首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A glassy carbon electrode (GCE) was modified with electropolymerization of meso-tetrakis(2-aminophenyl)porphyrin (TAPP) in acetonitrile by cyclic voltammetry (CV). The voltammetric behavior of norepinephrine (NE) in the presence of excess ascorbic acid (AA) was investigated at the modified electrode by cyclic and square wave voltammetry (SWV) in phosphate buffer solution. The modified electrode gave higher selectivity and highly effective electroactivity to NE oxidation in voltammetric measurements of NE in the presence of AA and epinephrine. In pH 7.4 phosphate buffer solution, the peak current increased linearly with the concentration of NE in two concentration ranges of 1.0×10−6 to 5.0×10−5 mol dm−3.  相似文献   

2.
A voltammetric method using a poly(1‐methylpyrrole) modified glassy carbon electrode was developed for the quantification of adrenaline. The modified electrode exhibited stable and sensitive current responses towards adrenaline. Compared with a bare GCE, the modified electrode exhibits a remarkable shift of the oxidation potentials of adrenaline in the cathodic direction and a drastic enhancement of the anodic current response. The separation between anodic and cathodic peak potentials (ΔEp) for adrenaline is 30 mV in 0.1 M phosphate buffer solution (PBS) at pH 4.0 at modified glassy carbon electrodes. The linear current response was obtained in the range of 7.5 × 10?7 to 2.0 × 10?4 M with a detection limit of 1.68 × 10?7 M for adrenaline by square wave voltammetry. The poly(1‐methypyrrole)/GCE was also effective to simultaneously determine adrenaline, ascorbic acid and uric acid in a mixture and resolved the overlapping anodic peaks of these three species into three well‐defined voltammetric peaks in cyclic voltammetry. The modified electrode has been successfully applied for the determination of adrenaline in pharmaceuticals. The proposed method showed excellent stability and reproducibility.  相似文献   

3.
The oxidative behaviour of the antidiabetic agent glibenclamide on a bare carbon paste electrode (CPE) and a Sephadex-modified carbon paste electrode (SMCPE) was explored by cyclic and differential pulse voltammetry (DPV). The analysis procedure consisted of an open circuit accumulation step in stirred sample solution of Britton-Robinson buffer (0.04 mol L–1, pH 2.0). This was followed by medium exchange to a clean solution of Britton-Robinson buffer (0.04 mol L–1, pH 5.0), and subsequently an anodic potential scan was effected to obtain the voltammetric peak. The glibenclamide oxidation peak current obtained by DPV was proportional to the concentration of the glibenclamide in the range of 1.0×10–9 mol L–1 to 5.0×10–8 mol L–1 for 180 s accumulation time, with a detection limit of 4.0×10–10 mol L–1. A method was developed for the determination of glibenclamide in formulation and spiked human serum. Moreover, the proposed procedure was used to estimate the serum concentrations after oral administration of a 5 mg tablet of glibenclamide to three diabetic subjects.  相似文献   

4.
Torriero AA  Luco JM  Sereno L  Raba J 《Talanta》2004,62(2):247-254
The electrochemical oxidation of salicylic acid (SA) has been studied on a glassy carbon electrode using cyclic voltammetry and differential pulse voltammetric (DPV) method. SA gives a single irreversible oxidation wave over the wide pH range studied. The irreversibility of the electrode process was verified by different criteria. The mechanism of oxidation is discussed. Using differential pulse voltammetry, SA yielded a well-defined voltammetric response in Britton-Robinson buffer solution, pH 2.37 at 1.088 V (versus Ag/AgCl). The method was linear over the SA concentration range: 1-60 μg ml−1. The method was successfully applied for the analysis of SA as a hydrolysis product, in solid pharmaceutical formulations containing acetylsalicylic acid (ASA).  相似文献   

5.
The electrochemical behavior of L-tyrosine was investigated at a multi-wall carbon nanotubes modified glassy carbon electrode. L-tyrosine itself showed a poor electrochemical response at the bare glassy carbon electrode; however, a multi-wall carbon nanotubes film fabricated on the glassy carbon electrode can directly enhance the electrochemical signal of L-tyrosine when applying cyclic voltammetry and square wave stripping voltammetry without any mediator. Cyclic voltammetry was carried out to study the electrochemical oxidation mechanism of L-tyrosine, which shows a totally irreversible process and an oxidation potential of 671 mV at the modified electrode and 728 mV at the bare electrode, ΔEp = 57 mV. The anodic peak current linearly increases with the square root of scan rate in the low range, suggesting that the oxidation of L-tyrosine on the multi-wall carbon nanotubes modified electrode is a diffusion-controlled process. The square wave stripping voltammetry currents of L-tyrosine at the multi-wall carbon nanotubes modified electrodes increased linearly with the concentration in the range of 2.0 × 10−6–5.0 × 10−4 mol L−1. The detection limit was 4.0 × 10−7 mol L−1. The method is simple, quick, sensitive and accurate.  相似文献   

6.
The electrocatalytic oxidation of cephalexin and cefazolin has been studied at a carbon paste electrode modified with cobalt salophen (CoSal) by cyclic voltammetry. The selectivity of the carbon paste modified with CoSal in detecting cephalexin and cefazolin was examined. To suggest the electrocatalytic mechanism for electro-oxidation of cefazolin, the electrochemical behavior of ceftriaxone was investigated which has a thiol group out of the beta lactam ring. The electrocatalytic oxidation of these antibiotics is shown to be irreversible at the CoSal modified electrode. Scan rate dependence of cefazolin, which is a sulfur-containing compound, has been examined. The results indicated that the electrocatalytic oxidation of the compounds is diffusion controlled. The responses of the modified electrode were compared with those of unmodified electrode and it has shown that the modified electrode has better sensitivity than unmodified electrode to the detection of cefazolin. The overall number of electrons contributed to the oxidation of cefazolin is obtained 1 by chronoamperometry; the number of electron involved in the rate-determining step was 1. The results of differential pulse voltammetry (DPV) using the modified electrode with high sensitivity were applied for the determination of cefazolin in human synthetic serum samples. The linear range was obtained from 1 × 10−5 to 1 × 10−3 M for DPV determination of cefazolin in buffered solutions (pH 3.0).  相似文献   

7.
Glassy carbon electrodes were coated with films of poly(glutamic acid) (PG), and the modified electrode proved to be very effective in the oxidation of caffeic acid. The performance of the film was also tested with ascorbic acid, coumaric acid, ferulic acid, sinapic acid and chlorogenic acid. At pH 5.6, all the hydroxycinnamic acids yield a higher peak current intensity when oxidized after incorporation in the PG-modified electrode, and only the oxidation of ascorbic acid exhibits overpotential reduction. At pH 3.5 only caffeic and chlorogenic acid are incorporated in the modified electrode and exhibit a well-defined oxidation wave at +0.51 V and +0.48 V, which is the base for their determination. Linear calibration graphs were obtained from 9 × 10−6 mol L−1 to 4 × 10−5 mol L−1 caffeic acid by linear voltammetric scan and from 4 × 10−6 mol L−1 to 3 × 10−5 mol L−1 by square wave voltammetric scan. The method was successfully applied to the determination of caffeic acid in red wine samples without interference from other hydroxycinnamic acids or ascorbic acid.  相似文献   

8.
A carbon paste electrode spiked with 1‐[4‐ferrocenyl ethynyl) phenyl]‐1‐ethanone (4FEPE) was constructed by incorporation of 4FEPE in graphite powder‐paraffin oil matrix. It has been shown by direct current cyclic voltammetry and double step chronoamperometry that this electrode can catalyze the oxidation of tryptophan (Trp) in aqueous buffered solution. It has been found that under optimum condition (pH 7.00), the oxidation of Trp at the surface of such an electrode occurs at a potential about 200 mV less positive than at an unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, α and rate constant for the chemical reaction between Trp and redox sites in 4FEPE modified carbon paste electrode (4FEPEMCPE) were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of Trp showed a linear dependent on the Trp concentrations and linear calibration curves were obtained in the ranges of 6.00×10?6 M–3.35×10?3 M and 8.50×10?7 M–6.34×10?5 M of Trp concentration with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods, respectively. The detection limits (3σ) were determined as 1.80×10?6 M and 5.60×10?7 M by CV and DPV methods. This method was also examined as a selective, simple and precise new method for voltammetric determination of tryptophan in real sample.  相似文献   

9.
A polymer film of tetra(p-aminophenyl) porphyrin nickel was obtained at a glassy carbon electrode by a cyclic voltammetric method. Cyclic voltammograms of the film electrode exhibited two stable redox waves with anodic peak potential at 0.43V and cathodic peak potential at 0.30 V in 0.5M NaOH aqueous solution. The electrocatalytic characteristics of the film electrode were studied by cyclic voltammetry, a. c. impedance analysis and other methods. The oxidation peak current increased linearly with the addition of acetaminophen to the aqueous NaOH medium in the range 1 × 10–6–2 × 10–4 M acetaminophen. The performance of the electrode was verified by the determination of acetaminophen in a paracetamol preparation.  相似文献   

10.
A nanogold modified carbon paste electrode (NG‐CPE) was fabricated and used as selective voltammetric sensor for determination of Tartrazine in the presence of Red 10B using cyclic voltammetry (CV), differential pulse voltammetry (DPV), and chronoamperometry (CHA). Electrochemical parameters including the diffusion coefficient (D), the electron transfer coefficient (aXXXXX), and the electron transfer number (n) were determined for the oxidation of Tartrazine. This modified electrode can be applied to simultaneous determination of Tartrazine and Red 10B, because of considerable decreases of anodic overpotentials for both compounds. After optimizing the experimental conditions, the anodic peak current of Tartrazine was linear to its concentration in the range of 0.05‐1.5 μmol l?1, and the detection limit was 0.017 μmol l?1 in phosphate buffer solution (PBS) at pH 4.0. The modified electrode has good stability and repeatability. It was applied to the determination of Tartrazine and Red 10B in soft drinks with satisfactory results.  相似文献   

11.
The electro-oxidation of alternariol monomethyl ether (AME), one of the main metabolites of the Alternaria genus mycotoxins, is studied at 1-dodecanethiol (DDT)-modified gold electrodes, in acetonitrile (ACN) – aqueous phosphate buffer solutions of different pH values, by using cyclic (CV) and square-wave (SWV) voltammetries. The AME voltammetric response at the bare electrode suffers from two drawbacks: it appears at potentials close to the onset of gold oxide formation, and it is hampered by a fouling of the electrode surface due to the accumulation of oxidized products. These shortcomings are circumvented by the use of DDT-coated electrodes, since the intervening monolayer inhibits gold oxide formation and surface passivation by the electrochemical products, without affecting the oxidation kinetics of AME significantly. Diagnostic criteria based on the voltammetric peak parameters show that the electrochemical behavior of AME at the modified electrode is mainly controlled by reactant diffusion from solution, with a weak adsorption of both the mycotoxin and its oxidation products at monolayer defects. Calibration curves were constructed from the AME square-wave voltammetric response and a detection limit of 9.1 × 10−8 mol dm−3 was determined, which is about three times smaller than a previous estimate at platinum and glassy carbon electrodes, and about fifty times smaller than the limit derived from measurements carried out at a polyphenol oxidase-modified carbon paste electrode.  相似文献   

12.
The anodic voltammetric behavior of methotrexate was studied at glassy carbon electrode in acetate buffer (pH = 3.6) solution using cyclic, square-wave voltammetric and chronocoulometric techniques. The oxidation of methotrexate is an irreversible diffusion-controlled process. The oxidation mechanism was proposed and discussed in this work. The dependence of the current on pH, the concentration and nature of buffer, and instrumental parameters were investigated to optimize the experimental conditions for the determination of methotrexate. It was found that in the range of 8.0 × 10−7–2.0 × 10−5 mol/L, the currents measured by square-wave voltammetry presented a good linear property as a function of the concentrations of methotrexate. In addition, validation parameters, such as reproducibility, sensitivity and recovery were evaluated as well. The proposed method was also successfully applied for the determination of methotrexate in diluted human urine with good satisfactory.  相似文献   

13.
The electrocatalytic oxidation of glutathione (GSH) has been studied at the surface of ferrocene-modified carbon paste electrode (FMCPE). Cyclic voltammetry (CV), double potential step chronoamperometry, and differential pulse voltammetry (DPV) techniques were used to investigate the suitability of incorporation of ferrocene into FMCPE as a mediator for the electrocatalytic oxidation of GSH in buffered aqueous solution. Results showed that pH 7.00 is the most suitable for this purpose. In the optimum condition (pH 7.00), the electrocatalytic ability of about 480 mV can be found and the heterogeneous rate constant of catalytic reaction was calculated as . Also, the diffusion coefficient of glutathione, D, was found to be 3.61 × 10–5 cm2 s−1. The electrocatalytic oxidation peak current of glutathione at the surface of this modified electrode was linearly dependent on the GSH concentration and the linear analytical curves were obtained in the ranges of 3.2 × 10–5 M–1.6 × 10–3 M and 2.2 × 10–6 M–3.5 × 10–3 M with cyclic voltammetry and differential pulse voltammetry methods, respectively. The detection limits (3σ) were determined as 1.8 × 10–5 M and 2.1 × 10–6 M using CV and DPV, respectively. Finally, the electrocatalytic oxidation of GSH at the surface of this modified electrode can be employed as a new method for the voltammetric determination of glutathione in real samples such as human plasma.  相似文献   

14.
Summary A new preconcentration and voltammetric determination method for cobalt(II) in aqueous solution with a chemically modified electrode is proposed. The accumulation behaviour and voltammetry of cobalt(II) has been investigated with a carbon paste electrode modified with cationexchanger and 1,10-phenanthroline. The electrochemical response is characterized with respect to carbon paste composition, pH, preconcentration time, cobalt(II) concentration and other variables. For a 3-min preconcentration time, the electrode gives good linearity for 1×10–7 to 4×10–6 mol/l Co(II), a detection limit of 8×10–8 mol/l. The response can be reproduced with a 4.0% relative standard deviation. The method is fairly free from many coexisting ions interferences. A rapid and convenient renewal procedure allows the use of a single electrode in multiple analytical determinations over several days. Satisfactory results are obtained for the determination of cobalt in a variety of certified standard reference materials.  相似文献   

15.
In this study, cyclic and differential pulse voltammetric methods were used to investigate the electrochemical behavior of diazinon at carbon paste electrode modified with tris(ethylenediamine) cobalt(II) iodide ([Co(en)3]I2). Cobalt complex showed an anodic peak at 620 mV (vs. Ag/AgCl, in KNO3 0.1 M as supporting electrolyte) at carbon paste modified electrode. In the presence of diazinon, anodic peak intensity increased with increasing concentration of diazinon that confirmed electrocatalytic activity of cobalt complex for oxidation of diazinon (EC’ mechanism). Under optimized conditions, a linear calibration curve for diazinon was obtained in the range from 0.05 to 27 mg/L with detection limit 0.0075 mg/L (3S b /m). Applications of the modified electrode to the determination of diazinon in different water samples were also tested. The results showed a very good precision (RSD < 0.04%) and very stable voltammetric response towards diazinon.  相似文献   

16.
The preparation and electrochemical characterization of a carbon paste electrode modified with copper(II) hexacyanoferrate(III) (CuHCF) as well as its behavior as electrocatalyst toward the oxidation of N-acetylcysteine were investigated. The electrochemical behavior of the modified electrode and the electrooxidation of N-acetylcysteine were explored using sweep linear voltammetry. The best voltammetric response was observed for a paste composition of 20% (w/w) copper(II) hexacyanoferrate(III) complex, acetate buffer solution at pH of 6.0 as the electrolyte and scan rate of 10 mV s− 1. A linear voltammetric response for N-acetylcysteine was obtained in the concentration range from 1.2 × 10− 4 to 8.3 × 10− 4 mol L− 1, with a detection limit of 6.3 × 10− 5 mol L− 1. The proposed electrode is useful for the quality control and routine analysis of N-acetylcysteine in pharmaceutical formulations.  相似文献   

17.
Voltammetric Determination of Sulfide Ions   总被引:1,自引:0,他引:1  
Procedures were proposed for the voltammetric determination of S2– at a mercury-film electrode. They are based on the oxidation of S2– at –0.79 to –0.80 V and on the reduction of HgS, the product of the oxidation of S2–, at –0.76 to –0.96 V in a 1 M NaOH solution. The anodic and cathodic currents are linear functions of S2– concentration in the ranges from 1 × 10–5 to 1 × 10–4 M and from 2 × 10–6 to 1 × 10–4 M, respectively.  相似文献   

18.
The clay mineral montmorillonite has been tested as modifier for the carbon paste electrode with a novel electrode modification technique. The differential pulse voltammetric determination of copper(II) by means of this modified carbon paste electrode has been studied. A detection limit of 4×10-8 mol/l has been achieved after 10 min preconcentration under open circuit conditions with subsequent anodic stripping voltammetry. The calibration curve for Cu(II) is linear in the range of 4×10-8–8×10-7 mol/l. Pb interferes in a 10-fold molar and Cd and Hg in a 100-fold molar excess. The interference by humic ligands is significant.  相似文献   

19.
《Analytical letters》2012,45(12):1913-1931
Abstract

A voltammetric study of the oxidation of fexofenadine HCl (FEXO) has been carried out at the glassy carbon electrode. The electrochemical oxidation of FEXO was investigated by cyclic, linear sweep, differential pulse (DPV), and square wave (SWV) voltammetry using glassy carbon electrode. The oxidation of FEXO was irreversible and exhibited diffusion‐controlled process depending on pH. The dependence of intensities of currents and potentials on pH, concentration, scan rate, nature of the buffer was investigated. Different parameters were tested to optimize the conditions for the determination of FEXO. For analytical purposes, a very well resolved diffusion‐controlled voltammetric peak was obtained in Britton‐Robinson buffer at pH 7.0 with 20% constant amount of methanol for DPV and SWV techniques. The linear response was obtained in supporting electrolyte in the ranges of 1.0×10?6–2.0×10?4 M with a detection limit of 6.6×10?9 M and 5.76×10?8 M and in serum samples in the ranges of 2.0×10?6–1.0×10?4 M with a detection limit of 8.08×10?8 M and 4.97×10?8 M for differential pulse and square wave voltammetric techniques, respectively. Only square wave voltammetric technique can be applied to the urine samples, and the linearity was obtained in the ranges of 2.0×10?6–1.0×10?4 M with a detection limit of 2.00×10?7 M. Based on this study, simple, rapid, selective and sensitive two voltammetric methods were developed for the determination of FEXO in dosage forms and biological fluids. For the precision and accuracy of the developed methods, recovery studies were used. The standard addition method was used for the recovery studies. No electroactive interferences were found in biological fluids from the endogenous substances and additives present in tablets.  相似文献   

20.
Procedures for the voltammetric determination of rubeanic acid (RA) at a mercury-film electrode were proposed. They are based on the oxidation of RA at –0.70 to –0.80 V or on the reduction of mercury sulfide, the product of RA oxidation, at –0.82 to –0.85 V (versus a saturated silver–silver chloride electrode) in a 1 M NaOH solution. The oxidation and reduction currents are linear functions of RA concentration in the ranges from 9 × 10–6 to 3 × 10–4 M and from 5 × 10–6 to 3 × 10–4 M, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号