首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
张冬辉  周向东  周维善 《中国化学》2002,20(11):1145-1148
Cerebrosterol (2 4S hydroxycholesterol,1)formedinsmallamountsinhumanandanimalbrain1fromcholes terolisimportantforcholesterolhomeostasisinthisorgan .Theexcesscholesterolisconvertedinto 2 4S hydroxy cholesterolbyauniquebrain specific 2 4S hydroxylase ,whichcouldber…  相似文献   

2.
Dose-dependent pharmacokinetics of glycyrrhizin in rats.   总被引:3,自引:0,他引:3  
The dose-dependent pharmacokinetics of glycyrrhizin (GLZ) was investigated by measuring drug disappearance from plasma and biliary excretion in rats. The decline in plasma concentration was biexponential after an i.v. dose of 5, 10, 20, or 50 mg/kg. Dosage, however, had a marked effect on the pharmacokinetics, with a greater-than-proportional increase in area under the plasma concentration curve (AUC) at doses of 20 and 50 mg/kg, even though the increase was proportional at doses of 5 and 10 mg/kg. There was also a significant increase of the steady-state distribution volume (Vdss), as well as significant decreases in total body (CLtot) and biliary (CLB) clearances, at 20 and 50 mg/kg from those at 5-10 and 5-20 mg/kg, respectively. The AUC, Vdss, and renal clearance (CLR) at a given dose showed no significant difference between rats with and without bile fistulas. The plasma unbound fraction (fp) (0.006-0.026) increased with increasing plasma GLZ concentration over the observed range (2-900 micrograms/ml). No significant change in Vdss for unbound GLZ was observed between the doses, indicating that the distribution of GLZ into tissues is not changed by an increase in dose. On the other hand, a dose dependency in CLtot for unbound GLZ was observed and confirmed to be attributed to dose dependency in CLB for unbound GLZ since there was no significant difference in CLR or metabolic clearance for unbound GLZ between the doses.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

3.
Midazolam concentrations in patients' plasma was determined after extraction with high performance liquid chromatography (HPLC), gas chromatography (GC) and gas chromatography/mass spectrometry (GC/MS). GC was selected for routine plasma assays in terms of selectivity, simplicity, precision, accuracy and sensitivity (0.02 microgram/mL); HPLC analysis was less sensitive (0.1 microgram/mL) than GC; GC/MS was used for analysis validation. Plasma protein binding of midazolam was determined by GC in patients' plasma after in vitro incubation with midazolam, ultrafiltration and extraction; 5% of the drug was unbound to plasma proteins. Midazolam distribution in lipoprotein fractions separated by ultracentrifugation of plasma obtained from patients on prolonged midazolam treatment was also assayed by GC.  相似文献   

4.
A sensitive enantioselective liquid chromatographic assay with mass spectrometric detection (LC-MS) has been validated for the determination of total and free plasma concentrations of (R)- and (S)-methadone (Met) and (R)- and (S)-2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP, the primary metabolite of Met), using their respective deuterium-labeled compounds as internal standards [(R,S)-d3-Met and (R,S)-d3-EDDP]. For total drug determinations, 1 ml human plasma was extracted, using a cation-exchange solid-phase extraction cartridge; the eluate was evaporated, reconstituted in the mobile phase, and injected into the LC-MS system. The free fractions of Met and EDDP were determined, using 500 microl of plasma, which were placed in an ultrafiltration device and centrifuged at 2000 x g until 250 microl of filtrate was collected. The filtrate was extracted as described above and analyzed. Enantioselective separations were achieved using an alpha1-acid glycoprotein chiral stationary phase, a mobile phase composed of acetonitrile-ammonium acetate buffer [10 mM, pH 7.0] (18:82, v/v), a flow rate of 0.9 ml/min at 25 degrees C. Under these conditions, enantioselective separations were observed for Met (alpha = 1.30) and EDDP (alpha = 1.17) within 15 min. Met, EDDP, [2H3]-Met and [2H3]-EDDP were detected using selected ion monitoring at m/z 310.30, 278.20, 313.30, and 281.20, respectively. Linear relationships between peak height ratio and drug-enantiomer concentrations were obtained for Met in the range 1.0-300.0 ng/ml, and for EDDP from 0.1 to 25.0 ng/ml with correlation coefficients greater than 0.999, where the lower limit of quantification (LLOQ) was 1 ng/ml for Met and 0.1 ng/ml for EDDP. The relative standard deviation (R.S.D.) expressed as R.S.D. for the intra- and inter-day precision of the method were < 5.3% and the R.S.D. for accuracy was < 5.0%. The method was used to analyze plasma samples obtained from patients enrolled in a Met-maintenance program.  相似文献   

5.
A theoretical study on the protonation system of [N,C,C,S], [H,N,C,C,S]+, was performed at the B3LYP/6-311++G(d,p) and CCSD(T)/6-311++G(2df,2p) (single point) levels of theory. On the doublet [H,N,C,C,S]+ surface, 24 species were located as energy minima and 10 of them were considered as kinetically stable species. The species HNCCS+ with 2A' state and a shallow W-shaped skeleton was predicted to be the global minimum and kinetically the most stable species, being in good agreement with previous experimental findings. Furthermore, the protonation reactions of the stable [N,C,C,S] isomers were investigated in detail. The calculation results indicated that the [N,C,C,S] isomers may be significantly stabilized upon protonation. Finally, the possible covalent structures of the [H,N,C,C,S]+ isomers with considerable stability were briefly discussed.  相似文献   

6.
A rapid, sensitive, and specific high performance liquid chromatographic (HPLC) assay was developed for the determination of 2-methoxy-11-oxo-11H-pyrido-[2,1-b]quinazoline-8-carboxylic acid (I) from biological fluids. The overall recovery from blood and plasma is 69 +/- 10% (S.D.) and 84 +/- 6% (S.D.), respectively, and the sensitivity limit of quantitation is 100 ng/ml by UV absorption and 5 ng/ml by fluorescence detection using a 1 ml specimen. The assay was used in the determination of blood levels of compound in the Rhesus monkey following intravenous administration of a 10 mg/kg dose, and of blood and urine levels of compound I in a dog following intravenous and oral administration of a 1 mg/kg dose.  相似文献   

7.
Aberrant protein glycosylation may be closely associated with cancer pathology. To measure the abundance of protein glycoforms with a specific glycan structure in plasma samples, we developed a lectin-coupled multiple reaction monitoring (MRM)-based mass spectrometric method. It was confirmed that the method could provide reproducible results with precision sufficient to distinguish differences in the abundance of protein glycoforms between individuals. Plasma samples prepared from hepatocellular carcinoma (HCC) patients without immuno-depletion of highly abundant plasma proteins were fractionated by use of fucose-specific aleuria aurantia lectin (AAL) immobilized on magnetic beads by use of a biotin–streptavidin conjugate. The lectin-captured fractions were digested by trypsin and profiled by tandem mass spectrometry. From the proteomic profiling data, target glycoproteins were selected and analyzed quantitatively by MRM-based analysis. The reproducibility of MRM-based quantification of the selected target proteins was reliable, with precision (CV; ≤14% for batch-to-batch replicates and ≤19% for replicates over three days) sufficient to distinguish differences in the abundance of AAL-captured glycoforms between individual plasma samples. This lectin-coupled, MRM-based method, measuring only lectin-captured glycoforms of a target protein rather than total target protein, is a tool for monitoring differences between individuals by measuring the abundance of aberrant glycoforms of a target protein related to a disease. This method may be further applied to rapid verification of biomarker candidates involved in aberrant protein glycosylation in human plasma.  相似文献   

8.
Nickel(II) complexes of the monoanionic borato ligands [Ph2B(CH2SCH3)2] (abbreviated Ph2Bt), [Ph2B(CH2S(t)Bu)2] (Ph2Bt(tBu)), [Ph2B(1-pyrazolyl)(CH2SCH3)], and [Ph2B(1-pyrazolyl)(CH2S(t)Bu)] have been prepared and characterized. While [Ph2Bt] formed the square planar homoleptic complex, [Ph2Bt]2Ni, the larger [S2] ligand with tert-butyl substituents, [Ph2BttBu], yielded an unexpected organometallic derivative, [Ph2Bt(tBu)]Ni(eta2-CH2SBut), resulting from B-C bond rupture. The analogous thiametallacycle derived from the [S3] ligand, [PhB(CH2S(t)Bu)3] (PhTt(tBu)), has been structurally authenticated (Schebler, P. J.; Mandimutsira, B. S.; Riordan, C. G.; Liable-Sands, L.; Incarvito, C. D.; Rheingold, A. L. J. Am. Chem. Soc. 2001, 123, 331). The [SN] borato ligands formed exclusively the cis stereoisomers upon reaction with Ni(II) sources, [Ph2B(1-pyrazolyl)(CH2SR)]2Ni. Analysis of the Ni(II/I) reduction potentials by cyclic voltammetry revealed a approximately 600 mV anodic shift upon replacement of two thioether donors ([Ph2Bt]2Ni) with two pyrazolyl donors ([Ph2B(1-pyrazolyl)(CH2SCH3)]2Ni) consistent with the all thioether environment stabilizing the lower oxidation state of nickel.  相似文献   

9.
Two methods are presented for the determination of 'respectively' the plasma protein unbound and total concentration of acyclovir in horse plasma and body fluids: first, a liquid-liquid extraction was performed on plasma, combined with HPLC-fluorescence detection for the total plasma concentration; second a more sensitive method using high-performance liquid chromatography combined with heated electrospray ionization tandem mass spectrometry (LC-HESI-MS/MS) was described for plasma and for body fluids analysis. To obtain the unbound concentration of acyclovir in plasma, a simple deproteinization step using a Microcon filter was performed. Ganciclovir was used as an internal standard. Analysis was carried out on an Inertsil 5 ODS-3 column for the HPLC-fluorescence method. For the LC-HESI-MS/MS method a PLRP-S column was used. The limit of quantification (LOQ) for the total concentration was set at 50 and 2 ng mL(-1) for the HPLC-fluorescence method and the LC-HESI-MS/MS method, respectively. The limit of quantification for the unbound concentration was set at 5 ng mL(-1) and at 2 ng mL(-1) for body fluids. The methods were successfully used to perform pharmacokinetic and clinical studies in horses after intravenous and oral dosage of acyclovir and its prodrug valacyclovir.  相似文献   

10.
A high‐performance liquid chromatography–tandem mass spectrometry method was developed and validated for the simultaneous quantification of morphine, morphine's major metabolites morphine‐3‐glucuronide and morphine‐6‐glucuronide, and clonidine, to support the pharmacokinetic analysis of an ongoing double‐blinded randomized clinical trial that compares the use of morphine and clonidine in infants diagnosed with neonatal abstinence syndrome. Plasma samples were processed by solid‐phase extraction and separated on an Inertsil ODS‐3 (4 μm) column using an 0.1% formic acid in water–0.1% formic acid in methanol gradient. Detection of the analytes was conducted in the positive multiple reaction monitoring mode. The range of quantitation was 1–1000 ng/mL for morphine, morphine‐3‐glucuronide and morphine‐6‐glucuronide, and 0.25–100 ng/mL for clonidine. Intra‐day and inter‐day accuracy and precision were ≤15% for all analytes across the quantitation range. Extraction recovery rates were ≥94% for morphine, ≥90% for M3G, ≥87% for M6G and ≥ 79% for clonidine. Matrix effect ranged from 85–94% for clonidine to 101–106% for M3G. The method fulfilled all predetermined acceptance criteria and required only 100 μL of starting plasma volume. Furthermore, it was successfully applied to 30 clinical trial plasma samples.  相似文献   

11.
A procedure developed for separating and quantifying non protein and protein fractions of aluminum species in urine was applied to four consecutive 24 hr collections of five healthy subjects. The total Al content of urine was determined by a chemical neutron activation analysis technique reported elsewhere. Results from the analysis of all subjects indicate that the majority of aluminum is bound to protein (>88%) with minor fractions as citrate complexes. These data are comparable with other speciation experiments with blood plasma indicating 90% of the aluminum was bound to plasma proteins.  相似文献   

12.
在自制的仪器上,进行了铌与硫的激光等离子体反应并记录了通过反应生成的正负离子的质谱。在反应生成的Nb_nS_m~+(n=1—6)中凡满足n<4,m=n+1;4≤n≤5,m=n+2;n=6,m=n+4的正离子均显示出相当突出的信号强度,其中的簇离子可能具有同[Mo_3S_4]~(4+)中的Mo_3S_3簇环相类似的类芳香性。在负离子质谱中也能观察到类似系列的Nb_nS_m~-,只是它们中的硫原子数均比相应的正离子多了4个,因而基本上实现了配位饱和。  相似文献   

13.
Sterically crowded peri-substituted selenium and tellurium acenaphthene donors D1-D7 [Acenap(EPh)(Br) E = Se, Te; Acenap(SePh)(EPh) E = Se, S; Acenap(TePh)(EPh) E = S, Se, Te] react with dibromine and diiodine acceptors to afford a group of structurally diverse addition products 1-12, comparable in some cases to previously reported naphthalene analogues. Tellurium donors D4-D6 react conventionally with the dihalogens to afford insertion adducts 6-11 (X-R(2)Te-X) exhibiting molecular see-saw geometries, characterised by hypervalent X-Te-X quasi-linear fragments. The reactions of selenium donors D1-D3 with diiodine afford expected neutral charge-transfer (CT) spoke adducts 1, 4 and 5 (R(2)Se-I-I) containing quasi-linear Se-I-I alignments. Conversely, treatment of D2 and D3 with dibromine results in the formation of two tribromide salts 2 and 3 containing bromoselanyl cations [R(2)Se-Br](+)···[Br-Br(2)](-), each exhibiting a quasi-linear three-body Br-Se···E (E = Se, S) fragment. The peri-bonding in these species can be thought of as a weak hypervalent G···Se-X three-centre, four-electron (3c-4e) type interaction, closely related to the T-shaped 3c-4e interaction. Density-functional calculations performed on 2 and 3 and their bare cations (2a and 3a) reveal Wiberg bond indices of 0.25-0.37, suggesting substantial 3c-4e character in these systems. The presence of such an interaction operating in 2 and 3 alleviates steric strain within the peri-region and minimises the degree of molecular distortion required to achieve a relaxed geometry. Ditellurium donor D7 reacts with dibromine to afford an unorthodox insertion adduct 12 containing a Te-O-Te bridge and two quasi-linear Br-Te-O fragments, with the central tellurium atoms assuming a molecular see-saw geometry. Whilst DFT calculations indicate 12 is thermodynamically unfavourable, its formation is viable under experimental conditions.  相似文献   

14.
Several high-performance liquid chromatography (HPLC) methods have been described for the determination of caffeine in human plasma. However, none have been cross validated using synthetic plasma. The present study describes a simple and reliable HPLC method for the determination of the caffeine level in human plasma. Synthetic plasma was used to construct calibration curves and quality control samples to avoid interference by caffeine commonly present in donor's human plasma. After deproteination of plasma samples with perchloric acid, caffeine and antipyrine (internal standard, IS) were separated on a Waters Atlantis C18 column using a mobile phase of 15 mM potassium phosphate (pH 3.5) and acetonitrile (83:17, v/v), and monitored by photodiode array detector, with the wavelength set at 274 nm. The relationship between caffeine concentrations and peak area ratio (caffeine-IS) was linear over the range of 0.05-20 μg/mL. Inter-run coefficient of variation was ≤ 5.4% and ≤ 6.0% and bias was ≤ 3% and ≤ 7% using human and synthetic plasma, respectively. Mean extraction recovery from human plasma of caffeine and the IS was 91% and 86%, respectively. Caffeine in human plasma was stable for at least 24 h at room temperature or 12 weeks at -20 °C, and after three freeze-thaw cycles. The method was successfully applied to monitor caffeine levels in healthy volunteers with correction of caffeine levels using the mean ratio of the slopes of the calibration's curves constructed using human and synthetic plasma.  相似文献   

15.
Fibroblasts of the line 3T3 from swiss albino mice were exposed to ultraviolet A (UVA) irradiation. The cells were synchronized by treatment with nocodazole and mitotic shake-off, and then exposed to UVA irradiation in different stages of the cell cycle. Their photosensitivity varied through the cell cycle, being greatest in the G2 phase. UVA irradiation was found to induce the formation of multinucleated cells. Cells in the G1 phase were found to be most prone to multinucleation 15 min after UVA irradiation, while cells exposed to UVA irradiation in S and G2 phases contained the largest fractions of multinucleated cells 24 h after treatment. The present results indicate that multinucleated cells are formed by fusion of two or more cells shortly after UVA irradiation of early G1 cells, while impairment of cytokinesis is a possible explanation for the delayed formation of multinucleated cells after irradiation in S and G2.  相似文献   

16.
A new approach for screening plasma protein binding is presented. The method is based on equilibrium dialysis combined with rapid generic LC-MS bioanalysis by using a sample pooling approach enabling high-throughput screening of protein binding in the drug discovery phase. The method is evaluated by a comparison of measured unbound free fractions f(u) (%) between single and pooled compounds for a test set of structurally diverse compounds with a wide range of unbound fractions. Test compounds include 1 acidic and 10 basic drug standards along with 36 new chemical entities. A good correlation (R2>0.95) of f(u) (%) between the single and pooled compounds is found, suggesting that at least 10 compounds can be simultaneously measured with acceptable accuracy. A simplified drug-protein binding model is applied to calculate the f(u) (%) of drugs at various drug and protein concentrations and this is applied to elucidate the applicability of the sample pooling approach from a theoretical standpoint. Moreover, pH shifts in the plasma were observed after dialysis when using different types of buffers and the impact of that on the f(u) is illustrated in association with their physicochemical properties, in particular the ionization state of compounds by the profile of effective mobility as a function of pH. A new buffer is proposed being able to minimize the pH shift of plasma during the dialysis. In addition, the application of the proposed buffer does not necessarily require adjusting plasma pH before the dialysis and utilizing a CO2 incubator during the dialysis. The effect of the ionic strengths of different buffers on MS signals is investigated with regard to ion suppression. The sample pooling method not only significantly reduces the plasma volume required but also the number of bioanalysis samples as compared to the single compound measurements by a conventional approach. The new proposed approach is especially beneficial for measuring in vitro protein binding in matrices such as mouse plasma where plasma is available only in limited amounts. The current new development will facilitate the drug discovery process by more rapidly assessing the protein binding potential of drug candidates.  相似文献   

17.
The effect of protein binding on the disposition of cephalexin (CEX) and cofazolin (CEZ) was investigated in a simultaneous perfusion system of rat liver and kidney. In the present study, we used bovine serum albumin (BSA) or human serum albumin (HSA) as plasma protein to control the degree of perfusate protein binding of drugs. Total clearance (CLt) of CEX perfused with BSA (0.70 +/- 0.27 ml/min) was slightly smaller than that with HSA (0.89 +/- 0.08 ml/min), corresponding to the unbound fraction of the drug in the perfusate plasma. On the other hand, CLt of CEZ perfused with BSA (0.90 +/- 0.20 ml/min) was significantly larger than that with HSA (0.32 +/- 0.10 ml/min). The unbound fraction of CEZ to BSA (0.703 +/- 0.052) was much larger than that to HSA (0.253 +/- 0.017) and the clearance of the unbound drug did not differ significantly between two kinds of albumin perfusate (1.30 +/- 0.40 ml/min for BSA and 1.26 +/- 0.40 ml/min for HSA). These results suggest that plasma protein binding is an important factor determining the biliary clearance as well as the urinary clearance of drugs.  相似文献   

18.
An analytical method using inductively coupled plasma atomic emission spectrometry (ICP-AES) for rapid simultaneous determination of seven heavy metals (Cd, Co, Cr, Cu, Mn, Ni and Pb) in human blood fractions, like plasma, cells fraction and whole blood, is performed. The optimum wavelength was selected using as criterions the sensitivity, the linearity and recovery of aqueous standard solutions. The pretreatment of the sample, the centrifugal conditions, the necessity of digestion and the dilution of the digests were also studied. For plasma it was possible to avoid digestion of the sample, but for cells fractions and whole blood the digestion is necessary. The samples were acid-digested by HNO3 in closed Teflon tubes under high temperature and pressure conditions and were diluted before injection into ICP-AES. Also, optimization of the inductively coupled plasma conditions like nebulizer argon flow rate, sample flow rate and power of radio frequency was performed for each analyte. Finally, the effect of the type of the employed calibration technique on the total variation of the method was examined. Calibration using the standard addition technique was proved more accurate for the determination in terms of analyte recovery. The sensitivity and recovery (Cd 99%, Co 101%, Cr 100%, Cu 99%, Mn 101%, Ni 100% and Pb 97%) of the developed method are presented for all examined blood fractions. Correspondence: George A. Zachariadis, Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124, Greece  相似文献   

19.
采用两步固相萃取(SPE)法结合无胶筛分毛细管电泳(NGCE)技术建立了猕猴血浆中的反义寡核苷酸药物癌泰得的定量分析方法。优化并确定了SPE的相关条件(阴离子交换柱,上样缓冲液pH值为9.0,上样体积及洗脱体积分别为5 mL和3 mL)和NGCE的分析条件(灌胶时间为30 min,分离电压为24 kV)。在优化的条件下,猕猴血浆中癌泰得在1.95~250 mg/L范围内呈良好的线性关系,定量限(LOQ)为1.95 mg/L。批内准确度为93.38%~100.71%,批内相对标准偏差<11%;批间准确度为89.46%~103.46%,批间相对标准偏差<9%。在不同条件(室温下存放4 h; 4 ℃下存放24 h;反复冻融(-80 ℃至室温)2次;-80 ℃下保存1个月)下癌泰得在猕猴血浆中的稳定性良好。已将该方法成功地应用于癌泰得的猕猴药代动力学研究。  相似文献   

20.
Propolis has various biological activities such as antibacterial, antiviral, antioxidant, immunostimulating and antiinflammatory, which are generally ascribed to the polyphenolic fraction. The aim of this study was to evaluate the absorption of the main polyphenols [caffeic acid (CA), pinobanksin-5methyl ether (P-5ME), pinobanksin (Pb), chrysin (C), pinocembrin (P), galangin (G), pinobanksin-3-acetate, pinobanksin esters and caffeic acid phenylethyl ester (CAPE)] from a dewaxed and standardized extract of propolis (EPID). Fifteen healthy volunteers consumed 5 mL EPID in water, corresponding to 125 mg of flavonoids. Blood samples were collected before, each hour for 8 h and 24 h after EPID intake. After deconjugation by beta-glucuronidase/sulfatase the plasma samples were analyzed by a selective liquid chromatography/tandem mass spectrometry (LC/MS/MS) method using morin as internal standard (I.S.). A kinetic profile characterized by two t(max), respectively at 1 h and about 5 h post-ingestion, was observed in all the subjects. The two peaks may be due to enterohepatic cycling. Among the various polyphenols ingested, only P-5ME, Pb, C, P and G were detected in plasma and C(max)t(1h) were 65.7 +/- 13.3, 46.5 +/- 12.7, 79.5 +/- 18.6, 168.1 +/- 16.3 and 113.7 +/- 16.8 ng/mL, respectively. These levels decreased significantly after 8 h and were no longer detectable 24 h after EPID intake. The recovery of the extraction for CA, Pb, C, P, G and I.S. from spiked plasma was 95.2 +/- 3.1, 93.1 +/- 3.6, 91 +/- 2.5, 96.4 +/- 4.2, 93.4 +/- 2.4 and 85.5 +/- 2.4%, respectively. The results of this study evidence that flavonoids from EPID are absorbed, metabolized and Pb-5ME and G seem to have apparent absorption, measured as (AUC/dose), higher than C, P and Pb.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号