首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
An algorithm for interpretation of product ion spectra of peptides generated from ion trap mass spectrometry is developed for de novo amino acid sequencing of peptides for the purpose of protein identification. It is based on a multi-pass analysis of product ion data using a rigorous data extraction and sequence interpretation protocol in the initial pass. The extraction/interpretation algorithm becomes more relaxed in subsequent passes, considering more of the fragment ions, and potentially more sequence candidates. The possible peptide sequences generated by the algorithm are scored according to those sequences which best explain the fragment ion spectrum. These sequences are searched against a protein database using a BLAST search engine to find likely protein candidates. The method is also suitable for locating and determining protein modifications, and can be applied to de novo interpretation of peptide fragment ions in the tandem mass (MS/MS) spectrum produced from a mixture of two peptides having similar nominal mass, but different sequences. Using a known protein, bovine serum albumin, as an example, it is illustrated that this method is rapid and efficient for MS/MS spectral interpretation. This method combined with BLAST programs is then applied to search homologies and to generate information on post-translational modifications of an unknown protein isolated from shark cartilage that does not have a complete genome or proteome database.  相似文献   

3.
Berndt P  Hobohm U  Langen H 《Electrophoresis》1999,20(18):3521-3526
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry of protein samples from two-dimensional (2-D) gels in conjunction with protein sequence database searches is frequently used to identify proteins. Moreover, the automatic analysis of complete 2-D gels with hundreds and even thousands of protein spots ("proteome analysis") is possible, without human intervention, with the availability of highly accurate mass spectrometry instruments, and high-throughput facilities for preparation and handling of protein samples from 2-D gels. However, the lack of software for precise automatic analysis and annotation of mass spectra, as well as software for in-batch sequence database queries, is increasingly becoming a significant bottleneck for the proteomics work flow. In the present paper we outline an algorithm for reliable, accurate, and automatic evaluation of mass spectrometric data and database searches. We show here that simply selecting from the sequence database the protein that has the most matching fragment masses often leads to false-positive results. Reliable protein identification is dependent on several parameters: the accuracy of fragment mass determination, the number of masses submitted for query, the mass distribution of query masses, the number of masses matching between sample and database protein, the size of the sequence database, and the kind and number of modifications considered. Using these parameters, we derive a simple statistical estimation that can be used to calculate the probability of true-positive protein identification.  相似文献   

4.
Quadrupole ion trap scanning parameters for performing bottom-up proteomics in a data-dependent fashion were evaluated on a Finnigan LCQ Deca mass spectrometer. Evaluation of parameters such as the number of averaged full scans, the number of averaged MS/MS scans, and ion injection times were necessary for acquiring high quality MS/MS spectra that yield favorable b and y ion coverage and high correlation to proteins using database searching algorithms. In this study, we demonstrated how the duty cycle of the mass spectrometer affects the number of peptides that can be successfully identified by SEQUEST using a model system of tryptic BSA peptides to mimic a typical complex mixture associated with bottom-up proteomics. The number of averaged scans and the duration of ion accumulation in the trap had a significant effect on the quality of acquired MS/MS spectra. For example, by increasing the ion injection time from 500 ms to 600 ms, peptide HLVDEPQNLIK improved from being improperly identified to being correctly identified with a SEQUEST cross-correlation score of 3.60. As a result of these experiments, we have devised the following set of ion trap parameters for performing bottom-up proteomics analysis in our laboratory: Three averaged full scans, five averaged MS/MS scans, and a maximum ion injection time of 600 ms.  相似文献   

5.
Optimized procedures have been developed for the addition of sulfonic acid groups to the N-termini of low-level peptides. These procedures have been applied to peptides produced by tryptic digestion of proteins that have been separated by two-dimensional (2-D) gel electrophoresis. The derivatized peptides were sequenced using matrix-assisted laser desorption/ionization (MALDI) post-source decay (PSD) and electrospray ionization-tandem mass spectrometry methods. Reliable PSD sequencing results have been obtained starting with sub-picomole quantities of protein. We estimate that the current PSD sequencing limit is about 300 fmol of protein in the gel. The PSD mass spectra of the derivatized peptides usually allow much more specific protein sequence database searches than those obtained without derivatization. We also report initial automated electrospray ionization-tandem mass spectrometry sequencing of these novel peptide derivatives. Both types of tandem mass spectra provide predictable fragmentation patterns for arginine-terminated peptides. The spectra are easily interpreted de novo, and they facilitate error-tolerant identification of proteins whose sequences have been entered into databases.  相似文献   

6.
Capillary high-performance liquid chromatography has been coupled on-line with an ion trap storage/reflectron time-of-flight mass spectrometer to perform tandem mass spectrometry for tryptic peptides. Selection and fragmentation of the precursor ions were performed in a three-dimensional ion trap, and the resulting fragment ions were pulsed out of the trap into a reflectron time-of-flight mass spectrometer for mass analysis. The stored waveform inverse Fourier transform waveform was applied to perform ion selection and an improved tickle voltage optimization scheme was used to generate collision-induced dissociation. Tandem mass spectra of various doubly charged tryptic peptides were investigated where a conspicuous y ion series over a certain mass range defined a partial amino acid sequence. The partial sequence was used to determine the identity of the peptide or even the protein by database search using the sequence tag approach. Several peptides from tryptic digests of horse heart myoglobin and bovine cytochrome c were selected for tandem mass spectrometry (MS/MS) where it was demonstrated that the proteins could be identified based on sequence tags derived from MS/MS spectra. This approach was also utilized to identify protein spots from a two-dimensional gel separation of a human esophageal adenocarcinoma cell line.  相似文献   

7.
Different search programs were compared to judge their particular efficiency in protein identification. We established a human blood platelet protein map and identified tyrosine-phosphorylated proteins. The cytosolic fraction of human blood platelets was separated by two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) and phosphorylated proteins were detected by Western blotting using anti-phosphotyrosine antibodies. Visualized protein spots were excised, digested with trypsin and analyzed by matrix assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS). The obtained mass fingerprint data sets have been analyzed using ProFound, MS-Fit and Mascot. For those protein spots with no significant search results MALDI post source decay (PSD) spectra have been acquired on the same sample. For automatic interpretation of these fragment ion spectra, the SEQUEST and Mascot algorithm were applied. Another approach for the identification of phosphorylated proteins is immunoprecipitation using an anti-phosphotyrosine antibody. A method for immunoprecipitation of tyrosine-phosphorylated peptides was optimized.  相似文献   

8.
Recent work on protein and peptide biomarker patterns revealed the difficulties in identifying their molecular components, which is indispensable for validation of the biological context. Cerebrospinal fluid and brain tissue are used as sources to discover new biomarkers, e.g. for neurodegenerative diseases. Many of these biomarker candidates are peptides with a molecular mass of <10 kDa. Their identification is favourably achieved with a 'top-down' approach, because this requires less purification and an enzymatic cleavage will often not yield enough specific fragments for successful database searches. Here, we describe an approach using quadrupole time-of-flight mass spectrometry (TOFMS) as a highly efficient mass spectrometric purification and identification tool after off-line decomplexation of biological samples by liquid chromatography. After initial peptidomic screening with matrix-assisted laser desorption/ionization (MALDI) TOFMS, the elution behaviour in chromatography and the exact molecular mass were used to locate the same signals in nanoelectrospray measurements. Most of the peaks detected in MALDI-TOFMS could be retrieved in nanoelectrospray quadrupole TOFMS. Suitable collision energies for informative fragment spectra were investigated for different parent ions, charge states and molecular masses. After collision-induced dissociation, the resulting fragmentation data of multiply charged ions can become much more complicated than those derived from tryptic peptide digests. However, the mass accuracy and resolution of quadrupole TOF instruments results in high-quality data suitable for determining peptide sequences. The protein precursor, proteolytic processing and post-translational modifications were identified by automated database searches. This is demonstrated by the exemplary identifications of thymosin beta-4 (5.0 kDa) and NPY (4.3 kDa) from rat hypothalamic tissue and ubiquitin (8.6 kDa) from human cerebrospinal fluid. The high data quality should also allow for de novo identification. This methodology is generally applicable for peptides up to a molecular mass of about 10 kDa from body fluids, tissues or other biological sources.  相似文献   

9.
The fragmentation of peptides under laser-induced dissociation (LID) as well as high-energy collision-induced dissociation (CID) conditions has been investigated. The effect of the different fragmentation mechanisms on the formation of specific fragment ion types and the usability of the resulting spectra, e.g. for high-throughput protein identification, has been evaluated. Also, basic investigations on the influence of the matrix, as well as laser fluence, on the fragment ion formation and the consequences in the spectral appearance are discussed. The preconditions for obtaining 'pure' CID spectra on matrix-assisted laser desorption/ionization tandem time-of-flight (MALDI-TOF/TOF) instruments are evaluated and discussed as well as the differences between LID and CID in the resulting fragment ion types. While containing a wealth of information due to additional fragment ions in comparison with LID, CID spectra are significantly more complex than LID spectra and, due to different fragmentation patterns, the CID spectra are of limited use for protein identification, even under optimized parameter settings, due to significantly lower scores for the individual spectra. Conditions for optimal results regarding protein identification using MALDI-TOF/TOF instruments have been evaluated. For database searches using tandem mass spectrometric data, the use of LID as fragmentation technique in combination with parameter settings supporting the use of internal fragment ions turned out to yield the optimal results.  相似文献   

10.
Hu A  Lo AA  Chen CT  Lin KC  Ho YP 《Electrophoresis》2007,28(9):1387-1392
CE-MS/MS analysis of proteolytic digests of bacterial cell extracts was combined with SEQUEST searching and a new scoring system to identify bacteria species in bacterial mixtures. Searches of MS/MS spectra against protein databases enabled the identification of bacterial species by the matching of the proteins associated with the corresponding species. An empirical scoring function was obtained by evaluating the SEQUEST search results of 38 samples that contained single bacterial species. The scoring by the empirical function helped move up the positive identification results from their original positions in the ranking based on Xcorr values alone. Therefore, the identification of bacteria in the samples that contained bacterial mixtures was improved. Bacterial species in 20 bacterial mixtures, including one real sample, were correctly identified by database searches and the new scoring function.  相似文献   

11.
The advantages and disadvantages of acquiring tandem mass spectra by collision-induced dissociation (CID) of peptides in linear ion trap Fourier-transform hybrid instruments are described. These instruments offer the possibility to transfer fragment ions from the linear ion trap to the FT-based analyzer for analysis with both high resolution and high mass accuracy. In addition, performing CID during the transfer of ions from the linear ion trap (LTQ) to the FT analyzer is also possible in instruments containing an additional collision cell (i.e., the "C-trap" in the LTQ-Orbitrap), resulting in tandem mass spectra over the full m/z range and not limited by the ejection q value of the LTQ. Our results show that these scan modes have lower duty cycles than tandem mass spectra acquired in the LTQ with nominal mass resolution, and typically result in fewer peptide identifications during data-dependent analysis of complex samples. However, the higher measured mass accuracy and resolution provides more specificity and hence provides a lower false positive ratio for the same number of true positives during database search of peptide tandem mass spectra. In addition, the search for modified and unexpected peptides is greatly facilitated with this data acquisition mode. It is therefore concluded that acquisition of tandem mass spectral data with high measured mass accuracy and resolution is a competitive alternative to "classical" data acquisition strategies, especially in situations of complex searches from large databases, searches for modified peptides, or for peptides resulting from unspecific cleavages.  相似文献   

12.
Peptide sequencing by mass spectrometry is gaining increasing importance for peptide chemistry and proteomics. However, available tools for interpreting matrix-assisted laser desorption/ionization post-source decay (MALDI-PSD) mass spectra depend on databases, and identify peptides by matching experimental data with spectra calculated from database sequences. This severely obstructs the identification of proteins and peptides not listed in databases or of variations, e.g. mutated proteins. The development of a new computer program for database-independent peptide sequencing by MALDI-PSD mass spectrometry is reported here. This computer program was validated by the determination of the correct sequences for various peptides including sequences listed in the sequence databases, but also for peptides that deviate from database sequences or are completely artificial. This strategy should substantially facilitate the identification of novel or variant peptides and proteins, and increase the power of MALDI-PSD analyses in proteomics.  相似文献   

13.
The use of a high-performance orthogonal time-of-flight (o-TOF) mass spectrometer for sequence analysis is described. The mass spectrometer is equipped with a matrix-assisted laser desorption/ionization (MALDI) source that operates at elevated pressure, 0.01-1 Torr. Ion fragmentation is controlled by varying the pressure of the buffer gas, the laser energy, the voltage difference between the MALDI target and the adjacent sampling cone, and between the cone and the quadrupole ion guide. The peptides were analyzed under optimal ionization conditions to obtain their molecular mass, and under conditions that promote ion dissociation via metastable decomposition or collision-induced dissociation (CID). The fragmentation spectra were used to obtain sequence information. Ion dissociation was promoted via three configurations of the ionization parameters. All methods yielded sequencing-grade b- and y-type ions. Two binary mixtures of peptides were used to demonstrate that: (1) external calibration provides a standard deviation (sigma) of 4 ppm with a mode of 9 ppm; and (2) that peptides with molecular masses that differ by a factor of two may be independently fragmented by appropriately choosing the CID energy and the low-mass cut-off. Analyses of tryptic digests employed liquid chromatography (LC), deposition of the eluant on a target, and finally MALDI-TOF mass spectrometry. The mass fingerprint and the (partial) sequence of the tryptic peptides were matched to their precursor protein via database searches.  相似文献   

14.
The analysis of complex biological peptide mixtures by tandem mass spectrometry (MS/MS) produces a huge body of collision-induced dissociation (CID) MS/MS spectra. Several methods have been developed for identifying peptide-spectrum matches (PSMs) by assigning MS/MS spectra to peptides in a database. However, most of these methods either do not give the statistical significance of PSMs (e.g., SEQUEST) or employ time-consuming computational methods to estimate the statistical significance (e.g., PeptideProphet). In this paper, we describe a new algorithm, RT-PSM, which can be used to identify PSMs and estimate their accuracy statistically in real time. RT-PSM first computes PSM scores between an MS/MS spectrum and a set of candidate peptides whose masses are within a preset tolerance of the MS/MS precursor ion mass. Then the computed PSM scores of all candidate peptides are employed to fit the expectation value distribution of the scores into a second-degree polynomial function in PSM score. The statistical significance of the best PSM is estimated by extrapolating the fitting polynomial function to the best PSM score. RT-PSM was tested on two pairs of MS/MS spectrum datasets and protein databases to investigate its performance. The MS/MS spectra were acquired using an ion trap mass spectrometer equipped with a nano-electrospray ionization source. The results show that RT-PSM has good sensitivity and specificity. Using a 55,577-entry protein database and running on a standard Pentium-4, 2.8-GHz CPU personal computer, RT-PSM can process peptide spectra on a sequential, one-by-one basis in 0.047 s on average, compared to more than 7 s per spectrum on average for Sequest and X!Tandem, in their current batch-mode processing implementations. RT-PSM is clearly shown to be fast enough for real-time PSM assignment of MS/MS spectra generated every 3 s or so by a 3D ion trap or by a QqTOF instrument.  相似文献   

15.
The recent commercial implementation of an electrospray source on a four-sector mass spectrometer has allowed the study of high-energy collisional activation of multiply charged cations. With this configuration, higher mass-to-charge ratios can be accommodated in both precursor ion selection and fragment ion detection. Good mass accuracy facilitates analysis of fragment ions and allows more reliable mechanistic correlation of these fragments. A convenient scheme was devised to permit the use of kilovolt potentials in both MS-I and MS-II, with precursors of varying charge states. Algorithms were devised to assign masses of different types of multiply charged fragment ions. Nine polypeptides were studied in the mass range 2000–5000 Da. Through this entire mass range, fragment ions were observed to be amply formed by cleavages in both the backbone and side chains, analogous to high-energy collisional activation of singly charged ions. This stands in sharp contrast to the patterns reported with low-energy, multiple collisions. Abundances of sequence ion series are influenced by the positions of basic residues. Analysis of charge distributions in fragment ions also indicates that the charges tend to be spread out across the peptides.  相似文献   

16.
New and improved strategies are eagerly sought for the rapid identification of microorganisms, particularly in mixtures. Mass spectrometry remains a powerful tool for this purpose. Small acid-soluble proteins (SASPs), which are relatively abundant in Bacillus spores, represent potential biomarkers for species characterization. Despite sharing extensive sequence homology, these proteins differ sufficiently in sequence for discrimination between species. This work focuses on the differences in sequence between SASPs from various Bacillus species. Compilation of SASP sequences from protein database searches, followed by in silico trypsin digestion and analysis of the resulting fragments, identified several species-specific peptides that could be targeted for analysis using mass spectrometry. This strategy was tested and found to be successful in the characterization of Bacillus spores both from individual species and in mixtures. Analysis was performed using an ion trap mass spectrometer with an atmospheric pressure MALDI source. This instrumentation offers the advantage of increased speed of analysis and accurate precursor ion selection for tandem mass spectrometric analysis compared with vacuum matrix-assisted laser desorption/ionization and time-of-flight instruments. The identification and targeting of species-specific peptides using this type of instrumentation offers a rapid, efficient strategy for the identification of Bacillus spores and can potentially be applied to different microorganisms.  相似文献   

17.
The use of a bis(terpyridine)ruthenium(ii) complex for peptide labeling (Ru-CO labeling) supplied high intensity peaks in mass spectrometry (MS) analysis that overcame the contribution of protonation or sodiated adduction to peptides. Ru-CO-labeled insulin A- and B-chains were detected simultaneously in comparable peak abundance by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The mass spectra of chymotryptic peptide fragments of Ru-CO-labeled insulin also simultaneously indicated both N-terminal fragment ions, and amino acid sequences were determined easily by matrix-assisted laser desorption/ionization post-source-decay (MALDI-PSD). The sensitivity of detecting Ru-CO-labeled peptide fragment ions was not dependent on the length or the sequences of the peptides. The Ru-CO labeling method was applied to tryptic myoglobin fragments. The method indicated that each fragment ion is detected nearly equal in abundance and enabled the desired fragment ions to be distinguished from matrix clusters or their in-source fragments in lower mass regions. The desired fragment ions can be found in the mass region higher than 670.70 (= Ru-CO). This method provided a high sequence coverage (96%) by peptide mass fingerprinting (PMF). Application of this method to a protein mixture (myoglobin, lysozyme and ubiquitin) successfully achieved high sequence-coverage characterization (>90%) of these proteins simultaneously.  相似文献   

18.
Electrospray ionization (ESI) of peptides and proteins produces a series of multiply charged ions with a mass/charge (m/z) ratio between 500 and 2000. The resulting mass spectra are crowded by these multiple charge values for each molecular mass and an isotopic cluster for each nominal m/z value. Here, we report a new algorithm simultaneously to deconvolute and deisotope ESI mass spectra from complex peptide samples based on their mass-dependent isotopic mean pattern. All signals corresponding to one peptide in the sample were reduced to one singly charged monoisotopic peak, thereby significantly reducing the number of signals, increasing the signal intensity and improving the signal-to-noise ratio. The mass list produced could be used directly for database searching. The developed algorithm also simplified interpretation of fragment ion spectra of multiply charged parent ions.  相似文献   

19.
Atmospheric-pressure matrix-assisted laser desorption/ionization (AP-MALDI) ion trap mass spectrometry (ITMS) has been evaluated for automated protein identification. By using signal averaging and long ion-injection times, protein identification limits in the 50-fmol range are achieved for standard protein digests. Data acquisition requires 7.5 min or less per sample and the MS/MS spectra files are automatically processed using the SEQUEST database searching algorithm. AP-MALDI-ITMS was compared with the widely used methods of microLC/MS/MS (ion trap) and automated MALDI-TOF peptide mass mapping. Sample throughput is 10-fold greater using AP-MALDI compared with microcapillary liquid chromatography/tandem mass spectrometry (microLC/MS/MS). The protein sequence coverage obtained from AP-MALDI-MS/MS spectra matched by SEQUEST is lower compared with microLC/MS/MS and MALDI-TOF mass mapping. However, by using the AP-MALDI full-scan peptide mass fingerprint spectrum, sequence coverage is increased. AP-MALDI-ITMS was applied for the analysis of Coomassie blue stained gels and was found to be a useful platform for rapid protein identification.  相似文献   

20.
This paper reports a newly developed technique that uses artificial neural networks to aid in the automated interpretation of peptide sequence from high-energy collision-induced dissociation (CID) tandem mass spectra of peptides. Two artificial neural networks classify fragment ions before the commencement of an iterative sequencing algorithm. The first neural network provides an estimation of whether fragment ions belong to 1 of 11 specific categories, whereas the second network attempts to determine to which category each ion belongs. Based upon numerical results from the two networks, the program generates an idealized spectrum that contains only a single ion type. From this simplified spectrum, the program’s sequencing module, which incorporates a small rule base of fragmentation knowledge, directly generates sequences in a stepwise fashion through a high-speed iterative process. The results with this prototype algorithm, in which the neural networks were trained on a set of reference spectra, suggest that this method is a viable approach to rapid computer interpretation of peptide CID spectra.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号