首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The performance of a monolithic C(18) column (150 mm×0.2 mm i.d.) for multiresidue organic pollutants analysis by in-tube solid-phase microextraction (IT-SPME)-capillary liquid chromatography has been studied, and the results have been compared with those obtained using a particulate C(18) column (150 mm×0.5 mm i.d., 5 μm). Chromatographic separation has been carried out under isocratic elution conditions, and for detection and identification of the analytes a UV-diode array detector has been employed. Several compounds of different chemical structure and hydrophobicity have been used as model compounds: simazine, atrazine and terbutylazine (triazines), chlorfenvinphos and chlorpyrifos (organophosphorous), diuron and isoproturon (phenylureas), trifluralin (dinitroaniline) and di(2-ethylhexyl)phthalate. The results obtained revealed that the monolithic column was clearly advantageous in the context of multiresidue organic pollutants analysis for a number of reasons: (i) the selectivity was considerably improved, which is of particular interest for the most polar compounds triazines and phenyl ureas that could not be resolved in the particulate column, (ii) the sensitivity was enhanced, and (iii) the time required for the chromatographic separation was substantially shortened. In this study it is also proved that the mobile-phase flow rates used for separation in the capillary monolithic column are compatible with the in-valve IT-SPME methodology using extractive capillaries of dimensions similar to those used in conventional scale liquid chromatography (LC). On the basis of these results a new method is presented for the assessment of pollutants in waters, which permits the characterization of whole samples (4 mL) in less than 30 min, with limits of detection in the range of 5-50 ng/L.  相似文献   

2.
A simple and fast capillary chromatographic method has been developed to identify and quantify organic pollutants at sub-ppb levels in real water samples. The major groups of pesticides (organic halogens, organic phosphorous, and organic nitrogen compounds), some hydrocarbons (polycyclic aromatic hydrocarbons), phthalates and some phenols such as phenol and bisphenol A (endocrine disruptors) were included in this study. The procedure was based on coupling, in-tube solid-phase microextraction (IT-SPME) by using a conventional GC capillary column (95% methyl–5% phenyl substituted backbone, 80 cm × 0.32 mm i.d., 3 μm film thickness) in the injection valve to capillary liquid chromatography with diode array detection. A comparative study between the IT-SPME manifold and a column-switching device using a C18 column (35 mm × 0.5 mm i.d., 5 μm particle size) has been performed. The IT-SPME procedure was optimal, it allows reaching limits of detection (LODs) between 0.008 and 0.2 μg/L. No matrix effect was found and recoveries between 70 and 116% were obtained. The precision of the method was good, and the achieved intra- and inter-day variation coefficients were between 2 and 30%. This procedure has been applied to the screening analysis of 28 compounds in whole waters from several points of the Mediterranean coast (Valencia Community, Spain).  相似文献   

3.
This article reports a new procedure for the direct determination of faecal sterols coprostanol and cholesterol in wastewater samples as tracers of human sewage contamination. The method combines in-tube solid-phase microextraction (IT-SPME) for analyte enrichment and capillary liquid chromatography (LC) for separation with diode array detection for identification and quantification. A titania-based polymeric capillary column and a conventional octadecyl silica (ODS) capillary column were evaluated and compared for their ability to separate the analytes. The titania-based column allowed the separation of the analytes in much shorter chromatographic times and with better chromatographic profiles, which in turn resulted in better detectability. In addition, IT-SPME allowed the direct injection into the chromatographic system of sample volumes as large as 200 μL, thus making unnecessary off-line clean-up and concentration steps. In such a way, the tested compounds could be directly analysed in less than 10 min, the limits of detection (LODs) being 10 and 1.2 μg/L for coprostanol and cholesterol, respectively. The reliability of the proposed method was tested by processing several wastewater samples.  相似文献   

4.
建立了全二维气相色谱-飞行时间质谱(GC×GC-TOF MS)分析卷烟主流烟气中中性化学成分的方法。以较长的弱极性柱HP-5MS(50 m×0.2 mm i.d.×0.33μm)作为第一维柱,较短的薄液膜中等极性柱DB-17MS(1.7 m×0.1 mm i.d.×0.1μm)作为第二维柱,对优质烟叶单料卷烟烟气的中性成分进行定性分析,经过人工纠错等分析初步鉴定出匹配度大于700的1 464种成分,重点讨论了中性香味羰基化合物全二维点阵的谱图特征,为烟气和复杂体系的深入研究提供了方法学基础。  相似文献   

5.
Ultra high-performance liquid chromatographic (UHPLC) systems on columns packed with materials ranging from 1.9 to 2.7 μm average particle size were assessed for the fast and sensitive analysis of porphyrins in clinical materials. The fastest separation was achieved on an Agilent Poroshell C(18) column (2.7 μm particle size, 50 × 4.6 mm i.d.), followed by a Thermo Hypersil Gold C(18) column (1.9 μm particle size, 50 × 2.1 mm i.d.) and the Thermo Hypersil BDS C(18) column (2.4 μm particle size, 100 × 2.1 mm i.d.). All columns required a mobile phase containing 1 m ammonium acetate buffer, pH 5.16, with a mixture of acetonitrile and methanol as the organic modifiers for optimum resolution of the type I and III isomers, particularly for uroporphyrin I and III isomers. All UHPLC columns were suitable and superior to conventional HPLC columns packed with 5 μm average particle size materials for clinical sample analysis.  相似文献   

6.
王玉红  刘芳  赵卉  王建民  王彦  阎超 《分析化学》2012,40(10):1622-1626
构建了适用于纳升级到微升级流量的毛细管分离体系的微流蒸发光散射检测器(μELSD),实现了其与毛细管液相色谱(eLC)的联用.对雾化器孔径和雾化毛细管内径、蒸发管内径和长度、光散射池尺寸、雾化毛细管位置和辅助载气流量等参数进行了优化.在最优条件下,微流蒸发光散射检测器检出限为直接进样葡萄糖1 ng(S/N> 10),线性范围0.01~1.0 μg,重复性好,峰面积RSD(n=6)为0.4%,峰高RSD(n=6)为0.3%.本检测器已成功应用cLC-μELSD平台,使用C18毛细管色谱柱(内径250 μm),0.1%甲酸铵溶液(pH 4.5)-甲醇(60∶40,V/V)为流动相,分离检测了3种常用甜味剂,表明本研究构建的系统可以应用于实际分离检测中,具有分析时间快、溶剂消耗量少、样品需求量小的优点.  相似文献   

7.
王晓春  王涵文  马继平  徐烨  关亚风 《色谱》2004,22(2):101-105
首次将填充毛细管高效液相色谱-毛细管气相色谱在线联用技术(μ-HPLC-CGC)用于分离分析八角茴香果实的挥发油成分。液相色谱选用氰基分析柱(250 mm×0.32 mm i.d.),正己烷-乙腈-二氯甲烷(体积比为80∶8∶12)为流动相,对挥发油样品做族组分分离,得到的5个族组分被依次存放在多位储存接口内,然后不分流分别转入毛细管气相色谱仪做详细分析。气相色谱柱由10 m×0.53 mm i.d.保留间隔柱和30 m×0.53 mm i.d.×1.0 μm SE-54分析柱组成。采用了不分流柱内进样模  相似文献   

8.
This paper compares the advantages and disadvantages of two different configurations for the extraction of triazines from water samples: (1) on-fibre solid-phase microextraction (SPME) coupled to conventional liquid chromatography (LC); and (2) in-tube SPME coupled to capillary LC. In-tube SPME has been effected either with a packed column or with an open capillary column. A critical evaluation of the main parameters affecting the performance of each method has been carried out in order to select the most suitable approach according to the requirements of the analysis. In the on-fibre SPME configuration the fibre coating was polydimethylsiloxane (PDMS)-divinylbenzene (DVB). The limits of detection (LODs) obtained with this approach under the optimized extraction and desorption conditions were between 25 and 125 microg/L. The in-tube SPME approach with a C18 packed column (35 mm x 0.5 mm I.D., 5 microm particle size) connected to a switching micro-valve provided the best sensitivity; under such configuration the LODs were between 0.025 and 0.5 microg/L. The in-tube SPME approach with an open capillary column coated with PDMS (30 cm x 0.25 mm I.D., 0.25 microm of thickness coating) connected to the injection valve provided LODs between 0.1 and 0.5 microg/L. In all configurations UV detection at 230 nm was used. Atrazine, simazine, propazine, ametryn, prometryn and terbutryn were selected as model compounds.  相似文献   

9.
For clinical and environmental analyses utilizing capillary gas chromatography/mass spectrometry (GC/MS), increased sensitivity and speed of analysis are highly desirable. These performance advantages are realized using a WCOT column of 100 μm i.d. as compared to the more conventional 200 μm i.d. capillary columns. The improved sensitivity of capillary direct GC/MS with the 100 μm i.d. column for the confirmation of drugs of abuse will be demonstrated. For environmental analysis, the superior efficiency and resolution of the 100 μm i.d. column can be employed for the separation of priority pollutants. This approach is more amenable to capillary direct GC/MS providing a more effective interface to the mass spectrometer. As a result improved sensitivity and a considerable decrease in analysis time is achieved over that obtained with the larger diameter environmental specialty phase columns.  相似文献   

10.
This paper describes a method for the selective screening of organophosphorus pesticides in water. In-tube solid-phase microextraction (SPME) in an open capillary column coupled to capillary liquid chromatography (LC) with UV detection has been used to effect preconcentration, separation and detection of the analytes in the same assembly. For in-tube SPME two capillary columns of the same length and different internal diameters and coating thicknesses have been tested and compared, a 30 cm x 0.25 mm I.D., 0.25 micro m thickness coating column, and a 30 cm x 0.1 mm I.D., 0.1 micro m of coating thickness column. In both columns the coating was 95% dimethylpolysiloxane (PDMS)-5% diphenylpolysiloxane. The proposed methodology provided limits of detections (LODs) for the tested organophosphorus pesticides in the 0.1-10 micro g/L range, whereas the direct injection of the samples onto the capillary LC system provided LODs in the 50-1000 micro g/L range. The sensitivity of the proposed in-tube SPME-capillary LC method is adequate to monitorize the analyte levels in drinking water. Several triazines, polycyclic aromatic hydrocarbons (PAHs), nonylphenol, organochloride pesticides or polybrominated diphenyl ethers (PBDEs) have been evaluated as possible interferents. The reliability of the described method is demonstrated by analysing different real water samples.  相似文献   

11.
考察了烷基酚聚氧乙烯醚在反相色谱、正相键合色谱、硅胶吸附色谱、体积排阻色谱4种不同液相色谱分离模式中的分离效果,分别采用Kromasil C_(18)(250 mm× 4.6 mm,5 μm)、Agilent ZORBAX NH2(250 mm× 4.6 mm,5 μm)、Waters Spherisorb S3W(150 mm×2.0 mm,3 μm)和Shodex MSpak GF-310 2D(150 mm×2.0 mm,5 μm)色谱柱,以225 nm为紫外检测波长,对不同液相色谱分离模式的流动相组成、梯度洗脱条件、柱温、流速等进行了优化,并对烷基酚聚氧乙烯醚在不同液相色谱分离模式中的保留机理进行了初步探讨.结果表明,正相键合色谱实现了烷基酚聚氧乙烯醚的最佳分离;硅胶吸附色谱和体积排阻色谱的分离效果较正相键合色谱稍差.  相似文献   

12.
赵震震  瞿其曙  张欣欣  谷雪  王彦  阎超 《色谱》2009,27(4):431-435
制备了用于色谱的微米纯金颗粒并键合上十八烷基(C18)官能团;对其进行了扫描电镜、红外光谱、元素分析、氮气吸附分析等表征。测得衍生的金颗粒的粒径、孔径以及比表面积分别为3.5 μm、5.0 nm、49.0 m2/g;红外光谱表明C18官能团已键合在金颗粒表面上;衍生后的金颗粒的含碳量为0.56%。通过电填充法得到长度为36 cm(固定相填充长度为19 cm)、内径为100 μm的毛细管色谱柱。利用极端pH的流动相(80%甲醇,pH 1.0以及pH 12.0)冲洗该色谱柱140 h,比较冲洗前后分析物的保留因子,以考察色谱柱的耐酸耐碱性能。结果表明,冲洗前后分析物的保留因子没有明显的变化,说明该色谱柱有良好的耐酸耐碱性。在毛细管液相色谱模式下,用该柱分离尿嘧啶、苯、萘、2-甲基萘、苊以评价色谱柱的一般性能;在碱性条件下分离咖啡因、茶碱、洛贝林以测定色谱柱分离碱性物质的能力。其分离结果表明,该色谱柱的柱效超过了50000理论塔板/m,且色谱峰形较好。在毛细管加压电色谱模式下,施加+5 kV和~5 kV的电压均可以使苯甲酸和苯胺分离,但电场方向不同时,二者的出峰顺序不同。  相似文献   

13.
In trace analysis by capillary GC it is often desirable to use larger than normal injection volumes to obtain sufficient sensitivity. This, however, results in a wider solvent peak and tailing, and may reduce column efficiency. This paper describes the use of a short length of a capillary precolumn coated with a stationary phase of polarity similar to that of the sample solvent and a film thickness greater than that of the analytical column; provided the right combination of polarities of injection solvent and liquid phases are used, the precolumn focuses the solvent band, thereby enabling the maximum injection volume to be increased without measurably reducing efficiency. Typical precolumn dimensions are 1 m length, 0.32 mm i.d., and 0.5 μm stationary phase film thickness. Using a precolumn increases the maximum injection volume up to 8 or 10 μl, or three times that appropriate for a conventional analytical column, with little or no loss in efficiency.  相似文献   

14.
15.
A rapid multiresidue method for the analysis of 72 pesticides has been developed using a single injection with low-pressure gas chromatography/tandem mass spectrometry (LP-GC/MS/MS). The LP-GC/MS/MS method used a short capillary column of 10 m x 0.53 mm i.d. x 0.25 microm film thickness coupled with a 0.6 m x 0.10 mm i.d. restriction at the inlet end. Optimal LP-GC conditions were determined which achieved the fastest separation in MS/MS detection mode. Also MS/MS conditions were optimized in order to increase sensitivity and selectivity. The analytical parameters of the LP-GC/MS/MS method were compared with those obtained by GC/MS/MS using a conventional capillary column (30 m x 0.25 mm i.d. x 0.25 microm film thickness). Better precision and sensitivity values were obtained with the LP-GC/MS/MS approach. The limits of detection (LOD) of the compounds ranged from 0.1 to 14.1 microg L(-1) for LP-GC/MS/MS, lower than those obtained for conventional GC/MS/MS that ranged from 0.1 to 17.5 microg L(-1). The peak widths obtained with the short column in LP-GC are similar to those obtained using conventional capillary GC columns, and the peaks can be successfully identified by MS/MS detection with the conventional scan speed of ion-trap instruments. In addition, the analysis time was significantly reduced with LP-GC/MS/MS (32 min) versus GC/MS/MS (72 min), allowing the number of samples analyzed per day in a routine laboratory to be doubled.  相似文献   

16.
建立了枇杷花中有机氯类农药残留量的固相萃取-毛细管气相色谱(SPE-CGC)分析方法。对采自福建蒲田等12地的枇杷花中六六六(4种异构体)、滴滴涕(4种异构体)、五氯硝基苯共9种有机氯农药的残留量进行了测定。样品采用丙酮超声波提取,浓缩后过Florisil固相萃取小柱净化,洗脱剂为V(正己烷)∶V(丙酮)100∶1。用DB-1701弹性石英毛细管气相色谱柱分离样品,微电子捕获检测器进行检测。9种有机氯农药的峰面积与其质量浓度均有良好的线性关系,相关系数均大于0.999,最低检测限为0.016~0.125μg/L,样品的加标回收率为85.4%~106.9%,相对标准偏差为1.8%~9.8%。该方法能够满足农药残留检测的要求。  相似文献   

17.
A capillary liquid chromatography with UV detection (CLC-UV) system has been developed for determining platinum-based antitumor drugs (e.g., cisplatin, carboplatin, and nedaplatin) in plasma based on the pre-column derivatization of platinum with N,N-diethyl dithiocarbamate (DDTC). The chelated platinum separation was carried out on a capillary column (Inertsil ODS-3, 150 mm × 0.3 mm i.d., 3 μm) using an acetonitrile-water mixture (8:2, v/v) as a mobile phase that flowed at 5.0 μL/min. Detection was carried out by absorbance at 254 nm. Chromatographic peak height was found to be linearly related to the spiked concentration of nedaplatin in the blank control plasma from 5.0 ng/mL to 15 μg/mL (r(2)>0.998). The repeatability (n=5) of the chromatographic peak height for 2.5 μg/mL nedaplatin was 2.6% relative standard deviation (R.S.D.). The CLC-UV system, which required only 20 μL of plasma sample, was applied to the determination of total and free form platinum-based antitumor drugs in plasma after injection into rats. The recovery rates (n=5) of total and free form nedaplatin in plasma were 98% and 99%, respectively, and these repeatability were 2.4% R.S.D. and 3.1% R.S.D., respectively. In addition, the recovery rates (n=5) of total and free form carboplatin in plasma were 99% and 99%, respectively, and these repeatability were 2.9% R.S.D. and 0.24% R.S.D., respectively. The concentration-time profiles of total and free form nedaplatin in rat plasma were monitored to determine the pharmacokinetic parameters.  相似文献   

18.
张宏燕  鲁丹丹  吴利霞  周喆  王升启 《色谱》2008,26(5):540-543
为了进行硫代反义寡核苷酸药物FT19的质量控制研究,建立了用阴离子交换高效液相色谱(AX-HPLC)和毛细管凝胶电泳(CGE)分析自行合成的FT19有关物质的方法。设计合成了FT19的硫代不完全序列(P=O)1和短序列(n-x)并将它们作为已知杂质。在AX-HPLC上,使用的分析柱为DNA Pac PA-100 (4 mm×250 mm);流动相A为10 mmol/L NaOH-0.1 mol/L NaCl,流动相B为10 mmol/L NaOH-3 mol/L NaCl;梯度洗脱条件为流动相B液在8 min内从60%升至100%;流速1 mL/min;柱温40 ℃;检测波长为260 nm。CGE所用毛细管规格为内径100 μm,总长度为31 cm,有效长度为20 cm;电泳缓冲溶液为三羟甲基氨基甲烷(Tris)-硼酸-7 mol/L尿素,pH 8.5;采用电动进样,进样电压-10 kV;分离胶为250 g/L的聚丙烯酰胺;检测波长为254 nm。结果表明,FT19与硫代不完全的(P=O)1序列在AX-HPLC上能够达到基线分离,与短序列(n-1)在CGE上能达到基线分离。说明AX-HPLC和CGE联合应用能够很好地分析FT19中的有关物质。  相似文献   

19.
Cheng H  Yin X  Xu Z  Wang X  Shen H 《Talanta》2011,85(1):794-799
A simple and demountable capillary microflow nebulizer (d-CMN) was developed for inductively coupled plasma mass spectrometry (ICP-MS). It consisted of a nebulizer body, a fused-silica capillary with a tapered tip and a polytetrafluoroethylene (PTFE) adapter. The gas orifice i.d., the solution capillary tip i.d. and its wall thickness were 200, 30, and 5 μm, respectively. The sensitivities, detection limits, precisions and the long-term stability with the d-CMN were evaluated. The experimental results indicated that its performances at low uptake rates were similar or better than those obtained with the conventional concentric nebulizer at 820 μL/min and the micromist nebulizer at 200 μL/min. The demountable construction of the d-CMN permitted that the blocked or broken solution capillary could be conveniently renewed. The low self-aspiration rate (4.77 μL/min) and the analytical characteristics comparable to commercial microflow nebulizers made the d-CMN a good choice for coupling capillary electrophoresis and microbore high-performance liquid chromatograph to ICP-MS. The proposed d-CMN was successfully applied in the iodine speciation by coupling microchip capillary electrophoresis (MCE) to ICP-MS. The absolute detection limits for iodide and iodate of 0.20 and 0.29 fg were achieved with satisfactory resolution.  相似文献   

20.
建立了同时测定秋葵干蔬中脂溶性维生素A、E、K3的反相高效液相色谱法.样品皂化后,采用C18色谱柱(150 mm×4.6 mm,5μm i.d.)进行分离,以甲醇为流动相,流速1.0 mL/min,二极管阵列检测器(DAD)在325、290、244 nm波长下同时检测,外标法定量.结果表明,脂溶性维生素A、E、K3在0...  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号