共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Aleksandra Chojnacka Hans-Gerd Janssen Peter Schoenmakers 《Analytical and bioanalytical chemistry》2014,406(2):459-465
Measuring polymer solubility accurately and precisely is challenging. This is especially true at unfavourable solvent compositions, when only very small amounts of polymer dissolve. In this paper, pyrolysis–gas chromatography–mass spectrometry (Py-GC-MS) is demonstrated to be much more informative and sensitive than conventional methods, such as ultraviolet spectroscopy. By using a programmed-temperature-vapourisation injector as the pyrolysis chamber, we demonstrate that Py-GC-MS can cover up to five orders of magnitude in dissolved polymer concentrations. For polystyrene, a detection limit of 1 ng mL?1 is attained. Dissolution in poor solvents is demonstrated to be discriminating in terms of the analyte molecular weight. Py-GC-MS additionally can yield information on polymer composition (e.g. in case of copolymers). In combination with size-exclusion chromatography, Py-GC-MS allows us to estimate the molecular weight distributions of minute amounts of a dissolved polymer and variations therein as a function of time. Figure
SEC/-/Py-GC-MS (reconstructed, chromatograms) of dissolved polymer in ACN/THF%. 相似文献
3.
4.
The increasing use and production of nanomaterials have led to growing concern over the release of new pollutants to the environment. Fullerenes have been a subject of intense research, both because of their unique chemistry and because of technological applications. The development of analytical methods to quantify the fullerenes in complex sample matrices is a crucial step in the study of their occurrence and exposure, and thus in risk assessment. This paper reports the development and optimisation of a method combining liquid chromatography with ion-trap mass spectrometry (LC-ITMS) for analysis of the fullerene C(60). Under the optimised chromatogram conditions, a C(18) analytical column had good selectivity for fullerenes C(60) and C(70), with retention times of 3.0 and 4.1 min, respectively. Mass spectrometric detection was tested and optimised using three common ionisation techniques-atmospheric-pressure chemical ionisation (APCI), atmospheric-pressure photoionisation (APPI), and electrospray ionisation (ESI). The molecular ion was most abundant for C (60) (-) (m/z=720) in APCI and APPI, whereas adduct ions were formed with the molecular ion in ESI. Finally, the performance of the three ionisation techniques examined was compared by use of five validation criteria. The instrument detection limit (8 ng mL(-1)), quantification limit (27 ng mL(-1)), detection sensitivity (90.2 ng mL(-1)), linear range (8-1,000 ng mL(-1)), and repeatability (15 %) of APPI make it the most promising ionisation technique for fullerene C(60) analysis. 相似文献
5.
José Luis Pérez Pavón Miguel del Nogal Sánchez María Esther Fernández Laespada Bernardo Moreno Cordero 《Analytical and bioanalytical chemistry》2009,394(5):1463-1470
A sensitive method for the fast analysis of filbertone in spiked olive oil samples is presented. The applicability of a headspace
(HS) autosampler in combination with a gas chromatograph (GC) equipped with a programmable temperature vaporizer (PTV) and
a mass spectrometric (MS) detector is explored. A modular accelerated column heater (MACHTM) was used to control the temperature of the capillary gas chromatography column. This module can be heated and cooled very
rapidly, shortening total analysis cycle times to a considerable extent. The proposed method does not require any previous
analyte extraction, filtration and preconcentration step, as in most methods described to date. Sample preparation is reduced
to placing the olive oil sample in the vial. This reduces the analysis time and the experimental errors associated with this
step of the analytical process. By using headspace generation, the volatiles of the sample are analysed without interference
by the non-volatile matrix, and by using injection in solvent-vent mode at the PTV inlet, most of the compounds that are more
volatile than filbertone are purged and the matrix effect is minimised. Use of a liner packed with Tenax-TA? allowed the compound
of interest to be retained during the venting process. The limits of detection and quantification were as low as 0.27 and
0.83 μg/L, respectively, and precision (measured as the relative standard deviation) was 5.7%. The method was applied to the
determination of filbertone in spiked olive oil samples and the results revealed the good accuracy obtained with the method. 相似文献
6.
Dženeta Nezirević Dernroth Annica RundströmBertil Kågedal 《Journal of chromatography. A》2009,1216(30):5730-5739
Melanoma is most rapidly increasing in the white population and people with pheomelanin skin type are at high risk to develop melanoma. However, little is known about the pheomelanin structure and function, and further elucidation of this melanin is therefore an important task. A GC/MS method was developed based on hydriodic acid hydrolysis of pheomelanin in the urine. Derivatization was performed with ethyl chloroformate and ethanol:pyridine (4:1, v/v). N,O-Ethoxycarbonyl-ethyl esters were extracted with chloroform and analyzed by GC/MS. 4-Amino-3-hydroxyphenylalanine and 3-amino-4-hydroxyphenylalanine together with one benzothiazinone and two benzothiazole compounds were detected and identified in hydrolyzed samples of synthetic pheomelanin and melanin from the urine of a patient with melanoma. These findings strongly suggest that heterocyclic pheomelanin-type units are incorporated in the pigment structures. 相似文献
7.
Fuchslueger U Rissler K Grether HJ Grasserbauer M 《Analytical and bioanalytical chemistry》1996,356(8):495-499
High-performance liquid chromatography (HPLC) coupled to mass spectrometry (MS) is used to detect 2,4-dinitrophenyl (DNP) derivatives of amines by means of negative chemical ionisation at atmospheric pressure. The high sensitivity and good comparability of UV- and MS-detection of DNP-derivatives of amines is shown by several examples. The high selectivity of the derivatisation and the detection method (UV and MS) is used for the analysis of unknown amines in aqueous phases after hydrolytic degradation of polyamide-amine- or polyamine-epoxide-adducts as well as for the characterisation of commercial products. 相似文献
8.
Maziarz EP Liu XM Quinn ET Lai YC Ammon DM Grobe GL 《Journal of the American Society for Mass Spectrometry》2002,13(2):170-176
In this study the prepolymer alpha,omega-bis(4-hydroxybutyl) poly(dimethylsiloxane), used in the formulation of oxygen permeable films, is evaluated by gel permeation chromatography (GPC) combined with matrix assisted laser desorption ionization (MALDI) time of flight (TOF) mass spectrometry (MS). Two unexpected mass distributions are observed in the mass spectra. Reaction schemes for the formation of these distributions are proposed. A solution phase trimethylsilane end group modification was performed on the prepolymer to determine whether the unexpected mass distributions occur as impurities from synthesis or as artifacts from the MS process. Evaluation of the TMS modified prepolymer indicates the unexpected mass distributions indeed occur as impurities from the synthetic procedure. Average molecular weight values are determined by traditional GPC, direct MALDI-TOF MS, and GPC-MALDI-TOF MS methods and the results are compared. 相似文献
9.
Four different organic solvents: dimethylformamide, 1,4-dioxane, n-propanol and ethanol were evaluated as alternative organic modifiers to acetonitrile for liquid chromatography (LC) separations. The aim was to establish common sets of chromatographic conditions that could be applied for LC hyphenation to inductively coupled plasma mass spectrometry (ICPMS) as well as to electrospray ionization MS (ESIMS). The approach was to evaluate candidate solvents that, compared to acetonitrile, potentially could give improved analytical performance (low solvent vapor loading, maximized analyte sensitivity and minimized carbon depositions on instrumental parts) in ICPMS analysis while retaining chromatographic and ESIMS performances. The study showed that dimethylformamide, 1,4-dioxane, n-propanol and ethanol all can be advantageous chromatographic modifiers for LC–ICPMS analysis, giving superior performance compared to acetonitrile. For the combined use of LC–ICPMS and LC–ESIMS with a common set of chromatographic conditions, n-propanol gave the best overall performance. The 195Pt+ signal in ICPMS was continuously monitored during a 0–60% organic solvent gradient and at 25% of organic modifier, 100% of the signal obtained at the gradient start was preserved for n-propanol compared to only 35% of the signal when using acetonitrile. Platinum detection limits were 5–8 times lower using n-propanol compared with acetonitrile. Signal-to-noise ratio in continuous ESIMS signal measurements was 100, 90 and 110 for a 100 μg/ml solution of leucine–enkephaline using acetonitrile, ethanol and n-propanol, respectively. Chromatographic efficiency in reversed phase separations was preserved for n-propanol compared to acetonitrile for the analysis of the whole protein cytochrome C and the peptide bacitracin on a column with particle and pore sizes of 5 μm and 300 Å, but slightly deteriorated for the separation of the peptides leucine–enkephaline and bacitracin on a 3 μm and 90 Å column as the peak width at half height for both peptides increased by a factor of two. The performance on the smaller dimensioned column could however be improved by running the separations at 40 °C. 相似文献
10.
Jorge Pisonero Nerea Bordel Claudia Gonzalez de Vega Beatriz Fernández Rosario Pereiro Alfredo Sanz-Medel 《Analytical and bioanalytical chemistry》2013,405(17):5655-5662
The combination of radiofrequency pulsed glow discharge (RF-PGD) analytical plasmas with time-of-flight mass spectrometry (TOFMS) has promoted the applicability of this ion source to direct analysis of innovative materials. In this sense, this emerging technique enables multi-elemental depth profiling with high depth resolution and sensitivity, and simultaneous production of elemental, structural, and molecular information. The analytical potential and trends of this technique are critically presented, including comparison with other complementary and well-established techniques (e.g. SIMS, GD–OES, etc.). An overview of recent applications of RF-PGD–TOFMS is given, including analysis of nano-structured materials, coated-glasses, photovoltaic materials, and polymer coatings 相似文献
11.
Simin Chen Man Yuan Yingling Zhang Yu Xu Hongxi Xu 《Journal of separation science》2023,46(17):2300087
Fuzhuan brick tea, a distinctive dark tea fermented by microorganisms, is a traditional beverage in China throughout history. Recently, it has attracted considerable attention owing to its unique quality characteristics and potential health benefits. The aim of this study was to establish a method for the quality control of Fuzhuan brick tea for stable production. Ultra-high-performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry was used to identify Fuzhuan brick tea, and the major components were chosen for further quantitative analysis. Subsequently, a quantification method was developed using ultra-high-performance liquid chromatography coupled with triple-quadrupole mass spectrometry, and its reliability was verified through methodological validation. Finally, a total of 30 compounds were identified, including catechins, flavonoids, alkaloids, and fatty acids. The established method was reliable for methodological validation and was applied to the quantitative analysis of Fuzhuan brick tea. This study provides a fundamental basis for the quality control and further studies on the component analysis of Fuzhuan brick tea. 相似文献
12.
Linda Ahonen Pekka Keski-Rahkonen Taija Saarelainen Jenni Paviala Raimo A. Ketola Seppo Auriola Matti Poutanen Risto Kostianen 《Analytica chimica acta》2012
The feasibility of a microfluidic-based liquid chromatography-electrospray ionization/mass spectrometric system (HPLC-Chip/ESI/MS) was studied and compared to a conventional narrow-bore liquid chromatography-electrospray ionization/mass spectrometric (LC-ESI/MS) system for the analysis of steroids. The limits of detection (LODs) for oxime derivatized steroids, expressed as concentrations, were slightly higher with the HPLC-Chip/MS system (50–300 pM) using an injection volume of 0.5 μL than with the conventional LC-ESI/MS (10–150 pM) using an injection volume of 40 μL. However, when the LODs are expressed as injected amounts, the sensitivity of the HPLC-Chip/MS system was about 50 times higher than with the conventional LC-ESI/MS system. The results indicate that the use of HPLC-Chip/MS system is clearly advantageous only in the analysis of low-volume samples. Both methods showed good linearity and good quantitative and chromatographic repeatability. In addition to the instrument comparisons with oxime derivatized steroids, the feasibility of the HPLC-Chip/MS system in the analysis of non-derivatized and oxime derivatized steroids was compared. The HPLC-Chip/MS method developed for non-derivatized steroids was also applied to the quantitative analysis of 15 mouse plasma samples. 相似文献
13.
R. Kenneth Marcus Carolyn Q. Burdette Benjamin T. Manard Lynn X. Zhang 《Analytical and bioanalytical chemistry》2013,405(25):8171-8184
A novel approach to ambient desorption/ionization mass spectrometry (ADI-MS) is described, based on a recently developed liquid sampling–atmospheric pressure glow discharge (LS-APGD) ionization source. The device is essentially unmodified relative to its implementation in elemental mass spectrometry, where the operational space is characterized by low operation power (<10 W) and low solution delivery rates (<50 μL min?1). In this implementation, the plasma is produced between a Ni anode and an electrolytic liquid (1 M HNO3) cathode flowing through a glass capillary that is angled towards the sample surface, at a distance of ~2 mm away. Analyte species can be desorbed/ionized from neat solution residues and complex solid samples. The ADI-LS-APGD source is mounted onto the source interface of a Thermo Finnigan LCQ Advantage Max quadrupole ion trap mass spectrometer without modifications to the instrument faceplate or ion optics. Described here is the initial evaluation of the roles of source geometry and working parameters, including electrolytic solution composition and plasma current, on the response of caffeine residues, with preliminary limits of detection based on the relative standard deviation of the spectral background suggested to be on the 10-pg level. Demonstrative spectra are presented for green tea extracts and raw leaves, coffee beans, a dried (raw) tobacco leaf, an analgesic tablet, and paper currency. Versatility is further revealed through the determination of components in common cigarette smoke. In each case, the spectra are characterized by (M?+?H)+ species of the expected constituents. The capacity for a single source to perform both in solution and particulate elemental analysis (as shown previously) and ADI of molecular species is unique in the realm of mass spectrometry. 相似文献
14.
15.
16.
Adrian Boborodea Stephen O’Donohue 《International Journal of Polymer Analysis and Characterization》2017,22(4):305-309
The study presents the possibility of performing the analysis of oligomeric structures and polymer additives by gel permeation chromatography (GPC) with atmospheric pressure chemical ionization (APCI) mass spectrometry (MS) in dibuthoxymethane (DBM, butylal), a halogen-free and less hazardous solvent than typically used chloroform and tetrahydrofuran. Polystyrene oligomers and Irganox® additives were analyzed in DBM using 2.1?mm internal diameter GPC columns, allowing to decrease the flow rate down to 50?µL/min, compatible with APCI–MS interface. The ionization was controlled by adding 1% chloroform in DBM to obtain (M+Cl)? adducts, allowing a fast optimization of method parameters. 相似文献
17.
Manuela Reitz Heike Gerhardt Christian Schmitt Oliver Betz Klaus Albert Michael Lämmerhofer 《Analytica chimica acta》2015
This article reports on the chemical analysis of molecular profiles of tarsal secretions of the desert locust Schistocerca gregaria (Forsskål, 1775) by gas chromatography hyphenated with quadrupol mass spectrometry (GC–MS) as well as 1H-nuclear magnetic resonance (1H NMR) spectroscopy. Special focus of this study was to elaborate on sampling methods which enable selective microscale extraction of insect secretions in a spatially controlled manner, in particular tarsal adhesive secretions and secretions located on cuticle surfaces at the tibia. Various solvent sampling procedures and contact solid-phase microextraction (SPME) methods were compared in terms of comprehensiveness and extraction efficiencies as measured by signal intensities in GC–MS. Solvent sampling with water as extraction solvent gave access to the elucidation of chemical profiles of polar compound classes such as amino acids and carbohydrates, but is extremely tedious. Contact SPME on the other hand can be regarded as a simplified and more elegant alternative, in particular for the lipophilic compound fraction. Many proteinogenic amino acids and ornithine as well as carbohydrate monomers arabinose, xylose, glucose, and galactose were detected in tarsal secretions after acid hydrolysis of aqueous extracts. Qualitatively similar but quantitatively significantly different molecular profiles were found for the lipid fraction which contained mainly n-alkanes and internally branched monomethyl-, dimethyl-, and trimethyl-alkanes in the C23–C49 range as well as long chain fatty acids and aldehydes. Especially, hydrocarbons with >C40 carbon numbers have previously been rarely reported for insect secretions. The results suggest that the investigated insect secretions are complex emulsions which allow the attachment of tarsi on various otherwise incompatible materials of smooth and rough surfaces. The solid consistence of the established alkanes at ambient temperatures might contribute to a semi-solid consistence of the adhesive, amalgamating partly opposing functions such as slip resistance, tarsal release, desiccation resistance, and mechanical compliance. The methods developed can be extended to other similar applications of studying compositions of insect secretions of other species. 相似文献
18.
Milk is an important source of nutrients for various risk populations, including infants. The accurate measurement of vitamin D in milk is necessary to provide adequate supplementation advice for risk groups and to monitor regulatory compliance. Currently used liquid chromatography–tandem mass spectrometry (LC–MS/MS) methods are capable of measuring only four analogues of vitamin D in unfortified milk. We report here an accurate quantitative analytical method for eight analogues of vitamin D: Vitamin D2 and D3 (D2 and D3), 25-hydroxy D2 and D3, 24,25-dihydroxy D2 and D3, and 1,25-dihydroxyD2 and D3. In this study, we compared saponification and protein precipitation for the extraction of vitamin D from milk and found the latter to be more effective. We also optimised the pre-column derivatisation using 4-phenyl-l,2,4-triazoline-3,5-dione (PTAD), to achieve the highest sensitivity and accuracy for all major vitamin D forms in milk. Chromatography was optimised to reduce matrix effects such as ion-suppression, and the matrix effects were eliminated using co-eluting stable isotope labelled internal standards for the calibration of each analogue. The analogues, 25-hydroxyD3 (25(OH)D3) and its epimer (3-epi-25(OH)D3) were chromatographically resolved, to prevent over-estimation of 25(OH)D3. The method was validated and subsequently applied for the measurement of total vitamin D levels in human, cow, mare, goat and sheep milk samples. The detection limits, repeatability standard deviations, and recovery ranges were from 0.2 to 0.4 femtomols, 6.30–13.5%, and 88.2–105%, respectively. 相似文献
19.
20.
Doménech-Carbó MT Osete-Cortina L de la Cruz Cañizares J Bolívar-Galiano F Romero-Noguera J Fernández-Vivas MA Martín-Sánchez I 《Analytical and bioanalytical chemistry》2006,385(7):1265-1280
The alterations produced by microbiological attack on terpenoid resin-based varnishes from panel and canvas paintings have
been evaluated using pyrolysis–gas chromatography–mass spectrometry (Py–GC–MS) and gas chromatography–mass spectrometry (GC–MS).
The proposed methods include the on-line derivatisation of drying oils and diterpenoid resins using hexamethyldisilazane during
pyrolysis and the application of methyl chloroformate as a derivatisation reagent for triterpenoid resins in GC–MS. Two types
of specimens, consisting of model oil medium prepared from linseed oil and model spirit varnishes prepared from colophony
and mastic resins dissolved in turpentine, have been used as reference materials. For a series of specimens upon which different
genera of bacteria and fungi were inoculated and encouraged to grow, analyses indicated that no mechanisms that commonly occur
during the attack of enzymes on drying oils and terpenoid biodegraders were observed to occur in the oil medium and varnishes
studied. Thus, the degradation pathways observed in the performed trials usually occur as consequence of natural ageing. Specific
trials consisting of the application of biocides to uninoculated colophony varnish resulted in the identification of processes
that produce undesirable degradation of the varnish due to interactions between the biocide and the varnish components. Finally,
the studied biocides—Biotin, New-Des and Nipagine—generally exhibited good inhibiting effects on the microorganisms studied,
although some interesting differences were found between them regarding the application method and type of biocide. 相似文献