylfluorophosphate (DFP) in rat plasma and brain tissue using headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS) is presented. A 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was selected for sampling. The main parameters affecting the SPME process such as extraction and desorption temperature, extraction and desorption time, salt addition, and fiber preheating time were optimized in each matrix to enhance the extraction efficiency of the method. The lower limits of quantitation for DFP in plasma and brain tissue were 1 ng/mL and 3 ng/g, respectively. The method showed good linearity over the range from 1-100 ng/mL in plasma and 3-300 ng/g in brain tissue with correlation coefficient (R(2)) values higher than 0.995. The precision and accuracy for intra-day and inter-day were less than 10%. The relative recoveries in plasma and brain for DFP were greater than 50%. Stability tests including autosampler and freeze and thaw were also investigated. This validated method was successfully applied to study the neurobehavioral effects of low-level organophosphate exposures. Copyright (c) 2008 John Wiley & Sons, Ltd.  相似文献   

19.
Optimum conditions for headspace solid-phase microextraction (HS-SPME) in the analysis of monomethylmercury (MeHg) have been determined. Sodium tetra(n-)propylborate (NaBPr(4)) is used as derivatization reagent to promote volatility. A simple aluminium bar was used to cool the SPME fiber to about 2 degrees C during the equilibration phase just before extraction. HS-SPME was performed using different fibers. The 100 microm polydimethylsiloxane (PDMS) and 65 microm polydimethylsiloxane-divinylbenzene (PDMS-DVB) fibers showed the best results. Although the extraction efficiency for MeHg derivative of the polydimethylsiloxane-Carboxen (PDMS-CAR) fiber is similar to the other fibers, desorption of MeHg derivative from a PDMS-CAR fiber is poor. Factors affecting the HS-SPME process such as adsorption and desorption times, ionic strength (salting-out) and extraction temperature have been evaluated and optimized thoroughly. The highest extraction efficiency for the PDMS fiber was obtained by extraction at a low temperature (2 degrees C) immediately after equilibration at 30 degrees C. With the PDMS-DVB and PDMS-CAR fiber improvement of extraction efficiency at lower temperatures is negligible. Repeated extraction out of the same vial revealed that about 30% of MeHg derivative is extracted from the headspace with a PDMS fiber at 2 degrees C and about 70% with a PDMS-DVB fiber. Repeated extraction with two different fiber coatings showed that the PDMS-CAR fiber also extracts about 70% but that the desorption is incomplete. Attempts to improve the desorption failed due to degradation of the MeHg derivate at high injection temperatures. The limit of detection (3sigma) was 16 pg/L MeHg. The relative standard deviation (n = 8) for 100 pg/L of MeHg was found to be 5%. Linearity of the HS-SPME-GC-atomic emission detection method was established over at least two orders of magnitude in the range 0-2000 pg/L. Recovery of a surface water sample spiked at 2 ng/L was 85%. The suitability of the procedure was demonstrated by analysis of a surface water sample that showed a concentration of 100 pg/L MeHg. The optimized method can be used with standard commercial equipment without further adaptations.  相似文献   

20.
Wang G  Tang H  Chen D  Feng J  Li L 《色谱》2012,30(2):135-140
建立了香水中5种合成麝香的顶空固相微萃取-气相色谱-质谱联用分析方法。实验选用65 μm的聚二甲基硅氧烷-二乙烯基苯(PDMS-DVB)萃取纤维,在磁力搅拌600 r/min条件下,考察了萃取温度、平衡时间、萃取时间、解吸时间、进样口温度和盐效应6个方面对实验结果的影响。优化后的条件为: 10 mL顶空瓶中加入适量用水稀释过的样品,于60 ℃平衡3 min后,顶空萃取20 min,随即插入气相色谱进样口,于250 ℃解吸3 min进行定性、定量分析。5种合成麝香在0.05~1.00 μg/g范围内线性关系良好,检出限(LOD)为0.6~2.1 ng/g。空白样品在3个浓度加标水平下(0.05, 0.50, 1.00 μg/g)的回收率为82.0%~103.3%,相对标准偏差(RSD)为1.8%~9.4%。本方法简便、准确、快速、灵敏,适用于香水中合成麝香的分析检验工作。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号