首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A new, rapid, and efficient microextraction technique named vortex‐assisted natural deep eutectic solvent microextraction has been developed for the preconcentration and determination of orthophosphate in real water samples. The method is based on the formation of the phosphomolybdenium blue complex followed by proposed microextraction procedure and subsequent spectrophotometric determination in a microcell. Screening study for the optimal composition of natural deep eutectic solvent was initially performed with different solvents, including choline chloride as hydrogen bond acceptor and different hydrogen bond donors. A ternary mixture of glucose‐choline chloride‐water was used as the most efficient extraction solvent. Response surface methodology based on the central composite design was used to optimize experimental parameters. Under optimal conditions, the calibration graph for orthophosphate determination was linear over the range of 2.0–80.0 µg/L (correlation coefficient of 0.9971) with a detection limit of 0.2 µg/L. The repeatability, reproducibility, and relative error values of the method were below 7%, indicating acceptable precision and accuracy. This approach, using natural deep eutectic solvent as an eco‐friendly solvent with high solubilization power and vortex mixing as an alternative energy source, represents a promising choice for a green separation and preconcentration methodology for determination of orthophosphate in real water samples.  相似文献   

2.
A new effervescence-assisted dispersive liquid-liquid microextraction, EA-DLLME, technique was developed for preconcentration and flame atomic absorption spectrometric determination of copper in aqueous samples. Effervescence assistance and DES combination for metal ion extraction was used for the first time. In the presented study, six different effervescence powders were examined to achieve maximum extraction efficiency. In addition, 1,5 diphenyl carbazide was used as complexing agent and DES prepared by mixing choline chloride and phenol was used as extraction solvent. The effect of several parameters such as pH, concentration of complexing agent, composition and volume of DES, amount of THF, composition and amount of effervescent agent were examined. Performed experiments showed that optimum pH was 6.0, the best effervesce powder composition was NaH2PO4:Na2CO3 with 2 × 10?3:1 × 10?3 molar ratio and the amount of effervesce powder was 0.4 g. Under optimum conditions enhancement factor, limit of detection and limit of quantification were calculated as 78, 2.9 and 9.7 μg L?1, respectively. In addition, to prove precision of the method intra-day relative standard deviations were calculated for 10 and 50 μg L?1 Cu2+ concentrations and found as 2.1% and 1.3%, respectively. The proposed method showed good linearity within the range of 10.0–100 μg L?1. Finally, proposed method was successfully applied to determination of copper traces in aqueous samples.  相似文献   

3.
建立了一种基于低共熔溶剂(DESs)的液液微萃取-高效液相色谱联用(LLME-HPLC)技术用于测定食用油中的双酚A(BPA)的方法,对比了3种DES和甲醇、乙二醇对食用油中BPA的萃取效率,研究了温度、萃取时间和萃取剂体积对萃取效率的影响。结果表明:氯化胆碱/乙二醇组成的DES萃取率最高;低共熔溶剂用量100μL,萃取温度25℃,萃取时间5 min时,萃取效率最高。BPA的检测限和定量限分别为0.10 mg/L和0.50 mg/L,加标回收率在86.3%~109.9%范围内,RSD小于6%。方法可用于食用油中BPA的检测。  相似文献   

4.
Ternary deep eutectic solvent magnetic molecularly imprinted polymers grafted on silica were developed for the selective recognition and separation of theophylline, theobromine, (+)‐catechin hydrate, and caffeic acid from green tea through dispersive magnetic solid‐phase microextraction. A new ternary deep eutectic solvent was adopted as a functional monomer. The materials obtained were characterized by FTIR spectroscopy, field emission scanning electron microscopy, transmission electron microscopy, NMR spectroscopy, and powder X‐ray diffraction. The practical recovery of the theophylline, theobromine, (+)‐catechin hydrate, and caffeic acid isolated with ternary deep eutectic solvent magnetic molecularly imprinted polymers in green tea were 91.82, 92.13, 89.96, and 90.73%, respectively, and the actual amounts extracted were 5.82, 4.32, 18.36, and 3.69 mg/g, respectively. The new method involving the novel material coupled with dispersive magnetic solid‐phase microextraction showed outstanding recognition, selectivity and excellent magnetism, providing a new perspective for the separation of bioactive compounds.  相似文献   

5.
ABSTRACT

The parabens, which are harmful to our bodies, are primarily utilized as preservatives in medicine, personal care products and cosmetics. A novel, more efficient, fast and cheap vortex-assisted liquid phase microextraction method based on deep eutectic solvents (DESs) was developed for the determination of parabens. The microextraction conditions were optimized using these solvents and the analytical parameters of the method were determined under optimal microextraction conditions. After extraction, the chromatographic separation of parabens was undertaken using high-performance liquid chromatography-UV detection. Experimental parameters, such as DES type, DES volume, dilution solvent volume and vortex extraction time were optimized. DES6 [ChCl-Ethylene glycol (1/2)] was the most suitable DES to work in this study. Detection limits for this method of 0.053 µg mL?1 for methylparaben, 0.061 µg mL?1 for ethylparaben, 0.049 µg mL?1 for propylparaben and 0.052 µg mL?1 for butylparaben were obtained. Correlation coefficients (R2) for a concentration range of 0.1–100 µg mL?1 were higher than 0.9992 and relative standard deviation (RSD) values below 2.91% at parabens concentration of 2.5 µg mL?1 were obtained. The results of spike/recovery values of real samples were greater than 84%. When compared with other methods, the main advantages include lower LOD, short extraction time, rapidity, repeatability and simplicity.  相似文献   

6.
A green and sensitive thin-film solid-phase microextraction method based on deep eutectic solvent was developed that enables simultaneous isolation, preconcentration, and determination of parabens in surface waters. Six new deep eutectic solvents were synthesized and used directly to prepare thin-film coatings on a stainless steel mesh support. Among the compounds obtained, the highest efficiency in the extraction of parabens was found for a material consisting of trihexyltetradecylphosphonium chloride and n-docosanol in a molar ratio of 1:2. For the proposed method, parameters affecting the extraction efficiency of parabens, such as the coating material, the desorption solvent, the volume of the sample, the pH of the sample, the extraction and desorption time, and the salting-out effect, were optimized. Under optimal conditions, the proposed method allowed us to achieve good precision between 3.6 and 6.5% and recovery ranging from 68.1 to 91.4%. The limits of detection range from 0.018 to 0.055 ng/mL.  相似文献   

7.
陈娜  张毅军  赵万里  陈军  张裕平 《色谱》2018,36(1):5-11
采用氯化胆碱-乙二醇低共熔溶剂(DES)作致孔剂,制备了聚(甲基丙烯酸丁酯-乙二醇二甲基丙烯酸酯)[poly(BMA-EDMA)]固相微萃取头,并与超高效液相色谱法(UPLC)结合测定了湖水中的3种多环芳烃(PAHs)。实验与不使用DES致孔剂的固相微萃取头和商品化聚二甲硅氧烷(PDMS)萃取头进行比较,含DES的poly(BMA-EDMA)固相微萃取头的富集效果最好。系统考察了萃取条件(萃取时间、萃取溶剂、解吸时间、解吸溶剂及离子强度)对水样中多环芳烃萃取效率的影响。在最优的实验条件下,3种多环芳烃类化合物(萘、联苯、菲)的线性范围为0.1~6.0 mg/L(r≥0.990 3),检出限为2.1~4.9μg/L,回收率为86.4%~111.3%,相对标准偏差(RSD,n=6)为11.2%~15.1%。该法操作简便,稳定性好,成本低,适用于实际环境水样中多环芳烃类化合物的测定。  相似文献   

8.
A novel type of solvent named deep eutectic solvent (DES) has been considered as a green ionic liquid analogue. A novel method was developed for enrichment and speciation of chromium ion from water and food samples based on deep eutectic solvent and ultrasonic extraction. The procedure for this method was comprised of Cr(III) complex formation with a hydrophobic complexing agent (Z)‐N‐(3,5‐diphenyl‐1H‐pyrrol‐2‐yl)‐3,5‐diphenyl‐2H‐pyrrol‐2‐imine (azadipyrromethene dye). Metal complex was entrapped in a deep eutectic solvent as an extracting solvent. While Cr(III) recovery was quantitative, the recovery of Cr(VI) was found 5%. After reduction of Cr(VI) to Cr(III), the method was applied for determination of total chromium(III) ion. The amount of Cr(VI) was calculated as subtracting of Cr(III) from total chromium ion. Various analytical parameters were optimized. The certified reference materials were analyzed and standard addition method also carried out to real samples to check the accuracy of the developed method. Preconcentration factor was found to be 50. The limit of detection of chromium(III) was found to be 4.3 ng l‐1. The precision of developed method as the relative standard deviation (RSD) was found as 3.5 %. The developed method was applied successfully for the speciation of chromium ions in water and food samples.  相似文献   

9.
2,4,6-三芳基吡啶是一类重要的杂环化合物,在多个领域有广泛的应用.本文在氯化胆碱/对甲苯磺酸组成的低共熔溶剂中,以芳香酮、芳香醛、乙酸铵为原料,微波辐射下一锅合成了一系列2,4,6-三芳基吡啶,产率74.6~90.7%,产物结构经1 H NMR、13 C NMR表征.该法具有反应条件温和、操作简单、产率较高、耗时短...  相似文献   

10.
An ultrasound-assisted emulsification microextraction (USAEME) based on low-density solvents was successfully applied for the extraction and pre-concentration of four toxic nitrophenols in water samples. The extracted analytes were analyzed by high-performance liquid chromatography-UV detection. The important parameters influencing the extraction efficiency were studied and optimized utilizing two different optimization methods: one variable at a time (OVAT) and central composite design (CCD). The results showed that the emulsification process can be completed in a few seconds using low-density solvents, but almost 10–20?min is necessary for high-density solvents. Under the optimum conditions (extraction solvent, 1-octanol; extraction solvent volume, 40?µL; sample pH, 3.0; salt concentration, 20% (w/v) NaCl; extraction temperature, 40 (±3)°C), limits of detection of the method were in the range of 0.25 to 1?µg?L?1 and the repeatability and reproducibility of the proposed method, expressed as relative deviation, varied in the range of 2.2–4.2% and 4.7–6.9%, respectively. Linearity was found to be in the range of 1 to 200?µg?L?1 and the preconcentration factors (PFs) were between 77 and 175. The relative recoveries of the four nitrophenols from water samples at spiking level of 10.0?µg?L?1 were in the range of 92.0 to 115.0%.  相似文献   

11.
Abstract

A metal-free and base-free strategy was developed in DES to synthesize styrenes for the first time by decarboxylation of cinnamic acid derivatives, which provided a renewable and cost efficiently protocol to access various styrenes including those with functional groups such as 4-vinylphenol and 1-chloro-4-vinylbenzene.  相似文献   

12.
We present a novel dispersive liquid–liquid microextraction method based on the solidification of deep eutectic solvent coupled with high‐performance liquid chromatography with a variable‐wavelength detection for the detection of five benzoylureas in real water samples. In this work, a green solvent consisting of 1‐octyl‐3‐methylimidazolium chloride and 1‐dodecanol was used as an extraction solvent, yielding the advantages of material stability, low density, and a suitable freezing point near room temperature. Parameters that significantly affect extraction efficiency were optimized by the one‐factor‐at‐a‐time approach. Under optimal conditions, the recoveries of five target compounds were obtained ranging from 87.39 to 98.05% with correlation coefficients ranging from 0.9994 to 0.9997 for pure water. The limits of detection were in the range of 0.09–0.16 μg/L. The enrichment factors were in the range of 171–188. Linearities were achieved in the range of 0.5–500 μg/L. The proposed method was successfully applied to determine benzoylureas in environmental water samples with a satisfactory recovery of approximately 81.38–97.67%.  相似文献   

13.
The separation of 11 phthalic acid ester (PAEs) was carried out by nano-liquid chromatography coupled to ultraviolet and MS detection. Preliminary experiments were achieved in order to select suitable stationary phases and chromatographic conditions. The baseline separation was obtained, for all compounds, with an XBridgeTM C18 column in less than 15 min, working in step gradient mode. The sensitivity of the method was improved by on-column focusing. PAEs were extracted from alcoholic and nonalcoholic beverages using vortex-assisted emulsification dispersive liquid–liquid microextration and natural deep eutectic solvents. The whole method was validated in terms of linearity, sensitivity, precision, recovery, and repeatability. Combination of both off-line sample preparation preconcentration and large injection volume led to obtain LOQs in the range 5–47 ng/mL. The developed nano-LC-UV method was extended to MS detection to confirm the presence of PAEs in some beverages commercialized in different types of packaging.  相似文献   

14.
A facile headspace single drop microextraction method was developed using deep eutectic solvent‐based magnetic bucky gel as the extraction solvent for the first time. The hydrophobic magnetic bucky gel was formed by combining choline chloride/chlorophenol deep eutectic solvent and magnetic multiwalled carbon nanotube nanocomposite. Magnetic susceptibility, high viscosity, high sorbing ability, and tunable extractability of organic analytes are the desirable advantages of the prepared gel. Using a rod magnet as a suspensor in combination with the magnetic susceptibility of the prepared gel resulted in a highly stable droplet. This stable droplet eliminated the possibility of drop dislodgement. The prepared droplet made it possible to complete the extraction process in high temperatures and elevated agitation rates. Furthermore, using larger micro‐droplet volumes without any operational problems became possible. These facts resulted in shorter sample preparation time, higher sensitivity of the method, and lower detection limits. Under the optimized conditions, an enrichment factor of 520–587, limit of detection of 0.05–0.90 ng/mL, and linearity range of 0.2–2000 ng/mL (coefficient of determination = 0.9982–0.9995) were obtained. Relative standard deviations were < 10%. This method was successfully coupled with gas chromatography and used for the determination of benzene, toluene, ethylbenzene, and xylene isomers as harmful volatile organic compounds in water and urine samples.  相似文献   

15.
Four kinds of green deep eutectic solvents (DESs) based on choline chloride (ChCl) have been synthesized and coated on the surface of magnetic graphene oxide (Fe3O4@GO) to form Fe3O4@GO-DES for the magnetic solid-phase extraction of protein. X-ray diffraction (XRD), vibrating sample magnetometer (VSM), Fourier transform infrared spectrometry (FTIR), field emission scanning electron microscopy (FESEM) and thermal gravimetric analysis (TGA) were employed to characterize Fe3O4@GO-DES, and the results indicated the successful preparation of Fe3O4@GO-DES. The UV–vis spectrophotometer was used to measure the concentration of protein after extraction. Single factor experiments proved that the extraction amount was influenced by the types of DESs, solution temperature, solution ionic strength, extraction time, protein concentration and the amount of Fe3O4@GO-DES. Comparison of Fe3O4@GO and Fe3O4@GO-DES was carried out by extracting bovine serum albumin, ovalbumin, bovine hemoglobin and lysozyme. The experimental results showed that the proposed Fe3O4@GO-DES performs better than Fe3O4@GO in the extraction of acidic protein. Desorption of protein was carried out by eluting the solid extractant with 0.005 mol L−1 Na2HPO4 contained 1 mol L−1 NaCl. The obtained elution efficiency was about 90.9%. Attributed to the convenient magnetic separation, the solid extractant could be easily recycled.  相似文献   

16.
Novel poly(deep eutectic solvent) grafted silica-coated magnetic microspheres (Fe3O4@SiO2-MPS@PDES) were prepared by polymerization of choline chloride-itaconic acid (ChCl-IA) and γ-MPS-modified magnetic silica composites, and were characterized by vibrating sample magnetometer (VSM), Fourier transform infrared spectrometry (FT-IR), X-ray photoelectron spectra (XPS), thermal gravimetric analysis (TGA) and transmission electron microscope (TEM). Then the synthetic Fe3O4@SiO2-MPS@PDES microspheres were applied for the magnetic solid-phase extraction (MSPE) of trypsin for the first time. After extraction, the concentration of trypsin in the supernatant was determined by a UV–vis spectrophotometer. Single factor experiments were carried out to investigate the effects of the extraction process, including the concentration of trypsin, the ionic strength, the pH value, the extraction time and the temperature. Experimental results showed the extraction capacity could reach up to 287.5 mg/g under optimized conditions. In comparison with Fe3O4@SiO2-MPS, Fe3O4@SiO2-MPS@PDES displayed higher extraction capacity and selectivity for trypsin. According to the regeneration studies, Fe3O4@SiO2-MPS@PDES microspheres can be recycled six times without significant loss of its extraction capacity, and retained a high extraction capacity of 233 mg/g after eight cycles. Besides, the activity studies also demonstrated that the activity of the extracted trypsin was well retained. Furthermore, the analysis of real sample revealed that the prepared magnetic microspheres can be used to purify trypsin in crude bovine pancreas extract. These results highlight the potential of the proposed Fe3O4@SiO2-MPS@PDES-MSPE method in separation of biomolecules.  相似文献   

17.
A free dispersive method, air-assisted in situ deep eutectic solvent decomposition followed by the solidification of floating organic droplets liquid-liquid microextraction was indicated in this study. This technique was utilized to simultaneously ascertain some azole antifungal drugs prior to high-performance liquid chromatography. In this research, a quasi-hydrophobic deep eutectic solvent was formed from tetrabutylammonium bromide and 1-dodecanol as an organic solvent at a 1:2 molar ratio. The synthesized deep decomposition in the sample solution caused in situ dispersion of extraction solvent and analytes. Air-assisted enhanced a dispersion condition in the sample solution. 1-Dodecanol as a green option was replaced with typical extraction solvents providing the advantages of a suitable freezing point near room temperature and low density. The effect of important analytical parameters on the extraction recovery of analytes was assessed. Under these optimal conditions, the limits of detection and the limits of quantitation determined were in the range of 0.5–2.8 and 1.5–9 μg/L, for water, urine and plasma samples, respectively. The intra-day and inter-day relative standard deviations (n = 5) were calculated to be 2.9–4.6 and 4.2–8.9%, respectively. The results represented the effectiveness of the developed method for the extraction and determination of analytes in biological samples.  相似文献   

18.
A green extractant, hydrophobic deep eutectic solvent was first introduced for extraction of tetracycline, oxytetracycline, and chlortetracycline from environmental water samples prior to high‐performance liquid chromatography determination. Deep eutectic solvents consist of methyltrioctylammonium chloride and various medium‐chain alcohols/acids, and are easy in preparation, low cost and toxicity, desirably biodegradable, and biocompatible. The overall time required for sample preparation was 6 min and the volume of organic solvent used for extraction was only 400 µL. Under the optimized extraction condition, the present method yielded low limit of detection (0.5–2.0 ng/mL), acceptable precision (relative standard deviations < 9.7%), good linearity from 2.0 to 500 ng/mL (r2 ≥ 0.9991). This optimized procedure was applied for determination of tetracyclines in different water samples with desirable spiked recovery ranged from 77.5 to 87.6%. There is, therefore, a great potential to further expand application of the method for investigation of other ultra‐trace analyte(s) in environmental matrixes.  相似文献   

19.
In this study, quartz sand with particularly sharp nanoscale edges acted like a nanoscale knife physically cut cells of Polygonatum cyrtonema Hua into nanosized particles and was synergized with natural deep eutectic solvent to extract steroidal saponins of Polygonatum cyrtonema Hua. The natural deep eutectic solvent (choline chloride-lactic acid)-synergistic quartz sand-assisted extraction was optimized using response surface methodology. The steroidal saponins purified with AB-8 macroporous resin were identified using ultra-high-performance liquid chromatography-triple time of flight mass spectrometry. The results showed that the experimental total saponins content value (36.97 ± 0.12 mg dioscin equivalent/g dry weight) at optimal extraction conditions with a temperature of 68°C, a rotational speed of 20 400 rpm, shear time of 4.3 min, the liquid-solid ratio of 38 ml/g, was close to the maximum possible theoretical value (36.64 mg dioscin equivalent/g dry weight). A total of 20 steroidal saponins were identified, among which the content of (25R)-Kingianoside E was the highest (102.66 ± 3.47 mg/g). Furthermore, a new steroid saponin (3β,25S)-26-(β-D-glucopyranosyloxy)-22-hydroxyfurost-5-en-3-yl 4-O-β-D-glucopyranosyl-β-D-galactopyranoside+Glc was found for the first time. These results revealed that natural deep eutectic solvent-synergistic quartz sand-assisted extraction was an efficient and green method to extract a variety of steroidal saponins.  相似文献   

20.
Based on the solidification of a hydrophobic deep eutectic solvent in air‐assisted liquid phase microextraction combined with gas chromatography and mass spectrometry, a green and sustainable microextraction technique was developed for extracting, separating, and detecting organophosphorus flame retardants in aqueous samples. In this study, some strategies were considered for overcoming or improving the challenges of conventional solvent microextraction procedures. In addition, a hydrophobic deep eutectic solvent with a freezing point near the ambient temperature was employed as an extraction phase, the dispersive solvent was substituted by the syringe pump process, and the centrifugation step was omitted by using salting‐out phenomenon. Further, the effect of the main independent variables was evaluated by using the chemometric methods in order to maximize the extraction efficiency of the procedure. Under optimal conditions, the calibration model was linear in the range of 0.01–25.0 µg/L. Limits of detection and quantitation were assessed at the concentration levels of 2–23 and 9–65 ng/L, respectively. The precision involving repeatability and reproducibility was evaluated by estimating the relative standard deviation, the levels of which were <6.6 and <8.7%, respectively. The applicability of the method was successfully evaluated by analyzing the target analytes in real aqueous samples, which illustrated satisfactory recoveries (95–104.61%).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号