首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
本文以电热蒸发电感耦合等离子体质谱(ETV-ICP-MS)为手段,探讨了Cr、Ni、Zr、Nb和Yb在石墨炉中的蒸发/原子化机理;比较了不同化学改进剂存在条件下,Cr、Ni、Zr、Nb和Yb的蒸发行为和在石墨炉原子吸收(GFAAS)中的原子化行为;考察了石墨炉温度和ICP功率等实验参数对上述元素发射强度及轮廓的影响.结果表明,Pd和Mg化合物的存在对Cr、Ni、Zr、Nb和Yb的蒸发/原子化行为没有明显的化学改进作用;然而,以聚四氟乙烯(PTFE)为化学改进剂时,可显著改善Cr、Ni、Zr、Nb和Yb的蒸发行为,避免难熔碳化物的形成,降低待测物的蒸发温度;对Cr和Ni的GFAAS信号强度略有增强;但是,由于Yb、Nb和Zr氟化物的离解键能很高,难以离解/原子化,PTFE的存在反而降低了Yb、Nb和Zr在GFAAS中的信号强度.  相似文献   

2.
Fan Z  Hu B  Jiang Z 《Talanta》2006,68(4):1359-1365
Based on gaseous compound introduction as pyrrolidinecarbodithioate chelates of Cr, Co, Mn and Ni by electrothermal vaporization (ETV) in inductively coupled plasma optical emission spectrometry (ICP-OES), a novel method for the determination of trace Cr, Co, Mn and Ni was developed. It was found that in the presence of ammonium pyrrolidinecarbodithioate (APDC) the trace amounts of analytes were vaporized at a low temperature of 1500 °C. The main factors affecting the formation and vaporization of analytes chelates were investigated in detail. Thermal gravimetric analysis of Cr-APDC, Co-APDC, Mn-APDC and Ni-APDC chelates and UV-vis analysis of the sample vapor collected in CHCl3 after vaporization of their chelates indicated that the analytes were vaporized and transported into ICP as their chelates. Under the optimized conditions, the limits of detection (LOD) (3σ) and the relative standard deviations (R.S.D.) of Cr, Co, Mn and Ni were 0.36, 0.19, 0.073 and 0.32 ng, and 3.9, 4.9, 3.8 and 3.3% (c = 0.5 μg ml−1, n = 7), respectively. By combination with a solvent extraction step, the proposed method had been successfully applied to analysis of Cr, Co, Mn and Ni in the artificial seawater. To evaluate the accuracy of the developed method, two certified reference materials (human hair GBW 09101 and poplar leaves GBW 07604) were also analyzed, and the determined values obtained were in good agreement with the certified values.  相似文献   

3.
In this work, tungsten coil (W-Coil) devices are used as atomizers for electrothermal atomization atomic absorption spectrometry (ETAAS), electrothermal atomization laser excited atomic fluorescence spectrometry (ETA-LEAFS), and electrothermal vaporization inductively coupled plasma atomic emission spectrometry (ETV-ICP-AES). For most cases in ETAAS and ETA-LEAFS, limits of detection (LODs) using the W-Coil are within a factor of ten of those observed with commercial graphite furnace systems. LOD for Cd by W-Coil AAS is 10 pg, while LODs for As, Se, Cr, Sb and Pb by W-Coil LEAFS are 950, 320, 1400, 330, and 160 fg, respectively. The compact W-Coil device makes it an ideal atomizer for portable atomic spectrometry instrumentation, especially when coupled with a miniature charge coupled device spectrometer. Alternatively, the atomizer can be used as an inexpensive, modular add-on to an existing commercial ICP-AES system; and the thermal separation of Pb with interference elements Al, Mn, and Fe is demonstrated.  相似文献   

4.
Electrothermal vaporization (ETV) inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS) with polyvinylidene fluoride (PVDF) as chemical modifier are critically compared for the determination of refractory elements in coal fly ash and airborne particulates. The atmospheric particulates that collected on a PVDF filter were introduced into the graphite furnace in the form of a slurry by dissolving the filter in dimethylformamide, and the dissolved filter PVDF, along with additional added PVDF powder, was used as a chemical modifier for subsequent ETV-ICP-OES and ETV-ICP-MS determination. The vaporization behaviors of analytes (Ti, Zr, V, Mo, Cr, La) in ETV-ICP-OES/MS were studied in detail, and the optimal ETV operating parameters were obtained. Under the optimized operating conditions, the detection limits of target elements were 0.08-2.7 ng m(-3) for ETV-ICP-OES and 0.5-50 pg m(-3) for ETV-ICP-MS, respectively, with analytical precisions of 3.5-7.3% for ETV-ICP-OES and 3.9-9.6% for ETV-ICP-MS, respectively. The tolerable amounts of matrix elements for ETV-ICP-OES are higher than for ETV-ICP-MS. Both ETV-ICP-OES and ETV-ICP-MS were used to directly determine the trace refractory elements in coal fly ash and airborne particulates and the analytical results are comparable.  相似文献   

5.
The mechanism of vaporization and atomization of U in a graphite tube electrothermal vaporizer was studied using graphite furnace atomic absorption spectrometry (GFAAS) and electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS). Graphite furnace AAS studies indicate U atoms are formed at temperatures above 2400°C. Using ETV-ICP-MS, an appearance temperature of 1100°C was obtained indicating that some U vaporizes as U oxide. Although U carbides form at temperatures above 2000°C, ETV-ICP-MS studies show that they do not vaporize until 2600°C. In the temperature range between 2200°C and 2600°C, U atoms in GFAAS are likely formed by thermal dissociation of U oxide, whereas at higher temperatures, U atoms are formed via thermal dissociation of U carbide.The origin of U signal suppression in ETV-ICP-MS by NaCl was also investigated. At temperatures above 2000°C, signal suppression may be caused by the accelerated rate of formation of carbide species while at temperatures below 2000°C, the presence of NaCl may cause intercalation of the U in the graphite layers resulting in partial retention of U during the vaporization step. The use of 0.3% freon-23 (CHF3) mixed with the argon carrier gas was effective in preventing the intercalation of U in graphite and U carbide formation at 2700°C.  相似文献   

6.
Slurry sampling followed by electrothermal vaporization was used as sample introduction technique for digestion-free analysis of aluminium nitride and aluminium oxide by inductively coupled plasma atomic emission spectrometry. The vaporizer consisted of a tungsten coil in a quartz chamber. Spectral interferences and background emission caused by tungsten ablation from the coil were reduced by coating it with tungsten carbide. Different approaches for background correction techniques were considered. The analytes Ca, Cd, Co, Cr, Cu, Fe, Mg, Ni and Zn were determined simultaneously, whereas Mn and Na were determined in the sequential mode. Calibration was performed using the standard additions method. The accuracy was checked by comparison of the results with those of independent methods. Detection limits between 0.01 (Mg) and 8.5 μg/g (Co) were achieved. Received: 21 September 1998 / Revised: 30 October 1998 / Accepted: 3 November 1998  相似文献   

7.
Two digestion-free methods for trace analysis of boron nitride based on graphite furnace atomic absorption spectrometry (GFAAS) and electrothermal vaporization inductively coupled plasma spectrometry optical emission (ETV-ICP-OES) using direct solid sampling have been developed and applied to the determination of Al, Ca, Cr, Cu, Fe, Mg, Mn, Si, Ti and Zr in four boron nitride materials in concentration intervals of 1–23, 54–735, 0.05–21, 0.005–1.3, 1.6–112, 4.5–20, 0.03–1.8, 6–46, 38–170 and 0.4–2.3 μg g− 1, respectively. At optimized experimental conditions, with both methods, effective in-situ analyte/matrix separation was achieved and calibration could be performed using calibration curves measured with aqueous standard solutions. In solid sampling GFAAS, before sampling, the platform was covered with graphite powder and, for determination of Si, also the Pd/Mg(NO3)2 modifier was used. In the determination of all analyte elements by solid sampling ETV-ICP-OES, Freon R12 was added to argon carrier gas. For solid sampling GFAAS and ETV-ICP-OES, the achievable limits of detection were within 5 (Cu)–130 (Si) ng g− 1 and 8 (Cu)–200 (Si) ng g− 1, respectively. The results obtained by these two methods for four boron nitride materials of different purity grades are compared each with the other and with those obtained in analysis of digests by ICP-OES. The performance of the two solid sampling methods is compared and discussed.  相似文献   

8.
A macrokinetic theory of the vaporization of a substance based on a consideration of the discrete distribution of a sample and of surface diffusion in the condensed phase has been developed. An analysis of mathematical models describing the vaporization process for the cases of a sample distributed in a porous bulk and over the vaporizer surface revealed several regions. The vaporization rate in these regions depends in different ways on the vaporization rate constant and the diffusion coefficient of the sample in the condensed phase. This offers an opportunity of explaining the appearance of breaks and inflections in the Arrhenius plots as well as of finding the relationship between the activation energies of vaporization in the different regions. The theoretical conclusions are in good agreement with the available and recently obtained data. The macrokinetic theory provided a better understanding of the mechanism of atomization for many elements in the graphite furnace. The macrokinetic theory offers an explanation for many aspects of electrothermal atomic absorption spectrometry associated with the effects of the furnace material and the wall structure, as well as of sample distribution in the furnace on the process of vaporization and, in particular, on the signal shape, sensitivity and matrix interferences.  相似文献   

9.
A method has been developed for the determination of Al, Cd, Cr, Cu, Fe, Mg, Mn, Ni, Sb, Sn and Zn at trace levels in high purity di-boron trioxide using ETAAS. The boron trioxide matrix was eliminated as trimethyl borate ester in a multiplex vapor phase matrix extraction (MVPME) device using a mixture of glycerol and methanol. In this MVPME device, in situ reagent purification, sample digestion and simultaneous matrix elimination were achieved by a single step in closed condition, which in combined effect reduce the process blanks. The matrix extraction procedure allows determination of trace elemental impurities by electrothermal atomic absorption spectrometry (ETAAS) with fast furnace analysis (without an ashing step and modifier) and calibration against aqueous standards. The performance and accuracy of the vapor phase matrix elimination technique are compared to those of suprapur grade hydrofluoric acid solution in two ways; (i) matrix separation as BF3 over hot plate and (ii) in situ matrix elimination inside graphite furnaces. The method detection limits calculated from blank samples are in the range of 0.5 (Ni) and 2.9 (Al) ng g−1. Thus the MVPME-based sample preparation approach is well suited for the trace analysis of high purity di-boron trioxide used in microelectronics applications.  相似文献   

10.
A novel method for the determination of trace rare earth impurities in ZrO2 powder has been developed based on electrothermal vaporization inductively coupled plasma atomic emission spectrometry. A polytetrafluoroethylene slurry was used as a fluorinating reagent to convert both the matrix (Zr) and the analytes (rare earth elements) into fluorides with different volatilities at a high temperature in a graphite furnace. The more volatile ZrF4 was removed in-situ by selective vaporization prior to the determination of the analytes, removing matrix spectral interferences. Under optimum operating conditions, the absolute detection limits of the analytes varied from 0.04 ng (Yb) to 0.50 ng (Pr) with relative standard deviations less than 5%. The recommended approach has been successfully applied to the determination of trace rare earth impurities (La, Pr, Eu, Gd, Ho and Yb) in ZrO2 powder and the results were in good agreement with those obtained by pneumatic nebulization inductively coupled plasma atomic emission spectrometry after the separation of the matrix using a solvent extraction procedure.  相似文献   

11.
Abstract

The use of ammonium acetate (1 mol/l at pH 7) extraction of soils and sediments for the speciation of metal ions is briefly discussed. Because the sensitivity of flame atomic absorption spectrometry (FAAS) is insufficiently sensitive for the determination of many of the heavy metals in ammonium acetate extracts of unpolluted, and even in some polluted soils, the use of electrothermal atomic absorption spectrometry (ETAAS) was studied. A general procedure, using graphite furnace atomisation and the “universal” matrix modifier, palladium, was developed, that was sufficiently sensitive for the determination of Cd, Cr, Cu, Ni, Pb and Zn even in unpolluted soils. The concentration of zinc, however, will almost always be high enough for determination of FAAS and this method is to be preferred to ETAAS for this element.

While, for Cr, Cu, Ni and Pb, direct calibration with external standard solutions is practicable, it is necessary to use the standard additions calibration method for cadmium, to avoid matrix interference effects. The standard additions technique is recommended, however, because it compensates for real differences in the operating parameters of different instruments set to the same nominal values. This is particularly important for interlaboratory comparisons or for certification analyses in the preparation of reference materials.  相似文献   

12.
Slurry sampling followed by electrothermal vaporization was used as sample introduction technique for digestion-free analysis of aluminium nitride and aluminium oxide by inductively coupled plasma atomic emission spectrometry. The vaporizer consisted of a tungsten coil in a quartz chamber. Spectral interferences and background emission caused by tungsten ablation from the coil were reduced by coating it with tungsten carbide. Different approaches for background correction techniques were considered. The analytes Ca, Cd, Co, Cr, Cu, Fe, Mg, Ni and Zn were determined simultaneously, whereas Mn and Na were determined in the sequential mode. Calibration was performed using the standard additions method. The accuracy was checked by comparison of the results with those of independent methods. Detection limits between 0.01 (Mg) and 8.5 μg/g (Co) were achieved.  相似文献   

13.
A new method for the determination of trace amounts of 14 rare earth elements in high purity Y2O3 using fluorination assisted electrothermal vaporization inductively coupled plasma atomic emission spectrometry with slurry sampling was developed. A polytetrafluoroethylene (PTFE) emulsion was used as a fluorinating reagent to promote the vaporization of the analytes from graphite furnace. The main factors affecting analytical signals were investigated systematically. The interference of matrix could be minimized in the presence of PTFE. Under optimum conditions, the detection limits for rare earth elements were 0.032 ng~2.52 ng and the relative standard deviations were in the range of 1.4% to 4.3%. The proposed method was applied to the direct analysis of high purity Y2O3 powder with satisfactory results.  相似文献   

14.
The direct determination of chromium in urine by electrothermal atomic absorption spectrometry (ETAAS) using graphite tubes modified with tungsten is proposed. Modification of the graphite is made by tungsten electrodeposition over the whole surface atomizer followed by carbide formation by heating the tube inside its own furnace. For tungsten electrocoating, the graphite tube and a platinum electrode were connected to a power supply as cathode and anode, respectively, and immersed in a solution containing 2 mg of W in 0.1% v/v HNO3. Then, 5 V was applied between the electrodes during 20 min for tungsten electrodeposition over the whole atomizer. A SpectrAA 220 Varian atomic absorption spectrometer equipped with a deuterium background corrector was used throughout. Undiluted urine (20 μl) was delivered over the tungsten-treated tube and the chromium-integrated absorbance was measured after applying a suitable heating program with maximum pyrolysis at 1300 °C and atomization at 2500 °C. With electrodeposited tungsten modifier, the tube lifetime increased up to four times when compared to previous published methods for Cr determination in urine by ETAAS, reaching 800 firings. Method detection limit (3 S.D.) was 0.10 μg l−1, based on 10 integrated absorbance measurements of a urine sample with low Cr concentration. Two reference materials of urines (SRM 2670) from National Institute of Standards and Technology (NIST) were analyzed for method validation. For additional validation, results obtained from eight human urine samples were also analyzed in a spectrometer with Zeeman effect background correction.  相似文献   

15.
A procedure for the determination of trace elements in human hair has been proposed by electrothermal vaporization inductively coupled plasma optical emission spectrometry (ETV-ICP-OES) with slurry sampling. Slurry was prepared by immersing human hair with conc. HNO3 and then adding a polytetrafluoroethylene (PTFE) slurry, which was used as a chemical modifier for the improvement of vaporization characteristic of analyte. The slurry was homogenized with an ultrasonic vibrator before the measurement. The vaporization behaviour of the analytes in slurry and solution and the main influence factors for the determination were studied with the addition of PTFE systematically. Detection limits for this method varied from 0.033?µg?g?1 (Cu) to 3.21?µg?g?1 (Zn) with the relative standard deviations (RSDs) of 2.8–7.1%. The proposed method was successfully applied for the determination of trace elements (Cu, Mn, Cr, Fe, Zn, Cd and Pb) in human hair with minimum chemical pretreatment and aqueous calibration. The accuracy was checked by comparing the results of this method with those using pneumatic nebulization (PN) ICP-OES after a conventional acid decomposition of the same sample. In addition, the standard reference material of human hair (GBW 07601) was analysed with good agreement between the results from the proposed method and the certified values.  相似文献   

16.
A method has been described for the direct determination of Ti, Cu, Mn, Cr and Cd in solid biological samples without any chemical pretreatment by fluorination assisted electrothermal vaporization inductively coupled plasma atomic emission spectrometry (ETV-ICP-AES) with slurry sampling. A polytetrafluorethylene (PTFE) emulsion was used as a fluorinating reagent to promote the vaporization of the analytes from the graphite furnace. The interface between furnace device and ICP torch and the main factors affecting the analytical signal were investigated systematically. The detection limits for the determination of Ti, Cu, Mn, Cr and Cd are 6.3, 4.7, 10, 13 and 278 ng/mL, respectively; the relative standard deviations are in the range of 1.5 (Mn) ∼4.0% (Cd) after optimization of the operating conditions. The recommended approach has been applied to directly determine the trace elements of interest in the Chinese traditional medicine Loulu and in the solid biological standard reference material (peach leaves, GBW 08501) with satisfactory results. Received: 28 December 1998 / Revised: 9 February 1999 / Accepted: 12 February 1999  相似文献   

17.
A method has been described for the direct determination of Ti, Cu, Mn, Cr and Cd in solid biological samples without any chemical pretreatment by fluorination assisted electrothermal vaporization inductively coupled plasma atomic emission spectrometry (ETV-ICP-AES) with slurry sampling. A polytetrafluorethylene (PTFE) emulsion was used as a fluorinating reagent to promote the vaporization of the analytes from the graphite furnace. The interface between furnace device and ICP torch and the main factors affecting the analytical signal were investigated systematically. The detection limits for the determination of Ti, Cu, Mn, Cr and Cd are 6.3, 4.7, 10, 13 and 278 ng/mL, respectively; the relative standard deviations are in the range of 1.5 (Mn) ∼4.0% (Cd) after optimization of the operating conditions. The recommended approach has been applied to directly determine the trace elements of interest in the Chinese traditional medicine Loulu and in the solid biological standard reference material (peach leaves, GBW 08501) with satisfactory results. Received: 28 December 1998 / Revised: 9 February 1999 / Accepted: 12 February 1999  相似文献   

18.
A sensitive method for the determination of vanadium in water by electrothermal atomisation atomic absorption spectrometry (ETAAS) is described. The vanadium is chelated with 8-hydroxyquinoline in isobutyl methyl ketone and determined by ETAAS after pre-heating the pyrolytic graphite coated graphite tube of a graphite furnace atomiser before injection. The effects of the pH and amount of reagent required for the extraction were studied. The precision, accuracy and interferences of the method were also investigated. The proposed method allows concentrations of vanadium of 0.16 microgram l-1 to be detected.  相似文献   

19.
Carbon tetrachloride vapor as gaseous phase modifier in a graphite furnace electrothermal vaporizer (GFETV) converts heavy volatile analyte forms to volatile and medium volatile chlorides and produces aerosol carrier effect, the latter being a less generally recognized benefit. However, the possible increase of polyatomic interferences in inductively coupled plasma mass spectrometry (GFETV–ICP-MS) by chlorine and carbon containing species due to CCl4 vapor introduction has been discouraging with the use of low resolution, quadrupole type MS equipment. Being aware of this possible handicap, it was aimed at to investigate the feasibility of the use of this halogenating agent in ICP-MS with regard of possible hazards to the instrument, and also to explore the advantages under these specific conditions. With sample gas flow (inner gas flow) rate not higher than 900 ml min−1 Ar in the torch and 3 ml min−1 CCl4 vapor flow rate in the furnace, the long-term stability of the instrument was ensured and the following benefits by the halocarbon were observed. The non-linearity error (defined in the text) of the calibration curves (signal versus mass functions) with matrix-free solution standards was 30–70% without, and 1–5% with CCl4 vapor introduction, respectively, at 1 ng mass of Cu, Fe, Mn and Pb analytes. The sensitivity for these elements increased by 2–4-fold with chlorination, while the relative standard deviation (RSD) was essentially the same (2–5%) for the two cases in comparison. A vaporization temperature of 2650 °C was required for Cr in Ar atmosphere, while 2200 °C was sufficient in Ar + CCl4 atmosphere to attain complete vaporization. Improvements in linear response and sensitivity were the highest for this least volatile element. The pyrolytic graphite layer inside the graphite tube was protected by the halocarbon, and tube life time was further increased by using traces of hydrocarbon vapor in the external sheath gas of the graphite furnace. Details of the modification of the gas supply for HGA-600MS furnace and the design of the volatilization device are described.  相似文献   

20.
The introduction of various forms of molybdenum into an inductively coupled plasma was studied in the vaporization of solutions from a graphite tube. A temperature program is selected that enables the separated vaporization of analytes and molybdenum (matrix) for atomic emission spectrometry with inductively coupled plasma and electrothermal vapoization (ETV–ICP–AES) analysis. The limits of detection for analytes in the ETV–ICP–AES analysis of molybdenum trioxide are evaluated using the fractional separation of analytes and the matrix.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号