首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We present a method for the quantitation of glucagon from rat plasma by protein precipitation and LC/MS. No internal standard was used, as a labeled standard was not available and similar peptides did not show comparable extraction characteristics to glucagon. The LC system included a Keystone C18, 300 A pore size column; a linear gradient was used with a mobile phase consisting of water and acetonitrile, each with 0.2% acetic acid and 0.02% trifluoroacetic acid. Glucagon was detected with the mass spectrometer in positive ion mode monitoring the 4+ charge state at m/z 871.7. The method had an approximated limit of detection of 1 ng/mL. The lower limit of quantitation (LLOQ) was 25 ng/mL (7.2 fmol/mL), which could be reduced with an appropriate internal standard. External calibration was used and calibration curves were found to be linear over the range from 25 to 1000 ng/mL (7.2 to 290 fmol/mL). The method showed a high degree of precision and accuracy both within and between runs at four validation points, including the LLOQ.  相似文献   

2.
A simple, sensitive and rapid liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method was developed and validated for simultaneous quantification of olanzapine, clozapine, ziprasidone, haloperidol, risperidone, and its active metabolite 9-hydroxyrisperidone, in rat plasma using midazolam as internal standard (IS). The analytes were extracted from rat plasma using a single step liquid-liquid extraction technique. The compounds were separated on a Waters Atlantis dC-18 (30 mm x 2.1 mm i.d., 3 microm) column using a mobile phase of acetonitrile/5 mM ammonium formate (pH 6.1 adjusted with formic acid) with gradient elution. All of the analytes were detected in positive ion mode using multiple reaction monitoring (MRM). The method was validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recoveries and stability were determined. LLOQ was 0.1 ng/mL and correlation coefficient (R(2)) values for the linear range of 0.1-100 ng/mL were 0.997 or greater for all the analytes. The intra-day and inter-day precision and accuracy were better than 8.05%. The relative and absolute recovery was above 77% and matrix effects were low for all the analytes except for ziprasidone. This validated method has been successfully used to quantify the plasma concentration of the analytes after chronic treatment with antipsychotic drugs.  相似文献   

3.
A sensitive and specific liquid chromatography/mass spectrometry (LC/MS) method has been developed and validated for the quantification of the modified gamma-cyclodextrin Org 25969 and Rocuronium bromide (Roc or Org 9426) in the plasma and urine of guinea pigs. The assay was linear and reproducible over the range 25-10000 ng/mL for both compounds. The lowest limit of quantification (LLOQ) for both compounds in urine was 25 ng/mL. In plasma, the LLOQ was 25 ng/mL for Org 9426 and 50 ng/mL for Org 25969. The inter- and intra-day variation was lower than 20%. The physicochemical properties of both compounds imposed different modes of extraction from plasma. The modified gamma-cyclodextrin was extracted by trifluoroacetic acid (TFA) precipitation while Rocuronium was extracted by acetonitrile precipitation. Both compounds were quantified in urine by direct injection onto the column. The LC/MS analyses of Org 25969 and Org 9426 were performed using two different assay conditions. It was not possible to quantify the complex of cyclodextrin and Roc as it dissociated on the LC column. The use of LC/MS conferred great advantage to the quantification of both Org 25969 and Org 9426, as they were not chromogenic enough to afford the sensitivity and specificity required for the assay.  相似文献   

4.
A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the quantitation of a novel topoisomerase I inhibitor (indolocarbazole derivative I) in human plasma was developed to support clinical studies. Drug and internal standard were isolated from plasma by solid-liquid extraction using 96-well diatomaceous earth plates. Various extraction solvents were evaluated for extraction of I and 9% isopropyl alcohol (IPA) in methyl-tert-butyl ether (MtBE) was chosen as the optimal extraction solvent. The sensitivity of this LC/MS/MS method is 10x higher in negative ion mode using alkaline conditions than in positive ion mode using a wide range of pH's. A mobile phase with 2 mM ammonium hydroxide enhanced the sensitivity in negative ion mode over other volatile bases. The calibration curve for compound I is linear over the range 0.05-200 ng/mL in plasma and the lower limit of quantification (LLOQ) of the assay is 0.05 ng/mL, when 0.25 mL of plasma is processed. The method was fully validated and successfully applied to plasma samples from clinical studies. Performing chromatography at high pH, for enhanced negative ion sensitivity, eliminates the need for post-column addition of base. Furthermore, the 96-well diatomaceous earth plate extraction offers the following advantages over liquid-liquid extraction (LLE) or solid-phase extraction (SPE): clean sample extracts with reduced sample preparation time; increased sample throughput; no conditioning or washing steps; and a neutral eluate applicable to acid/base labile compounds.  相似文献   

5.
A rapid and sensitive assay based on high performance liquid chromatography-tandem mass spectrometry(LC-MS/MS) was developed for the determination of ranitidine(RAN) in human plasma with codeine as internal standard(IS).After protein precipitation with acetonitrile,the analyte and IS were separated on a Zorbax SB-Aq C18 column(150 mm×4.6 mm i.d.,5 μm) eluted with a mobile phase consisting of methanol/acetonitrile/10 mmol/L ammonium acetate containing 1% formic acid(pH=2.4)(volume ratio 12.5:12.5:75) at a flow rate of 1.0 mL/min.Detection was performed by electrospray ionization in the positive ion mode followed by the multiple reaction monito-ring(MRM) of the transitions of RAN at m/z 315.1→176.3 and of IS at m/z 300.1→165.1.The method was linear over a concentration range of 1―1000 ng/mL(r=0.9991) with a lower limit of quantitation(LLOQ) of 1 ng/mL and a limit of detection(LOD) of 0.3 ng/mL.Accuracy as relative error was from-0.01% to-1.7% and intra-day and inter-day precisions as relative standard deviation were ≤8.9% and ≤5.5%,respectively.The method was successfully applied to a pharmacokinetic study of ranitidine,getting a single oral dose(160 mg) to healthy volunteers.  相似文献   

6.
A rapid and simple method for the simultaneous detection and quantitation of amphetamine, methamphetamine, methylenedioxyamphetamine (MDA), methylenedioxymethamphetamine (MDMA) and methylenedioxyethylamphetamine (MDEA) in human serum was developed and fully validated. Serum samples were extracted with cyclohexane, derivatised with perfluorooctanoyl chloride without prior evaporation of the solvent and analysed with gas chromatography-mass spectrometry (GC-MS) in the selected ion monitoring mode (SIM). For quantitation, deuterated analogues were used as the internal standards. The limit of detection (LOD) and lower limit of quantitation (LLOQ), bias and within-day and between-day precision were determined. LODs calculated as the average of the six calibration curves were below 5 ng/mL for all of the measured compounds; LLOQs obtained in the same manner were below 20 ng/mL, with the exception of MDA (24.1 ng/mL). The coefficients of variation were below 7% within series, 10% or less between series and the bias was below 8% for all compounds. The calibration curves were linear between the lower limits of quantitation and 800 ng/mL. Presented in part at 12. Jahrestagung, Deutsche Gesellschaft für Rechtsmedizin, May 2003, Kiel, Germany.  相似文献   

7.
A rapid, simple and fully validated LC‐MS/MS method was developed and validated for the determination of megestrol acetate in human plasma using tolbutamide as an internal standard (IS) after one‐step liquid–liquid extraction with methyl‐tert‐butyl‐ether. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the transitions m/z 385.5 → 267.1 for megestrol acetate and m/z 271.4 → 155.1 for IS. Chromatographic separation was performed on a YMC Hydrosphere C18 column with an isocratic mobile phase, which consisted of 10 mm ammonium formate buffer (adjusted to pH 5.0 with formic acid)–methanol (60:40, v/v) at a flow rate of 0.4 mL/min. The achieved lower limit of quantitation (LLOQ) was 1 ng/mL (signal‐to‐noise ratio > 10) and the standard calibration curve for megestrol acetate was linear (r > 0.99) over the studied concentration range (1–2000 ng/mL). The proposed method was fully validated by determining its specificity, linearity, LLOQ, intra‐ and inter‐day precision and accuracy, recovery, matrix effect and stability. The validated LC‐MS/MS method was successfully applied for the evaluation of pharmacokinetic parameters of megestrol acetate after oral administration of a single dose 800 mg of megestrol acetate (Megace?) to five healthy Korean male volunteers under fed conditions. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

8.
A liquid chromatography/mass spectrometry (LC/MS) analytical procedure, using a single column for sample clean-up, enrichment and separation, has been developed for the determination of the peptide AM336 in monkey cerebrospinal fluid (CSF). CSF samples were injected and analyzed using a polymer-coated mixed-function high-performance liquid chromatography (HPLC) column with gradient elution and application of a timed valve-switching event. The mass spectrometer was operated in the positive electrospray ionization (ESI(+)) mode with single ion recording (SIR) at m/z 920. The method was validated, yielding calibration curves with correlation coefficients greater than 0.9892. Assay precision and accuracy were evaluated by direct injection of AM336-fortified CSF samples at three concentration levels. Analyzed concentrations ranged from 99.93 to 113.1% of their respective theoretical concentrations with coefficients of variation below 9.0%. An evaluation of the signal-to-noise (S/N) ratio for a 200 ng/mL calibration standard, considered to be the lower limit of quantitation (LLOQ), resulted in an estimated limit of detection (LOD) of 31.2 ng/mL. Preliminary data suggest the possibility of using this method to analyze AM336 also in plasma samples, pending the successful outcome of additional investigations.  相似文献   

9.
A liquid chromatographic–tandem mass spectrometric (LC‐MS/MS) method was developed and validated for the determination of GDC‐0834 and its amide hydrolysis metabolite (M1) in human plasma to support clinical development. The method consisted of semi‐automated 96‐well protein precipitation extraction for sample preparation and LC‐MS/MS analysis in positive ion mode using TurboIonSpray® for analysis. D6‐GDC‐0834 and D6‐M1 metabolite were used as internal standards. A linear regression (weighted 1/concentration2) was used to fit calibration curves over the concentration range of 1 – 500 ng/mL for both GDC‐0834 and M1 metabolite. The accuracy (percentage bias) at the lower limit of quantitation (LLOQ) was 5.20 and 0.100% for GDC‐0834 and M1 metabolite, respectively. The precision (CV) for samples at the LLOQ was 3.13–8.84 and 5.20–8.93% for GDC‐0834 and M1 metabolite, respectively. For quality control samples at 3, 200 and 400 ng/mL, the between‐run CV was ≤7.38% for GDC‐0834 and ≤8.20% for M1 metabolite. Between run percentage bias ranged from ?2.76 to 6.98% for GDC‐0834 and from ?6.73 to 2.21% for M1 metabolite. GDC‐0834 and M1 metabolite were stable in human plasma for 31 days at ?20 and ?70°C. This method was successfully applied to support a GDC‐0834 human pharmacokinetic‐based study. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

10.
Amphotericin B (AmB) is one of the most potent antifungal agents and the drug of choice in the treatment of serious fungal infections. A liquid chromatographic (LC) method was developed to determine AmB in pharmaceutical formulations for injection, tissue culture, cream, and lotion. pBondapak C18 reversed-phase column and a simple mobile phase consisting of acetonitrile-water-acetic acid (40 + 54 + 6, v/v) was used. The flow rate was 1.8 mL/min and the effluent was monitored at 405 nm. The developed LC method uses piroxicam as an internal standard and has a limit of detection of 10 ng/mL, a limit of quantitation of 30 ng/mL, and the assay is linear from 0.01 to 100 microg/mL. AmB and piroxicam elute with retention times of 12.4 and 4.0 min, respectively, and the resolution between AmB and piroxicam was 10.6. In comparison with the official United States Pharmacopeia microbial assay for AmB, this LC method is more rapid, selective, sensitive, and offers positive identification.  相似文献   

11.
A simple, sensitive and robust liquid chromatography/electrospray ionization tandem mass spectrometry (LCESI-MS/MS) method with low matrix effects was developed and validated for the quantification of the lipophilic antipsychotic ziprasidone from rat plasma and brain tissue. Ziprasidone was extracted from rat plasma and brain homogenate using a single-step liquid-liquid extraction. Ziprasidone was separated on an Agilent Eclipse XDB C8 column (150 x 2.1 mm i.d., 5 microm) column using a mobile phase of acetonitrile-0.02% ammonia in water (pH 7.20 adjusted with formic acid) using gradient elution. Ziprasidone was detected in the positive ion mode using multiple reaction monitoring. The method was validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recovery, matrix effects and stability were determined. The LLOQ was 0.2 ng/mL for plasma and 0.833 ng/g for brain tissue. The method was linear over the concentration range from 0.2 to 200.0 ng/mL for plasma and 0.833-833.3 ng/g for brain tissue. The correlation coefficient (R2) values were more than 0.996 for both plasma and brain homogenate. The precision and accuracy intra-day and inter-day were better than 8.13%. The relative and absolute recovery was above 81.0% and matrix effects were lower than 5.2%. This validated method has been successfully used to quantify the rat plasma and brain tissue concentration of ziprasidone after chronic treatment.  相似文献   

12.
A sensitive and selective liquid chromatography–tandem mass spectrometry (LC–MS/MS) method was developed and validated for simultaneous determination of urapidil and aripiprazole in human plasma. A simple liquid–liquid extraction with ethyl acetate was used for the sample preparation. Chromatographic separation was achieved on a Phenomenex C18 (4.6 × 50 mm, 5 µm) column with 0.1% formic acid–acetonitrile (10:90, v/v) as the mobile phase with flow rate of 0.6 mL/min. The quantitation of the target compounds was determined in a positive ion multiple reaction monitoring mode. Calibration plots were linear over the range of 2.0–2503.95 ng/mL for urapidil and 1.0–500.19 ng/mL for aripiprazole. The lower limit of quantitation for urapidil and aripiprazole was 2.0 and 1.0 ng/mL, respectively. Mean recovery was in the range of 69.94–75.62% for both analytes and internal standards. Intra‐day and inter‐day precisions of the assay at three concentrations were 2.56–5.89% with accuracy of 92.31–97.83% for urapidil, and 3.14–6.84% with accuracy of 91.38–94.42% for aripiprazole. The method was successfully applied to human pharmacokinetic study of urapidil and aripiprazole in healthy human male volunteers. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

13.
A high-throughput liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) assay using automated sample preparation has been developed for the determination of valproic acid (VPA) in mouse plasma. A liquid-handling system was programmed to prepare calibration standard solutions in plasma, as well as quality controls and clinical samples. Plasma protein precipitation was performed on a 96-well plate, and the collected supernatant was directly injected into a reversed-phase LC/ESI-MS/MS system in the negative ionization mode. The calibration curve for VPA was linear over a dynamic range of 0.15-100 microg/mL. The limit of detection was 75 ng/mL and the lower limit of quantitation was 150 ng/mL. Intra- and inter-day validation assays of the semi-automated plasma analysis showed satisfactory accuracy and precision.  相似文献   

14.
A method using liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the determination of terbinafine in human and minipig plasma has been developed and validated. The method used positive-ion mode for monitoring terbinafine, and used a stable isotope labelled terbinafine as the internal standard. Subsequent to acetonitrile protein precipitation, the supernatant was directly (unfiltered) injected onto the LC column (retention time approximately 4.3 min) for analysis. Interday and intraday accuracy and precision were assessed from the relative recoveries (observed concentration in percent of the nominal value) of spiked samples analyzed on three different days. The lower limit of quantitation (LLOQ) was 0.0679 ng/mL in human and minipig using a plasma sample volume of 0.08 mL. The method was fast, specific, and exhibited ruggedness. Furthermore, the use of turbulent flow chromatography (TurboFlow LC/MS/MS) coupled to mass spectrometry for direct analysis of terbinafine in plasma is discussed. The technique allowed direct introduction of plasma with satisfactory chromatographic peak shape and increased throughput.Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

15.
Docetaxel is an antineoplastic agent widely used in therapeutics. The objective of this study was to develop and validate a routine assay, using liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS), for the simultaneous quantification of docetaxel and its main hydroxylated metabolites in human plasma. A structural analogue, paclitaxel, was used as the internal standard. Determination of docetaxel and four metabolites (M1, M2, M3 and M4) was achieved using only 100 microL of plasma. Liquid-liquid extraction was used for sample preparation, with extraction efficiency of at least 90% for all analytes. Detection used positive-mode electrospray ionization in selected reaction monitoring mode. The lower limit of quantification (LLOQ) was 0.5 ng/mL for all analytes. The assay was linear in the calibration curve range 0.5-1000 ng/mL and acceptable precision and accuracy (<15%) were obtained with concentrations above the LLOQ. This method was sufficiently selective and sensitive for quantification of metabolites in plasma from cancer patients receiving docetaxel chemotherapy, and is suitable for routine analyses during pharmacokinetic studies.  相似文献   

16.
A reliable and easy to use liquid chromatography/tandem mass spectrometry (LC/MS/MS) method without the use of sample extraction was developed for the simultaneous quantification of urinary concentrations of mephenytoin, a standard phenotyping substrate for the cytochrome P450 enzyme CYP2C19, and its phase I metabolites 4'-hydroxymephenytoin and nirvanol. Fifty microL of urine were diluted with a buffered beta-glucuronidase solution and incubated at 37 degrees C for 6 h followed by addition of methanol, containing the internal standard 4'-methoxymephenytoin. The chromatographic separation was achieved using a 100 x 3 mm, 5 micro Thermo Electron Aquasil C18 column with a gradient flow, increasing the organic fraction (acetonitrile/methanol 50:50) of the mobile phase from 10 to 90%. Quantification by triple-stage mass spectrometry (TSQ Quantum, Thermo Electron) was accomplished by negative electrospray ionization in the selected reaction monitoring mode. Linearity was observed for all substances in the concentration range 15-10 000 ng/mL. The lower limit of quantification (LLOQ) was 20 ng/mL for 4'-hydroxymephenytoin and 30 ng/mL for nirvanol and mephenytoin, respectively. Intra- and inter-day inaccuracy did not exceed 9.5% for all substances from LLOQ to 10 000 ng/mL. Intra- and inter-day precision were in the range of 0.8-10.5%. The method was validated according to international ICH and FDA guidelines and successfully applied for phenotyping of Caucasian male volunteers who received an oral dose of 50 mg mephenytoin.  相似文献   

17.
This report describes the development and validation of an LC‐MS/MS method for the quantitative determination of glyburide (GLB), its five metabolites (M1, M2a, M2b, M3 and M4) and metformin (MET) in plasma and urine of pregnant patients under treatment with a combination of the two medications. The extraction recovery of the analytes from plasma samples was 87–99%, and that from urine samples was 85–95%. The differences in retention times among the analytes and the wide range of the concentrations of the medications and their metabolites in plasma and urine patient samples required the development of three LC methods. The lower limit of quantitation (LLOQ) of the analytes in plasma samples was as follows: GLB, 1.02 ng/mL; its five metabolites, 0.100–0.113 ng/mL; and MET, 4.95 ng/mL. The LLOQ in urine samples was 0.0594 ng/mL for GLB, 0.984–1.02 ng/mL for its five metabolites and 30.0 µg/mL for MET. The relative deviation of this method was <14% for intra‐day and inter‐day assays in plasma and urine samples, and the accuracy was 86–114% in plasma, and 94–105% in urine. The method described in this report was successfully utilized for determining the concentrations of the two medications in patient plasma and urine. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
A sensitive and rapid LC‐MS/MS method has been developed and validated for quantifying swertianolin in rat plasma using rutin as an internal standard (IS). Following liquid–liquid extraction with ethyl acetate, chromatographic separation for swertianolin was achieved on a C18 column with a gradient elution using 0.1% formic acid as mobile phase A and acetonitrile as mobile phase B at a flow rate of 0.3 mL/min. The detection was performed on a tandem mass spectrometer using multiple reaction monitoring via an electrospray ionization source and operating in the negative ionization mode. The optimized mass transition ion pairs (m/z) for quantitation were 435.1/272.0 for swertianolin and 609.2/300.1 for IS. The lower limit of quantitation was 0.5 ng/mL within a linear range of 0.5–500 ng/mL. Intra‐day and inter‐day precision was less than 6.8%. The accuracy was in the range of ?13.9 to 12.0%. The mean recovery of swertianolin was >66.7%. The proposed method was successfully applied in evaluating the pharmacokinetics of swertianolin after an oral dose of 50 mg/kg Swertia mussotii extract in rats. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
The first liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of levetiracetam, an antiepileptic drug, in human plasma is described. The plasma filtrate obtained after solid-phase extraction (SPE), using a polymer-based, hydrophilic-lipophilic balanced (HLB) cartridge, was submitted directly to a short column LC/MS/MS assay. There was no significant matrix effect on the analysis. For validation of the method, the recovery of the free analytes was compared to that from an optimized extraction method, and the analyte stability was examined under conditions mimicking sample storage, handling, and analytical procedures. The extraction procedure yielded extremely clean extracts with a recovery of 79.95% and 89.02% for levetiracetam and the internal standard (IS), respectively. The intra-assay and inter-assay precision for the samples at the lower limit of quantitation (LLOQ) were 6.33 and 6.82%, respectively. The calibration curves were linear for the dynamic range of 0.5 to 50 microg/mL with a correlation coefficient r >/= 0.9971. The intra-assay accuracy at LLOQ, LQC, MQC, and HQC levels ranged from 81.60 to 95.40, 93.00 to 103.47, 95.97 to 104.09, and 91.15 to 95.18%, respectively, while the inter-assay accuracy at LLOQ, LQC, MQC and HQC levels varied from 80.20 to 95.40, 88.53 to 107.53, 95.97 to 108.45, and 91.15 to 112.70%, respectively. The method is rugged and fast with a total instrumental run time of 2 min. The method was successfully applied for bioequivalence studies in human subject samples after oral administration of 1000 mg immediate release (IR) formulations.  相似文献   

20.
A rapid analytical method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) using electrospray ionization in negative ion detection mode was developed for the analysis of underivatized iodoacetic acid in water. The method was applied to model reaction mixtures in the study of the formation of iodoacetic acid after chlorinated tap water was boiled in the presence of potassium iodide or iodized table salt. Samples can be directly analyzed by the LC/MS/MS system without extraction or chemical derivatization. Limit of detection was determined to be 0.3 microg/L (or 0.3 ng/mL) and limit of quantitation was about 1 microg/L (1 ng/mL).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号