首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ng CI  Zhang X 《Talanta》2011,85(4):1766-1771
In this work, an analytical method for GC using direct solid sample introduction was developed to tackle the problem regarding quick detection of pesticide residue in crops and large-scale screening of samples. 10 mg of the crop solid sample without sample pre-treatment was directly introduced into a modified split/splitless injector for GC analysis. A split/splitless injector was modified to quickly remove oxygen and low boiling-point matrices of the sample. The whole sampling procedure was simple and it required less than 5 min. The experimental parameters including injector-port temperature, removal of oxygen and low boiling point matrices, size and the amount of the solid sample, oven temperature program were studied. Satisfactory recoveries of 6 pesticides (methyl parathion, fenitrothion, aldrin, dieldrin, endosulfan, o,p′-DDT) were obtained in maize and rice sample. Relative standard deviation was less than 15%. Experimental results showed that the proposed method was quick and reliable for pesticide residues analysis in crops.  相似文献   

2.
In this work, a vibrating tip spray ionization source was developed for direct mass spectrometric analysis of raw samples under voltage‐free condition. A solid tip was mounted on a vibrator, and the solid tip was placed on the front of MS inlet. Liquid, viscous, and bulk solid samples could be directly loaded on the tip‐end surface, and then a drop of solvent at microliter level was subsequently loaded on the tip for dissolution and extraction of analytes, and a vibrator was then started to atomize and ionize the analytes under ambient condition. We demonstrated vibrating tip spray mass spectrometry in various applications, including food safety, pharmaceutical analysis, and forensic science. Furthermore, in situ analysis of biological tissues and in vivo analysis of living plants were conveniently performed, due to voltage‐free. Different vibration frequencies and solvent compositions were investigated. The analytical performances, including sensitivity, reproducibility, and linear range, were investigated. The ionization process and mechanism were also discussed in this work.  相似文献   

3.
Ginsenosides are regarded as the main active, non-volatile components of Panax ginseng (C. A. Meyer). However, throughout the long history of ginseng research, there has been virtually no report describing its volatile flavor compounds. A solvent-free procedure for the determination of volatile flavor compounds generated from fresh, white and red Panax ginseng (C. A. Meyer) using solvent-free solid injection (SFSI) coupled with gas chromatography-mass spectrometry (GC-MS) detection is described here. At no point in the SFSI technique were the extraction conditions optimized. Rather, the experimental variables including various sample preparations (fresh, oven-dried and freeze-dried), injector temperatures (100, 150, 200, 250 and 300 degrees C), and preheating times (3, 5, 7, 10 and 15 min), were predicated on the experience of the authors. A total of 47 compounds were identified in various forms of ginseng. Among the compounds identified in the sample, fresh ginseng was characterized by a high proportion of 3-acetyl-1-(3,4-dimethoxyphenyl)-5-ethyl-4,5-dihydro-7,8-dimethoxy-4-methylene-3H-2,3-benzodiazepine (64.24%) and 23,24-dinor-3-oxolean-4,12-dien-28-oic acid (21.42%); 2-furanmethanol (20.26%) and 3-hydroxy-2-methyl-4H-pyran-4-one (17.95%) were detected as the major components in white ginseng while the main components of the red ginseng were found to be 1,2-benzenedicarboxylic acid dibutyl ester (16.27%) and 2-furanmethanol (13.82%). SFSI is a solvent-free, rapid and simple sample preparation technique based on direct vaporization. There is no dilution or contamination with solvent or its impurities and no loss of quickly eluted components was observed in the solvent peak.  相似文献   

4.
A new method for the direct analysis of coal using electrothermal vaporization inductively coupled plasma mass spectrometry and direct solid sample analysis was developed, aiming at the determination of Br and Cl. The procedure does not require any significant sample pretreatment and allows simultaneous determination of both elements to be carried out, requiring small mass aliquots of sample (about 0.5 mg). All operating parameters, including carrier gas flow-rate and RF power, were optimized for maximum sensitivity. The use of modifiers/aerosol carriers (Pd, Pd + Al and Pd + Ca) was evaluated, and the mixture of Pd and Ca was chosen, allowing pyrolysis and vaporization temperatures of 700 °C and 1900 °C, respectively. Chlorine was accurately determined using calibration against solid standards, whereas Br could also be determined using calibration against aqueous standard solutions. The limits of quantification were 0.03 μg g−1 for Br and 7 μg g−1 for Cl, and no spectral interferences were observed.  相似文献   

5.
In this work, a new capillary electrophoresis-mass spectrometry (CE-MS) procedure is developed to analyze proteins in Spirulina platensis microalgae. It is demonstrated that a fine optimization of several separation parameters is essential in order to achieve suitable CE-MS analysis of these proteins in natural extracts from microalgae. Namely, optimization of the composition of the separation buffer, electrospray conditions, and washing routine between runs are required in order to obtain reliable and reproducible CE-MS analyses of the main proteins found in this microalga (namely, allophycocyanin-alpha chain, allophycocyanin-beta, c-phycocyanin-alpha, and c-phycocyanin-beta). The relative molecular mass of these biopolymers is determined using two different MS instruments coupled to CE, i.e., CE-ion trap-MS and CE-time of flight-MS (CE-TOF-MS). A comparison between the results obtained with both instruments is carried out. The high resolution of the TOF-MS enables the distinction of small modifications in proteins and, thus, a more accurate mass determination. Interestingly, molecular mass values obtained by both CE-MS procedures agree very well while these experimental values are only in partial agreement with those theoretically expected (i.e., genetically derived masses). Some protein modifications due to amino acids exchange induced by nucleotide codon mutations are proposed to explain this difference.  相似文献   

6.
王平利  陈彦龙  胡玉玲  李攻科 《色谱》2021,39(2):162-172
食品安全关系身体健康和生命安全,是全球关注的热点之一。食品基质复杂,痕量有毒有害物质分析之前必须经过有效的前处理。目前发展的前处理技术如固相萃取、磁固相萃取、固相微萃取等,其关键是吸附介质。共价有机聚合物是一类通过共价键连接而成的有机多孔材料,具有质轻、稳定性好、比表面积大、结构可控、易于修饰等特性,是一类优异的新型吸附材料。该文综述了近年来共价有机聚合物(COPs)在食品安全分析前处理中的应用进展。共价有机聚合物及其功能化复合材料通过简单的装填、聚合反应或化学键合固定到小柱或毛细管柱中用作固相萃取的吸附介质;通过一锅法、原位还原法、原位生长法或共沉淀法生成具有磁性的固相萃取吸附介质;或者通过物理涂覆、化学键合、溶胶凝胶法及原位生长法制备固相微萃取纤维。基于以上高吸附容量共价有机聚合物的样品前处理技术,食品中农残兽残、添加剂、环境污染物及生物毒素等得到了有效富集。最后,展望了COPs在食品分析样品前处理应用中的发展方向:简单高效绿色制备方法的开发,功能化COPs的设计合成;萃取机理的研究;高通量、高灵敏度分析方法研究。这些研究将促进COPs在样品前处理领域获得更广泛的应用。  相似文献   

7.
赵娜  梁嘉诚  时丽艳  吕运开  于丽青 《色谱》2019,37(3):313-318
分析检测有机肥料中的兽药残留对于评价土壤微生物群落和人类健康的潜在风险至关重要。该文建立了一种QuEChERS联用高效液相色谱-串联质谱(HPLC-MS/MS)同时检测有机肥料中10种氟喹诺酮类药物残留的分析方法。样品经乙二胺四乙酸二钠(Na2EDTA)-Mcllvaine缓冲溶液(pH=4.0)和乙腈提取,采用Atlantis T3 C18色谱柱(250 mm×4.6 mm,5 μm),以0.2%(体积分数)甲酸水溶液和乙腈为梯度洗脱的流动相,采用电喷雾离子(ESI)源,在多反应监测(MRM)扫描模式下进行检测。10种氟喹诺酮类药物用内标法定量。结果表明,10种氟喹诺酮类药物在10~500 μg/kg范围内线性关系良好,相关系数均大于0.9930。方法检出限为0.5~2.5 μg/kg,定量限为1.7~8.3 μg/kg。该分析方法成功应用于9个有机肥样品的兽药污染调查。结果显示,样品的平均加标回收率为82.5%~117.1%,相对标准偏差为3.4%~10.2%。该方法准确可靠、灵敏度高,能够满足多种兽药残留的同时检测,该方法有望为有机肥料兽药风险评估提供依据。  相似文献   

8.
陈婷  续艳丽  张文  闫君  彭涛 《色谱》2019,37(9):1019-1025
建立了全自动QuEChERS样品制备系统结合高效液相色谱-串联质谱(HPLC-MS/MS)同时检测植物源性食品中34种农药残留的分析方法。方法利用全自动QuEChERS样品制备系统涡旋振动和离心功能,将手动QuEChERS方法中样品提取和分散固相萃取相结合;优化了操作参数及前处理步骤,在多反应监测(MRM)模式下检测,基质匹配外标法定量。从方法学验证角度对全自动QuEChERS法与手动QuEChERS法进行了比较。结果表明:该方法中大多数农药在一定范围内呈现良好的线性关系,相关系数(R2)均大于0.99,检出限为0.76~3.60 μg/kg,定量限为2.28~10.80 μg/kg,加标回收率为53.0%~125.2%,相对标准偏差(RSD)<15.9%(n=5)。该方法与手动QuEChERS法的方法验证比对结果显示差异不明显,用于植物源性食品中多农药残留检测可有效降低劳动强度和出错概率。  相似文献   

9.
The non‐stick properties of parchment papers are achieved by polydimethylsiloxane (PDMS) coatings. During baking, PDMS can thus be extracted from the silicone‐coated parchment into the baked goods. Positive‐ion direct analysis in real time (DART) mass spectrometry (MS) is highly efficient for the analysis of PDMS. A DART‐SVP source was coupled to a quadrupole‐time‐of‐flight mass spectrometer to detect PDMS on the contact surface of baked goods after use of silicone‐coated parchment papers. DART spectra from the bottom surface of baked cookies and pizzas exhibited signals because of PDMS ions of the general formula [(C2H6SiO)n + NH4]+ in the m/z 800–1900 range. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
A temperature-programmed desorption (TPD) device connected to a mass spectrometer was used to detect volatile organic compounds from air samples. The main aim was to develop an analytical method, by which both non-polar and polar organic components can be detected in the same run. In TPD, the adsorbed compounds are desorbed from the resin more slowly than in the conventional trapping techniques, such as purge-and-trap technique, in which the resin is flash-heated and the compounds are desorbed at the same time to a cryogenic trap or an analytical column. In TPD, the adsorbent resin acts also as an analytical column. In this way it is possible to obtain more rapid analysis, and also a more simple instrumentation, which can be used on-line and on-site. In this work, a new version of TPD device, which uses a resistor for heating and a Peltier element for rapid cooling, was designed and constructed. Various adsorbent resins were tested for their adsorption and desorption properties of both polar and non-polar compounds. When using a mixture of adsorbent resins, Tenax TA and HayeSep D, it was possible to analyze both polar, low-molecular weight compounds, such as methanol and ethanol, and non-polar volatile organic compounds, such as benzene and toluene, in the same run within 15 min including sampling. The same TPD principle was also tested using a Fourier transform infrared spectrometer as an analytical instrument, and the results showed that it was possible to obtain a separation of similar compounds, such as hexane and heptane, and still retaining the same sensitivity as the original on-line FTIR instrument.  相似文献   

11.
孙慧婧  李佩纹  张蓓蓓  陈慧敏 《色谱》2022,40(4):333-342
抗生素作为新型有机污染物在自然水体中被频繁检出,检出种类多且含量水平低,为了实现更加快速、全面、准确的高通量分析,研究开发了一种利用大体积直接进样测定水中7大类(磺胺类、林可酰胺类、喹诺酮类、大环内酯类、四环素类、头孢类及氯霉素类)42种抗生素的超高效液相色谱-三重四极杆质谱法.水样经0.22μm滤膜过滤,加入Na2E...  相似文献   

12.
Well‐designed metal organic materials (MOMs) were synthesized and applied for pre‐concentration and determination of sodium valproate (Na‐VP) from biological samples, bound to the copper complex of 1,4‐phenylenedioxydiacetic acid under mild conditions. The channels of this sorbent provide high efficiency and also selectivity. The MOMs were structurally characterized using Fourier transform infrared and energy‐dispersive X‐ray spectroscopies, scanning electron microscopy and X‐ray diffraction, and they were found to have suitable features for quantification of Na‐VP using HPLC coupled with UV detection at λ = 215 nm. Moreover, the rate of adsorption is improved by ultrasonic power and the experimental data are best fitted according to Freundlich adsorption isotherm. According to the central composite design, the best experimental conditions are 280.0 μl, 3.0 min and 17.0 mg for volume of eluent, sonication time and sorbent mass respectively. Calibration plots show linear responses towards Na‐VP concentrations (0.4–18.0 μg ml?1), satisfactory limit of detection (0.06 μg ml?1, S/N = 3) and reasonable enrichment factor (70.58). The coefficient of variation values of both inter‐ and intra‐day analyses were less than 4.0%, indicating a candidate method for the determination of Na‐VP in human plasma with reasonable recovery and efficiency.  相似文献   

13.
Quantification of the composition of binary mixtures in secondary ion mass spectrometry (SIMS) is required in the analyses of technological materials from organic electronics to drug delivery systems. In some instances, it is found that there is a linear dependence between the composition, expressed as a ratio of component volumes, and the secondary ion intensities, expressed as a ratio of intensities of ions from each component. However, this ideal relationship fails in the presence of matrix effects and linearity is observed only over small compositional ranges, particularly in the dilute limits. In this paper, we assess an empirical method, which introduces a power law dependence between the intensity ratio and the volume fraction ratio. A previously published physical model of the organic matrix effect is employed to test the limits of the method and a mixed system of 3,3′-bis(9-carbazolyl) biphenyl and tris(2-phenylpyridinato)iridium (III) is used to demonstrate the method. This paper introduces a two-point calibration, which determines both the exponent in the power law and the sensitivity factor for the conversion of ion intensity ratio into volume fraction ratio. We demonstrate that this provides significantly improved accuracy, compared with a one-point calibration, over a wide compositional range in SIMS quantification and with a weak dependence on matrix effects. Because the method enables the use of clearly identifiable secondary ions for quantitative purposes and mitigates commonly observed matrix effects in organic materials, the two-point calibration method could be of significant benefit to SIMS analysts.  相似文献   

14.
New methods have been developed and applied successfully for the determination of dissolved inorganic, organic and total carbon in water samples. The new methods utilize two instrumental setups, Reagent-Free™ Ion Chromatography (RF™-IC) and inductively coupled plasma atomic emission spectrometry (ICP-AES). Dissolved inorganic carbon (DIC) was measured in untreated samples along with Cl, F and SO42− using RF™-IC and by in-line mixing with 0.1 M HNO3 to enhance CO2 removal in the nebulizer, followed by ICP-AES analysis. Total dissolved carbon (TDC) was measured by in-line mixing with 0.1 M NaOH following ICP-AES analysis. Dissolved organic carbon (DOC) was obtained as the difference between DIC and TDC. Only non-volatile organic carbon could be detected by the present method. The workable limits of detection obtained in the present study were 0.5 mM (RF™-IC) and 0.1 mM (ICP-AES) for dissolved inorganic and organic carbon, respectively. The power of the new methods lies in routine analysis of DIC and DOC in samples of natural waters of variable composition and salinity using analytical techniques and facilities available in most laboratories doing water sample analysis. The techniques are sensitive and precise, can be automated using gas-tight sample vials and auto-samplers, and are independent of most elemental interferences with the exception of chloride overload by saline samples when using RF™-IC. The new methods were successfully applied for analysis of DIC and DOC in selected samples of natural and synthetic waters.  相似文献   

15.
A capillary zone electrophoresis (CZE) method with ultraviolet-visible detection has been established and validated for the determination of five phenothiazines: thiazinamium methylsulfate, promazine hydrochloride, chlorpromazine hydrochloride, thioridazine hydrochloride, and promethazine hydrochloride in human urine. Optimum separation was obtained on a 64.5 cm x 75 microm bubble cell capillary using a buffer containing 150 mM tris(hydroxymethyl)aminomethane and 25% acetonitrile at pH 8.2, with temperature and voltage of 25 degrees C and 20 kV, respectively. Naphazoline hydrochloride was used as an internal standard. Field-amplified sample injection (FASI) has been applied to improve the sensitivity of the detection. Considering the influence of parameters affecting the on-line preconcentration (nature of preinjection plug, sample solvent composition, injection times, and injection voltage) and due to the significant interactions among them, in this paper we propose for the first time the application of a multivariate approach to carry out the study. The optimized conditions were as follows: preinjection plug of water for 7 s at 50 mbar, electrokinetic injection for 40 s at 6.2 kV, and 32 microm of H3PO4 in the sample solvent. Also, a solid-phase extraction (SPE) procedure is developed to obtain low detection limits and an adequate selectivity for urine samples. The combination of SPE and FASI-CZE-UV allows adequate linearities and recoveries, low detection limits (from 2 to 5 ng/mL), and satisfactory precisions (3.0-7.2% for an intermediate RSD %).  相似文献   

16.
MIL‐101(Cr) is an excellent metal–organic framework with high surface area and nanoscale cavities, making it promising in solid‐phase extraction. Herein, we used MIL‐101(Cr) as a solid‐phase extraction packing material combined with fast detection of direct analysis in real time mass spectrometry (DART‐MS) for the analysis of triazine herbicides. After systematic optimization of the operation parameters, including the gas temperature of DART, the moving speed of the 1D platform, solvent for desorption, amount of MIL‐101(Cr) extraction time, eluent volume and salt concentration, this method can realize the simultaneous detection of five kinds of triazine herbicides. The limits of detection were 0.1~0.2 ng/mL and the linear ranges covered more than two orders of magnitude with the quantitation limits of 0.5~1 ng/mL. Moreover, the developed method has been applied for the analysis of lake water samples and the recoveries for spiked analytes were in the range of 85~110%. These results showed that solid‐phase extraction with metal–organic frameworks is an efficient sample preparation approach for DART‐MS analysis and could find more applications in environmental analysis.  相似文献   

17.
In the present work, we have characterized in detail the chemical structures of secondary organic aerosol (SOA) components that were generated in a smog chamber and result from the photooxidation of isoprene under high-NO(x) conditions typical for a polluted atmosphere. Isoprene high-NO(x) SOA contains 2-methylglyceric acid (2-MG) and oligoester derivatives thereof. Trimethylsilylation, in combination with capillary gas chromatography (GC)/ion trap mass spectrometry (MS) and detailed interpretation of the MS data, allowed structural characterization the polar oxygenated compounds present in isoprene SOA up to 2-MG trimers. GC separation was achieved between 2-MG linear and branched dimers or trimers, as well as between the 2-MG linear dimer and isomeric mono-acetate derivatives thereof. The electron ionization (EI) spectra of the trimethylsilyl derivatives contain a wealth of structural information, including information about the molecular weight (MW), oligoester linkages, terminal carboxylic and hydroxymethyl groups, and esterification sites. Only part of this information can be achieved with a soft ionization technique such as electrospray (ESI) in combination with collision-induced dissociation (CID). The methane chemical ionization (CI) data were used to obtain supporting MW information. Interesting EI spectral differences were observed between the trimethylsilyl derivatives of 2-MG linear and branched dimers or trimers and between 2-MG linear dimer mono-acetate isomers.  相似文献   

18.
The amount of sample that is available for analysis in laboratory plant cultivation experiments is usually very limited. Highly sensitive analytical techniques are therefore required, even for elements that are present in the plants at mg g–1 concentrations, and graphite furnace atomic absorption spectrometry (GFAAS) was chosen in this work because of its micro-sampling capability, and its relatively simple operation. Four micro-methods were investigated for the determination of iron in roots and leaves of rice plants: i) a micro-digestion with nitric and hydrochloric acids, ii) a slurry procedure using tetramethylammonium hydroxide (TMAH) tissue solubilizer, iii) a slurry prepared in 1.4 mol L–1 nitric acid, and treated in an ultrasonic bath, and iv) the direct analysis of solid samples. The micro-digestion was suffering from high blank values and contamination problems, so that it could not be recommended for routine purposes. The TMAH method exhibited poor precision and occasional low recoveries, particularly for real samples. Direct solid sampling analysis gave results similar to those obtained with the slurry technique with ultrasonic agitation for the determination of iron in certified reference materials with iron content up to about 100 g g–1, but was too sensitive for the investigated rice plants, which had an iron content up to several mg g–1. The slurry technique with ultrasonic treatment of the samples, suspended in dilute nitric acid, was finally adopted as the method of choice.The method was then applied for the determination of iron in the leaves and in different compartments of the roots of two rice cultivars, one sensitive to iron toxicity, an important nutritional disorder, and the other one resistant to iron toxicity. The results suggest that the higher resistance to iron toxicity of the second cultivar is due to a smaller uptake of iron from the soil, resulting in lower iron levels in all compartments of the plant.  相似文献   

19.
A method involving comprehensive two‐dimensional gas chromatography coupled to high‐resolution time‐of‐flight mass spectrometry was developed and applied to the analysis of nitrogenous organic compounds present in mainstream cigarette smoke trapped on self‐designed equipment. The samples were prepared using low‐temperature solvent extraction under liquid nitrogen and analyzed by comprehensive two‐dimensional gas chromatography with high‐resolution time‐of‐flight mass spectrometry. Important experimental parameters, such as the type and volume of the extraction solvent and flow rate of smoking, were optimized to improve the analysis parameter. The results indicated that 180 mL of diethyl ether in the low‐temperature solvent extraction apparatus system with a 4 mL/min smoke flow rate were the optimal conditions. Then, 85 nitrogenous organic compounds were identified and quantified using a mass spectral library search, accurate mass ion and N‐rules of a molecular formula for nitrogen compounds. Finally, a comparison of the low temperature solvent extraction method and Cambridge filter pad method indicated that more peaks, a higher peak volume and better repeatability were obtained using the low‐temperature solvent extraction method.  相似文献   

20.
In this work we demonstrate the potential of glycan reductive isotope labeling (GRIL) using [12C]- and [13C]-coded aniline and zwitterionic hydrophilic interaction capillary liquid chromatography electrospray mass spectrometry (μZIC-HILIC-ESI-MS) for relative quantitation of glycosylation variants in selected glycoproteins present in samples from cancer patients. Human α1-acid-glycoprotein (hAGP) is an acute phase serum glycoprotein whose glycosylation has been described to be altered in cancer and chronic inflammation. However, it is not clear yet whether some particular glycans in hAGP can be used as biomarker for differentiating between these two pathologies. In this work, hAGP was isolated by immunoaffinity chromatography (IAC) from serum samples of healthy individuals and from those suffering chronic pancreatitis and different stages of pancreatic cancer, respectively. After de-N-glycosylation, relative quantitation of the hAGP glycans was carried out using stable isotope labeling and μZIC-HILIC-ESI-MS analysis. First, protein denaturing conditions prior to PNGase F digestion were optimized to achieve quantitative digestion yields, and the reproducibility of the established methodology was evaluated with standard hAGP. Then, the proposed method was applied to the analysis of the clinical samples (control vs. pathological). Pancreatic cancer samples clearly showed an increase in the abundance of fucosylated glycans as the stage of the disease increases and this was unlike to samples from chronic pancreatitis. The results gained here indicate the mentioned glycan in hAGP as a candidate structure worth to be corroborated by an extended study including more clinical cases; especially those with chronic pancreatitis and initial stages of pancreatic cancer. Importantly, the results demonstrate that the presented methodology combining an enrichment of a target protein by IAC with isotope coded relative quantitation of N-glycans can be successfully used for targeted glycomics studies. The methodology is assumed being suitable as well for other such studies aimed at finding novel cancer associated glycoprotein biomarkers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号