共查询到20条相似文献,搜索用时 0 毫秒
1.
Development of a solid-phase extraction method for the determination of polychlorinated biphenyls in water 总被引:1,自引:0,他引:1
Westbom R Thörneby L Zorita S Mathiasson L Björklund E 《Journal of chromatography. A》2004,1033(1):1-8
Polychlorinated biphenyls (PCBs) in water were extracted with a rebuilt extraction unit using 47 mm C18 solid-phase extraction (SPE) disks. Three types of disks (SPEC, ENVI and Empore) were investigated for the extraction of seven PCBs from 11 reagent water spiked at two concentration levels (20 and 1000 ng/l). The Empore disks produced the best analyte recoveries (91-107% with R.S.D. of 1-8%) at the low concentration level and displayed no leaking tendency. Empore disks were therefore considered superior to ENVI and SPEC disks for the conditions outlined in this work. The obtained extracts were dried and purified in an additional clean-up step using custom-made columns containing Florisil and Na2SO4. For water containing large amounts of organic matter, a pre-filtration was included. Final analysis was carried out on a dual-column GC-electron-capture detection system with on-column injection. The optimised extraction method, including clean-up, was less time-consuming and used less hazardous organic solvents than conventional liquid-liquid extraction (LLE) methods. Recoveries were 92-102% with R.S.D. of 3-8%. 相似文献
2.
建立了以羧基化多壁碳纳米管(MWCNTs-COOH)和N-丙基乙二胺(PSA)为分散固相萃取吸附剂的前处理净化技术,结合气相色谱-质谱(GC-MS)同时检测茶叶中18种多氯联苯(PCBs)的方法。茶叶样品经正己烷-丙酮(1:1,v/v)超声提取后,通过甲苯溶剂置换,以MWCNTs-COOH和PSA混合吸附剂净化,采用电子轰击离子源、选择离子监测模式测定,以保留时间和特征离子丰度比定性,基质匹配标准溶液外标法定量。考察了提取溶剂及吸附剂种类和用量、提取时间和净化时间对分析结果的影响,优化了气相色谱-质谱条件,并评估了优化实验条件下的方法性能。在最优实验条件下,18种PCBs在5~500 μg/kg范围内线性关系良好,相关系数(r)不低于0.9998;当加标水平为5、10和100 μg/kg时,3种茶叶基质中18种PCBs的平均回收率为90.7%~115.2%,相对标准偏差(n=5)为0.3%~10.9%;方法的检出限为0.3~1.7 μg/kg,定量限均为5 μg/kg。该方法操作简单、快速,准确可靠、灵敏度高,样品净化效果好,可用于不同种类茶叶基质中18种PCBs的测定。 相似文献
3.
Shiliang Jia Zhenhua Wang Ning Ding Y.-L. Elaine Wong Xiangfeng Chen Guangyu Qiu T.-W. Dominic Chan 《Analytica chimica acta》2016
The adsorptive potential of hexagonal boron nitride nanosheets (h-BNNSs) for solid-phase extraction (SPE) of pollutants was investigated for the first time. Seven indicators of polychlorinated biphenyls (PCBs) were selected as target analytes. The adsorption of PCBs on the surface of the h-BNNSs in water was simulated by the density functional theory and molecular dynamics. The simulation results indicated that the PCBs are adsorbed on the surface by π–π, hydrophobic, and electrostatic interactions. The PCBs were extracted with an h-BNNS-packed SPE cartridge, and eluted by dichloromethane. Gas chromatography–tandem mass spectrometry working in the multiple reaction monitor mode was used for the sample quantification. The effect of extraction parameters, including the flow rate, pH value, breakthrough volume, and the ionic strength, were investigated. Under the optimal working conditions, the developed method showed low limits of detection (0.24–0.50 ng L−1; signal-to-noise ratio = 3:1), low limits of quantification (0.79–1.56 ng L−1; signal-to-noise ratio = 10:1), satisfactory linearity (r > 0.99) within the concentration range of 2–1000 ng L−1, and good precision (relative standard deviation < 12%). The PCBs concentration in environmental water samples was determined by the developed method. This results demonstrate that h-BNNSs have high analytical potential in the enrichment of pollutants. 相似文献
4.
Summary An effective, multiresidue-matrix, solid-phase dispersion — extraction (MSPD) and GC-MS method for the determination of 16 organochlorine pesticides (OCPs), as well as polychlorinated biphenyls (PCBs) from the level chlorination in fish is described. The method uses an octadecylsilyl-derivatized silica and Florisil-based MSPD co-column for direct, on-line clean-up. Recoveries calculated from five different fortification levels are >85% in all cases for OCPs, except for heptachlor and 4,4-DDT where recoveries of 78% and 81% are ob-tained, and >95% for PCBs. Detection limits determined for the OCPs vary from 19.6–91.1 ng g–1, and from 71.4–111.2 ng g–1 for the two to five chlorine-containing PCBs. The method has been applied to the analysis of fish grown in Er-Jen river (Taiwan) and method may serve as a screening protocol for the determination of OCPs and PCBs in fish. 相似文献
5.
By monomer-mediated in-situ growth synthesis strategy, with hydroquinone and 1,3,5-tris(4-aminophenyl)benzene as monomers, a core-shell magnetic porous organic polymer was synthesized through a simple azo reaction. Based on this, a magnetic solid-phase extraction–high-performance liquid chromatography–fluorescence detection method was proposed for the analysis of fluoroquinolones in a honey sample. With ofloxacin, ciprofloxacin, enrofloxacin, lomefloxacin, and difloxacin as target analytes, factors affecting the extraction efficiency had been optimized. The LODs were 1.5–5.4 ng/L (corresponding to 0.23–0.81 μg/kg in honey). The linear range was 0.005–20 μg/L for difloxacin, 0.01–20 μg/L for ofloxacin, ciprofloxacin and lomefloxacin, and 0.02–20 μg/L for enrofloxacin. The enrichment factor was 84.4–91.7-fold with a high extraction efficiency of 84.4–91.7%. The method was assessed by the analysis of target fluoroquinolones in honey samples, and the recoveries for the spiked samples were 79.3–95.8%. The results indicated that the established magnetic solid-phase extraction–high-performance liquid chromatography–fluorescence detection method is efficient for the analysis of trace fluoroquinolones in honey. 相似文献
6.
《Journal of separation science》2017,40(23):4583-4590
A fast and sensitive analytical method based on stir bar sorptive extraction technology with gas chromatography and mass spectrometry was developed to simultaneously analyze 18 kinds of polychlorinated biphenyls and 20 kinds of organochlorine pesticides in aqueous samples. A long adsorption time and small sample volume, which are problems encountered in conventional methods of stir bar sorptive extraction, were effectively solved by simultaneously using multiple stir bars for enrichment with sequential cryofocusing and merged injection. Optimized results showed good linear coefficients in the range of 10–500 ng/L and the method detection limits of 0.12–2.07 ng/L for polychlorinated biphenyls and organochlorine pesticides. The recovery ratios of the spiked samples at different concentrations were between 64.7 and 111.0%, and their relative standard deviations ranged from 0.9 to 17.6%. Four types of the studied compounds were determined in Qiantang River water samples, and their contents were between 0.82 and 5.00 ng/L. 相似文献
7.
Xiaoyan Cui Yujiao Wang Yumei Yan Zilin Meng Runhua Lu Haixiang Gao Canping Pan Xinlin Wei Wenfeng Zhou 《Journal of separation science》2022,45(4):908-918
In this study, a 4-formylphenylboronic acid-modified cross-linked chitosan magnetic nanoparticle (FPBA@CCHS@Fe3O4) was fabricated. The synthesized material was utilized as the magnetic solid-phase extraction adsorbent for the enrichment of six benzoylurea pesticides. In addition to B-N coordination, FPBA@CCHS@Fe3O4 interacts with benzoylureas through hydrogen bonds and π-π stacking interaction on account of rich active groups (amino and hydroxyl) and aromatic rings in structure. Compared to traditional extraction methods, less adsorbent (20 mg) and reduced extraction time (3 min) were achieved. The adsorbent also exhibited good reusability (no less than 10 times). Coupled with a high-performance liquid chromatography–diode array detector, satisfactory recoveries (89.1–103.9%) and an acceptable limit of detection (0.2–0.7 μg/L) were obtained. Under optimized conditions, the established method was successfully applied to the tea infusion samples from six major tea categories with acceptable recoveries ranging from 76.8 to 110%, indicating its application potential for the quantitative detection of pesticides in complex matrices. 相似文献
8.
A solid-phase extraction (SPE) method was optimized for accurate determination of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and coplanar polychlorinated biphenyls (CoPCBs) in humic acid containing surface water. Recovery experiments using humic materials revealed that humic acids permit dioxins to pass through an octadecylsilica (C18) extraction disk by associating with them under weakly alkaline conditions. Acidification of the sample before percolation improved this otherwise insufficient recovery. The analysis of surface water acidified to pH 2 gave better recovery with surrogate standards and lower quantitative values for higher-chlorinated homologues than the sample at pH 9. In all samples, the native octachlorodibenzo-p-dioxin (OCDD) peak abundance showed no difference between at pH 2 and at pH 9, indicating overestimation of the quantitative value of the homologue at pH 9. Acidification of a humic acid containing water sample can avoid overestimation of higher-chlorinated congeners caused by insufficient recovery of their corresponding surrogates. 相似文献
9.
Analysis of polychlorinated biphenyls in aqueous samples by microwave-assisted headspace solid-phase microextraction 总被引:2,自引:0,他引:2
The hyphenated technique namely microwave-assisted headspace solid-phase microextraction (MA-HS-SPME) was developed and studied for the simultaneous extraction/enrichment of polychlorinated biphenyls (PCBs) in aqueous samples prior to the quantification by gas chromatography (GC). The PCBs in aqueous media are extracted onto a solid-phase micro fibre via the headspace with the aid of microwave irradiation. The optimum conditions for obtaining extraction efficiency, such as the extraction time, addition of salts, addition of methanol, ratio of sample to headspace volume, and the desorption parameters were investigated. Experimental results indicated that the proposed MA-HS-SPME method attained the best extraction efficiency under the optimized conditions, i.e., irradiation of extraction solution (20 ml aqueous sample in 40 ml headspace vial with no additions of salt and methanol) under 30 W microwave power for 15 cycles (1 min power on and 3 min power off of each cycle). Desorption at 270 degrees C for 3 min provided the best detection results. The detection limit obtained were between 0.27 and 1.34 ng/l. The correlation coefficient for the linear dynamic range from 1 to 80 ng/l exceeded 0.99 for 18 PCBs. 相似文献
10.
《Journal of separation science》2017,40(16):3279-3288
A simple, rapid, and novel method has been developed and validated for determination of seven indicator polychlorinated biphenyls in water samples by gas chromatography with electron capture detection. 1 L of water samples containing 30 g of anhydrous sodium sulfate was first liquid–liquid extracted with an automated Jipad‐6XB vertical oscillator using n‐hexane/dichloromethane (1:1, v/v). The concentrated extract was cleaned up by dispersive solid‐phase extraction with 100 mg of primary secondary amine as sorbent material. The linearity of this method ranged from 1.25 to 100 μg/L, with regression coefficients ranging between 0.9994 and 0.9999. The limits of detection were in the ng/L level, ranging between 0.2 and 0.3 ng/L. The recoveries of seven spiked polychlorinated biphenyls with external calibration method at different concentration levels in tap water, lake water, and sea water were in the ranges of 85–112, 76–116, and 72–108%, respectively, and with relative standard deviations of 3.3–4.5, 3.4–5.6, and 3.1–4.8% (n = 5), respectively. The performance of the proposed method was compared with traditional liquid–liquid extraction and solid‐phase extraction clean‐up methods, and comparable efficiencies were obtained. It is concluded that this method can be successfully applied for the determination of polychlorinated biphenyls in different water samples. 相似文献
11.
Guangzhu Li Chao Geng Zhuan Li Xi Tian Shengshu Ai 《International journal of environmental analytical chemistry》2017,97(7):657-672
The sulfhydryl-functionalised core-shell Fe3O4@SiO2 magnetic nanoparticles (Fe3O4@SiO2–RSH MNPs)-based dispersive solid-phase extraction method was developed. The goal of this method is the extraction of mercury species from natural water samples. An interesting aspect of the method is that, thanks to the spontaneously aggregate, the MNPs with a sub-30-nm-size range could be fast and efficiently extracted by 0.45 μm pore size mixed cellulose esters membrane filter. Thus, the elution step can be conducted by passing small amounts eluent through the MNPs on the membrane. It is also found that addition of Ag+ to water sample could improve the elution efficiency, and furthermore, minimises the matrix effects during the extraction of mercury species from natural water samples. The feasibility of the method was studied, and extraction efficiency was evaluated. The results showed that, calculated at 5 ng/L spiked concentration levels, absolute recoveries were 89.4%, 91.9% and 64.2%, and enrichment factors (EFs) were 596, 613 and 428, for inorganic mercury, methylmercury and ethylmercury, respectively. The high EFs were achieved in 5 min of overall extraction time. The method was applied to groundwater and river water samples. The results showed that its suitability for use in fast extracting trace levels of mercury species from natural water samples. 相似文献
12.
微波辅助萃取-气相色谱测定土壤中多氯联苯 总被引:2,自引:0,他引:2
建立了微波辅助萃取-气相色谱-微电子捕获检测土壤样品中6种多氯联苯(pcb28, pcb52, pcb101, pcb138, pcb153和pcb180)的方法. 确定了以V(20 mL丙酮):V(正己烷)=1:1混合溶剂作萃取剂, 萃取温度110 ℃, 仪器功率800 W, 微波萃取5 min的样品前处理条件, 并用柱温程序优化了GC-μECD分析条件. 方法的检出限为0.027~0.087 ng/g; 相对标准偏差为3.4%~7.6% (n=6); 加标平均回收率79.8%~91.1%. 可用于土壤环境中多氯联苯的监测分析. 相似文献
13.
Amirhassan Amiri Hamid Reza Saadati-Moshtaghin Abbas Abdar Farokhzad Mohammadi Zonoz 《International journal of environmental analytical chemistry》2013,93(11):1017-1029
ABSTRACTIn this work, the magnetic sorbent was developed by covalent binding of a Schiff base ligand, N,N’-bis(3-salicyliden aminopropyl)amine (salpr), on the surface of silica coated magnetic nanoparticles (Salpr@SCMNPs). The core-shell nanoparticle was applied for the magnetic solid-phase extraction (MSPE) combined with dispersive liquid-liquid microextraction (DLLME) of phenolic compounds from water samples prior to gas chromatography-flame ionisation detector (GC?FID). Characterisation of the Salpr@SCMNPs was performed with different physicochemical methods such as Fourier transform infrared (FT-IR), scanning electron microscopy (SEM) and vibrating sample magnetometer (VSM). Variables affecting the performance of both extraction steps such as pH of the water sample, the sorbent amount, the desorption conditions, the extraction time; and extraction solvent were studied. Under the optimised conditions, the analytical performances were determined with a linear range of 0.01–100 ng mL?1 and a limit of detection at 0.003–0.02 ng mL?1 for all of the analytes studied. The intra-day (n = 5) and inter-day (n = 3) relative standard deviations (RSD%) of three replicates were each demonstrated in the range of 6.9–8.9% and 7.3–10.1%, respectively. The proposed method was executed for the analysis of real water samples, whereby recoveries in the range of 92.9–99.0% and RSD% lower than 6.1% were attained. 相似文献
14.
Miniaturised ultrasonic solvent extraction procedure was developed for the determination of selected polychlorinated biphenyls (PCBs) in soil samples by gas chromatography-mass-selective detection by using 23 factorial experimental design. Recoveries of PCBs from fortified soil samples are over 90% for three different fortification levels between 40 and 120 μg kg−1, and relative standard deviations of the recoveries are below 7%. The limits of detection (LODs) ranged from 0.003 to 0.006 μg kg−1. The performance of the proposed method was compared to traditional shake flask extraction method on the spiked real soil sample and extraction methods showed comparable efficiencies. Proposed miniaturised ultrasonic solvent extraction offers several advantages, i.e., reducing sample requirement for measurement of target compound, less solvent consumption and reducing the costs associated with solvent purchase and waste disposal. 相似文献
15.
Qingxiang Zhou Wei Wu Junping Xiao 《International journal of environmental analytical chemistry》2013,93(8):894-905
This paper describes a simple, rapid and sensitive method for the determination of polychlorinated biphenyls (PCBs) including PCB-28, PCB-52, PCB-101, PCB-138, PCB-153 and PCB-180 using silicon dioxide microspheres solid phase extraction cartridge prior to gas chromatography with electron capture detector. The experimental results indicate that there were excellent linear relationships between the peak areas and the concentrations of polychlorinated biphenyls, and the linear ranges were in the concentration range of 0.1 to 30?µg?L?1 with the correlation coefficients in the range of 0.9962 to 0.9998. The detection limits were in the range of 0.003 to 0.019?µg?L?1. The precisions of the proposed method were below 10% (n?=?6). The enrichment factors, described as the ratio of the slope of the calibration curves with and without extraction, were in the range of 605.2 to 1414.6. The proposed method was used to analyse the real water samples, and satisfactory spiked recoveries in the range of 80 to 117% were achieved. These results demonstrated that silicon dioxide microspheres without modification were good adsorbent for the enrichment of polychlorinated biphenyls and the developed method were of great value and would be a good alternative for the routine analysis of polychlorinated biphenyls in the future. 相似文献
16.
建立了气相色谱-负化学电离源质谱(GC-NCI-MS)同时测定鱼油中16种多氯联苯(PCBs)的方法。鱼油样品经正己烷提取和浓硫酸净化,在选择离子监测模式下进行GC-NCI-MS检测。所检测的PCBs在0.01~10 μg/L范围内呈现良好的线性关系(r>0.99),定量限(S/N=10)在3~67 pg/g之间。基质加标回收率为62.3%~121.8%,相对标准偏差(n=3)≤12%。相比传统的多种填料固相萃取前处理法,本方法样品处理简单快速,有机溶剂使用量少,具有较好的抗基质干扰能力和较高的灵敏度,适用于鱼油中痕量共平面多氯联苯及常见指示性多氯联苯等的同时检测。 相似文献
17.
18.
Petr Suchan Jana Pulkrabov Jana Haj
lov Vladimír Kocourek 《Analytica chimica acta》2004,520(1-2):193-200
Pressurized liquid extraction (PLE) is a relatively new technique applicable for the extraction of persistent organic pollutants from various matrices. The main advantages of this method are short time and low consumption of extraction solvent. The effects of various operational parameters (i.e. temperature of extraction, number of static cycles and extraction solvent mixtures) on the PLE efficiency were investigated in this study. Fish muscle tissue containing 3.2% (w/w) lipids and native polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and other related compounds was used for testing. Purification of crude extracts was carried out by gel permeation chromatography employing Bio-Beads S-X3. Identification and quantitation of target indicator PCBs and OCPs was performed by high-resolution gas chromatography (HRGC) with two parallel electron-capture detectors (ECDs). Results obtained by the optimized PLE procedure were compared with conventional Soxhlet extraction (the same extraction solvent mixtures hexane–dichloromethane (1:1 v/v) and hexane–acetone (4:1 v/v) were used). The recoveries obtained by PLE operated at 90–120 °C were either comparable to “classic” Soxhlet extraction (for higher-chlorinated PCB congeners and DDT group) or even better (for lower chlorinated analytes). The highest recoveries were obtained for three static 5 min extraction cycles. 相似文献
19.
A procedure focused on microwave-assisted extraction in open vessel (MAE-OV) and gas chromatography with electron capture detection (GC-ECD) was used for the determination of 26 congeners of polychlorinated biphenyls (PCBs) in soil samples. The limit of detection (LOD) and limit of quantification (LOQ) were evaluated for commercial PCBs mixture Aroclor1260. LOD and LOQ were calculated for each PCB congener, in the ranges (0.03–0.27?ng?g?1) and (0.11–0.70?ng?g?1), respectively. After optimization, 26 PCBs congeners were successfully extracted from soil samples with recovery amounts ranging between 84.7% and 117.3% for all PCBs congeners. The evaluated method of MAE-OV showed good separation and extraction of all PCBs congeners from soil samples. Extraction parameters such as solvent choice, power and extraction time were investigated. This study indicated that MAE-OV could be an interesting alternative method to extract PCBs from soils, since it is economical, easy, fast and requires low amounts of solvents. 相似文献
20.
Takamitsu Otake Masahiko Numata Akiko Takatsu 《International journal of environmental analytical chemistry》2016,96(14):1378-1388
Human serum certified reference material (CRM), NMIJ CRM 7407-a, for the analysis of polychlorinated biphenyls (PCBs) was developed by the National Metrology Institute of Japan. A pool of commercially available human serum was used as a raw material of the CRM. This sample is in the form of a liquid comprising approximately 4 g stored in a cryogenic polypropylene vial. Homogeneity assessment was performed, and the material was homogeneous enough for PCB 118, PCB 138, PCB 153, and PCB 194: the relative uncertainties due to inhomogeneity were 2.5–10.5%. The results obtained from the stability assessment indicated that the target PCBs were stable: the relative uncertainties due to instability were 0–14.7%. The certification was carried out using two different types of GC columns for each target PCB to avoid interferences on GC separation; the certified values of the target PCBs (PCB 118, PCB 138, PCB 153, and PCB 194) were 9.7–129.8 ng/kg. This is the first frozen human serum CRM in which PCBs were determined by isotope dilution mass spectrometry. 相似文献