首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A multilaboratory study was conducted to compare performance of the GeneQuence DNA hybridization (DNAH) method incorporating new 24 h enrichment protocols and reference culture procedures for detection of Salmonella spp. in select foods. Six food types (raw ground turkey, raw ground beef, dried whole egg, milk chocolate, walnuts, and dry pet food) were tested by the DNAH method and by the culture methods of either the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) or the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA/BAM). Fifteen laboratories participated in the study. Four of the foods tested (raw ground turkey, dried whole egg, milk chocolate, and dry pet food), showed no statistically significant differences in performance between the DNAH method and the reference procedure as determined by Chi square analysis. Sensitivity rates for the DNAH method ranged from 92 to 100%. The DNAH method, with the specific enrichment protocol evaluated, was found to be ineffective for detection of Salmonella spp. in walnuts. For raw ground beef, results from one trial showed a statistically significant difference in performance, with more positives obtained by the reference method. However, evidence suggests that the difference in the number of positives was likely due to lack of homogeneity of the test samples rather than to DNAH method performance.  相似文献   

2.
A multilaboratory study was conducted to compare the automated BAX system and the standard cultural methods for detection of Listeria monocytogenes in foods. Six food types (frankfurters, soft cheese, smoked salmon, raw, ground beef, fresh radishes, and frozen peas) were analyzed by each method. For each food type, 3 inoculation levels were tested: high (average of 2 CFU/g), low (average of 0.2 CFU/g) and uninoculated controls. A total of 25 laboratories representing government and industry participated. Of the 2335 samples analyzed, 1109 were positive by the BAX system and 1115 were positive by the standard method. A Chi square analysis of each of the 6 food types, at the 3 inoculation levels tested, was performed. For all foods, except radishes, the BAX system performed as well as or better than the standard reference methods based on the Chi square results.  相似文献   

3.
New enrichment protocols are described for use with a DNA hybridization (DNAH) method for detection of Salmonella spp. in select foods. GeneQuence Salmonella, in its original version, utilized a 3-stage enrichment of minimum 42 h duration. New 2-stage procedures of 24-28 h duration are described for raw poultry, raw beef, pasteurized egg products, milk chocolate, and dry pet food. In the validation study described here, a total of 345 samples were tested by the abbreviated DNAH method in parallel with either the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA/BAM) or U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) reference culture procedures. Results showed an overall sensitivity for the DNAH method of 97.1% (false-negative rate 2.9%). There were no false-positive results by the DNAH method; therefore the specificity was 100%. Overall agreement between the DNAH and reference culture methods was 98.5%. There were no significant differences in performance between the DNAH and reference methods for any of the foods tested as determined by Chi-square analysis. It is recommended that the DNAH method be subjected to AOAC collaborative study.  相似文献   

4.
A collaborative study was conducted to compare the VIDAS Salmonella (SLM) with Rappaport-Vassiliadis (RV) method for detection of Salmonella in foods to the current standard method presented in the U.S. Food and Drug Administration's Bacteriological Analytical Manual (BAM) and the culture method presented in AOAC's Official Methods of Analysis. The VIDAS SLM with RV method uses tetrathionate broth in combination with RV medium in place of selenite cystine broth for selective enrichment, thereby eliminating the hazardous waste issue for laboratories. Twenty five laboratories participated in the evaluation, each testing one or more of 8 test products: nonfat dry milk, dried egg, soy flour, lactic casein, milk chocolate, raw ground pork, raw ground turkey, and raw peeled shrimp. Results of the study showed no significant differences in the numbers of confirmed positive samples with the VIDAS SLM with RV procedure and the BAM/AOAC culture procedure. The VIDAS SLM with RV method was effective for rapid detection of Salmonella in foods. It is recommended that AOAC INTERNATIONAL modify the VIDAS Salmonella SLM procedure to include the RV method.  相似文献   

5.
Six foods representative of a wide variety of processed, dried powder processed, and raw food types were analyzed by the Visual Immunoprecipitate Assay (VIP) for Salmonella and AOAC INTERNATIONAL culture method. Paired samples of each food type were simultaneously analyzed; one sample by the VIP method and one by the AOAC culture method. A total of 24 laboratories representing federal government agencies and private industry, in the United States and Canada, participated in this collaborative study. Food types were inoculated with species of Salmonella with the exception of raw ground chicken, which was naturally contaminated. No statistical differences (p < 0.05) were observed between VIP for Salmonella interpretation and the AOAC culture method for any inoculation level of any food type or naturally contaminated food. The method was adopted Official First Action status by AOAC INTERNATIONAL.  相似文献   

6.
Real-time PCR methods for detecting foodborne pathogens offer the advantages of simplicity and quick time-to-results compared to traditional culture methods. In this study, the MicroSEQ real-time PCR system was evaluated for detection of Salmonella spp. in 10 different food matrixes following the AOAC Research Institute's Performance Tested Method validation program. In addition, the performance of the MicroSEQ system was evaluated for the detection of Salmonella in peanut butter as a part of the Emergency Response Validation Program sponsored by the AOAC Research Institute. The system was compared to the ISO 6579 reference method using a paired-study design for detecting Salmonella spp. in raw ground beef, raw chicken, raw shrimp, Brie cheese, shell eggs, cantaloupe, chocolate, black pepper, dry infant formula, and dry pet food. For the peanut butter study, the system was compared to the U.S. Food and Drug Administration's Bacteriological Analytical Manual procedures using an unpaired-study design. No significant difference in performance was observed between the MicroSEQ Salmonella spp. detection system and the corresponding reference methods for all 11 food matrixes. The MicroSEQ system detected all Salmonella strains tested, while showing good discrimination against detection of an exclusivity panel of 30 strains, with high accuracy.  相似文献   

7.
Reveal Salmonella 2.0 is an improved version of the original Reveal Salmonella lateral flow immunoassay and is applicable to the detection of Salmonella enterica serogroups A-E in a variety of food and environmental samples. A Performance Tested Method validation study was conducted to compare performance of the Reveal 2.0 method with that of the U.S. Department of Agriculture-Food Safety and Inspection Service or U.S. Food and Drug Administration/Bacteriological Analytical Manual reference culture methods for detection of Salmonella spp. in chicken carcass rinse, raw ground turkey, raw ground beef, hot dogs, raw shrimp, a ready-to-eat meal product, dry pet food, ice cream, spinach, cantaloupe, peanut butter, stainless steel surface, and sprout irrigation water. In a total of 17 trials performed internally and four trials performed in an independent laboratory, there were no statistically significant differences in performance of the Reveal 2.0 and reference culture procedures as determined by Chi-square analysis, with the exception of one trial with stainless steel surface and one trial with sprout irrigation water where there were significantly more positive results by the Reveal 2.0 method. Considering all data generated in testing food samples using enrichment procedures specifically designed for the Reveal method, overall sensitivity of the Reveal method relative to the reference culture methods was 99%. In testing environmental samples, sensitivity of the Reveal method relative to the reference culture method was 164%. For select foods, use of the Reveal test in conjunction with reference method enrichment resulted in overall sensitivity of 92%. There were no unconfirmed positive results on uninoculated control samples in any trials for specificity of 100%. In inclusivity testing, 102 different Salmonella serovars belonging to serogroups A-E were tested and 99 were consistently positive in the Reveal test. In exclusivity testing of 33 strains of non-salmonellae representing 14 genera, 32 were negative when tested with Reveal following nonselective enrichment, and the remaining strain was found to be substantially inhibited by the enrichment media used with the Reveal method. Results of ruggedness testing showed that the Reveal test produces accurate results even with substantial deviation in sample volume or device development time.  相似文献   

8.
Six foods representative of a wide variety of processed, dried powder processed, and raw food types were analyzed by the Assurance Gold Salmonella Enzyme Immunoassay (EIA) and AOAC INTERNATIONAL culture method. Paired samples of each food type were simultaneously analyzed; one sample by the Assurance method and one by the AOAC culture method. The results for Assurance method were read visually and instrumentally with a microplate reader. A total of 24 laboratories representing federal government agencies and private industry, in the United States and Canada, participated in this collaborative study. Food types were inoculated with species of Salmonella with the exception of raw ground chicken, which was naturally contaminated. No statistical differences (p < 0.05) were observed between Assurance Gold Salmonella EIA with either visual or instrumental interpretation and the AOAC culture method for any inoculation level of any food type or naturally contaminated food. The Assurance visual and instrumental options of reading sample reactions produced the same results for 1277 of the 1296 sample and controls analyzed.  相似文献   

9.
The TECRA Unique Salmonella test uses the principle of immunoenrichment to allow rapid detection of Salmonellae in food. A collaborative study was conducted to compare the TECRA Salmonella Unique test with the reference culture method given in the U.S. Food and Drug Administration's Bacteriological Analytical Manual. Three food types (milk powder, pepper, and soy flour) were analyzed in Australia and 2 food types (milk chocolate and dried egg) were analyzed in the United States. Forty-one collaborators participated in the study. For each of the 5 foods at each of the 3 levels, a comparison showed no significant differences (p > or = 0.05) in the proportion of positive test samples for Unique and that for the reference method using the Chi-square test for independence with continuity correction.  相似文献   

10.
A multilaboratory study was conducted to compare the automated BAX System to the standard cultural methods for detection of Salmonella in selected foods. Five food types--frankfurters, raw ground beef, mozzarella cheese, raw frozen tilapia fish, and orange juice--at 3 inoculation levels, were analyzed by each method. A sixth food type, raw ground chicken, was tested using 3 naturally contaminated lots. A total of 16 laboratories representing government and industry participated. In this study, 1386 samples were analyzed, of which 1188 were paired samples and 198 were unpaired samples. Of the 1188 paired samples, 461 were positive by both methods and 404 were negative by both methods. Thirty-seven samples were positive by the BAX System but negative by the standard reference method, and 11 samples were positive by standard cultural method and negative by the BAX System. Of the 198 unpaired samples, 106 were positive by the BAX System and 60 were positive by the standard cultural method. A Chi square analysis of each of the 6 food types, at the 3 inoculation levels tested, was performed. For all foods, the BAX System demonstrated results comparable to those of the standard reference methods based on the Chi square results.  相似文献   

11.
A method was developed for the detection of Listeria monocytogenes in food. The method is based on real-time PCR using hydrolysis probes (5' Nuclease). This advanced PCR method was designed to reduce the time necessary to achieve results from PCR reactions and to enable the user to monitor the amplification of the PCR product simultaneously, in real-time. After DNA isolation using the BIOTECON foodproof ShortPrep II Kit designed for the rapid preparation of L. monocytogenes DNA for direct use in PCR, the real-time detection of L. monocytogenes DNA is carried out using the foodproof Listeria monocytogenes Detection Kit. The kit provides primers and hydrolysis probes for sequence-specific detection, convenient premixed reagents, and controls for reliable interpretation of results. For the internal comparison study, three different foods (soft cheese, coalfish, and smoked ham) were analyzed, chosen from the 15 food groups recommended by the AOAC Research Institute for detection of L. monocytogenes. From each food, 20 samples were inoculated with a low level (1-10 CFU/25 g) and 20 samples with a high level (10-50 CFU/25 g) of L. monocytogenes. Additionally, five nonspiked samples were prepared from each food. Depending on the matrix, the food samples were examined with the test kits and compared with the cultural methods according to the U.S. Food and Drug Administration's Bacteriological Analytical Manual or the U.S. Department of Agriculture/Food Safety and Inspection Service Microbiology Laboratory Guidebook.  相似文献   

12.
The TECRA Salmonella Visual Immunoassay (VIA) using Rappaport-Vassiliadis RV[R10] as a single selective enrichment broth has Final Action approval (AOAC Method 998.09). TECRA has recently developed a protocol (TECRA ULTIMA), which involves the addition of a new additive to a 1 mL aliquot of the RV[R10] broth, prior to the heat-killing step, thereby allowing the RV[R10] broth to be tested directly in the kit and thus eliminating the need for the 2 h post-enrichment in M broth. An in-house validation study was conducted to compare the modified AOAC Method 998.09 to the reference culture method. Three foods were used in the study: Naturally contaminated raw ground poultry at high (10-50 cells/25 g), and low (1-5 cells/25 g) levels; and milk powder and peanut butter, artificially inoculated at low and high levels with Salmonella bovismorbificans and S. enterica Mbandaka, respectively. Twenty test portions were analyzed for each level with 10 uninoculated control samples per food. Overall, no significant differences (p <0.05) were observed when the proportion of positive test portions for the modified VIA were compared with that for the reference method. This minor modification, which employs the additive (provided in the TECRA ULTIMA SALMONELLA Test Kit) to permit the direct analysis of RV[R10] broth has demonstrated the utility of the TECRA ULTIMA SALMONELLA protocol. It is recommended that the minor modification to Method 998.09 be approved First Action as an additional option within the method.  相似文献   

13.
A method was developed for the detection of L. monocytogenes in food based on real-time polymerase chain reaction (PCR). This advanced PCR method was designed to reduce the time needed to achieve results from PCR reactions and to enable the user to monitor the amplification of the PCR product simultaneously, in real-time. After DNA isolation using the Roche/BIOTECON Diagnostics ShortPrep foodproof II Kit (formerly called Listeria ShortPrep Kit) designed for the rapid preparation of L. monocytogenes DNA for direct use in PCR, the real-time detection of L. monocytogenes DNA is performed by using the Roche/BIOTECON Diagnostics LightCycler foodproof L. monocytogenes Detection Kit. This kit provides primers and hybridization probes for sequence-specific detection, convenient premixed reagents, and different controls for reliable interpretation of results. For repeatability studies, 20 different foods, covering the 15 food groups recommended from the AOAC Research Institute (AOAC RI) for L. monocytogenes detection were analyzed: raw meats, fresh produce/vegetables, processed meats, seafood, egg and egg products, dairy (cultured/noncultured), spices, dry foods, fruit/juices, uncooked pasta, nuts, confectionery, pet food, food dyes and colorings, and miscellaneous. From each food 20, samples were inoculated with a low level (1-10 colony-forming units (CFU)/25 g) and 20 samples with a high level (10-50 CFU/25 g) of L. monocytogenes. Additionally, 5 uninoculated samples were prepared from each food. The food samples were examined with the test kits and in correlation with the cultural methods according to U.S. Food and Drug Administration (FDA) Bacteriological Analytical Manual (BAM) or U.S. Department of Agriculture (USDA)/Food Safety and Inspection Service (FSIS) Microbiology Laboratory Guidebook. After 48 h of incubation, the PCR method in all cases showed equal or better results than the reference cultural FDA/BAM or USDA/FSIS methods. Fifteen out of 20 tested food types gave exactly the same amount of positive samples for both methods in both inoculation levels. For 5 out of 20 foodstuffs, the PCR method resulted in more positives than the reference method after 48 h of incubation. Following AOAC RI definition, these were false positives because they were not confirmed by the reference method (false-positive rate for low inoculated foodstuffs: 5.4%; for high inoculated foodstuffs: 7.1%). Without calculating these unconfirmed positives, the PCR method showed equal sensitivity results compared to the alternative method. With the unconfirmed PCR-positives included into the calculations, the alternative PCR method showed a higher sensitivity than the microbiological methods (low inoculation level: 100 vs 98.0%; sensitivity rate: 1; high inoculation level: 99.7 vs 97.7%; sensitivity rate, 1). All in-house and independently tested uninoculated food samples were negative for L. monocytogenes. The ruggedness testing of both ShortPrep foodproof II Kit and Roche/BIOTECON LightCycler foodproof L. monocytogenes Detection Kit showed no noteworthy influences to any variation of the parameters component concentration, apparatus comparison, tester comparison, and sample volumes. In total, 102 L. monocytogenes isolates (cultures and pure DNA) were tested and detected for the inclusivity study, including all isolates claimed by the AOAC RI. The exclusivity study included 60 non-L. monocytogenes bacteria. None of the tested isolates gave a false-positive result; specificity was 100%. Three different lots were tested in the lot-to-lot study. All 3 lots gave equal results. The stability study was subdivided into 3 parts: long-term study, stress test, and freeze-defrost test. Three lots were tested in 4 time intervals within a period of 13 months. They all gave comparable results for all test intervals. For the stress test, LightCycler L. monocytogenes detection mixes were stored at different temperatures and tested at different time points during 1 month. Stable results were produced at all storage temperatures. The freeze-defrost analysis showed no noteworthy aggravation of test results. The independent validation study examined by Campden and Chorleywood Food Research Association Group (CCFRA) demonstrated again that the LightCycler L. monocytogenes detection system shows a comparable sensitivity to reference methods. With both the LightCycler PCR and BAM methods, 19 out of 20 inoculated food samples were detected. The 24 h PCR results generated by the LightCycler system corresponded directly with the FDA/BAM culture results. However, the 48 h PCR results did not relate exactly to the FDA/BAM results, as one sample found to be positive by the 48 h PCR could not be culturally confirmed and another sample which was negative by the 48 h PCR was culturally positive.  相似文献   

14.
Three food types were analyzed for the presence of Salmonella by the AOAC culture method and by the International Organization for Standardization (ISO 6579:2002) culture method. Paired test portions of each food type were simultaneously analyzed by both methods. A total of 21 laboratories representing federal government agencies and private industry, in the United States and Europe, participated in this interlaboratory study. Foods were artificially contaminated with Salmonella and competing microflora if naturally contaminated sources were not available. No statistical differences (p < 0.05) were observed between the AOAC and ISO culture methods for fresh cheese and dried egg products. A statistically significant difference was observed for one of the 2 lots of poultry from the first trial. The poultry meat used in this run was radiation sterilized, artificially contaminated with Salmonella and competitive flora, and then lyophilized. A second trial was conducted with 2 separate lots of raw ground chicken that were naturally contaminated. The results from the second trial showed no statistical difference between the 2 culture methods. A third trial involving 4 laboratories was conducted on 2 separate lots of naturally contaminated raw poultry. Again, no statistically significant differences occurred. It is recommended that ISO 6579:2002 culture method for Salmonella be adopted Official First Action for the analysis of fresh cheese, fresh chilled and frozen poultry, and dried egg products.  相似文献   

15.
The VIDAS Immuno-concentration Salmonella (ICS) plus selective plate method (Hektoen enteric, xylose lysine desoxycholate, bismuth sulfite) method for the detection of Salmonella was compared to the Bacteriological Analytical Manual (BAM)/AOAC culture method in a collaborative study. Thirty-two laboratories participated in the evaluation. Each laboratory tested one or more of the 6 test products: milk chocolate, nonfat dry milk, dried whole egg, soy flour, ground black pepper, and ground raw turkey. The 2 methods were in agreement for 1,297 of the 1,455 samples. Of the 158 samples not in agreement, 82 were VIDAS ICS plus selective plate-positive and BAM/AOAC-negative, and 76 were VIDAS ICS plus selective plate-negative and BAM/AOAC-positive.  相似文献   

16.
The VIDAS Immuno-concentration Salmonella ICS)/VIDAS Salmonella (SLM) immunoassay method for the detection of Salmonella was compared to the Bacteriological Analytical Manual (BAM)/AOAC culture method in a collaborative study. Thirty-two laboratories participated in the evaluation. Each laboratory tested one or more of the 6 test products: milk chocolate, nonfat dry milk, dried whole egg, soy flour, ground black pepper, and ground raw turkey. The 2 methods were in agreement for 1,266 of the 1,440 samples. Of the 174 samples not in agreement, 69 were VIDAS CS/SLM-positive and BAM/AOAC-negative and 105 were VIDAS ICS/SLM-negative and BAM/AOAC-positive.  相似文献   

17.
A rehydratable dry-film plating method for Staphylococcus aureus in foods, the 3M Petrifilm Rapid S. aureus Count Plate method, was compared with AOAC Official Method 975.55 (Staphylococcus aureus in Foods). Nine foods-instant nonfat dried milk, dry seasoned vegetable coating, frozen hash browns, frozen cooked chicken patty, frozen ground raw pork, shredded cheddar cheese, fresh green beans, pasta filled with beef and cheese, and egg custard-were analyzed for S. aureus by 13 collaborating laboratories. For each food tested, the collaborators received 8 blind test samples consisting of a control sample and 3 levels of inoculated test sample, each in duplicate. The mean log counts for the methods were comparable for pasta filled with beef and cheese; frozen hash browns; cooked chicken patty; egg custard; frozen ground raw pork; and instant nonfat dried milk. The repeatability and reproducibility variances of the Petrifilm Rapid S. aureus Count Plate method were similar to those of the standard method.  相似文献   

18.
Twenty-three laboratories participated in a collaborative study to compare the relative effectiveness of Rappaport-Vassiliadis (RV) medium incubated at 42 degrees C, selenite cystine (SC) broth (35 degrees C), and tetrathionate (TT) broth (35 and 43 degrees C) for recovery of Salmonella from the following foods with a low microbial load: dried egg yolk, dry active yeast, ground black pepper, guar gum, and instant nonfat dry milk. For dry active yeast, lauryl tryptose (LT) broth, incubated at 35 degrees C, was used instead of SC broth. All of the foods were artificially inoculated with single Salmonella serovars, that had been lyophilized before inoculation, at high and low target levels of 0.4 and 0.04 colony forming units/g food, respectively. For analysis of 870 test portions, representing all of the foods except yeast, 249 Salmonella-positive test portions were detected by RV medium, 265 by TT broth (43 degrees C), 268 by TT broth (35 degrees C), and 269 by SC broth (35 degrees C). For analysis of 225 test portions of yeast, 79 Salmonella-positive test portions were detected by RV medium, 79 by TT broth (43 degrees C), 84 by TT broth (35 degrees C), and 68 by LT broth (35 degrees C). RV medium was comparable to, or even more effective than, the other selective enrichments for recovery of Salmonella from all of the foods except guar gum. It is recommended that RV (42 degrees C) and TT (35 degrees C) be used with foods that have a low microbial load, except for guar gum for which SC (35 degrees C) and TT (35 degrees C) are recommended.  相似文献   

19.
The VIDAS Immuno-concentration Salmonella (ICS) plus selective plate method (Hektoen enteric, bismuth sulfite, Salmonella identification) method for the detection of Salmonella was compared to the Bacteriological Analytical Manual (BAM)/AOAC culture method in a collaborative study. Thirty-two laboratories participated in the evaluation. Each laboratory tested one or more of the 6 test products: milk chocolate, nonfat dry milk, dried whole egg, soy flour, ground black pepper, and ground raw turkey. The 2 methods were in agreement for 1,283 of the 1,440 test samples. Of the 157 test samples not in agreement, 82 were VIDAS ICS plus selective plate-positive and BAM/AOAC-negative, and 75 were VIDAS ICS plus selective plate-negative and BAM/AOAC-positive.  相似文献   

20.
The VIDAS Salmonella (SLM) Easy Salmonella method is a specific enzyme-linked fluorescent immunoassay performed in the automated VIDAS instrument. The VIDAS Easy Salmonella method is a simple 2-step enrichment procedure, using pre-enrichment followed by selective enrichment in a newly formulated broth, SX2 broth. This new method was compared in a multilaboratory collaborative study to the U.S. Food and Drug Administration's Bacteriological Analytical Manual, Chapter 5 method for five food matrixes (liquid egg, vanilla ice cream, spinach, raw shrimp, and peanut butter) and the U.S. Department of Agriculture's Microbiology Laboratory Guidebook 4.04 method for deli turkey. Each food type was artificially contaminated with Salmonella at three inoculation levels. A total of 15 laboratories representing government, academia, and industry, throughout the United States, participated. In this study, 1583 samples were analyzed, of which 792 were paired replicates and 791 were unpaired replicates. Of the 792 paired replicates, 285 were positive by both the VIDAS and reference methods. Of the 791 unpaired replicates, 341 were positive by the VIDAS method and 325 were positive by the cultural reference method. A Chi-square analysis of each of the six food types was performed at the three inoculation levels tested. For all foods evaluated, the VIDAS Easy SLM method demonstrated results comparable to those of the reference methods for the detection of Salmonella.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号