首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An electrochemical sensor for palytoxin (PlTX) detection, based on a strip of eight screen-printed electrodes connected to a cost-effective and portable apparatus, is reported. Sheep erythrocytes were used to test the palytoxin detector and degree of haemolysis was evaluated by measuring release of the cytosolic lactate dehydrogenase (LDH). Percentage haemolysis and, therefore, the amount of LDH measured, by use of NADH/pyruvate and appropriate electrochemical mediators, was correlated with the concentration of the toxin. Two different electrochemical approaches were investigated for evaluation of LDH release, but only one based on the use of a binary redox mediator sequence (phenazine methosulfate in conjugation with hexacyanoferrate(III)) proved useful for our purpose. After analytical and biochemical characterization, the sensor strip was used to measure palytoxin. Sheep blood and standard solutions of PlTX were left to react for two different incubation times (24 h or 4 h), resulting in working ranges of 7?×?10?3–0.02 ng mL?1 and 0.16–1.3 ng mL?1, respectively. The specificity of the test for palytoxin was evaluated by use of ouabain, which acts in the same way as PlTX on the Na+/K+-ATPase pump. A cross-reactivity study, using high concentrations of other marine biotoxins was also conducted. Experiments to evaluate the matrix effect and recovery from mussels are discussed.
Figure
?  相似文献   

2.
Exhaled breath condensate (EBC) is a promising biofluid scarcely used in clinical analysis despite its non-invasive sampling. The main limitation in the analysis of EBC is the lack of standardized protocols to support validation studies. The aim of the present study was to develop an analytical method for analysis of human EBC by GC–TOF/MS in high resolution mode. Thus, sample preparation strategies as liquid–liquid extraction and solid-phase extraction were compared in terms of extraction coverage. Liquid–liquid extraction resulted to be the most suited sample preparation approach providing an average extraction efficiency of 77% for all compounds in a single extraction. Different normalization approaches were also compared to determine which strategy could be successfully used to obtain a normalized profile with the least variability among replicates of the same sample. Normalization to the total useful mass spectrometry signal (MSTUS) proved to be the most suited strategy for the analysis of EBC from healthy individuals (n = 50) reporting a within-day variability below 7% for the 51 identified compounds and a suited data distribution in terms of percentage of metabolites passing the Skewness and Kurtosis test for normality distribution. The composition of EBC was clearly dominated by the presence of fatty acids and derivatives such as methyl esters and amides, and volatile prenol lipids. Therefore, EBC offers the profile of both volatile and non-volatile components as compared to other similar biofluids such as exhaled breath vapor, which only provides the volatile profile. This human biofluid could be an alternative to others such as serum/plasma, urine or sputum to find potential markers with high value for subsequent development of screening models.  相似文献   

3.
4.
A reproducible, sensitive and selective multiresidue analytical method for seven β-agonists: clenbuterol (CBT), clenpenterol (CPT), ractopamine (RTP), brombuterol (BBT), mabuterol (MBT), mapenterol (MPT), and hydroxymethylclenbuterol (HMCBT) was developed and validated by using liquid chromatography tandem mass spectrometry (LC–MS/MS) in feed and drinking water samples. The validation was achieved according to the criteria laid down in the Commission Decision 2002/657/EC, however it was necessary to use minimum required performance limits (MRPLs) proposed by the Community Reference Laboratories (CRLs) due to the lack of maximum residue limits (MRLs) for β-agonists. By setting up these MRPLs, allows controlling their use in safe mode, since β-agonists are commonly used in veterinary medicine sometime in a fraudulent manner, for increasing the weigh of animals. Values set for both matrices studied are 50 μg/kg for animal feed, and a range from 0.2 to 10 μg/L for drinking water. CCα values calculated were under the MRPLs suggested; for drinking water the lowest value obtained was 0.12 μg/L, and for animal feed 0.87 μg/kg. Values for CCβ were ranged from 0.08 to 0.13 μg/L in drinking water and from 0.5 to 0.92 μg/kg in animal feed samples. The excellence values obtained, allowed us to conclude that the proposed analytical method is capable to control the β-agonists studied in both matrices and that it can be successfully applied and used as a routine method in laboratories of residue analysis of veterinary food control.  相似文献   

5.
This paper describes the development and validation of an analytical methodology to determine eight perfluorinated compounds (PFCs) in edible fish using pressurized liquid extraction (PLE) with water and solid-phase extraction (SPE) with an ion-exchanger as extraction and pre-concentration procedures, followed by liquid chromatography–quadrupole-linear ion trap mass spectrometry (LC–QqLIT–MS). The rapidity and effectiveness of the proposed extraction procedure were compared with those most commonly used to isolate PFCs from fish (ion-pairing and alkaline digestion). The average recoveries of the different fish samples, spiked with the eight PFCs at three levels (the LOQ, 10 and 100 μg kg−1 of each PFC), were always higher than 85% with relative standard deviation (RSD) lower than 17%. A good linearity was established for the eight PFCs in the range from 0.003–0.05 to 100 μg kg−1, with r > 0.9994. The limits of quantification (LOQs) were between 0.003 and 0.05 μg kg−1, which are well below those previously reported for this type of samples. Compared with previous methods, sample preparation time and/or LOQs are reduced. The method demonstrated its successful application for the analysis of different parts of several fish species. Most of the samples tested positive, mainly for perfluoropentanoic acid (PFPA), perfluorobutane sulfonate (PFBS) and perfluorooctanoic acid (PFOA) but other of the eight studied PFCs were also present.  相似文献   

6.
A comparison of different nebulisers for direct hyphenation of capillary and nano liquid chromatography (Cap-LC, Nano-LC) and quadrupole-based collision cell inductively coupled plasma mass spectrometry (CC-ICP–MS) for phosphorylation profiling of tryptic protein digests is described. Helium was used as cell gas and specially tuned instrumental conditions were used to achieve background minimisation at the mass of phosphorus, because of kinetic energy discrimination of the interfering polyatomic ions. The proposed set-up is based on a modified capillary electrophoresis interface and a home-made 4 mL spray chamber. It enables the use of gradient conditions with a highly concentrated organic mobile phase as often used in protein phosphorylation analysis, without the need to apply membrane desolvation for removal of the organic phase or further background minimisation. No significant signal suppression or other negative effects caused by the organic mobile phase occur, because of the low flow rates used in Cap-LC and the robust plasma conditions of the CC-ICP–MS instrument. A tryptic digest of beta-casein was investigated as model compound to demonstrate the applicability of the proposed set-up for phosphorylation profiling in protein analysis using quadrupole based collision-cell ICP–MS as phosphorus-specific detector. Detection limits for phosphorylated peptides down to the sub picomole level were obtained. As a complementary technique, electrospray ionisation tandem mass spectrometry (ESI–MS–MS) with data base searching was used for further characterisation of the phosphorylated peptides detected.  相似文献   

7.
Dabigatran etexilate mesylate (DABE), a prodrug, quickly changes into dabigatran (DAB) after its oral administration. Accordingly, detecting DABE in plasma is practically unmanageable. An ultraperformance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) technique was developed and validated to compute free DAB in participants. For the first time, the central composite design, a type of response surface methodology, was applied for optimizing variables affecting the cleavage of glucuronide bond. In addition, the pharmacokinetic parameters of generic medication (okanadab) were determined, and the obtained outcomes were compared with those of the branded drug (pradaxa). The sample preparation was done using methanol as a protein precipitant and the separation was achieved using an ACQUITY UPLC BEH C18 column (2.1 × 50 mm, 1.7 μm). The elution was isocratically conducted using 10 mM ammonium formate:methanol (72:28, v/v) as a mobile phase and the flow rate was 0.25 mL/min. Multiple reaction monitoring and positive electrospray ionization were used. The determination was performed within 1 min, and the calibration growth curve was established over a range of 1.19–475 ng/mL using DAB-d3 as a tagged internal standard. Bioequivalence research was validated following the US Food and Drug Administration (US FDA) guidelines for bioanalytical procedures and acceptable outcomes were achieved. The outcomes for okanadab and pradaxa did not differ significantly.  相似文献   

8.
In this paper, a novel and recyclable amino-functionalized nano-composite material (NCM) using tetraethylenepentamine (TEPA) as a coupling agent was synthesized. The properties of the TEPA-NCM were characterized by transmission electron microscopy (TEM), Fourier transform infrared analysis (FTIR), thermogravimetric analysis (TGA) and elemental analysis (EA). An effective dispersive solid-phase extraction (dSPE) procedure using the TEPA-NCM was developed, and comparative studies were carried out among Carbon/NH2 SPE, primary secondary amine (PSA) dSPE and TEPA-NCM dSPE. The results showed that TEPA-NCM dSPE was faster, easier and more effective to clean and enrich than the Carbon/NH2 cartridges, and the TEPA-NCM was much more effective to remove the pigments in vegetable samples than the PSA materials. The TEPA-NCM could be reused at least five times without much sacrifice of the cleanup efficiency. Furthermore, a gas chromatography–triple quadrupole mass spectrometry (GC–QqQ-MS/MS) method was established for the simultaneous determination of 29 pesticides (such as organochlorine and organophosphorus pesticides) in vegetables by dSPE using acetonitrile as an extraction solvent and TEPA-NCM as an adsorbent instead of PSA. The recoveries were in the range of 75–114% for all analytes except for trans-chlordane. The RSDs were in the range of 2–17%. The linearities were in the range of 0.4–100.0 μg/kg with determination coefficients (r2) higher than 0.986 for all compounds. The limits of detection (LODs) for all pesticides were less than 0.29 μg/kg and the limits of quantification (LOQs) were between 0.17 and 0.95 μg/kg. The developed method was applied to fifteen real vegetable samples, and it was confirmed that the TEPA-NCM was one of a kind of highly effective dSPE materials used for the pesticides analyses.  相似文献   

9.
Phytosterol oxidation products (POPs) have been suggested to exert adverse biological effects similar to, although less severe than, their cholesterol counterparts. For that reason, their analysis in human plasma is highly relevant. Comprehensive two-dimensional gas chromatography (GC×GC) coupled with time-of-flight mass spectrometry (TOF-MS) has been proven to be an extremely powerful separation technique for the analysis of very low levels of target compounds in complex mixtures including human plasma. Thus, a GC×GC/TOF-MS method was developed and successfully validated for the simultaneous quantification of ten POPs in human plasma. The calibration curves for each compound showed correlation coefficients (R 2) better than 0.99. The detection limits were below 0.1 ng mL−1. The recovery data were between 71.0% and 98.6% (RSDs <10% for all compounds validated). Good results were obtained for within- and between-day repeatability, with most values being below 10%. In addition, non-targeted sterol metabolites were also identified with the method. The concentrations of POPs found in human plasma in the current study are between 0.3 and 4.5 ng mL−1, i.e., 10–100 times lower than the typical values found for cholesterol oxidation products.  相似文献   

10.
Amanitins, highly toxic cyclopeptides isolated from various Amanita species, are the most potent poisons accounting for the hazardous effects on intestinal epithelium cells and hepatocytes, and probably the sole cause of fatal human poisoning.  相似文献   

11.
The enantioseparation of warfarin (WAR) along with the five positional and optical isomers is challenging because of the difficulty to simultaneously separate and quantitate these chiral compounds. Currently, no effective chiral CE–MS methods exist for the simultaneous enantioseparation of WAR and all its hydroxylated metabolites in a single run. Polymeric surfactants (aka. molecular micelles) are particularly compatible with micellar electrokinetic chromatography–mass spectrometry (MEKC–MS) because they have a wider elution window for enantioseparation and do not interfere with the MS detection of chiral drugs. Using polysodium N-undecenoyl-l,l-leucylvalinate (poly-l,l-SULV) as a chiral pseudophase in MEKC–MS baseline separation of WAR, its five metabolites along with the internal standard was obtained in 45 min. This is in comparison to 100 min required for separation of the same mixture with packed column CEC–MS using a vancomycin chiral stationary phase. Serum samples were extracted with mixed-mode anion-exchange (MAX) cartridge with recoveries of greater than 85.2% for all WAR and hydroxywarfarin (OH-WAR) metabolites. Utilizing the tandem MS and multiple reaction monitoring mode, the MEKC–MS/MS method was used to simultaneously generate calibration curves over a concentration range from 2 to 5000 ng/mL for R- and S-warfarin, 5 to 1000 ng/mL for R- and S-6-, 7-, 8- and 10-OH-WAR and 10 to 1000 ng/mL for R and S-4′-OH-WAR. For the first time, the limits of detection and quantitation for most WAR metabolites by MEKC–MS/MS were found to be at levels of 2 and 5 ng/mL, respectively. The method was successfully applied for the first time to analyze WAR and its metabolites in plasma samples of 55 patients undergoing WAR therapy, demonstrating the potential of chiral MEKC–MS/MS method to accurately quantitate with high sensitivity.  相似文献   

12.
13.
The principal trace secondary compounds common to fermentation-derived distilled spirits can be rapidly quantified by directly injecting 5 μL of spirit without sample preparation to a narrow-bore 0.15 mm internal diameter capillary column. The ethanol–water is removed in an initial solvent venting step using a programmed temperature vapourization injector, followed by splitless transfer of the target analytes to the column. The larger injection facilitates trace analysis and ethanol–water removal extends column lifetime. Problems of coelution between analytes or with sample matrix were surmounted by using mass spectral deconvolution software for quantification. All operations in the analysis from injection with solvent venting to data reduction are fully automated for unattended sequential sample analysis. The synergy of the various contributory steps combines to offer an effective novel solution for this analysis. Applications include quantification of low ppm amounts of acids and esters and sub-ppm profiling of trace compounds from both the raw material malt and the ageing in wood barrels.  相似文献   

14.
This study introduced a simple combining apparatus for performing a magnetic stirring-assisted dispersive liquid–liquid microextraction (MSA-DLLME) for the detection of trace carbamate and organophosphorus pesticides in tea drinks coupled with high performance liquid chromatography. The simple combining apparatus was made up of a sample vial and a cut plastic dropper. The bulb end of the cut plastic dropper was inserted into the neck of the sample vial and the open tip end of the plastic dropper was then cut to an appropriate length. The combining apparatus made was then used to perform the MSA-DLLME. In this experiment, 1-octanol was injected into the tea drink sample solution and the extraction process accelerated by magnetic agitation. The sample solution turned clear and separated into two layers after leaving it alone for several minutes. The cut plastic dropper was gently put down into the sample vial, and then the liquid level of the sample solution elevated up to the tip of the plastic dropper for the collection of low-density extractant. Finally, the collected extractant was drawn out by a microsyringe and injected into the high performance liquid chromatography-diode-array detector for analysis. A series of extraction parameters were investigated and optimized. Under the most favorable conditions, high enrichment factors were obtained for carbofuran, carbaryl and isocarbophos (between 130 and 185). The limits of detection (S/N = 3) were in the range of 0.13–0.61 μg L−1, and the relative standard deviation varied below 7.8% (n = 5). Additionally, good recoveries were obtained between 79.4% and 114.4% in the three tea drinks. The simple combining apparatus utilized in this MSA-DLLME method was shown to be economical, fast, and convenient for the collection of low density extractant.  相似文献   

15.
There is substantial evidence that circulating estrogens promote the proliferation of breast cancer. Consequently, adjuvant hormonal treatment strategies targeting estrogen action have been established. Such hormonal therapies include selective estrogen receptor modulators, such as tamoxifen, which interfere at the estrogen receptors directly, or non-steroidal aromatase inhibitors, such as anastrozole and letrozole, which inhibit estrogen synthesis through blocking the aromatase, a key enzyme of estrogen production. Despite considerable therapeutic success, in several cases, the use of these drugs is limited by side effects that have been described to significantly impair the adherence of patients to endocrine treatment. However, objective data concerning patient adherence and its clinical relevance are limited. One promising approach to check patient-reported adherence is drug monitoring in human plasma. Therefore, a liquid chromatography–tandem mass spectrometry method to determine the plasma concentrations of tamoxifen, anastrozole, and letrozole has been developed and fully validated according to guidelines for clinical and forensic toxicology. The validation criteria evaluated were selectivity, linearity, accuracy and precision, limit of quantification, recovery and matrix effects, sample stability, and carryover. The six-point calibration curves showed linearity over the range of concentrations from 25 to 500 ng/ml for tamoxifen, 5 to 200 ng/ml for anastrozole, and 10 to 300 ng/ml for letrozole. The intra- and inter-day precision and accuracies were always better than 15%. The validated procedure was successfully applied to a clinical study (Patient-Reported Outcomes in Breast Cancer Patients undergoing Endocrine Therapy, PRO-BETh). A major aim of PRO-BETh study is the comprehensive evaluation of adherence to treatment in pre- and post-menopausal women with breast cancer. Plasma samples of 310 breast cancer patients undergoing anti-estrogen therapy were analyzed. Eight samples did not contain a quantifiable amount of drug, strongly indicating non-adherence of the corresponding patients to adjuvant breast cancer treatment. Furthermore, plasma concentrations at the lower end of the observed plasma level distribution might represent a hint but not a confirmation for non-adherence in terms of non-daily and irregular intake of the prescribed drug.  相似文献   

16.
The work aims at developing a simple and rapid method for the quantification of dopamine (DA), serotonin (5-HT) and norepinephrine (NE) in human urine. The urinary levels of these biogenic amines can be correlated with several pathological conditions concerning heart disease, stress, neurological disorders and cancerous tumors. The proposed analytical approach is based on the use of solid phase microextraction (SPME) combined with gas chromatography–triple quadrupole mass spectrometry (GC–QqQ-MS) after a fast derivatization of both aliphatic amino and phenolic moieties by propyl chloroformate. The variables influencing the derivatization reaction were reliably optimized by the multivariate approach of “Experimental design”. The optimal conditions were obtained by performing derivatization with 100 μL of propyl chloroformate and 100 μL of pyridine. The extraction ability of five commercially available SPME fibers was evaluated in univariate mode and the best results were obtained using the polyacrylate fiber. The variables affecting the efficiency of SPME analysis were again optimized by the multivariate approach of “Experimental design” and, in particular, a central composite design (CCD) was applied. The optimal values were extraction in 45 min at room temperature, desorption temperature at 300 °C, no addition of NaCl. Assay of derivatized analytes was performed by using a gas chromatography–triple quadrupole mass spectrometry (GC–QqQ-MS) system in selected reaction monitoring (SRM) acquisition. An evaluation of all analytical parameters demonstrates that the developed method provides satisfactory results. Indeed, very good linearities were achieved in the tested calibration range with correlation coefficient values of 0.9995, 0.9999 and 0.9997 for DA, 5-HT and NE, respectively. Accuracies and RSDs calculated for between-run and tested at concentrations of 30, 200, and 800 μg L−1 were in the range from 92.8% to 103.0%, and from 0.67 to 4.5%, respectively. Finally, the LOD values obtained can be considered very good (0.587, 0.381 and 1.23 μg L−1 for DA, 5-HT and NE, respectively).  相似文献   

17.
Cigarette smoke contains several toxic phenolic compounds, measurements of which are essential from a public health standpoint. This article describes a simple and selective analytical method for quantitative determination of six toxic phenolic compounds (phenol, catechol, resorcinol, hydroquinone, o-cresol, and p-cresol) from mainstream cigarette smoke using single-drop microextraction in combination with liquid chromatography–tandem mass spectrometry. Single-drop microextraction was applied prior to analysis by liquid chromatography–tandem mass spectrometry for the extraction and preconcentration of target phenolic compounds from raw cigarette smoke extract. The effects of the extraction solvent, sampling time, solution pH, salt addition, sample agitation rate, and temperature on the extraction efficiency were examined and optimized. The identification of each analyte was established by chromatographic retention times, analyte-specific fragmentation patterns, and relative peak area ratios of two product/precursor ion pairs. Analytical parameters such as the detection limit, relative recovery, reproducibility, linearity, and enrichment factor were evaluated under the optimized experimental conditions. 1-Decanol was selected as the extraction solvent and the limits of detection were found to be in the range of 0.05-0.3 ng mL-1 using an extraction time of 12 min. Gradient chromatographic conditions were optimized for the separation of the six phenolic compounds in a run time of 10 min including reequilibration of the column. The present method for determination of phenolic compounds from mainstream cigarette smoke is simple and specific and shows good reproducibility, with relative standard deviations less than 10 % for all targeted phenolics.
Figure
?  相似文献   

18.
Cardiac glycosides digoxin and digitoxin are used in therapy for the treatment of congestive heart failure. Moreover, these compounds can be responsible for intoxication cases caused by fortuitous ingestion of leaves of Digitalis. Due to the narrow therapeutic range of these drugs, therapeutic drug monitoring is recommended in the clinical practice. In this context, immunoassays-based methods are generally employed but digoxin- and digitoxin-like compounds can interfere with the analysis. The aim of this study was to develop and validate an original UPLC–MS/MS method for the determination of digoxin and digitoxin in plasma. The method shows adequate sensitivity and selectivity with acceptable matrix effects and very good linearity, accuracy, precision, and recovery. A simple liquid–liquid extraction procedure was used for sample clean-up. The method was applied for the analysis of n = 220 plasma samples collected in two different clinical chemistry laboratories and previously tested by the same immunoassay. The statistical comparison showed a relevant negative bias of the UPLC–MS/MS method versus the immunoassay. These results are consistent with an immunoassay overestimation of digoxin plasmatic levels due to cross-reaction events with endogenous digoxin-like substances.  相似文献   

19.
Cordycepin from Cordyceps possesses excellent pharmacological properties, including anti-inflammation and anti-tumor effects, therefore representing a potential alternative medicine. However, doubts about the pharmacokinetic results of cordycepin had been raised in the previous study due to its rapid deamination. The organic solvent methanol was immediately added to terminate the degradation of cordycepin in anticoagulated blood samples and enable the accurate evaluation of pharmacokinetics in vivo. A sensitive and selective ultra-high-performance liquid chromatography coupled with Q Exactive hybrid quadrupole orbitrap high-resolution accurate mass spectrometry method was developed and validated to simultaneously determine cordycepin and its deamination metabolite 3′-deoxyinosine using 2-chloroadenosine as an internal standard in rat whole blood. The calibration curves of cordycepin and 3′-deoxyinosine showed excellent linearity within the concentration range of 1.05–10 000.00 ng/ml with acceptable accuracy, precision, selectivity, recovery, matrix effect, and stability. This method was successfully applied to the pharmacokinetic study of cordycepin and its metabolite in rat blood. The effect of the adenosine deaminase inhibitor erythro-9-(2-hydroxy-3-nonyl) adenine hydrochloride on the pharmacokinetics of cordycepin was investigated. In summary, the reliable pharmacokinetic parameters of cordycepin and its deamination metabolite 3′-deoxyinosine in rat blood were successfully elucidated. Erythro-9-(2-hydroxy-3-nonyl) adenine hydrochloride considerably prolonged the half-life of cordycepin in vivo.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号