首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study we compare on-line gel permeation chromatography (GPC) electrospray ionization (ESI) time-of-flight (TOF) mass spectrometry (MS) to automated GPC matrix assisted laser desorption ionization (MALDI) TOF MS for poly (dimethylsiloxane) (PDMS) analysis. Average mass values for a hydroxyl-terminated PDMS (OH-PDMS) sample were obtained and compared to traditional GPC that was calibrated with narrow polystyrene standards, by direct ESI and MALDI MS analysis, by a summation of mass spectra of all GPC fractions, and also by the recalibration method determined by both mass spectrometric methods. Quantitatively, the difference noted here between these hyphenated techniques is that GPC-ESI-TOF MS effectively reports the low-mass oligomers and underestimates the high-mass oligomers, while GPC-MALDI-TOF MS effectively reports the high-mass oligomers and underestimates the low-mass oligomers. In the GPC-ESI-TOF MS experiments, ion current suppression was observed in the high molecular weight region. The suppression effect was confirmed by repeatable sample runs and by injecting different PDMS samples. Higher chromatographic resolution was observed for GPC-ESI-TOF MS compared to GPC-MALDI-TOF MS. In fact, truly mono-disperse oligomers were observed in the low molecular weight range from GPC-ESI MS experiments.  相似文献   

2.
Mass discrimination effects in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) were quantitatively investigated using equiweight and equimolar mixtures of uniform polystyrene (PS) oligomers. Uniform PS oligomers were separated by preparative super-critical fluid chromatography (SFC) from commercial standard PS samples. The separated PS oligomers, with degrees of polymerization n = 2–25, have absolutely no molecular weight distributions. Equiweight and equimolar mixtures of uniform PS oligomers were accurately prepared by weighing by microbalance, and their spectra were recorded using a MALDI-TOF mass spectrometer. In the lower molecular weight region (less than about 103) the oligomers with lower molecular weights give lower mass spectral intensities, with no correlation with laser power. In contrast, higher laser powers yield a decrease of mass spectral intensities in the higher molecular weight region. These results clearly show that mass discrimination effects occur at lower and higher molecular weights depending on the laser power, and provide quantitative information about the discrimination. Using the data on equiweight and equimolar mixtures of PS oligomers, it was possible to calibrate the MALDI-TOF mass spectral data for an analysis of molecular weight distribution of a standard monodisperse PS sample with number-averaged molecular weight of 103, and to compare it with the molecular weight distribution measured by analytical SFC. The result from the calibrated MALDI-TOF mass spectrum, however, does not agree perfectly with that from the SFC results, because undetectable peaks in MALDI-TOF mass spectra at lower and higher molecular weights could not be included in the calibration of peak intensities. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

3.
Mass measurement accuracy of a reflectron time-of-flight mass spectrometer equipped with delayed extraction is evaluated. Mass resolution of 10,000–15,000 is achieved routinely for peptides in the mass range of 1–6 ku ionized by matrix-assisted laser desorption ionization. The mass measurement accuracy of peptides with molecular weights of 1–4 ku is 10–15 ppm by using external calibration and better than 5 ppm by using internal calibration. The mass calibration remains accurate over a broad mass-to-charge ratio range (1–4 ku), even when the calibration curve is extrapolated several thousand mass units.  相似文献   

4.
For synthetic polymers, a proper sample preparation method is essential for successful characterization by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. In this work, six synthetic mesogen-jacketed liquid crystalline polymers (MJLCPs) with different main-chain, spacer and mesogenic units were investigated by MALDI-TOF mass spectrometry. Several factors that affect the analysis of these polymers were examined. These factors include matrices used, cationization salts used, the concentration of polymers, and the ratio of sample to matrix. After testing different conditions, we found a suitable sample preparation method for these six polymers. The number average molecular weight (M(n)), weight average molecular weight (M(w)) and polydispersity (PD) were calculated using data obtained in the linear mode. The end groups of the polymers were proposed using data obtained in reflectron mode. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

5.
Recently, matrices based on oligomers of dioxin and thiophene (polymer-assisted laser desorption/ionization (PALDI)) have been described for mass spectrometric (MS) analysis of low molecular weight compounds (Woldegiorgis A, von Kieseritzky F, Dahlstedt E, Hellberg J, Brinck T, Roeraade J. Rapid Commun. Mass Spectrom. 2004; 18: 841-852). In this paper, we report the use of PALDI matrices for low molecular weight polymers. An evaluation with polystyrene and polyethylene glycol showed that no charge transfer ionization occurs. Ionization is mediated through metal ion adduction. Comparison of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) data for two very low molecular weight polymers with data obtained from size-exclusion chromatography (SEC) revealed a systematic difference regarding mean molecular weight and dispersity. Further, the mass spectra obtained with PALDI matrices had a higher signal-to-noise ratio than the spectra obtained with conventional matrices. For polymers with higher molecular weights (>1500 Da), the conventional matrices gave better performance. For evaluation of the MALDI spectra, three non-linear mathematical models were evaluated to model the cumulative distributions of the different oligomers and their maximal values of Mw, Mn and PDI. Models based on sigmoidal or Boltzmann equations proved to be most suitable. Objective modeling tools are necessary to compare different sample and instrumental conditions during method optimization of MALDI analysis of polymers, since the bias between MALDI and SEC data can be misleading.  相似文献   

6.
Polyisoprenes (PIPs) with average molecular weights from 650 to 800,000 Da have been studied by time-of-flight secondary ion mass Spectrometry (TOF-SIMS) in the static mode. Polymer samples were bombarded by argon primary ions, and positive SIMS spectra were collected. Effects of branching and unsaturation in the polymer structure on ion formation were studied. The pendant methyl group showed little tendency to fracture as a cation. In the low mass region, CnH 2n–1 + appeared to be more intense than CnH 2n+1 + , attributed to the double bond structure of polyisoprene. Additionally, ion formation varied as a function of polymer molecular weight. Cationized intact oligomers and fragments dominate the high mass region. Oligomer distributions were used to calculate average molecular weights for polyisoprenes. A statistical chain scission mechanism was used to qualitatively explain the formation of five clusters within a unique fragmentation pattern. Detailed studies of the cluster structure pointed out that each cluster contained several species having varied degrees of unsaturation. It is believed that double bond rearrangements occur.  相似文献   

7.
An analytical approach is described for the molecular weight characterization of glucose oligomers from cellulose which had been decomposed by hot-compressed water (HCW). Microcrystalline cellulose was decomposed to 18% of water insoluble fraction (WI) plus 82% of water soluble fraction (WS) by HCW (295 degrees C, 10 mL/min). The glucose oligomers in the WI were analyzed by pericullar anion exchange chromatography, and oligomers longer than pentamers were detected. These results were also confirmed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). Many peaks derived from glucose oligomers with molecular weights less than 4000 Da were detected in the spectra. Mass differences between peaks were 162 Da, as expected for polymers composed of glucose units. This appears to be the first report concerning molecular weight determination of water or organic solvent insoluble compounds like glucose oligomers from cellulose using MALDI-TOFMS.  相似文献   

8.
Electrospray droplet impact (EDI)/secondary ion mass spectrometry (SIMS) is a new desorption/ionization technique for mass spectrometry in which highly charged water clusters produced from the atmospheric‐pressure electrospray are accelerated in vacuum by several kV and impact the sample deposited on the metal substrate. In this study, several industrial synthetic polymers, e.g. polystyrene (PS) and polyethylene glycol (PEG) were analyzed by EDI/SIMS mass spectrometry. For higher molecular weight analytes, e.g. PS4000 and PEG4600, EDI/SIMS mass spectra could be obtained when cationization salts are added. For the polymers of lower molecular weights, e.g. PEG300 and PEG600, they could be readily detected as protonated ions without the addition of cationization agents. Anionized PS was also observed in the negative ion mode of operation when acetic acid was added to the charged droplet. Compared to matrix‐assisted laser desorption/ionization (MALDI), ion signal distribution with lower background signals could be obtained particularly for the low‐molecular weight polymers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
Serum transferrin precipitated with specific antisera was analyzed by matrix-assisted laser desorption ionization/time-of-flight mass spectrometry (MALDI/TOF-MS) and electrospray ionization-mass spectrometry (ESI-MS). When analyzed by MALDI, transferrin showed signal peaks that clearly could be separated from ions of IgG present in the immunoprecipitate. By ESI-MS, when the immunoprecipitates were loaded through a microcapillary polymeric reversed-phase column connected to the electrospray ionization probe, the mass spectra of transferrin were observed with a high signal-to-noise ratio and good resolution. By MALDI/TOF-MS, the observed molecular weight of normal transferrin was ~ 1.2 ku smaller when analyzed in the reflectron mode than in the linear mode. The observed molecular weight of transferrin treated with sialidase was approximately the same in both modes. A comparison between the results obtained in both modes may help to estimate the number of sialic acids on the protein molecule. A transferrin isoform with a molecular weight of ~2.2 ku less than the normal species was identified in the serum of patients with a carbohydrate-deficient glycoprotein syndrome as well as in heavy alcohol consumers.  相似文献   

10.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) of narrowly dispersed molecular weight gel permeation chromatography (GPC) fractions was used to characterize random and microblock poly[(R)-3-hydroxybutyrate-co-epsilon-caprolactone] [P(HB-co-CL)] copolymers obtained via the acid-catalyzed transesterification of the corresponding homopolymers, poly([(R)-3-hydroxybutyrate] (PHB) and poly(epsilon-caprolactone) (PCL). High-quality mass spectra were obtained, which made it possible to establish the nature of the polymer end groups. Besides the carboxylic termination, two other moieties were found: alcoholic and tosyl end groups. MALDI mass spectra of CL-rich samples possessed mostly tosyl end groups, while HB-rich samples possessed mostly alcoholic end groups, showing that the tosyl moiety is linked prevalently to CL terminal units. The higher resolution of electrospray ionization (ESI) mass spectra of lower molecular weight GPC fractions permitted the identification of the different oligomer species hypothesized in the assignment of the corresponding MALDI mass spectra. Partial methanolysis of these copolymers was explored as a method of producing mixed HB-CL oligomers to be utilized as new synthons, possessing a minor number of chiral centers from those obtained from hydrolysis of biotechnologically synthesized poly(hydroxyalkanoates) (PHAs).  相似文献   

11.
The properties and relative ionization efficiencies of a series of polystyrenes (PS) with hydroxyl, hydrogen, tertiary amine, and quaternary amine end-functionalities were examined by matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS). The hydrogen and hydroxyl functionalized PS ionized via attachment of a single Ag(+) cation, as expected. However, tertiary amine PS oligomers were found in (M - H)(+) and (M + H)(+) forms, in addition to M + Ag(+), while the quaternary amine PS oligomers only ionized to the M(+) form. Analysis of tertiary amine PS spectra revealed varying ratios of the three ionic forms depending on the oligomer length, pointing to a change in ionization efficiency. When the bulk samples were compared, the quaternary amine end-functionalized PS gave a ten-fold higher ionization efficiency over all others studied, likely because of the preexisting charge on the functionality. Samples with hydroxyl and hydrogen functionalities had similar ionization efficiencies, with the tertiary amine slightly higher, depending on the molecular weight. Changes in molecular weight affected the relative ionization efficiencies in varying fashion depending on the end functionality, though average molecular weight measurements were largely unaffected by end-functionality. Quantification of end-functionalized polystyrenes with different ionization efficiencies was found to be possible if due care was taken.  相似文献   

12.
The traditional solvent-based matrix-assisted laser desorption ionization (MALDI) preparation method has been used to analyze nonpolar polymers of various molecular weights. High resolution silver cationized oligomers with masses of up to 12 KDa were measured using 9.4 tesla Fourier transform mass spectrometry (FTMS) with an external ionization source. It was observed that when time-of-flight mass spectrometry was used, the spectra of polyethylene polymers showed abundant low mass fragment ions. However, these fragments were absent from the FTMS spectra.  相似文献   

13.
HPLC and gel permeation chromatographic (GPC) characterization of complex phenol-formaldehyde resins is described. Reversed-phase HPLC fingerprints the phenolic monomers, dimers and some oligomers. The molecular masses of these phenolic compounds were determined using an ion trap mass spectrometer. GPC analyzes tetrahydrofuran-soluble phenolic polymers beyond HPLC capability. The molecular mass distribution and structural information of the phenolics was determined by both conventional and laser light-scattering calibration methods. GPC with both UV and refractive index detection provides weight concentration of phenolic resin and the molar concentration of the phenol unit in the oligomers or polymers.  相似文献   

14.
Tao L  Kaddis CS  Loo RR  Grover GN  Loo JA  Maynard HD 《Macromolecules》2009,42(21):8028-8033
Protein-polymer conjugates exhibit superior properties to unmodified proteins, generating a high demand for these materials in the fields of medicine, biotechnology, and nanotechnology. Multimeric conjugates are predicted to surpass the activity of monomeric conjugates. Herein, we report a straightforward method to synthesize multimeric polymer-conjugates. Four armed poly(N-isopropylacrylamide) (pNIPAAm) was synthesized by reversible addition-fragmentation chain transfer (RAFT) polymerization in the presence of a tetra-functionalized trithiocarbonate chain transfer agent (CTA). The polymer molecular weight, architecture and polydispersity index (PDI) were verified by gel permeation chromatography (GPC), dynamic light scattering gel permeation chromatography (DLS-GPC), and matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. This approach afforded well-defined polymers (PDI's < 1.06) and the ability to target various molecular weights. Maleimide functional groups were introduced at the chain ends by heating the polymers in the presence of a furan-protected azo-initiator. This allowed for site-specific conjugation of V131C T4 lysozyme to the polymers to generate multimeric protein-polymer conjugates. MALDI-TOF mass spectrometry, electrospray ionization gas-phase electrophoretic-mobility macromolecule analysis (ESI-GEMMA), gel electrophoresis, and liquid chromatography tandem mass spectrometry (LC-MS/MS) of the trypsin digests demonstrated that multimeric protein-polymer conjugates had formed. This simple strategy provides ready access to star protein-polymer conjugates for application in the fields of drug discovery, drug delivery, and nanotechnology.  相似文献   

15.
Three xylan fractions isolated from the red seaweed Nothogenia fastigiata (Nemaliales) were analyzed by ultraviolet matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (UV-MALDI-TOFMS). UV-MALDI-TOFMS was carried out in the linear and reflectron modes, and as routine in the positive and negative ion modes. Of the several matrices tested, nor-harmane was the only effective one giving good spectra in the positive ion mode. The number-average molar masses of two of the fractions, calculated from the distribution profiles, were lower than those determined previously by (1)H NMR analysis, suggesting a decrease in the ionization efficiency with increasing molecular weight; weight-average molar mass and polydispersity index were also determined. As the xylans retained small but significant quantities of calcium salts, the influence of added Ca(2+) as CaCl(2) on UV-MALDI-MS was investigated. The simultaneous addition of sodium chloride and calcium chloride was also analyzed. Addition of sodium chloride did not change the distribution profile of the native sample showing that the inhibitory effect is due to Ca(2+) and not to Cl(-). Addition of calcium chloride with 1:1 analyte/salt molar ratio gave spectra with less efficient desorption/ionization of oligomers; the signals of these oligomers were completely suppressed when the addition of the salt became massive (1:100 analyte/salt molar ratio).  相似文献   

16.
首先利用高真空活性负离子聚合方法制备聚异戊二烯锂(PI-Li)和(聚苯乙烯-b-聚异戊二烯)锂(PS-PI-Li)活性链,再与单羟基七乙烯基多面体齐聚倍半硅氧烷(VPOSS-OH)发生加成反应,一步法制备2种含羟基的七臂星形聚合物.用分级沉淀法去除低加成产物,即可得到纯的七臂星形聚合物7PI-POSS-OH和7(PS-PI)-POSS-OH,利用凝胶渗透色谱(GPC)、核磁共振波谱(1H-,13C-NMR)、红外光谱(FTIR)和基质辅助激光解吸电离飞行时间质谱(MALDI-TOF MS)表征了聚合物的化学结构、分子量及分子量分布,并通过热失重分析(TGA)测试了聚合物的热分解温度.  相似文献   

17.
This paper reports the development of a new method for quantification of the hydrolytic surface degradation kinetics of biodegradable poly(alpha-hydroxy acid)s using time-of-flight secondary ion mass spectrometry (TOF-SIMS). We report results from static SIMS spectra of a series of poly(alpha-hydroxy acid)s including poly(glycolic acid), poly(L-lactic acid), and random poly(D,L-lactic acid-co-glycolic acid) hydrolyzed in various buffer systems. The distribution of the most intense peak intensities of ions generated in high mass range of the spectrum reflects the intact degradation products (oligomeric hydrolysis products) of each biodegradable polymer. First, a detailed analysis of the oligomeric ions is given based on rearrangement of the intact hydrolysis products. The pattern of ions can distinguish both degradation-generated intact oligomers and their fragment ion peaks with a variety of combinations of each repeat unit. Then, the integration and summation of the area of all ion peaks with the same number of repeat units is proposed as a measurement that provides a more accurate MW average than the typically used method which counts only the most intense peak. The multiple ion summation method described in this paper would be practical in the improvement of quantitative TOF-SIMS studies as a better data reduction method, especially in the surface degradation kinetics of biodegradable polymers.  相似文献   

18.
High-speed gel-permeation chromatography (GPC) of water-soluble polymers has been investigated by using TSK-GEL, type-PW columns packed with small porous particles. Being semirigid, the column packing could be operated under high pressure and, therefore, it was possible to achieve high-speed GPC. A resolution higher than that of ordinary GPC in organic solvent system was attained when the measurement of one sample was completed within 40 min with a 6-ft column set. Samples with a wide range of molecular weights, from oligomers to polymers having a molecular weight greater than 106, could be fractionated. Dextran, polyethylene glycol, polyacrylamide, poly(vinyl alcohol), and poly(vinyl pyrrolidone) were separated according to molecular size with no evidence of adsorption. Investigation of other water soluble polymers is now in progress.  相似文献   

19.
This study reports the characteristic fragmentation patterns from two polysiloxane polymers that form ordered overlayer on silver substrates. Results are compared for the bombardment of various monatomic and polyatomic projectiles of Cs+, C60+ (10 keV), Bi1+, and Bi3+ (25 keV) in the high mass range time-of-flight secondary ion mass spectrometry (TOF-SIMS) spectra. Results are reported from sub-monolayer (solution cast) coverages of poly(dimethylsiloxane)s with the number average molecular weights (Mn) of 2200 and 6140 Da, respectively, and Langmuir-Blodgett monolayers of poly(methylphenylsiloxane) with molecular weights (MW) from 600 and 1000 Da. For each film, Bi projectiles resulted in the emission of positive silver cluster ions from the substrate under the polymer overlayer and peaks corresponding to silver cluster ions with larger mass were observed by impact of polyatomic 25 keV Bi3+ projectiles. In addition, depending on the change of energy of Bi3+, a different pattern of fragments was observed. With Cs+ and C60+ impact, however, the emission of silver cluster ions was not detected. In the case of C60+ impact for PDMS-6140, peaks corresponding to silver-cationized intact oligomers were not observed. In this paper, these results are explained by the possible bombardment mechanism for each projectile, based on its mass, energy, and split trajectories of the component atoms under the polyatomic impact.  相似文献   

20.
Electrospray ionization time-of-flight mass spectrometry (ESI-ToF-MS) has been successfully employed for the characterization of molecular weight, molecular weight distribution and end groups for bromine-terminated perfluoroalkyl acrylate oligomers prepared using atom transfer radical polymerization. Intact oligomers and smaller quantities of common side products were observed from m/z 1000 to 4000 cationized with a sodium ion, a difluorobenzyl cation or a proton with a minimum of multiply charged species. Number average molecular weight and weight average molecular weight for both the samples that were characterized were in reasonable agreement with independent measurements conducted using GPC-MALS and (1)H NMR spectroscopy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号