首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A rapid, selective, and sensitive ultra‐high performance liquid chromatography‐tandem mass spectrometry method was developed for simultaneous determination of ferulic acid, paeoniflorin, and albiflorin, the major active constituents of Danggui‐Shaoyao‐San, in rat plasma using geniposide as the internal standard. The plasma samples were processed by protein precipitation with acetonitrile, and then separated on a Shim‐Pack XR‐ODS C18 column (75 mm × 3.0 mm, 2.2 μm) using gradient elution program with a mobile phase consisting of 0.1% aqueous formic acid and acetonitrile at a flow rate of 0.4 mL/min. The detection was achieved on a 3200 QTRAP mass spectrometer equipped with electrospray ionization source in negative ionization mode. Quantification was performed using multiple reaction monitoring mode by monitoring the fragmentation of m/z 192.9→134.0 for ferulic acid, m/z 525.0→120.9 for paeoniflorin, m/z 525.2→121.0 for albiflorin, and m/z 433.1→225.1 for the internal standard, respectively. The calibration curve was linear in the range of 5–2500 ng/mL for all the three analytes (r ≥ 0.9972) with the lower limit of quantitation of 5 ng/mL. The intraday and interday precisions were below 12.1% for all the analytes in terms of relative standard deviation, and the accuracy was within ±11.5% in terms of relative error. The extraction recovery, matrix effect and stability were satisfactory in rat plasma. The validated method was successfully applied to a pharmacokinetic study of ferulic acid, paeoniflorin, and albiflorin after oral administration of Danggui‐Shaoyao‐San to rats.  相似文献   

2.
LC‐ ESI‐ MS/MS simultaneous bioanalytical method was developed to determine acitretin and its metabolite isoacitretin in human plasma using acitretin‐d3 used as the internal standard for both analytes. The compounds were extracted using protein precipitation coupled with liquid–liquid extraction with flash freezing technique. Negative mass transitions (m/z) of acitretin, isoacitretin and acitretin‐d3 were detected in multiple reactions monitoring (MRM) mode at 325.4 → 266.3, 325.2 → 266.1 and 328.3 → 266.3, respectively, with a turbo ion spray interface. The chromatographic separation was achieved on an Ascentis‐RP amide column (4.6 × 150 mm, 5 µm) with mobile phase delivered in isocratic mode. The method was validated over a concentration range of 1.025–753.217 ng/mL for acitretin and 0.394–289.234 ng/mL for isoacitretin with a limit of quantification of 1.025 and 0.394 ng/mL. The intra‐day and inter‐day precisions were below 8.1% for acitretin and below 13.8% for isoacitretin, while accuracy was within ±7.0 and ±10.6% respectively. For the first time, the best possible conditions for plasma stability of acitretin and isoacitretin are presented and discussed with application to clinical samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
Ginsenoside Rh3 (GRh3) is a bacterial metabolite of ginsenoside Rg5, which is the main component of hot-processed ginseng. A simple, efficient and sensitive method was developed and validated for the determination of GRh3 in rat plasma by LC–tandem mass spectrometry. After protein precipitation with methanol/acetonitrile (1:1, vol/vol) using propranolol as the internal standard, the target analytes were separated on an XDB C18 column, with methanol containing 0.1% formic acid and water containing 0.1% formic acid used as mobile phases for gradient elution. Mass spectrometry was performed in electrospray ion source–positive ion mode and multiple reaction monitoring mode, monitoring the transitions m/z 622.5 → 425.5 and m/z 260.1 → 116.1 for GRh3 and internal standard, respectively. The concentration range of GRh3 was 20–20,000 ng/mL and the correlation coefficient (r2) was greater than 0.99. The accuracy error and relative standard deviation were below 15%. The extraction recovery and matrix effect were 74.2% to 78.7% and 96.9% to 108.4%, respectively. Under different conditions, GRh3 was stable in the range of 1.8%–8.7%. This method has been successfully applied to study the pharmacokinetics of GRh3 with an oral dose of 10.0 mg/kg and an intravenous dose of 2.0 mg/kg in rats, respectively. The absolute bioavailability of GRh3 was 37.6%.  相似文献   

4.
We developed and validated a simple, sensitive, selective, and reliable LC–MS/MS–ESI method for the direct quantitation of lumefantrine (LFN) enantiomers [(−)-LFN and (+)-LFN] in mice plasma as per regulatory guideline. LFN enantiomers and carbamazepine (internal standard) were extracted from mice plasma using Strata X SPE (solid-phase extraction) cartridges. Good resolution between enantiomers was achieved on a Chiralpak IA-3 column using an isocratic mobile phase (0.1% of diethyl amine in methanol), which was delivered at a flow rate of 0.8 mL/min. Detection and quantitation were performed using multiple reaction monitoring mode following the transitions m/z 530.27 → 512.30 and 237.00 → 194.00 for LFN enantiomers and the internal standard, respectively, in the positive-ionization mode. The proposed method provided accurate and reproducible results over the linearity range of 2.39–895 ng/mL for each enantiomer. The intra- and inter-day precisions were in the range of 1.03–6.14 and 6.36–8.70 and 2.03–4.88 and 5.82–11.5 for (−)-LFN and (+)-LFN, respectively. Both (−)-LFN and (+)-LFN were found to be stable under different stability conditions. The method was successfully used to delineate stereoselective pharmacokinetics of LFN enantiomers in mice after an oral administration of rac-LFN (20 mg/kg). The pharmacokinetic results indicated that the disposition of LFN enantiomers was stereoselective in mice.  相似文献   

5.
We developed and validated a semi‐automated LC/LC‐MS/MS assay for the quantification of imatinib in human whole blood and leukemia cells. After protein precipitation, samples were injected into the HPLC system and trapped onto the enrichment column (flow 5 mL/min); extracts were back‐flushed onto the analytical column. Ion transitions [M + H]+ of imatinib (m/z = 494.3 → 394.3) and its internal standard trazodone (372.5 → 176.3) were monitored. The range of reliable response was 0.03–75 ng/mL. The inter‐day precisions were: 8.4% (0.03 ng/mL), 7.2% (0.1 ng/mL), 6.5% (1 ng/mL), 8.2% (10 ng/mL) and 4.3% (75 ng/mL) with no interference from ion suppression. Autosampler stability was 24 hs and samples were stable over three freeze–thaw cycles. This semi‐automated method is simple with only one manual step, uses a commercially available internal standard, and has proven to be robust in larger studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
A highly sensitive, specific and enantioselective assay has been validated for the quantitation of OTX015 enantiomers [(+)‐OTX015 and (−)‐OTX015] in mice plasma on LC–MS/MS‐electrospray ionization as per regulatory guidelines. Protein precipitation was used to extract (±)‐OTX015 enantiomers and internal standard (IS) from mice plasma. The active [(−)‐OTX015] and inactive [(+)‐OTX015] enantiomers were resolved on a Chiralpak‐IA column using an isocratic mobile phase (0.2% ammonia/acetonitrile 20 : 80, v /v) at a flow rate of 1.2 mL/min. The total run time was 6.0 min. (+)‐OTX015, (−)‐OTX015 and IS eluted at 3.34, 4.08 and 4.77 min, respectively. The MS/MS ion transitions monitored were m/z 492 → 383 for OTX015 and m/z 457 → 401 for IS. The standard curves for OTX015 enantiomers were linear (r 2 > 0.998) in the concentration range 1.03–1030 ng/mL. The inter‐ and intraday precisions were in the range 2.20–13.3 and 8.03–12.1% and 3.80–14.4 and 8.97–13.6% for (+)‐OTX015 and (−)‐OTX015, respectively. Both the enantiomers were found to be stable in a battery of stability studies. This novel method has been applied to the study of stereoselective oral pharmacokinetics of (−)‐OTX015 and unequivocally demonstrated that (−)‐OTX015 does not undergo chiral inversion to its antipode in vivo in mice.  相似文献   

7.
A sensitive and rapid LC–MS/MS method was developed and validated for quantitation of sciadopitysin in rat plasma using amentoflavone as an internal standard. Sample processing was accomplished after deproteinization with 150 μL aliquot of acetonitrile. Chromatographic separation was achieved using an Agela C18 column with an isocratic mobile phase comprising 2 mm ammonium acetate–acetonitrile (35:65, v/v) at a flow rate of 0.4 mL/min. Detection was performed by selection reaction monitoring on a triple‐quadrupole mass spectrometer following the transitions m/z 579 → 547 and 537 → 375 for sciadopitysin and internal standard, respectively, in the negative ionization mode. The calibration curve was linear from 2.90 to 1160 ng/mL for sciadopitysin. Intra‐ and inter‐day precisions were in the ranges 4.1–11.4 and 5.7–9.1% for sciadopitysin. Sciadopitysin was stable under different stability conditions. The validated assay was applied to pharmacokinetic and bioavailability studies in rats.  相似文献   

8.
Cinnarizine is a weak base, which can produce supersaturation and precipitation during gastrointestinal transit, affecting its absorption in vivo. Therefore, it is necessary to investigate whether the oral bioavailability of cinnarizine can be improved after co-administration with precipitation inhibitors or not. In order to evaluate the pharmacokinetic behavior of cinnarizine in rats, a simple, rapid, sensitive, and environmentally friendly supercritical fluid chromatography-tandem mass spectrometric method was established and validated. In this method, flunarizine, a structural analogue of cinnarizine, was selected as the internal standard, and cinnarizine was extracted from rat plasma using evaporation-free liquid–liquid extraction method. The analytes were separated on a Torus 1-AA column (3.0 mm × 100 mm, 1.7 μm) within 2.0 min, using a gradient elution procedure. The transitions of cinnarizine and flunarizine were m/z 369.1 → 167.1 and m/z 405.1 → 203.1, respectively. Cinnarizine showed good linear correlation in the range of 1–500 ng/ml with a lower limit of quantification of 1 ng/ml. The intra- and interday precision and accuracy of all quality control samples were within ±15%. This high-throughput, accurate, sensitive, and reproducible method has been successfully applied to study the effects of the precipitation inhibitor cinnarizine on the pharmacokinetics in rats.  相似文献   

9.
Pantoprazole, a proton pump inhibitor, is clinically used for the treatment of peptic diseases. An enantioselective LC‐MS/MS method was developed and validated for the simultaneous determination of pantoprazole enantiomers in human plasma. Pantoprazole enantiomers and the internal standard were extracted from plasma using acetonitrile. Chiral separation was carried on a Chiralpak IE column using the mobile phase consisted of 10 mm ammonium acetate solution containing 0.1% acetic acid–acetonitrile (28 : 72, v /v). MS analysis was performed on an API 4000 mass spectrometer. Multiple reactions monitoring transitions of m /z 384.1→200.1 and 390.1→206.0 were used to quantify pantoprazole enantiomers and internal standard, respectively. For each enantiomer, no apparent matrix effect was found, the calibration curve was linear over 5.00–10,000 ng/mL, the intra‐ and inter‐day precisions were below 10.0%, and the accuracy was within the range of –5.6% to 0.6%. This method was applied to the stereoselective pharmacokinetic studies in human after intravenous administration of S ‐(–)‐pantoprazole sodium injections. No chiral inversion was observed during sample storage, preparation procedure and analysis. While R ‐(+)‐pantoprazole was detected in human plasma with a slightly high concentration, which implied that S ‐(–)‐pantoprazole may convert to R ‐(+)‐pantoprazole in some subjects.  相似文献   

10.
An ultra‐performance liquid chromatography with tandem mass spectrometry (UPLC–MS/MS) method was developed and validated to concurrently determine rhynchophylline and hirsutine in rat plasma. The sample preparation of rat plasma was achieved by alkalization and liquid–liquid extraction. The mass transition of precursor ion → product ion pairs were monitored at m/z 385.2 → 160.0 for rhynchophylline, m/z 369.3 → 144.0 for hirsutine and m/z 414.0 → 220.0 for noscapine (internal standard). This method revealed linear relationships from 2.5 to 50 ng/mL (r2 > 0.997) for rhynchophylline and from 2.5 to 50 ng/mL (r2 > 0.998) for hirsutine. The limit of quantification values for rhynchophylline and hirsutine in rat plasma were both 2.5 ng/mL. Intra‐day and inter‐day precisions were within 10.6% and 12.5%, respectively, for rhynchophylline and hirsutine, and the accuracy (bias) was <10%. Liquid–liquid extraction of rat plasma samples resulted in insignificant matrix effect, and the extraction recoveries were >83.6% for rhynchophylline, 73.4% for hirsutine and 90.7% for the internal standard. This method was applied successfully to a pharmacokinetic study of rhynchophylline and hirsutine in rats after oral administration. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
We developed and validated a simple, sensitive, selective and reliable LC–ESI‐MS/MS method for direct quantitation of dropropizine enantiomers namely levodropropizine (LDP) and dextrodropropizine (DDP) in rat plasma without the need for derivatization as per regulatory guidelines. Dropropizine enantiomers and carbamazepine (internal standard) were extracted from 50 μL rat plasma using ethyl acetate. LDP and DDP resolved with good baseline separation (Rs = 4.45) on a Chiralpak IG‐3 column. The mobile phase consisted of methanol with 0.05% diethylamine pumped at a flow rate of 0.5 mL/min. Detection and quantitation were done in multiple reaction monitoring mode following the transitions m/z 237 → 160 and 237 → 194 for dropropizine enantiomers and the internal standard, respectively, in the positive ionization mode. The proposed method provided accurate and reproducible results over the linearity range of 3.23–2022 ng/mL for each enantiomer. The intra‐ and inter‐day precisions were in the ranges of 3.38–13.6 and 5.11–13.8 for LDP and 4.19–11.8 and 8.89–10.1 for DDP. Both LDP and DDP were found to be stable under different stability conditions. The method was successfully used in a stereoselective pharmacokinetic study of dropropizine enantiomers in rats following oral administration of racemate dropropizine at 100 mg/kg. The pharmacokinetic results indicate that the disposition of dropropizine enantiomers is not stereoselective and chiral inversion does not occur in rats.  相似文献   

12.
The angiotensin converting enzyme‐inhibitor enalapril is the prodrug of enalaprilat and used in the treatment pediatric hypertension and chronic heart failure. Pharmacokinetic data are lacking to provide adequate dosing and for pediatric pharmacotherapeutical trials it is imperative to minimize sample volume. Therefore an HPLC‐tandem mass spectrometry (MS) method for the determination of enalapril and enalaprilat in 100 μL of human serum was developed and validated with benazepril as internal standard (IS). After solid‐phase extraction, chromatography was performed on a Luna® RP‐C18(2) column with methanol–water–formic acid (65:35:1, v/v/v) as mobile phase and a flow rate of 0.4 mL/min. The MS was set to positive‐mode electrospray ionization and multiple reaction monitoring, analyzing the m/z transitions channels 377.3 → 234.2, 349.3 → 206.1 and 425.3 → 351.2 for enalapril, enalaprilat and IS. Calibration curves were linear in the range of 1.61–206 ng/mL (enalapril) and 1.84–236 ng/mL (enalaprilat) with coefficients of determination >0.99. Relative standard deviations of intra‐ and inter‐run precisions were below 7% and relative errors were below 6 ± 7% for both analytes. Also stabilities were acceptable for both analytes. As an application example, concentrations of enalapril and enalaprilat in serum after oral administration of 20 mg enalapril maleat in a healthy volunteer were determined. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

13.
A rapid and sensitive LC–MS/MS method was developed and validated for the simultaneous determination of nicotinamide and its metabolite N1-methylnicotinamide in human serum. Serum samples were prepared by protein precipitation with acetonitrile. The chromatographic separation was performed on a Waters Spherisorb S5 CN microbore column (2.0 × 100 mm, 5 μm) with gradient elution within 7 min. Acetonitrile and 5 mm ammonium formate aqueous solution (containing 0.1% formic acid) were used as mobile phases. Nicotinamide, N1-methylnicotinamide and N′-methylnicotinamide (internal standard) were detected with a triple-quadrupole tandem mass spectrometer in the positive ion mode. Multiple reaction monitoring was used to monitor precursor to product ion transitions of m/z 123.1 → 80.1 for nicotinamide, m/z 137.1 → 94.1 for N1-methylnicotinamide and m/z 137.1 → 80.1 for the internal standard. The linear ranges of nicotinamide and N1-methylnicotinamide were 5.000–160.0 and 2.500–80.00 ng/ml, respectively. The intra- and inter-day precisions (RSD) of both analytes were within 6.90%. The recoveries were >88%. The analytes were proven to be stable during all sample storage, preparation and analytic procedures. The method was successfully applied to determine the concentrations of nicotinamide and N1-methylnicotinamide in human serum to investigate the association between their concentrations and obesity in 1160 Chinese subjects.  相似文献   

14.
A sensitive ultra-high performance liquid chromatography–tandem mass spectrometry (UHPLC–MS/MS) method was established to analyze furanodienone in rat plasma. In the process of chromatographic separation, selected reaction monitoring transitions for furanodienone and patchouli alcohol (internal standard, IS) were m/z 231.1 → 83.2 and m/z 205.1 → 95.1, respectively. Great linearity of furanodienone in plasma samples was found in the corresponding concentration range (r > 0.995). Intra- and inter-day precisions (RSD, %) were <11.3% in plasma, and the accuracy (RE, %) was within ±10.7%. This method was used to the furanodienone study on rat pharmacokinetics after a single oral dose of 10 mg/kg of furanodiene. The results indicated that the maximum observed plasma concentration was 52.4 ± 19.1 ng/ml at 1.2 ± 0.7 h with an elimination half-life of 2.2 ± 0.7 h. The obtained data indicated that furanodienone could be moderately distributed and eliminated.  相似文献   

15.
Retrorsine (RTS) is a toxic retronecine-type pyrrolizidine alkaloid, which is widely distributed. The purpose of this study was to develop a high-performance liquid chromatography–tandem mass spectrometric (LC–MS/MS) method for serum RTS determination in mice. Serum samples were deproteinated by acetonitrile, separated on a C18-PFP column and delivered at 0.8 ml/min with an eluting system composed of water containing 0.1% (v/v) formic acid and acetonitrile containing 0.1% (v/v) formic acid as mobile phases. RTS and the internal standard S-hexylglutathione (H-GSH) were quantitatively monitored with precursor-to-product transitions of m/z 352.1 → 120.1 and m/z 392.2 → 246.3, respectively. The method showed excellent linearity over the concentration range 0.05–50 μg/ml, with correlation coefficient r2 = 0.9992. The extraction recovery was >86.34%, and the matrix effect was not significant. Inter- and intra-day precisions (RSD) were <4.99%. The validated LC–MS/MS method was successfully applied to study the toxicokinetic profiles of serum RTS in mice after intravenous, oral administration and co-treated with ketoconazole, which showed that RTS displayed a long half-life (~11.05 h) and good bioavailability (81.80%). Co-administration of ketoconazole (KTZ) increased the peak serum concentration and area under the concentration–time curve and decreased the clearance and mean residence time. Summing up, a new standardized method was established for quantitative determination of RTS in sera.  相似文献   

16.
《Analytical letters》2012,45(15):2424-2431
A sensitive LC-ESI-MS/MS method for determination of chlorzoxazone in rat plasma has been developed. Chromatographic separation was achieved on a Zorbax SB-C18 column, with 45:55 (v/v) acetonitrile–water as the mobile phase. A LC-ESI-MS/MS was performed in a multiple reactions monitoring (MRM) mode using target ions m/z 167.5→131.6 for chlorzoxazone and m/z 230.7→185.6 for phenobarbital (internal standard). The calibration plots were linear over the range of 10.0–2,000 ng/mL. Intra-day and inter-day precisions were better than 5.1% and 6.8%, respectively. The validated method was successfully used to analyze the drug in samples of rat plasma for pharmacokinetic study.  相似文献   

17.
A robust and sensitive high‐performance liquid chromatographic–tandem mass spectrometric (HPLC‐MS/MS) assay for the high‐throughput quantification of the antihypertensive drug azelnidipine in human plasma was developed and validated following bioanalytical validation guidelines. Azelnidipine and internal standard (IS), telmisartan, were extracted from human plasma by precipitation protein and separated on a C18 column using acetonitrile–methanol–ammonium formate with 0.1% formic acid as mobile phase. Detection was performed on a turbo‐spray ionization source (ESI) and mass spectrometric positive multiple reaction monitoring mode (+MRM) using the respective transitions m/z 583.3 → 167.2 for azelnidipine and m/z 515.3 → 497.2 for IS. The method has a wide analytical measuring range from 0.0125 to 25 ng/mL. For the lowest limit of quantitation, low, medium and high quality controls, intra‐ and interassay precisions (relative standard deviation) were 3.30–7.01% and 1.78–8.09%, respectively. The drug was sufficiently stable under all relevant analytical conditions. The main metabolite of azelnidipine, M‐1 (aromatized form), was monitored semiquantitatively using the typical transition m/z 581.3 → 167.2. Finally, the method was successfully applied to a clinical pharmacokinetic study in human after a single oral administration of azelnidipine 8 mg. The assay meets criteria for the analysis of samples from large research trials. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
A simple, practical, accurate and sensitive liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method was developed and fully validated for the quantitation of guanfacine in beagle dog plasma. After protein precipitation by acetonitrile, the analytes were separated on a C18 chromatographic column by methanol and water containing 0.1% (v/v) formic acid with a gradient elution. The subsequent detection utilized a mass spectrometry under positive ion mode with multiple reaction monitoring of guanfacine and enalaprilat (internal standard) at m/z 246.2 → 159.0 and m/z 349.2 → 205.9, respectively. Good linearity was obtained over the concentration range of 0.1–20 ng/mL for guanfacine in dog plasma and the lower limit of quantification of this method was 0.1 ng/mL. The intra‐ and inter‐day precisions were <10.8% relative standard deviation with an accuracy of 92.9–108.4%. The matrix effects ranged from 89.4 to 100.7% and extraction recoveries were >90%. Stability studies showed that both analytes were stable during sample preparation and analysis. The established method was successfully applied to an in vivo pharmacokinetic study in beagle dogs after a single oral dose of 4 mg guanfacine extended‐release tablets. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

19.
A simple, selective and reliable LC‐MS/MS method was validated for simultaneous quantitation of darolutamide diastereomers in 50 μL mouse plasma using warfarin as an internal standard (IS) as per regulatory guidelines. Plasma samples were extracted by liquid–liquid extraction and the chromatographic separation was achieved on a Chiralpak IA column with an isocratic mobile phase 5 mm ammonium acetate–absolute alcohol (20:80, v/v) at a flow rate of 1.0 mL/min. Detection and quantitation was done in multiple reaction monitoring mode following the transitions m/z 397 → 202 and 307 → 250 for darolutamide diastereomers and the IS, respectively, in the negative ionization mode. The linearity range was 100–2400 ng/mL for each diastereomer. The intra‐ and inter‐day precisions were in the ranges of 1.78–4.20 and 4.34–14.6, and 3.63–4.74 and 4.78–5.15 for diastereomer‐1 and diastereomer‐2, respectively. Both diastereomers were found to be stable under different stability conditions. The validated method was applied to a pharmacokinetic study in mice. Following oral administration of darolutamide at 10 mg/kg, maximum concentration in plasma was 4189 and 726 ng/mL for diastereomer‐1 and diastereomer‐2, respectively. The terminal half‐life was found to be ~0.50 h for both the diastereomers. The AUC(0–t) was found to be 18,961 ng*h/mL for diastereomer‐1 and 1340 ng*h/mL diastereomer‐2.  相似文献   

20.
This study aimed to develop and validate a simple and sensitive ultra high performance liquid chromatography tandem mass spectrometry method for the simultaneous determination of sophoraflavanone G and kurarinone in rat plasma by using rutin as the internal standard. Then, the developed method was applied to investigate the pharmacokinetics of sophoraflavanone G and kurarinone in rats after dosing the flavonoid extract from Sophora flavescens. Plasma samples were processed using a liquid–liquid extraction procedure with ethyl acetate. The analysis was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring with an electrospray ionization source in negative ionization mode. Quantitative ion transitions of m/z 423.2→161.2, 437.2→161.1, and 609.3→300.3 were monitored for sophoraflavanone G, kurarinone, and rutin, respectively. The calibration curves of the two analytes exhibited good linearity (r2>0.9923) over the range of 0.1–200 ng/mL for sophoraflavanone G and 0.1–1000 ng/mL for kurarinone. Relative standard deviations were less than 13.2% for the intra‐ and inter‐day precisions and no more than 12.6% for the recovery, showing good precision and satisfactory accuracy of the developed method. The validated method was successfully applied to the pharmacokinetic study of sophoraflavanone G and kurarinone after a single intravenous (25 mg/kg) and oral (500 mg/kg) administration of the flavonoid extract from S. flavescens, and the absolute bioavailability for sophoraflavanone G and kurarinone was about 36 and 17%, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号