首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
《Electrophoresis》2017,38(9-10):1353-1365
Capillary and microfluidic chip electrophoresis technologies are heavily utilized for development, characterization, release, and stability testing of biopharmaceuticals. Within the biopharmaceutical industry, CE‐SDS and M‐CGE are commonly used for purity determination by separation and quantitation of size‐based variants. M‐CGE is used primarily as an R&D tool for product and process development, while cGMP release and stability testing applications are commonly reserved for CE‐SDS. This paper describes the establishment of an M‐CGE platform method to be used for R&D and cGMP applications, including release and stability testing, for monoclonal antibodies. The M‐CGE platform method enables testing for product development support and cGMP release and stability using the same method, and utilization of one CE technology for the entire lifecycle of a biopharmaceutical product. Critical method parameters were identified, and the analytical design space of those critical parameters was defined using design of experiments (DOE) studies. Once defined through DOE studies, the method design space was validated according to ICH Q2 (R1) guidelines. Additional molecules of the same validated class were verified for use in the method by experimental confirmation of accuracy, specificity, and stability indicating capabilities. The platform method model facilitates rapid utilization of the method in development and GMP testing environments, and eliminates the need for individual validations for assets of the same class entering early stage development.  相似文献   

3.
High-throughput rheology in a microfluidic device   总被引:2,自引:0,他引:2  
Schultz KM  Furst EM 《Lab on a chip》2011,11(22):3802-3809
High-throughput rheological measurements in a microfluidic device are demonstrated. A series of microrheology samples are generated as droplets in an immiscible spacer fluid using a microfluidic T-junction. The compositions of the sample droplets are continuously varied over a wide range. Rheology measurements are made in each droplet using multiple particle tracking microrheology. We review critical design and operating parameters, including the droplet size, flow rates and rapid fabrication methods. Validation experiments are performed by measuring the solution viscosity of glycerine and the biopolymer heparin as a function of concentration. Overall, the combination of microrheology with microfluidics maximizes the number of rheological measurements while simultaneously minimizing the sample preparation time and amount of material, and should be particularly suited to the characterization of scarce or expensive materials.  相似文献   

4.
N-linked oligosaccharide standards obtained from commercial sources were derivatized with phenylhydrazine (PHN) and analyzed by on-line reversed-phase high performance liquid chromatography (HPLC)/electrospray ionization mass spectrometry (ESI-MS). This procedure was then applied to mixtures of N-glycans enzymatically released from hen ovalbumin. Under ESI-MS conditions, phenylhydrazones of asialylated oligosaccharide standards and ovalbumin glycans produced mainly [M + 2H]2+ molecular ions at low cone voltage values, while minimal fragmentation was observed. Reversed-phase HPLC/ESI-MS total and selected ion chromatograms obtained for derivatized N-glycans from ovalbumin showed partial but useful separation. Overall glycan profiles obtained by ESI-MS were compared with results obtained by matrix-assisted laser desorption/ionization (MALDI)-MS. Qualitatively, profiles were similar from one technique to the other in terms of relative abundance of glycans versus composition. Post-source decay (PSD) analysis of the [M + Na]+ ions of PHN-glycans showed dominant B, C and internal B/Y, C/Y cleavages. These patterns were helpful in relating fragmentation to proposed structures. Cross-ring cleavage fragment ions (A-type) were also observed in most cases. The PHN derivatization method is fast and simple. It produces abundant parent ions in both MALDI-MS and ESI-MS, while avoiding the presence of salt contaminants during the labeling procedure.  相似文献   

5.
N-linked oligosaccharides obtained from total serum of mice with implanted head and neck tumors were analyzed and compared with those from control samples of healthy mice. Methods used include a combination of a derivatization procedure with phenylhydrazine (PHN) and analysis by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Oligosaccharides were enzymatically released from total serum with PNGaseF and purified by high-performance liquid chromatography (HPLC) on a reversed-phase column. Mass spectra contained ion peaks of labeled oligosaccharides and MS/MS experiments provided useful data for the structural elucidation of these compounds. More than 40 N-glycans with compositions characteristic of high-mannose, hybrid, complex, neutral, and sialylated structures were identified in the serum of tumoral mice. Significant differences between samples were observed with respect to the abundances of high mannose and hybrid glycans. These oligosaccharides showed higher relative intensities in the spectra obtained from the cancer sera. Complex sialylated oligosaccharides had similar abundances in both types of sera, with the exception of fucosylated biantennary disialylated oligosaccharide, which was mostly detected with lower abundance in control samples. In the MALDI spectra, several minor species corresponded to uncommon carbohydrates. These structures have been investigated in detail by MS/MS. Among these novel glycoforms, a few sialylated oligosaccharides without a free reducing end were identified. Also, glycans with an extra 60 u were observed and likely feature the presence of a 2-acetamido-2-deoxyoctose residue attached on antennae of 3- or 6-linked mannose.  相似文献   

6.
刘莹  吕阳成  骆广生 《催化学报》2013,34(9):1635-1643
采用微流控技术结合悬浮聚合方法实现了百微米级含膦配体聚苯乙烯微胶囊的可控制备, 微胶囊尺寸在320~420 μm范围内可调, 且单分散性好. 扫描电子显微镜、能量散射光谱和电感耦合等离子发射光谱结果证实了其形貌和组成的均匀性及钯负载的可控性和有效性. 以溴代芳烃与苯硼酸的Suzuki偶联反应为模型反应评价了负载Pd(PPh3)4的百微米级微胶囊的催化性能, 发现其性能与文献报道的7~8 μm的同类催化剂微胶囊接近, 且均优于均相催化剂; 该催化剂经简单过滤后, 可实现多次循环使用, 未发现活性物种的流失. 该法实现了连续制备, 因而有助于提高制备的效率和可控性. 另外, 所制百微米级催化剂微胶囊在固定床反应器内具有较高催化剂浓度和机械性能, 且优于浆态床中使用的微米级催化剂微胶囊.  相似文献   

7.
In this work, a simple, flexible and low-cost sample-introduction technique was developed and integrated with droplet platform. The sample-introduction strategy was realized based on connecting the components of positive pressure input device, sample container and microfluidic chip through the tygon tubing with homemade polydimethylsiloxane (PDMS) adaptor, so the sample was delivered into the microchip from the sample container under the driving of positive pressure. This sample-introduction technique is so robust and compatible that could be integrated with T-junction, flow-focus or valve-assisted droplet microchips. By choosing the PDMS adaptor with proper dimension, the microchip could be flexibly equipped with various types of familiar sample containers, makes the sampling more straightforward without trivial sample transfer or loading. And the convenient sample changing was easily achieved by positioning the adaptor from one sample container to another. Benefiting from the proposed technique, the time-dependent concentration gradient was generated and applied for quantum dot (QD)-based fluorescence barcoding within droplet chip. High-throughput droplet screening was preliminarily demonstrated through the investigation of the quenching efficiency of ruthenium complex to the fluorescence of QD. More importantly, multiplex DNA assay was successfully carried out in the integrated system, which shows the practicability and potentials in high-throughput biosensing.  相似文献   

8.
The removal of N-linked oligosaccharides from glycoproteins is commonly performed during the preparation of samples for mass spectrometry. A reduction in the protein's structural heterogeneity is sometimes essential to obtain a mass for the intact protein. Alternatively, removal of the sugar may be desired to facilitate oligosaccharide analysis. A typical approach to deglycosylation employs overnight digestion with the enzyme peptide N-glycosidase F (PNGase F). We report a method for the accelerated removal of N-linked oligosaccharides using PNGase F assisted by microwave irradiation. Complete deglycosylation was achieved in less than 30 min for most proteins without compromising the integrity of protein samples. This method was tested on a variety of glycoproteins, including antibodies, at the microgram level.  相似文献   

9.
We previously reported that graphitized carbon column liquid chromatography-mass spectrometry (GCC-LC-MS) is very useful for the structural analysis of carbohydrates in a glycoprotein. In this study, GCC-LC-MS was adapted for the simultaneous microanalysis of oligosaccharides. A variety of oligosaccharide alditols prepared from fetuin, ribonuclease B, and recombinant human erythropoietin were used as model oligosaccharides. The use of microbore GCC-LC-MS was found to be successful for rapid, sensitive, and simultaneous analysis of high-mannose-type, desialylated fucosyl complex-type, sialylated complex-type, and sialylated fucosyl complex-type oligosaccharide alditols. Furthermore, we demonstrate that this method is applicable to the analysis of carbohydrate heterogeneity in a glycoprotein that possesses diverse oligosaccharides. Microbore GCC-LC-MS was able to characterize high-mannose-type, hybrid-type, and complex-type oligosaccharides in tissue plasminogen activator produced from human melanoma cells in a single analysis.  相似文献   

10.
Chen B  Zhou X  Li C  Wang Q  Liu D  Lin B 《Journal of chromatography. A》2011,1218(14):1907-1912
We herein present a compact disc (CD) microfluidic chip based hybridization assay for phenylketonuria (PKU) screening. This CD chip is composed of a polydimethylsiloxane (PDMS) top layer containing 12 DNA hybridization microchannels, and a glass bottom layer with hydrogel pad conjugated DNA oligonucleotides. Reciprocating flow was generated on the CD chip through a simple rotation-pause operation to facilitate rapid DNA hybridization. When rotated the CD chip, the sample solution was driven into the hybridization channel by centrifugal force. When stopped the CD chip, the sample plug was pulled backward through the channel by capillary force. The hybridization assay was firstly validated with control samples and was then used to analyze 30 clinical samples from pregnant women with suspected PKU fetus. The on-chip DNA hybridization was completed in 15 min with a sample consumption as low as 1.5μL, and the limit-of-detection (LOD) of DNA template was 0.7ng/μL. Among the 30 samples tested, V245V mutation was identified in 4 cases while R243Q mutation was detected in one case. Results of the hybridization assay were confirmed by DNA sequencing. This CD-chip based hybridization assay features short analysis time, simple operation and low cost, thus has the potential to serve as the tool for PKU screening.  相似文献   

11.
Microfluidics has evolved as a major technological platform for biotechnology, material science and related fields. In virtually all of the areas of application, the flowing matrix is an isotropic fluid. However, replacing the typically isotropic fluid with an anisotropic liquid crystal opens up avenues beyond the viscous-dominated isotropic microfluidics. Especially, the material anisotropy of the flowing LC matrix and the consequent incorporation of topological constraints within the microfluidic device offer smart capabilities ranging from tunable flow-shaping to flexible micro-cargo concepts. The key to such capabilities lies in exploiting the possible topological constraints offered by the microfluidic confinement. As an example, we shall demonstrate how long-range ordering and consequent anisotropy in liquid crystals (LCs) could be utilised to devise a novel route to guided transport of microscopic cargo on ‘soft rails’, i.e. topological defect lines (disclinations). We create, position and navigate disclination lines within the LC matrix by tuning the coupling between flow and LC orientation. As model cargo elements, we have used isolated or self-assembled chains of colloidal particles, and demonstrated the broader capability of this method by transporting aqueous droplets on the defect lines. Topological constraints in combination with flow-director coupling thus endow LC microfluidics with features distinct from its isotropic counterparts.  相似文献   

12.
A rapid microanalytical protein-based approach to bacterial characterization is presented. Chip gel electrophoresis (CGE) coupled with LIF detection was used to analyze lysates from different bacterial cell lines to obtain signature profiles of the soluble protein composition. The study includes Escherichia coli, Bacillus subtilis, and Bacillus anthracis (Delta Sterne strain) vegetative cells as well as endospores formed from the latter two species as model organisms to demonstrate the method. A unified protein preparation protocol was developed for both cell types to streamline the benchtop process and aid future automation. Cells and spores were lysed and proteins solubilized using a combination of thermal and chemical lysis methods. Reducing agents, necessary to solubilize spore proteins, were eliminated using a small-scale rapid size-exclusion chromatography step to eliminate interference with down-stream protein labeling. This approach was found to be compatible with nonspore cells (i.e., vegetative cells) as well, not adversely impacting the protein signatures. Data are presented demonstrating distinct CGE protein signatures for our model organisms, suggesting the potential for discrimination of organisms on the basis of empirical protein patterns. The goal of this work is to develop a fast and field-portable method for characterizing bacteria via their proteomes.  相似文献   

13.
Recent studies have demonstrated the need for complementing cellular genomic information with specific information on expressed proteins, or proteomics, since the correlation between the two is poor. Typically, proteomic information is gathered by analyzing samples on two-dimensional gels with the subsequent identification of specific proteins of interest by using trypsin digestion and mass spectrometry in a process termed peptide mass fingerprinting. These procedures have, as a rule, been labor-intensive and manual, and therefore of low throughput. The development of automated proteomic technology for processing large numbers of samples simultaneously has made the concept of profiling entire proteomes feasible at last. In this study, we report the initiation of the (eventual) complete profile of the rat mitochondrial proteome by using high-throughput automated equipment in combination with a novel fractionation technique using minispin affinity columns. Using these technologies, approximately one hundred proteins could be identified in several days. In addition, separate profiles of calcium binding proteins, glycoproteins, and hydrophobic or membrane proteins could be generated. Because mitochondrial dysfunction has been implicated in numerous diseases, such as cancer, Alzheimer's disease and diabetes, it is probable that the identification of the majority of mitochondrial proteins will be a beneficial tool for developing drug and diagnostic targets for associated diseases.  相似文献   

14.
An atmospheric pressure (AP) infrared (IR) laser ionization technique, implemented on a quadrupole ion trap mass spectrometer, was used to analyze underivatized, N-linked oligosaccharides in solution. Experiments were conducted on an atmospheric pressure infrared ionization from solution (AP-IRIS) ion source which differed from previous AP IR matrix-assisted laser desorption/ionization (MALDI) interfaces in that the ion source operated in the absence of an extraction electric field with a higher power 2.94 microm IR laser. The general term 'IRIS' is used as the mechanism of ionization differs from that of MALDI, and is yet to be fully elucidated. The AP-IRIS ion source demonstrated femtomole-level sensitivity for branched oligosaccharides. AP-IRIS showed approximately 16 times improved sensitivity for oligomannose-6 and the core-fucosylated glycan M3N2F over optimal results obtainable on a AP UV-MALDI with a 2,4,6-trihydroxyacetophenone matrix. Comparison between IR and UV cases also showed less fragmentation in the IR spectrum for a glycan with a conserved trimannosyl core, core-substituted with fucose. A mixture of complex, high-mannose and sialylated glycans resulted in positive ion mass spectra with molecular ion peaks for each sugar. Tandem mass spectrometry of the sodiated molecular ions in a mixture of glycans revealed primarily glycosidic (B, Y) cleavages. The reported results show the practical utility of AP-IRIS while the ionization mechanism is still under investigation.  相似文献   

15.
Segmented flow is often used in the synthesis of nanomaterials to achieve narrow particle size distribution. The narrowness of the distribution is commonly attributed to the reduced dispersion associated with segmented flows. On the basis of the analysis of flow fields and the resulting particle size distribution, we demonstrate that it is the slip velocity between the two fluids and internal mixing in the continuous-phase slugs that govern the nature of the particle size distribution. The reduction in the axial dispersion has less impact on particle growth and hence on the particle size distribution. Synthesis of gold nanoparticles from HAuCl(4) with rapid reduction by NaBH(4) serves as a model system. Rapid reduction yields gold nuclei, which grow by agglomeration, and it is controlled by the interaction of the nuclei with local flow. Thus, the difference in the physical properties of the two phases and the inlet flow rates ultimately control the particle growth. Hence, a careful choice of continuous and dispersed phases is necessary to control the nanoparticle size and size distribution.  相似文献   

16.
Time-lapse live cell imaging is a powerful tool for studying signaling network dynamics and complexity and is uniquely suited to single cell studies of response dynamics, noise, and heritable differences. Although conventional imaging formats have the temporal and spatial resolution needed for such studies, they do not provide the simultaneous advantages of cell tracking, experimental throughput, and precise chemical control. This is particularly problematic for system-level studies using non-adherent model organisms such as yeast, where the motion of cells complicates tracking and where large-scale analysis under a variety of genetic and chemical perturbations is desired. We present here a high-throughput microfluidic imaging system capable of tracking single cells over multiple generations in 128 simultaneous experiments with programmable and precise chemical control. High-resolution imaging and robust cell tracking are achieved through immobilization of yeast cells using a combination of mechanical clamping and polymerization in an agarose gel. The channel and valve architecture of our device allows for the formation of a matrix of 128 integrated agarose gel pads, each allowing for an independent imaging experiment with fully programmable medium exchange via diffusion. We demonstrate our system in the combinatorial and quantitative analysis of the yeast pheromone signaling response across 8 genotypes and 16 conditions, and show that lineage-dependent effects contribute to observed variability at stimulation conditions near the critical threshold for cellular decision making.  相似文献   

17.
A microfluidic device was used in tandem with an imidazolium-based ionic liquid to fabricate monodisperse gold nanoparticles (4.38 ± 0.53 nm) with excellent control over size and morphology.  相似文献   

18.
In this paper, a microfluidic chip for the manipulation and capture of cancer cells was introduced, in which the combination of dielectrophoresis (DEP) and a binding method based on chemical interactions by using cell-specific aptamers was performed to enhance the capture strength and specificity. The device has been simply constructed from a straight-channel PDMS placed on a glass substrate that has patterned electrode structures and a self-assembled monolayer of gold nanoparticles (AuNPs). The target cells were transported to the manipulation area by flow and attracted down to the region between the electrodes under the influence of positive DEP force. This approach facilitated subsequent selective capture by the modified aptamers on the AuNPs. The distribution of the electric field in the channel has also been simulated to clarify the DEP operation. As a result, the device has been shown to effectively capture target lung cancer cells with a concentration as low as 2 × 10 4 $2\ \ensuremath{\times{}}\ {10}^{4}\ $ cells/mL. The capture specificity in a sample of mixed cells is up to 80.4%. This technique has the potential to be applied to detection methods for many types of cancer.  相似文献   

19.
Nam SW  Van Noort D  Yang Y  Park S 《Lab on a chip》2007,7(5):638-640
In this study, we introduce a microfluidic device equipped with pneumatically actuated valves, generating a linear gradient of chemoeffectors to quantify the chemotactic response of Tetrahymena pyriformis, a freshwater ciliate. The microfluidic device was fabricated from an elastomer, poly(dimethylsiloxane) (PDMS), using multi-layer soft lithography. The components of the device include electronically controlled pneumatic microvalves, microchannels and microchambers. The linear gradient of the chemoeffectors was established by releasing a chemical from a ciliate-free microchamber into a microchamber containing the ciliate. The ciliate showed chemotactic behaviours by either swimming toward or avoiding the gradient. By counting the number of ciliates residing in each microchamber, we obtained a precise time-response curve. The ciliates in the microfluidic device were sensitive enough to be attracted to 10 pmol glycine-proline, which indicates a 10(5) increase in the ciliate's known sensitivity. With the use of blockers, such as DL-2-amino-5-phosphonopentanoic acid (APPA) or lanthanum chloride (LaCl3), we have demonstrated that the NMDA (N-methyl-d-aspartate) receptor plays a critical role in the perception of chemoeffectors, whereas the Ca2+ channel is related to the motility of the ciliate. These results demonstrate that our microfluidic chemotaxis assay system is useful not only for the study of ciliate chemotaxis but also for a better understanding of the signal transduction mechanism on their receptors.  相似文献   

20.
A precise understanding of individual cellular processes is essential to meet the expectations of most advanced cell biology. Therefore single-cell analysis is considered to be one of possible approach to overcome any misleading of cell characteristics by averaging large groups of cells in bulk conditions. In the present work, we modified a newly designed microchip for single-cell analysis and regulated the cell-adhesive area inside a cell-chamber of the microfluidic system. By using surface-modification techniques involving a silanization compound, a photo-labile linker and the 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer were covalently bonded on the surface of a microchannel. The MPC polymer was utilized as a non-biofouling compound for inhibiting non-specific binding of the biological samples inside the microchannel, and was selectively removed by a photochemical reaction that controlled the cell attachment. To achieve the desired single-macrophage patterning and culture in the cell-chamber of the microchannel, the cell density and flow rate of the culture medium were optimized. We found that a cell density of 2.0 × 10(6) cells/ml was the appropriate condition to introduce a single cell in each cell chamber. Furthermore, the macrophage was cultured in a small size of the cell chamber in a safe way for 5 h at a flow rate of 0.2 μl/min under the medium condition. This strategy can be a powerful tool for broadening new possibilities in studies of individual cellular processes in a dynamic microfluidic device.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号