首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this work, a novel sandwich-type electrochemical immunosensor based on host-guest interaction was fabricated for the detection of alpha-fetoprotein (AFP). Due to the large specific surface area of multiwalled carbon nanotubes and the unique supramolecular recognition ability of β-cyclodextrins, ferrocenecarboxylic acid (Fc) was incorporated into this sensor platform by host-guest interaction to generate an electrochemical signal. And β-cyclodextrins functionalized silver supported adamantine-modified glucose oxidase (GOD-CD-Ag), was used as a label to improve the analytical performance of the immunosensor by the dual amplification strategy. The obtained GOD-CD-Ag conjugates could convert glucose into gluconic acid with the formation of hydrogen peroxide (H2O2). And then silver nanoparticles could in situ catalyze the reduction of the generated H2O2, dramatically improving the oxidation reaction of Fc. The developed immunosensor shows a wide linear calibration range from 0.001 to 5.0 ng/mL with a low detection limit (0.2 pg/mL) for the detection of AFP. The method, with ideal reproducibility and selectivity, has a wide application prospect in clinical research.  相似文献   

2.
Here, a novel biosensing platform for the detection of SARS-CoV-2 usable both at voltammetric and impedimetric mode is reported. The platform was constructed on a multi-walled carbon nanotubes (MWCNTs) screen-printed electrode (SPE) functionalized by methylene blue (MB), antibodies against SARS-CoV-2 spike protein (SP), a bioactive layer of chitosan (CS) and protein A (PrA). The voltammetric sensor showed superior performances both in phosphate buffer solution (PBS) and spiked-saliva samples, with LOD values of 5.0±0.1 and 30±2.1 ng/mL, compared to 20±1.8 and 50±2.5 ng/mL for the impedimetric sensor. Moreover, the voltammetric immunosensor was tested in real saliva, showing promising results.  相似文献   

3.
Electrochemical detection combined with nanostructured sensor surfaces offers potentially low-cost, high-throughput solutions for detection of clinically significant proteins. Inkjet printing offers an inexpensive non-contact fabrication method for microelectronics that is easily adapted for incorporating into protein immunosensor devices. Herein we report the first direct fabrication of inkjet-printed gold nanoparticle arrays, and apply them to electrochemical detection of the cancer biomarker interleukin-6 (IL-6) in serum. The gold nanoparticle ink was printed on a flexible, heat resistant polyimide Kapton substrate and subsequently sintered to create eight-electrode arrays costing <0.2 euro per array. The inkjet-printed working electrodes had reproducible surface areas with RSD <3%. Capture antibodies for IL-6 were linked onto the eight-electrode array, and used in sandwich immunoassays. A biotinylated secondary antibody with 16-18 horseradish peroxidase labels was used, and detection was achieved by hydroquinone-mediated amperometry. The arrays provided a clinically relevant detection limit of 20 pg mL(-1) in calf serum, sensitivity of 11.4 nA pg(-1) cm(-2), and a linear dynamic range of 20-400 pg mL(-1).  相似文献   

4.
An immunosensor based on the supersandwich multienzyme-DNA label realizing the electron transfer between the enzyme's redox site and the electrode is proposed for the ultrasensitive detection of Interleukin-6 (IL-6) with a low detection limit of 0.05 pg mL(-1).  相似文献   

5.
Zhang M  Ge S  Li W  Yan M  Song X  Yu J  Xu W  Huang J 《The Analyst》2012,137(3):680-685
In this work, we reported a simple and sensitive sandwich-type electrochemiluminescence (ECL) immunosensor for carcinoembryonic antigen (CEA) on a gold nanoparticles (AuNPs) modified glassy carbon electrode (GCE). The Ru-silica (Ru(bpy)(3)(2+)-doped silica) capped nanoporous gold (NPG) (Ru-silica@NPG) composite was used as an excellent label with amplification techniques. The NPG was prepared with a simple dealloying strategy, by which silver was dissolved from silver/gold alloys in nitric acid. The primary antibody was immobilized on the AuNPs modified electrode through l-cysteine and glutaraldehyde, and then the antigen and the functionalized Ru-silica@NPG composite labeled secondary antibody were conjugated successively to form a sandwich-type immunocomplex through the specific interaction. The concentrations of CEA were obtained in the range from 1 pg mL(-1) to 10 ng mL(-1) with a detection limit of 0.8 pg mL(-1). The as-proposed ECL immunosensor has the advantages of high sensitivity, specificity and stability and could become a promising technique for tumor marker detection.  相似文献   

6.
Single-walled carbon nanotubes functionalized with poly-L-lysine (PLL-SWCNTs) were successfully prepared and were used as a biocompatible platform to immobilize α-fetoprotein antibody (anti-AFP) which was labeled with horseradish peroxidase (HRP). Then, anti-AFP-HRP/PLL-SWCNT nanocomposites were coated onto a Prussian blue (PB) film-modified glassy carbon electrode surface. Glutaraldehyde was used to further stabilize the biosensing interface through a cross-linking step. All unspecific sites were blocked by bovine serum albumin to fabricate a novel electrochemical immunosensor for α-fetoprotein determination. The immunosensor was characterized by voltammetry and electrochemical impedance spectroscopy. Based on the catalytic current response of H2O2, the experimental conditions for α-fetoprotein determination were optimized. Under optimal conditions, the current response was linearly related to α-fetoprotein concentration in the range of 0.05~10.0 and 10.0~50.0 ng/mL with a detection limit of 0.011 ng/mL. The immunosensor was successfully used for the determination of α-fetoprotein in human blood plasma. The results were satisfied with that obtained with ELISA, demonstrating a good accuracy of the immunosensor.  相似文献   

7.
Fluorescent gold nanoclusters (AuNCs) were incorporated into porous calcium carbonate spheres through electrostatic interaction. The resulting CaCO(3)/AuNCs hybrid material exhibited interesting properties, such as porous structure, excellent biocompatibility, good water solubility, and degradability. These properties make the CaCO(3)/AuNCs hybrid material a promising template to assemble horseradish peroxidase/antibody conjugates (HRP-Ab(2)). By using CaCO(3)/AuNCs/HRP-Ab(2) bioconjugates as probes, a versatile immunosensor was developed for fluorescent and electrochemical detection of the cancer biomarker neuron-specific enolase (NSE). The detection limits of the sensor were 2.0 and 0.1 pg mL(-1) for fluorescent and electrochemical detection, respectively. The immunosensor shows high sensitivity and offers an alternative strategy for the detection of other proteins and DNA.  相似文献   

8.
In the present study, we developed a novel label‐free capacitance impedimetric immunosensor based on the immobilization of the human monoclonal antibody anti‐interleukin‐10 (anti‐IL‐10 mAb) onto polypyrrole (PPy)‐modified silicon nitride (Si3N4) substrates. The immunosensor was used for the detection of the recombinant interleukin‐10 antigen (rh IL‐10) that may be secreted in patients at the early stage of inflammation. The immunosensor was created by chemical deposition of PPy conducting layer on pyrrole?silane (SPy)‐treated Si/SiO2/Si3N4 substrates (Si/SiO2/Si3N4?SPy), followed by anti‐IL‐10 mAb immobilization through carboxyl‐functionalized diazonium (CMA) protocol and carbodiimide chemistry. The surface characterization and the biofunctionalization steps were characterized by SEM, FTIR and cyclic voltammetry (CV) while the detection process was carried out by using electrochemical impedance spectroscopy (EIS) analyses. The created immunosensor showed two linear fittings (R2=0.999) for the detection of rh IL‐10 within the concentration range from 1–50 pg/mL. It exhibited high sensitivity (0.1128 (pg/mL)?1) with a very low limit of detection (LOD)=0.347 pg/mL, more particularly, at the low concentration range (1–10 pg/mL). Thus, this developed polypyrrole‐based immunosensor represents a promising strategy for creation of miniaturized label‐free, fast and highly sensitive biosensors for diagnosis of inflammation biomarkers at very low concentrations with reduced cost.  相似文献   

9.
A novel electrochemical immunosensor based on a magnetic glassy carbon electrode (MGCE) was developed for the quantitative determination of human immunoglobulin G (IgG). The immunosensing interface was fabricated by initially depositing silver nanoparticles on the MGCE surface and then immobilizing anti‐human IgG antibodies via the magnetic force between MGCE and Fe3O4 nanoparticles. The antibodies were covalently bonded to the amine‐functionalized Fe3O4 nanoparticles. Under optimal conditions, the magnetism‐assisted immunosensor exhibited a wide linear range from 0.1 pg/mL to 1.0 µg/mL with the detection limit of 0.05 pg/mL. Furthermore, the immunosensor displayed the advantages of good reproducibility and satisfactory stability.  相似文献   

10.
Novel luminescence‐functionalized metal–organic frameworks (MOFs) with superior electrogenerated chemiluminescence (ECL) properties were synthesized based on zinc ions as the central ions and tris(4,4′‐dicarboxylicacid‐2,2′‐bipyridyl)ruthenium(II) dichloride ([Ru(dcbpy)3]2+) as the ligands. For potential applications, the synthesized MOFs were used to fabricate a “signal‐on” ECL immunosensor for the detection of N‐terminal pro‐B‐type natriuretic peptide (NT‐proBNP). As expected, enhanced ECL signals were obtained through a simple fabrication strategy because luminescence‐functionalized MOFs not only effectively increased the loading of [Ru(dcbpy)3]2+, but also served as a loading platform in the ECL immunosensor. Furthermore, the proposed ECL immunosensor had a wide linear range from 5 pg mL?1 to 25 ng mL?1 and a relatively low detection limit of 1.67 pg mL?1 (signal/noise=3). The results indicated that luminescence‐functionalized MOFs provided a novel amplification strategy in the construction of ECL immunosensors and might have great prospects for application in bioanalysis.  相似文献   

11.
Wu Y  Liu S  He L 《The Analyst》2011,136(12):2558-2563
We present a novel immunosensor by using polymerization-assisted signal amplification strategy coupled with electrochemical detection. A sandwich immunoassay process was used to immobilize a polymerization reaction center, the initiator-conjugated polyclonal prostate specific antigen (PSA) or polyclonal carcinoembryonic antigen (CEA) antibodies on the surface of the electrode. Activator generated electron transfer for atom transfer radical polymerization (AGET ATRP) subsequently triggered the local accumulation of glycidyl methacrylate (GMA) monomers. Growth of long chain polymers provided excess epoxy groups for electrochemical tags aminoferrocene (FcNH(2)) coupling, which in turn significantly increased the loading of the signal molecules and enhanced the electrochemical readouts. The detection limit was ~0.14 pg mL(-1) for PSA and ~0.10 pg mL(-1) for CEA in PBS buffers. The proposed immunosensor was highly sensitive, selective and has a good match to the clinical electrochemiluminescent method. This suggested that the polymerization-assisted immunosensing strategy could be used as an effective method to significantly enhance signal output of the sandwich immunoassays and acted as a promising platform for the clinical screening of cancer biomarkers.  相似文献   

12.
Sharma P  Bhalla V  Tuteja S  Kukkar M  Suri CR 《The Analyst》2012,137(10):2495-2502
A solid phase extraction micro-cartridge containing a non-polar polystyrene absorbent matrix was coupled with an electrochemical immunoassay analyzer (EIA) and used for the ultra-sensitive detection of the phenyl urea herbicide diuron in real samples. The EIA was fabricated by using carboxylated carbon nanotubes (CNTs) functionalized with a hapten molecule (an amine functionalized diuron derivative). Screen printed electrodes (SPE) were modified with these haptenized CNTs and specific in-house generated anti diuron antibodies were used for bio-interface development. The immunodetection was realized in a competitive electrochemical immunoassay format using alkaline phosphatase labeled secondary anti-IgG antibody. The addition of 1-naphthyl phosphate substrate resulted in the production of an electrochemically active product, 1-naphthol, which was monitored by using differential pulse voltammetry (DPV). The assay exhibited excellent sensitivity and specificity having a dynamic response range of 0.01 pg mL(-1) to 10 μg mL(-1) for diuron with a limit of detection of around 0.1 pg mL(-1) (n = 3) in standard water samples. The micro-cartridge coupled hapten-CNTs modified SPE provided an effective and efficient electrochemical immunoassay for the real-time monitoring of pesticides samples with a very high degree of sensitivity.  相似文献   

13.
Zhang Y  Ge S  Wang S  Yan M  Yu J  Song X  Liu W 《The Analyst》2012,137(9):2176-2182
A novel electrochemiluminescence (ECL) immunosensor for sensitive detection of human chorionic gonadotrophin antigen (HCG-Ag) was constructed using CdTe quantum dot functionalized nanoporous PtRu alloys (QDs@PtRu) as labels for signal amplification. In this paper, nanoporous PtRu alloy was employed as the carrier for immobilization of CdTe QDs and antibodies. Primary monoclonal antibody to alfa-HCG antigen (McAb(1)) was immobilized onto the surface of chitosan coated Fe(3)O(4) magnetic nanoparticles (Fe(3)O(4)/CS MNPs) by glutaraldehyde (GA) as coupling agent. Then McAb(1) could be easily separated and assembled on the surface of indium tin oxide glass (ITO) owing to their excellent magnetic properties with external magnetic forces holding the MNPs. Due to signal amplification from the high loading of CdTe QDs, 4.67-fold enhancements in ECL signal for HCG-Ag detection was achieved compared to the unamplified method (single QDs as labels). Under optimal conditions, a wide detection range (0.005~50 ng mL(-1)) and low detection limit (0.8 pg mL(-1)) were achieved through the sandwich-type immunosensor. The novel immunosensor showed high sensitivity and selectivity, excellent stability, and good reproducibility, and thus has great potential for clinical detection of HCG-Ag. In particular, this approach presents a novel class of combining bifunctional nanomaterials with preferable ECL properties and excellent magnetism, which suggests considerable potential in a wide range of applications for bioassays.  相似文献   

14.
基于AuNPs/PDDA-GO纳米复合物制备了一种新型电化学免疫传感器, 并将其用于SirT1的检测. 首先, 在电极表面修饰复合材料AuNPs/PDDA-GO, 然后将目标蛋白SirT1固定到修饰了AuNPs/PDDA-GO的电极表面, 再通过特异性免疫反应结合一抗(Ab1)和辣根过氧化酶标记的二抗分子(HRP-Ab2), 最后用示差脉冲伏安法检测电流信号, 实现了对SirT1蛋白水平的测定. 在优化的实验条件下, SirT1蛋白的浓度在0.1~100 ng/mL范围内与响应电流呈良好线性关系, 检出限为0.029 ng/mL.  相似文献   

15.
A new alpha-fetoprotein-MIP (AFP-MIP) immunosensor based on glass carbon electrode (GCE) modified with polythionine (PTh) and gold nanoparticles (AuNPs) was successfully prepared for the sensitive detection of AFP. The AFP-MIP immunosensor presented a facile preparation, low sample consumption, and good stability, and could become a new promising method for the detection of AFP.  相似文献   

16.
Zhang M  Dai W  Yan M  Ge S  Yu J  Song X  Xu W 《The Analyst》2012,137(9):2112-2118
An ultrasensitive electrochemiluminescence (ECL) immunosensor was developed using PtAg@carbon nanocrystals (CNCs) as excellent labels based on carbon nanotubes-chitosan/AuNPs (CNT-CHIT/AuNPs) composite modified screen-printed carbon electrodes (SPCEs) for prostate protein antigen (PSA) detection. The CNCs were obtained simply by electro-oxidation of graphite with abundant carboxyl groups at their surfaces. The PtAg bimetallic nanocomposites with hierarchically hollow structures were fabricated through simple replacement reaction using dealloyed nanoporous silver (NPS) as both a template and reducing agent. Structure characterization was obtained by means of transmission electron microscope (TEM) and scanning electron microscope (SEM) images. The PtAg@CNCs composites exhibit a 6 times higher ECL intensity than the pure CNCs labeled anti-PSA. The as-prepared CNT-CHIT/AuNPs composite can attach more antibody than pure CNTs. Due to the dual-amplification techniques, the concentrations of PSA were obtained in the range from 1 pg mL(-1) to 50 ng mL(-1) with a detection limit of 0.6 pg mL(-1). Finally, the as-proposed ECL immunosensor has the advantages of high sensitivity, specificity and stability and could become a promising technique for tumor marker detection.  相似文献   

17.
Graphdiyne (GDY) was a novel flat material with sp and sp2 hybridized carbon atoms. It exhibited good biocompatibility. The application of GDY in PEC immunosensor was very limited. Thus, a novel photoelectrochemical sensor for the sensitive detection of prostate specific antigen (PSA) was proposed by using GDY oxide (GDYO) conjugated with horseradish peroxidase (HRP) and secondary antibody for photocurrent signal inhibition. GDYO was prepared by oxidation of honeycomb-like nanotubes composed of numerous GDY nanosheets. It showed high loading capacity for HRP and the catalytic activity of HRP could be remained. With reduced graphene oxide-CdS (rGO-CdS) as photoelectrochemical sensing platform, a sandwich-type photoelectrochemical (PEC) immunosensor was thus fabricated. The immunosensor presented a wide linear concentration range of 10 fg mL−1–20.0 ng mL−1 with a detection limit (LOD) of 3.5 fg mL−1. Moreover, the PEC immunosensor displayed ideal reproducibility, stability, and selectivity, which was a promising platform for the detection of other important tumor targets.  相似文献   

18.
We describe herein the combination of electrochemical immunosensors using single-wall carbon nanotube (SWNT) forest platforms with multi-label secondary antibody-nanotube bioconjugates for highly sensitive detection of a cancer biomarker in serum and tissue lysates. Greatly amplified sensitivity was attained by using bioconjugates featuring horseradish peroxidase (HRP) labels and secondary antibodies (Ab(2)) linked to carbon nanotubes (CNT) at high HRP/Ab(2) ratio. This approach provided a detection limit of 4 pg mL(-)(1) (100 amol mL(-)(1)), for prostate specific antigen (PSA) in 10 microL of undiluted calf serum, a mass detection limit of 40 fg. Accurate detection of PSA in human serum samples was demonstrated by comparison to standard ELISA assays. PSA was quantitatively measured in prostate tissue samples for which PSA could not be differentiated by the gold standard immunohistochemical staining method. These easily fabricated SWNT immunosensors show excellent promise for clinical screening of cancer biomarkers and point-of-care diagnostics.  相似文献   

19.
This work designed a simple, sensitive, and low-cost immunosensor for the detection of protein marker by using a carbon sphere/gold nanoparticle (CNS/AuNP) composite as an electrochemical label. The nanoscale carbon spheres, prepared with a hydrothermal method by using glucose as raw material, were used to load AuNPs for labeling antibody by electrostatic interaction, which provided a feasible pathway for electron transfer due to the remarkable conductivity. The disposable immunosensor was constructed by coating a polyethylene glycol (PEG) film on a screen-printed carbon-working electrode and then immobilizing capture antibody on the film. With a sandwich-type immunoassay format, the analyte and then the CNS/AuNP-labeled antibody were successively bound to the immunosensor. The bound AuNPs were finally electro-oxidized in 0.1 M HCl to produce AuCl(4)(-) for differential pulse voltammetric (DPV) detection. The high-loading capability of AuNPs on CNS for the sandwich-type immunorecognition led to obvious signal amplification. By using human immunoglobulin?G (IgG) as model target, the DPV signal of AuNPs after electro-oxidized at optimal potential of +1.40?V for 40?s showed a wide linear dependence on the logarithm of target concentration ranging from 10?pg mL(-1) to 10?ng mL(-1). The detection limit was around 9?pg mL(-1). The immunosensor showed excellent analytical performance with cost effectivity, good fabrication reproducibility, and acceptable precision and accuracy, providing significant potential application in clinical analysis.  相似文献   

20.
Zhang X  Liu F  Yan R  Xue P  Li Y  Chen L  Song C  Liu C  Jin B  Zhang Z  Yang K 《Talanta》2011,85(2):1070-1074
Staphylococcal enterotoxin B (SEB) is a potent gastrointestinal toxin and is heat resistant. SEB is also a potential bioterrorism agent. The ability to measure accurately very low amounts of staphylococcal enterotoxin B in food and other samples is very important. A highly sensitive and stable sandwich fluorescence immunoassay based on a pair of monoclonal antibodies against SEB which were produced by us was developed. Classical sandwich immunoassay was adopted and the glass slides were used as the base of the immunologic reaction. The functionalized fluorescent core-shell silica nanoparticles were used as labels. The fluorescence issued from the labels was detected by a laser-induced fluorescence millimeter sensor array detection platform. The fluorescence intensity has a linear relationship with the amount of SEB in the range of 50 pg/mL-5 ng/mL, and the detection limit of SEB was 20 pg/mL (the absolute detection limit was 0.02 pg). The relative standard deviation (RSD) for 5 parallel measurements of SEB (1 ng/mL) was 9.2%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号