首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 718 毫秒
1.
Detection of drugs in tissue typically requires extensive sample preparation in which the tissue is first homogenized, followed by drug extraction, before the extracts are finally analyzed by LC/MS. Directly analyzing drugs in intact tissue would eliminate any complications introduced by sample pretreatment. A matrix-assisted laser desorption/ionization tandem mass spectrometry (MALDI-MS n ) method as been developed for the quantification of cocaine present in postmortem brain tissue of a chronic human cocaine user. It is shown that tandem mass spectrometry (MS2 and MS3) increase selectivity, which is critical for differentiating analyte ions from background ions such as matrix clusters and endogenous compounds found in brain tissue. It is also shown that the use of internal standards corrects for signal variability during quantitative MALDI, which can be caused by inhomogeneous crystal formation, inconsistent sample preparation, and laser shot-to-shot variability. The MALDI-MS n method developed allows for a single MS3 experiment that uses a wide isolation window to isolate both analyte and internal standard target ions. This method is shown to provide improved precision [∼10–20 times reduction in percent relative standard deviation (%RSD)] for quantitative analysis compared to using two alternating MS3 experiments that separately isolate the target analyte and internal standard ions.  相似文献   

2.
Sonic spray ionization is shown to create a supersonic cloud of charged droplets able to promote efficient desorption and ionization of drugs directly from the surfaces of commercial drug tablets at ambient conditions. Compared with desorption electrospray ionization (DESI), desorption sonic spray ionization (DeSSI) is advantageous since it uses neither heating nor high voltages at the spray capillary. DeSSI therefore provides a more friendly environment in which to perform ambient mass spectrometry (MS). DeSSI-MS is herein evaluated for the analysis of drug tablets, and found to be, in general, as sensitive as DESI-MS. The (high) voltage-free DeSSI method provides, however, cleaner mass spectra with less abundant solvent cluster ions and with enough abundant analyte signal for tandem mass spectrometry (MS/MS). These features may therefore facilitate the DeSSI-MS detection of low molar mass components or impurities, or both. The higher-velocity supersonic DeSSI spray also facilitates matrix penetration thus providing more homogenous sampling and longer lasting ion signals.  相似文献   

3.
Recently discovered ionization methods for use in mass spectrometry (MS), are widely applicable to biological materials, robust, and easy to automate. Among these, matrix assisted ionization vacuum (MAIV) is astonishing in that ionization of low and high-mass compounds are converted to gas-phase ions with charge states similar to electrospray ionization simply by exposing a matrix:analyte mixture to the vacuum of a mass spectrometer. Using the matrix compound, 3-nitrobenzonitrile, abundant ions are produced at room temperature without the need of high voltage or a laser. Here we discuss chemical analyses advances using MAIV combined with ion mobility spectrometry (IMS) real time separation, high resolution MS, and mass selected and non-mass selected MS/MS providing rapid analyte characterization. Drugs, their metabolites, lipids, peptides, and proteins can be ionized simultaneously from a variety of different biological matrixes such as urine, plasma, whole blood, and tissue. These complex mixtures are best characterized using a separation step, which is obtained nearly instantaneously with IMS, and together with direct ionization and MS or MS/MS provides a fast analysis method that has considerable potential for non-targeted clinical analyses.  相似文献   

4.
Direct analysis in real time (DART) is an ambient ionization technique undergoing rapid development. With minimal sample pre-treatment, ionization of analyte molecules outside the mass spectrometry (MS) instrument in the ordinary atmosphere is feasible. This ionization approach relies upon the fundamental principles of atmospheric pressure chemical ionization.The current review highlights and critically assesses application of DART (and some related desorption/ionization techniques) coupled to various types of MS analyzers for both target and non-target analysis of complex food matrices. Based on existing studies, DART-MS is presented as a simple, high-throughput tool for:
(i)
qualitative confirmation of chemical identity;
(ii)
metabolomic fingerprinting/profiling; and,
(iii)
quantification of low-molecular-weight food components, including some trace organic contaminants.
With regard to regulatory requirements, we mention practical aspects of DART-MS use, as well as performance characteristics that can be attained.  相似文献   

5.
Paper spray has been developed as a fast sampling ionization method for direct analysis of raw biological and chemical samples using mass spectrometry (MS). Quantitation of therapeutic drugs in blood samples at high accuracy has also been achieved using paper spray MS without traditional sample preparation or chromatographic separation. The paper spray ionization is a process integrated with a fast extraction of the analyte from the raw sample by a solvent, the transport of the extracted analytes on the paper, and a spray ionization at the tip of the paper substrate with a high voltage applied. In this study, the influence on the analytical performance by the solvent–substrate systems and the selection of the elution methods was investigated. The protein hemoglobin could be observed from fresh blood samples on silanized paper or from dried blood spots on silica-coated paper. The on-paper separation of the chemicals during the paper spray was characterized through the analysis of a mixture of the methyl violet 2B and methylene blue. The mode of applying the spray solvent was found to have a significant impact on the separation. The results in this study led to a better understanding of the analyte elution, on-paper separation, as well as the ionization processes of the paper spray. This study also helps in establishing a guideline for optimizing the analytical performance of paper spray for direct analysis of target analytes using mass spectrometry.  相似文献   

6.
Large-scale mass spectrometry (MS)-based proteomic analyses require high-throughput sample preparation techniques due to the increasing numbers of samples that make up a typical proteomics experiment. Moreover, extensive sample pre-treatment steps are necessary prior to MS acquisition for even the most rapid and robust MS-based proteomics methodology, matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS followed by peptide mass fingerprinting (PMF) analysis. These include sample purification and fractionation, removal of digestion buffers or solvents, and spotting of sample with matrix onto the MALDI target. These multiple steps of time-consuming sample handling can result in high overall analysis costs and the likelihood of sample contamination and loss. In order to overcome some of these limitations in sample processing, we have investigated the use of a novel, simple, inexpensive 96-well elastomeric array that affixes to a MALDI target to create an on-target 96-well plate that accommodates a high solution volume (ca. 200 microL), thereby enabling the on-target processing of samples for MALDI-TOFMS. We explored several factors that influence MALDI sample preparation: type of matrix, solution volume, solution organic composition, solution drying rates and matrix/analyte co-crystallization methods. We also investigated the use of the 96-well elastomeric device for coupling MALDI-TOFMS analysis directly to high flow rate (1 mL/min) reversed-phase (rp)-HPLC. By developing an optimized, robust sample preparation protocol, we were able to obtain mass spectra with a high signal-to-noise ratio from peptide standards present at the 50-fmol level in large starting volumes of solution. PMF analyses were possible from 1-pmol and 500-fmol protein-digest standards. Coupling the device to high-flow HPLC (750 microL/min) yielded a robust and semi-automated means to obtain enhanced MALDI-TOFMS data at 500 ng of protein digest. These methodologies developed for this simple, on-target, elastomeric device show promise for streamlining the sample preparation process from HPLC to MALDI-MS.  相似文献   

7.
This paper presents a study of the signal suppression and enhancement effects in assays based on HPLC-ESI-MS/MS detection. The major focus was to investigate the effect of signal suppression/enhancement of typical co-administered (concomitant) medications, i.e. naproxen and ibuprofen. The results demonstrate that the analyte and internal standard can experience signal enhancement up to a factor of ca 2.9 if the test analyte or internal standard co-elute with concomitant. Experimental results also demonstrate that the analyte and internal standard signal increased by a factor of ca 2.0 in the negative ion mode at physiological relevant levels of naproxen (100 microg/mL) and by a factor of ca 1.6 in the negative ion mode at physiological relevant level of ibuprofen (10 microg/mL) in both neat and plasma samples. Signal enhancement significantly increased when concomitant medications ionized in the same ion mode as the analyte and internal standard. To overcome signal enhancement or potential suppression from concomitant medications, a comprehensive HPLC method needs to be developed with sufficient separation of concomitant medication from the analyte and internal standard. Other means to reduce signal enhancement or potential suppression include switching ionization polarity and performing comprehensive sample clean-up to remove concomitant medications before analysis.  相似文献   

8.
2,5-Dihydroxyacetophenone (DHAP) is presented as a matrix which enables highly sensitive matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometric analysis of peptides, proteins and glycoproteins on AnchorChip targets. Depending on the protein, lower fmol amounts can be detected due to the increased homogeneity and concentration of the crystallization of the analyte/matrix mixture on the anchors. Best results could be generated in the mass range of 8-100 kDa. All sample/matrix preparation steps starting from mixing of DHAP matrix solution with sample solution to the transfer of the mixture to the MALDI-TOF target can be performed manually or automatically allowing low- and high-throughput analyses.  相似文献   

9.
Ambient desorption ionization mass spectrometry   总被引:1,自引:0,他引:1  
Ambient desorption ionization mass spectrometry (MS) allows for the direct analysis of ordinary objects in the open atmosphere of the laboratory or in their natural environment. Analyte desorption usually accompanies the ionization step and these processes are often concerted, multi-step processes. Ambient desorption ionization methods typically require little or no sample preparation, offer a much simplified work flow and deliver unprecedented ease of use to MS analyses.

Since the introduction of desorption electrospray ionization (DESI [Z. Takats, J.M. Wiseman, B. Gologan, R.G. Cooks, Science (Washington, D. C.) 306 (2004) 471]) in 2004 and the direct analysis in real time (DART [R.B. Cody, J.A. Laramee, H.D. Durst, Anal. Chem. 77 (2005) 2297]) in 2005, this new field of MS has developed rapidly. Numerous permutations of the various options for analyte desorption and ionization have been demonstrated. Desorption steps, such as momentum transfer, dissolution into ricocheting droplets and thermal desorption, have been combined with ionization steps, including ESI, atmospheric pressure chemical ionization and photo-ionization. The large number of possible combinations of desorption and ionization components that have already been applied is creating a proliferation of techniques and acronyms that is becoming ever more complex.

Here, we provide a logical framework for the classification of these related experiments, based on the desorption and ionization processes involved in each.  相似文献   


10.
Three plasma-based ambient pressure ion sources were investigated; laboratory constructed dielectric barrier and rf glow discharges, as well as a commercial corona discharge (DART source). All were used to desorb and ionize a model analyte, providing sampling techniques for ambient mass spectrometry (MS). Experimental parameters were optimized to achive highest signal for acetaminophen as the analyte. Insight into the mechanisms of analyte desorption and ionization was obtained by means of emission spectrometry and ion current measurements. Desorption and ionization mechanisms for this analyte appear to be identical for all three plasma sources. Emission spectra differ only in the intensities of various lines and bands. Desorption of solid analyte requires transfer of thermal energy from the plasma source to sample surface, in the absence of which complete loss of MS response occurs. For acetaminophen, helium was the best plasma gas, providing 100- to 1000-fold higher analyte response than with argon or nitrogen. The same trend was also evident with background ions (protonated water clusters). MS analyte signal intensity correlates with the ion density (expressed as ion current) in the plasma plume and with emission intensity from excited state species in the plasma. These observations support an ionization process which occurs via proton transfer from protonated water clusters to analyte molecules.  相似文献   

11.
The role of helium addition on the analyte signal enhancement in laser-induced breakdown spectroscopy for analysis of pure gaseous systems was examined using carbon and hydrogen atomic emission lines. Increased analyte response, as measured by peak-to-base and signal-to-noise ratios, was observed with increasing helium addition, with maximum enhancement approaching a factor of 7. Additional measurements revealed a significant decrease in plasma electron density with increasing helium addition. To explore the mechanisms of analyte signal enhancement, the helium emission lines were also examined and found to be effectively quenched with nitrogen addition. In consideration of the data, it is concluded that the role of metastable helium is not as important as the overall changes in plasma properties, namely electron density and laser-plasma coupling. Helium addition is concluded to affect the electron density via Penning ionization, as well as to play a role in the initial plasma breakdown processes.  相似文献   

12.
Matrix‐assisted laser desorption/ionization (MALDI) is a soft ionization technique that when used to analyze synthetic polymer analytes often requires the addition of a metal cationization agent (herein termed the “salt”). The choice of both the matrix and the cationization agent needs to be taken into account when considering the polymer under study; different polymers have shown different affinities toward different cationization agents, and their selectivity can change as the matrix changes. Salt‐to‐analyte ratio (S/A) plots are used in this work to investigate the effect of the quantity of cationization agent employed in the analysis of a poly (methylmethacrylate) (PMMA) analyte with different MALDI matrices. The point at which analyte signal stops increasing with the added cationization agent is termed the “cation saturation point,” and it was found to occur around a S/A of 1. When the analyte signal after this point remains constant, it is termed an “ideal case.” The “non‐ideal case” occurs when the analyte signal decreases after the cation saturation point. The amount of matrix present (measured as the matrix‐to‐analyte molar ratio, M/A) and the use of different counterions for the salt are also found to affect the intensity of the analyte signal. In non‐ideal cases, changes in the counterion or an increase in the M/A are found to increase the analyte signal, often converting an initially observed non‐ideal case into an ideal case. Several experiments attempting to uncover the reason for observation of the non‐ideal S/A behavior are also described.  相似文献   

13.
Hu B  Yang S  Li M  Gu H  Chen H 《The Analyst》2011,136(18):3599-3601
The high-throughput and sensitive characterization of native proteins in biological samples is of increasing interest in multiple disciplines. Extractive electrospray ionization (EESI) forms ions of native proteins including lysozyme, α-chymotrypsin, myoglobin, human serum albumin, RNAse A and blood hemoglobin in extremely complex biosamples or PBS buffer solutions by softly depositing charges on the protein molecules. This method produces no significant conformational changes of the proteins in the ion formation process, and features direct detection of trace proteins present in biological matrices. The detection limit of low pmol L(-1) for lysozyme in untreated biological liquids such as human urine and tears was demonstrated using EESI mass spectrometry (MS), showing an attractive MS platform for the direct analysis of native proteins in actual biological samples.  相似文献   

14.
《Analytical letters》2012,45(16):2553-2565
Online matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is reported with in situ matrix/analyte aerosol mixing. The analyte and matrix were dissolved in separate solvents and pneumatically atomized into particles. Continuous flows of analyte particles and matrix droplets in nitrogen were mixed in a tee. The resulting particles were sampled using a nozzle, focused into a beam with an aerodynamic lens system, and vertically deposited continuously on a movable target. The matrix/analyte mixture was desorbed/ionized using a 266 nanometers pulsed laser at an incident angle of 45°. The nascent ions were analyzed using reflectron TOF MS. The performance of online MALDI-TOF MS was evaluated by the analysis of palmityl palmitate with the lithium salt of 2, 4-dihydroxybenzoic acid as the matrix. Strong and stable MALDI signals of palmityl palmitate were obtained. The matrix solvent mixture and the analyte concentration were optimized and the results demonstrate the development of an alternative for online MALDI analysis.  相似文献   

15.
Implementation of DART and DESI ionization on a fieldable mass spectrometer   总被引:1,自引:1,他引:0  
A recently developed prototype mobile laboratory mass spectrometer, incorporating an atmospheric pressure ionization (API) interface, is described. This system takes advantage of the small size, lower voltage requirements, and tandem MS abilities of the cylindrical ion trap mass analyzer. The prototype API MS uses small, low-power pumps to fit into a 0.1-m(3) self-contained package weighing <45 kg. This instrument has been adapted to allow rapid interfacing to electrospray ionization, desorption electrospray ionization, and direct analysis in real-time sources. Initial data indicate that these techniques provide rapid detection and identification of compounds for quality control, homeland security, and forensic applications. In addition, this instrument is self-contained and compact, making it ideally extensible to mobile laboratory and field analyses. Initial MS and MS/MS data for analyses of drugs, food, and explosives are presented herein.  相似文献   

16.
Coordination complexes containing Ce(III) and tri-n-butyl phosphate (TBP) in the 1+, 2+ and 3+ charge states were generated using both direct infusion electrospray ionization (ESI) and fused droplet (FD) ESI using a target capillary, in which the analyte solutions are impinged by the ESI droplets. The same coordination complexes were produced in each experiment, and their relative abundances were also very close, suggesting that similar processes are occurring in both experiments. The ion species formed in both experiments have the general formula [Ce(NO(3) )(m=0-2) (TBP)(n=3-7) ]((3-m)+) . The appearance of abundant 1+ and 2+ ion pair complexes indicated that the ESI process was modifying the ion populations in the original solutions, which contain predominantly 3+ and 2+ species. The FD ESI experiments were less sensitive for coordination complexes compared to direct infusion ESI; however, mid-picomolar quantities of coordination complexes were measured using the target capillary, indicating that sensitivity would be sufficient for measuring species in many industrial separations processes.  相似文献   

17.
With advancements in ionization methods and instrumentation, liquid chromatography/mass spectrometry (LC/MS) has become a powerful technology for the characterization of small molecules and proteins. This article will illustrate the role of LC/MS analysis in drug discovery process. Examples will be given on high-throughput analysis, structural analysis of trace level impurities in drug substances, identification of metabolites, and characterization of therapeutic protein products for process improvement. Some unique MS techniques will also be discussed to demonstrate their effectiveness in facilitating structural identifications.  相似文献   

18.
Coupling immunoassays on self-assembled monolayers (SAMs) to matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) provides improved assay selectivity compared with traditional photometric detection techniques. We show that thin-layer-transfer (TLT) of ??-cyano-4-hydroxycinnaminic acid (CHCA) MALDI matrix via vacuum sublimation followed by organic solvent-based vapor-sorption induced co-crystallization (VIC) results in unique matrix/analyte co-crystallization tendencies that optimizes assay reproducibility and sensitivity. Unique matrix crystal morphologies resulted from VIC solvent vapors, indicating nucleation and crystal growth characteristics depend upon VIC parameters. We observed that CHCA microcrystals generated by methanol VIC resulted in >10× better sensitivity, increased analyte charging, and improved precision compared with dried droplet measurements. The uniformity of matrix/analyte co-crystallization across planar immunoassays directed at intact proteins yielded low spectral variation for single shot replicates (18.5?% relative standard deviation, RSD) and signal averaged spectra (<10?% RSD). We envision that TLT and VIC for MALDI-TOF will enable high-throughput, reproducible array-based immunoassays for protein molecular diagnostic assays in diverse biochemical and clinical applications.  相似文献   

19.
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) is a soft ionization MS technique providing only minor fragmentation of the analyte. Therefore, the method is basically suitable for mixture analysis, although the ion yields strongly depend on the basicity/acidity of the analyte in relation to the applied matrix. Accordingly, less sensitively detectable compounds may be suppressed by more sensitively detectable compounds. Thus, separation of the mixture into the individual compounds is normally indispensable. This paper demonstrates the capabilities and limitations of a direct, simple, and inexpensive MALDI-high-performance thin-layer chromatography (HPTLC) coupling for the analysis of a crude lipid extract from porcine brain. Brain lipids were chosen because they represent a rather complex mixture and are of currently significant research interest. It was found that normal-phase HPTLC-separated lipids can be easily characterized by direct MALDI-TOF-MS analysis with sufficient resolution to allow the assignment of virtually all lipid classes, even rather minor species such as phosphorylated phosphoinositides or complex glycolipids as gangliosides. Advantages and disadvantages of this approach are discussed.  相似文献   

20.
A method for determination of fat-soluble vitamins K(1), K(3), A, D(2), D(3) and E (as alpha- and delta-tocopherol) and metabolites 25-hydroxyvitamin D(2) and D(3) and 1,25-dihydroxyvitamin D(3) in human serum by liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) in positive mode is proposed. Highly selective identification of the target compounds in serum was confirmed by the most representative transitions from precursor ion to product ion. Quantitative MS/MS analysis was carried out by multiple reaction monitoring optimizing the most sensitive transition for each analyte in order to achieve low detection limits (from 0.012 to 0.3 ng/mL estimated with serum). The analysis was performed with 1 mL of serum, which was subjected to protein precipitation, liquid-liquid extraction to an organic phase, evaporation to dryness and reconstitution with methanol. The precision of the overall method ranged from 3.17-6.76% as intra-day variability and from 5.07-11.53% as inter-day variability. The method, validated by the standard addition method, provides complete information on the fat-soluble vitamins profile, which is of interest in clinical and metabolomics studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏