1.
Identifying unknown proteins has become a central focal point for proteomic and biopharmaceutical development laboratories. Our laboratory investigated using quadrupole time-of-flight mass spectrometry (Qq/TOFMS) for the analysis of intact proteins for the purpose of identifying unknowns while limiting the number of sample-handling steps between protein extraction and identification. Eight standard proteins, both unmodified and disulfide-bonded and ranging in mass from 5 to 66 kDa, were analyzed using nanoelectrospray and collision-induced dissociation to generate peptide sequence tags. An MS analysis, followed by MS/MS analyses on two to five individual protein charge states, were obtained to make an identification. Peptide sequence tags were extracted from the MS/MS data and used, in conjunction with molecular mass and source origin, to obtain protein identifications using the web-based search engine ProteinInfo (www.proteometrics.com). All of the proteins were unambiguously identified from the input data, after which, all of the major product ions were identified for structural information. In most cases, N- and/or C-terminal ions, and also stretches of consecutive product ions from the protein interior, were observed. This method was applied to the analysis and identification of an unknown detected via reversed-phase high-performance liquid chromatography.  相似文献   

2.
We report a 'top-down' approach for characterization of proteins, and identification of binding sites in protein-drug complexes using nanoelectrospray ionization hybrid quadrupole time-of-flight tandem mass spectrometry (nanoESI-MS/MS). The efficiency of direct fragmentation of intact protein ions and the feasibility of this method were initially demonstrated using several well-characterized proteins with different molecular weights including metallothionein (6126 Da), cytochrome c (horse, 12360 Da), myoglobin (horse, 16592 Da), and hemoglobin (human, 64453 Da). Simply varying collision energy without enzyme digestion and gel or LC separation generated a range of peptide fragments of these proteins. Over 80% of these peptide ions matched those in the SWISS-PROT database with mass accuracy of 8 to 32 ppm with external calibration. This technique was further applied to fragment a cisplatin-metallothionein complex to identify the binding sites, demonstrating a potential application in the study of drug-protein binding.  相似文献   

3.
A two-step mass spectrometric method for characterization of phosphopeptides from peptide mixtures is presented. In the first step, phosphopeptide candidates were identified by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) based on their higher relative intensities in negative ion MALDI spectra than in positive ion MALDI spectra. The detection limit for this step was found to be 18 femtomoles or lower in the case of unfractionated in-solution digests of a model phosphoprotein, beta-casein. In the second step, nanoelectrospray tandem mass (nES-MS/MS) spectra of doubly or triply charged precursor ions of these candidate phosphopeptides were obtained using a quadrupole time-of-flight (Q-TOF) mass spectrometer. This step provided information about the phosphorylated residues, and ruled out nonphosphorylated candidates, for these peptides. After [(32)P] labeling and reverse-phase high-performance liquid chromatography (RP-HPLC) to simplify the mixtures and to monitor the efficiency of phosphopeptide identification, we used this method to identify multiple autophosphorylation sites on the PKR-like endoplasmic reticulum kinase (PERK), a recently discovered mammalian stress-response protein.  相似文献   

4.
Capillary electrophoresis/time-of-flight mass spectrometry(CE/TOFMS) has been used for analysis of in-gel digests of protein spots excised from two-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis (2-D SDS-PAGE). An off-line purification and preconcentration procedure with a Zip Tip is used before CE/TOFMS analysis which allows for detection of protein spots with <1 picomole of material from 2-D gels. The off-line procedure provides sufficient purification for analysis while maintaining the quality of the CE separation. Using this procedure, several proteins from Coomassie Blue and zinc negatively stained gels are identified by the peptide maps generated and database searching. CE/TOF tandem mass spectrometry is used for the confirmation of database searching results and structural analysis of peptides that do not match the expected peptide maps obtained from the database in order to identify structural modifications. Several modifications were pinpointed and identified by this method.  相似文献   

5.
A study has been undertaken to evaluate the usefulness of MALDI Q-TOF data for protein identification. The comparison of MS data of protein digests obtained on a conventional MALDI TOF instrument to the MS data from the MALDI Q-TOF reveal peptide patterns with similar intensity ratios. However, comparison of MS/MS Q-TOF data produced by nanoelectrospray versus MALDI reveals striking differences. Peptide fragment ions obtained from doubly charged precursors produced by nanoelectrospray are mainly y-type ions with some b-ions in the lower mass range. In contrast, peptide fragment ions produced from the singly charged ions originating from the MALDI source are a mixture of y-, b- and a-ions accompanied by ions resulting from neutral loss of ammonia or water. The ratio and intensity of these fragment ions is found to be strongly sequence dependent for MALDI generated ions. The singly charged peptides generated by MALDI show a preferential cleavage of the C-terminal bond of acidic residues aspartic and glutamic acid and the N-terminal bond of proline. This preferential cleavage can be explained by the mobile proton model and is present in peptides that contain both arginine and an acidic amino acid. The MALDI Q-TOF MS/MS data of 24 out of 26 proteolytic peptides produced by trypsin or Asp-N digestions were successfully used for protein identification via database searching, thus indicating the general usefulness of the data for protein identification. De novo sequencing using a mixture of 160/18O water during digestion has been explored and de novo sequences for a number of peptides have been obtained.  相似文献   

6.
Proteins with molecular mass (M(r)) <20 kDa are often poorly separated in 2-D sodium dodecyl sulfate polyacrylamide gel electrophoresis. In addition, low-M(r) proteins may not be readily identified using peptide mass fingerprinting (PMF) owing to the small number of peptides generated in tryptic digestion. In this work, we used a 2-D liquid separation method based on chromatofocusing and non-porous silica reversed-phase high-performance liquid chromatography to purify proteins for matrix-assisted laser desorption/ionization time-of-flight mass spectrometric (MALDI-TOFMS) analysis and protein identification. Several proteins were identified using the PMF method where the result was supported using an accurate M(r) value obtained from electrospray ionization TOFMS. However, many proteins were not identified owing to an insufficient number of peptides observed in the MALDI-TOF experiments. The small number of peptides detected in MALDI-TOFMS can result from internal fragmentation, the few arginines in its sequence and incomplete tryptic digestion. MALDI-QTOFMS/MS can be used to identify many of these proteins. The accurate experimental M(r) and pI confirm identification and aid in identifying post-translational modifications such as truncations and acetylations. In some cases, high-quality MS/MS data obtained from the MALDI-QTOF spectrometer overcome preferential cleavages and result in protein identification.  相似文献   

7.
厉欣  江新宁  邹汉法 《色谱》2008,26(2):189-194
建立了一种基于毛细管反相液相色谱-串联质谱联用技术和质谱峰强度数据处理的肽段鉴定和相对定量分析方法。该方法无需对样品中的肽进行化学标记,在对样品进行反相色谱分离和串联质谱分析后,将二级质谱扫描数据进行蛋白质数据库搜索,获得所鉴定肽段的序列、保留时间、质荷比、带电荷数等定性信息;再以此为定位依据,在全扫描质谱数据中提取该肽段对应的离子峰并以该离子峰的峰强度作为定量信息,从而实现对不同样品中的共有肽段进行差异比较分析。以标准蛋白酶解混合肽段为实验对象,以肽段相对强度的相对标准偏差为指标,考察了该方法用于肽段相对定量分析的重现性、检测动态范围以及浓度标准曲线等,为将该方法用于生物样品中内源性肽的差异分析奠定了基础。  相似文献   

8.
A novel method for peptide sequencing by matrix-assisted laser desorption/ionization mass spectrometry with a time-of-flight/time-of-flight analyzer (MALDI-TOF/TOF) is presented. A stable isotope label introduced in the peptide N-terminus by derivatization, using a 1:1 mixture of acetic anhydride and deuterated acetic anhydride, allows for easy and unambiguous identification of ions belonging either to the N- or the C-terminal ion series in the product ion spectrum, making sequence assignment significantly simplified. The good performance of this technique was shown by successful sequencing of the contents of several peptide maps. A similar approach was recently applied to nanoelectrospray ionization (nanoESI) and nano-liquid chromatography/tandem mass spectrometry (LC/MS/MS). The MALDI-TOF/TOF technique allows for fast, direct sequencing of modified peptides in proteomics samples, and is complementary to the nanoESI and nanoLC/MS/MS approaches.  相似文献   

9.
We present a multidimensional approach to map the composition of complex peptide mixtures obtained as crude extract from biological liquids by (1) cation exchange chromatography and (2) subsequent microbore reversed-phase liquid chromatography and electrospray mass spectrometry coupling (LC-MS). Human hemofiltrate is an equivalent to blood and is used to obtain peptide material in large quantities from patients with chronic renal failure. The upper exclusion limit of the filtration membranes used results in a protein-free filtrate containing peptides in a range up to 20 ku. Using this unique peptide source, several thousand peptides were detected and an LC-MS data base of circulating human peptides was created. The search for known peptides by their molecular mass is a reliable method to guide peptide purification.  相似文献   

10.
The potential of protein fractionation hyphenated to mass spectrometry (MS) to detect and characterize the transgenic protein present in Roundup Ready soya and maize has been investigated. Genetically modified (GM) soya and maize contain the 5-enolpyruvylshikimate-3-phosphate synthase (EPSPS) gene from Agrobacterium tumefaciens CP4, which confers resistance to the herbicide glyphosate. The GM soya and maize proteomes were fractionated by gel filtration, anion-exchange chromatography and sodium dodecyl sulfate/polyacrylamide gel electrophoresis (SDS-PAGE) prior to MS. This facilitated detection of a tryptic peptide map of CP4 EPSPS by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS and nanoelectrospray ionization quadrupole time-of-flight (nanoESI-QTOF) MS. Subsequently, sequence information from the CP4 EPSPS tryptic peptides was obtained by nanoESI-QTOF MS/MS. The identification was accomplished in 0.9% GM soya seeds, which is the current EU threshold for food-labeling requirements.  相似文献   

11.
A novel method is reported for rapid protein identification by the analysis of tryptic peptides using desorption electrospray ionisation (DESI) coupled with hyphenated ion mobility spectrometry and quadrupole time-of-flight mass spectrometry (IMS/Q-ToF-MS). Confident protein identification is demonstrated for the analysis of tryptically digested bovine serum albumin (BSA), with no sample pre-treatment or clean-up. Electrophoretic ion mobility separation of ions generated by DESI allowed examination of charge-state and mobility distributions for tryptic peptide mixtures. Selective interrogation of singly charged ions allowed isobaric peptide responses to be distinguished, along with a reduction in spectral noise. The mobility-selected singly charged peptide responses were presented as a pseudo-peptide mass fingerprint (p-PMF) for protein database searching. Comparative data are shown for electrospray ionisation (ESI) of the BSA digest, without sample clean-up, from which confident protein identification could not be made. Implications for the robustness of the DESI method, together with potential insights into mechanisms for DESI of proteolytic digests, are discussed.  相似文献   

12.
Direct tandem mass spectrometric (MS/MS) analysis of small, singly charged protein ions by tandem time-of-flight mass spectrometry (TOFMS) is demonstrated for proteins up to a molecular mass of 12 kDa. The MALDI-generated singly charged precursor ions predominantly yield product ions resulting from metastable fragmentation at aspartyl and prolyl residues. Additional series of C-terminal sequence ions provide in some cases sufficient information for protein identification. The amount of sample required to obtain good quality spectra is in the high femtomolar to low picomolar range. Within this range, MALDI-MS/MS using TOF/TOF trade mark ion optics now provides the opportunity for direct protein identification and partial characterization without prior enzymatic hydrolysis.  相似文献   

13.
液相色谱/电喷雾质谱(LC/ESI/MS)在蛋白质分析鉴定中的应用   总被引:2,自引:0,他引:2  
对液相色谱/电喷雾质谱(LC/ESI/MS)在蛋白质分子量测定、一级结构的分析、蛋白质和多肽纯度的鉴定、肽质量酶谱、蛋白质分子内二硫键的定量和定位、磷酰化位置的测定以及在蛋白质组中的应用等方面进行了综述和讨论。  相似文献   

14.
The use of a high-performance orthogonal time-of-flight (o-TOF) mass spectrometer for sequence analysis is described. The mass spectrometer is equipped with a matrix-assisted laser desorption/ionization (MALDI) source that operates at elevated pressure, 0.01-1 Torr. Ion fragmentation is controlled by varying the pressure of the buffer gas, the laser energy, the voltage difference between the MALDI target and the adjacent sampling cone, and between the cone and the quadrupole ion guide. The peptides were analyzed under optimal ionization conditions to obtain their molecular mass, and under conditions that promote ion dissociation via metastable decomposition or collision-induced dissociation (CID). The fragmentation spectra were used to obtain sequence information. Ion dissociation was promoted via three configurations of the ionization parameters. All methods yielded sequencing-grade b- and y-type ions. Two binary mixtures of peptides were used to demonstrate that: (1) external calibration provides a standard deviation (sigma) of 4 ppm with a mode of 9 ppm; and (2) that peptides with molecular masses that differ by a factor of two may be independently fragmented by appropriately choosing the CID energy and the low-mass cut-off. Analyses of tryptic digests employed liquid chromatography (LC), deposition of the eluant on a target, and finally MALDI-TOF mass spectrometry. The mass fingerprint and the (partial) sequence of the tryptic peptides were matched to their precursor protein via database searches.  相似文献   

15.
This paper focuses on the sequential steps involved in developing a technique for quantifying Greenland halibut vitellogenin, a serum protein biomarker, using a comprehensive mass spectrometric approach. In the first phase of this study, in‐gel trypsin digestions of serum proteins separated by sodium dodecyl sulphate polyacrylamide gel electrophoresis (SDS‐PAGE) were analyzed by matrix‐assisted laser desorption/ionization mass spectrometry (MALDI‐MS). A characteristic band around a molecular mass of 185 kDa, present in the mature female specimens, but absent in the male samples, was identified as vitellognin according to the peptide mass fingerprint obtained by MALDI‐MS. Subsequently, MALDI and electrospray ionization tandem mass spectrometry (ESI‐MS/MS) analyses were performed on the digest of the vitellogenin band for de novo sequencing. From these studies, a characteristic 'signature' peptide (sequence: FFGQEIAFANIDK) was selected from a list of candidate peptides as a surrogate analytical standard used for quantification purposes. Sample preparation for vitellogenin quantification consisted of a simple one‐step overnight trypsin digestion. Samples were spiked with an isotopologue signature peptide standard and analyzed by high‐performance liquid chromatography (HPLC) coupled in‐line to an electrospray quadrupole‐hexapole‐quadrupole tandem mass spectrometer, operated in selective reaction monitoring mode. Transitions [(m/z 750.0 → 1020.4 and 750.0 → 1205.4) and (754.8 → 1028.6 and 754.8 → 1213.2)] were monitored for the signature peptide and the internal standard, respectively. Samples obtained from the field showed that vitellogenin levels were in accordance with fish maturity determined by macroscopic examination of the gonad, proving this technique suitable for measuring vitellogenin as a serum protein biomarker for reproductive maturity in female fish. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
大气压离子化技术/飞行时间质谱联用进展   总被引:1,自引:0,他引:1  
综述了大气压离子化技术/飞行时间质谱联用技术及其应用的进展  相似文献   

17.
An API 3000 triple-quadrupole instrument and a QSTAR Pulsar quadrupole time-of-flight (TOF) mass spectrometer were compared for the determination of phosphopeptides by precursor ion scanning in both the positive and negative nanoelectrospray ionization modes. The limits of detection for synthetic phosphopeptides were similar (500 amol microl(-1)) for both types of instruments when monitoring precursors of -79 Da (PO(3)(-)). However, the quadrupole TOF system was approximately fivefold more sensitive (1 fmol microl(-1)) than the triple-quadrupole instrument (5 fmol microl(-1)) when monitoring precursors of 216 Da (immonium ion of phosphotyrosine). The recently introduced Q(2)-pulsing function, which enhances the transmission of fragment ions of a selected m/z window from the collision cell into the TOF part, improved the sensitivity of precursor ion scans on a quadrupole TOF instrument. The selectivity of precursor ion scans is much better on quadrupole TOF systems than on triple quadrupoles because the high resolving power of the reflectron-TOF mass analyzer permits high-accuracy fragment ion selection at no expense of sensitivity. This minimizes interferences from other peptide fragment ions (a-, b-, and y- type) of the same nominal mass but with sufficient differences in their exact masses. As a result, the characteristic immonium ion of phosphotyrosine at m/z 216.043 can be utilized for the selective detection of tyrosine phosphorylated peptides. Our data suggest that, in addition to their superior performance for peptide sequencing, quadrupole TOF instruments also offer a very viable alternative to triple quadrupoles for precursor ion scanning, thus combining high sensitivity and selectivity for both MS and MS/MS experiments in one instrument.  相似文献   

18.
A growing number of peptides are being used today in bioanalytical laboratories. Because of this, there is an increasing interest in the development of highly sensitive, specific and robust liquid chromatography/tandem mass spectrometry (LC/MS/MS) assays for the quantitative analysis of peptides in biological samples. Among the mass spectrometers previously used for peptide quantification, triple quadrupole mass spectrometers are generally not considered the instrument of choice. With this instrumentation, collision cascades or multiple fragmentations tend to generate multiple peaks that have weak intensities. This leads to a loss in detection sensitivity. However, in cases where immonium product ions were formed in abundance, it was found that peptide quantification succeeded. A common feature of these peptides is their intra-loop structure. To elucidate the usefulness of this feature in fragmentation, several peptide analytes with intra-chain disulfide bonds were investigated in this study, including a newly synthesized analog having a single amino acid substitution. The results presented here indicate that abrupt bond cleavage from the intra-loop structure of peptides could be one of the premises for intense immonium ion generation. In contrast, any preferential cleavage of peptide bonds (e.g., proline effect) that gives rise to a linearized sequence would break the intactness of the loop and prevent it from completely dissociating. In addition, the utilization of immonium product ions in LC/MS/MS was demonstrated for the determination of peptides with intra-chain disulfide bonds in biological fluids.  相似文献   

19.
The post-translational modifications of the 96 kDa protein dynamin A from Dictyostelium discoideum were analyzed using Q-TOF mass spectrometry. The accurate molecular mass of the intact protein revealed a covalent modification causing an additional mass of 42 Da. The modification could be identified as N-terminal acetylation by tandem mass spectrometry. Extracted ion chromatograms for the a(1) and b(1) ion of the tryptic T1 peptide were used to detect the acetylated peptide within 54 nanoelectrospray ionization tandem mass spectra. Owing to the accurate molecular mass of the intact protein, additional covalent modifications could be excluded. In addition to the covalent modification, the domain structure of dynamin A was determined by applying a combination of limited proteolysis, sodium dodecylsulfate polyacrylamide gel electrophoresis, automated tandem mass spectrometry and protein database searching.  相似文献   

20.
A 193‐nm wavelength deep ultraviolet laser was used for ambient laser ablation electrospray ionization mass spectrometry of biological samples. A pulsed ArF excimer laser was used to ablate solid samples, and the resulting plume of the desorbed material merged with charged electrospray droplets to form ions that were detected with a quadrupole time‐of‐flight mass spectrometer. Solutions containing peptide and protein standards up to 66‐kDa molecular weight were deposited on a metal target, dried, and analyzed. No fragmentation was observed from peptides and proteins as well as from the more easily fragmented vitamin B12 molecule. The mass spectra contained peaks from multiply charged ions that were identical to conventional electrospray. Deep UV laser ablation of tissue allowed detection of lipids from untreated tissue. The mechanism of ionization is postulated to involve absorption of laser energy by a fraction of the analyte molecules that act as a sacrificial matrix or by residual water in the sample.  相似文献   