首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) method was developed and validated to determine 90 pesticides in apple samples. MS/MS data acquisition was achieved by applying multiple-reaction monitoring of 2 fragment ion transitions to provide a high degree of sensitivity and selectivity for both quantitation and confirmation. Matrix-matched standard calibration curves with the use of isotopically labeled standards (or a chemical analog) as internal standards were used to achieve the best accuracy for the method. Both a conventional method validation procedure and a designed experiment were applied to study the accuracy and precision of the method. A compiled computer program that provided a semiautomated procedure for handling a large number of calculations was used to calculate the overall recovery, intermediate precision, and measurement uncertainty (MU). In general, the overall recoveries from samples spiked at levels of 10, 50, and 80 microg/kg, ranged from 60.8 to 121.1%, intermediate precision was <10%, and MUs were <30%. Poor accuracy and/or repeatability was observed for pyridate and etofenprox. The method limits of detection based on a signal-to-noise ratio of >3 were usually <1 microg/kg (ppb), except those for aldicarb sulfoxide and pyridaphenthion, which were about 5 microg/kg.  相似文献   

2.
液相色谱-电喷雾串联质谱法测定生姜中的215种农药残留   总被引:4,自引:1,他引:4  
曹静  庞国芳  王明林  范春林 《色谱》2010,28(6):579-589
建立了生姜中215种农药多残留测定的液相色谱-电喷雾串联质谱(LC-ESI-MS/MS)方法。样品用1%醋酸-乙腈溶液均质提取,经Sep-Pak Vac固相萃取柱净化,乙腈-甲苯(3:1, v/v)洗脱,旋转蒸发浓缩至约0.5 mL后,于室温氮气吹干,用乙腈-水(3:2, v/v)溶解,以电喷雾电离串联质谱在正离子多反应监测(MRM)模式下进行测定。在定量限水平进行添加回收率实验,方法的回收率范围为68.1%~132.6%,其中回收率在70%~120%的占94.4%,相对标准偏差(RSD)范围为0.4%~25.0%。方法的检出限(S/N=3)和定量限(S/N=10)范围分别为0.01~70.45 μg/L和0.04~234.84 μg/L。该方法操作简便,灵敏度、准确度和精密度均符合农药多残留检测技术要求,适用于生姜中215种农药多残留的快速测定。  相似文献   

3.
建立了婴幼儿配方奶粉中维生素D的液相色谱-大气压化学电离串联质谱(LC-APCI-MS/MS)分析方法。样品经正己烷和甲基叔丁基醚混合溶液提取,ProElut VDC固相萃取柱净化,Kinetex C_(18)色谱柱分离,采用大气压化学电离(APCI)源、正离子扫描和多反应监测(MRM)模式对维生素D_2和维生素D_3进行检测,内标法定量。结果表明维生素D_2和维生素D_3在5~5 000μg/L范围内均具有良好的线性关系,检出限为2μg/kg,定量限为5μg/kg。在5、10和100μg/kg添加水平下,维生素D_2和维生素D_3的回收率为85.2%~105.3%,相对标准偏差为4.7%~8.1%。该方法简便准确,灵敏度高,适用于婴幼儿奶粉中维生素D的测定。  相似文献   

4.
A liquid chromatographic/tandem mass spectrometric method using pneumatically assisted electrospray ionization (LC-ESI-MS/MS) was developed for determination of N-acetylneuramic acid and N-glycolylneuramic acid in infant formula. Reconstituted samples were hydrolysed in dilute sulfuric acid and deproteinized with acetonitrile. The extract was analysed directly without further clean-up by hydrophilic interaction chromatography. The substances were detected in negative ion mode and matrix matched standards were used for calibration. The relative intra-laboratory reproducibility standard deviation was better than 6% for both substances. An R2 of 0.985 was obtained by comparison with a classical colorimetric assay based on reaction with resorcinol. The developed method is expected to be applied for accurate routine analysis of infant formulas.  相似文献   

5.
6.
Fragmentation pathways of five iridoid glycosides have been studied by using electrospray ionization multi-stage tandem mass spectrometry (ESI-MS(n)). The first-stage MS data of the five iridoid glycosides were compared. The MS spectra showed that the adduct ions of iridoid glycosides and the formate anion were diagnostic ions to distinguish iridoid glycosides with a carboxyl group at the C-4 position or an ester group at the C-4 position. The MS fragmentation pathways of the five iridoid glycosides were also studied. Analyzing the product ion spectra of iridoid glycosides, some neutral losses were observed, such as H(2)O, CO(2) and glucose residues, which were very useful for the identification of the functional groups in the structures of iridoid glycosides. Furthermore, specific loss of one molecule of methyl 3-oxopropanoate or 3-oxopropanic acid was firstly discussed, which corresponded to the isomerization of the hemiacetal group in the structure of iridoid aglycone. According to the fragmentation mechanisms and HPLC/MS(n) data, the structures of five iridoid glycosides in a crude extract of Gardenia jasminoisdes fruit have been identified. Three compounds were compared with standards and the other two were identified as shanzhiside and genipin gentibioside by their MS(n) data without standard compounds. In order to further validate the veracity of the deduction, genipin gentiobioside was isolated from the extract of Gardenia jasminoisdes fruit using Purification Factory and was further identified by C- and H-NMR.  相似文献   

7.
Liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) is one of the most prominent analytical techniques owing to its inherent selectivity and sensitivity. In LC/ESI-MS/MS, chemical derivatization is often used to enhance the detection sensitivity. Derivatization improves the chromatographic separation, and enhances the mass spectrometric ionization efficiency and MS/MS detectability. In this review, an overview of the derivatization reagents which have been applied to LC/ESI-MS/MS is presented, focusing on the applications to low molecular weight compounds.  相似文献   

8.
A comprehensive analytical method based on liquid chromatography electrospray ionization tandem mass spectrometry (LC–ESI–MS/MS) with negative ionization mode has been developed for measuring of alkylphenols and bisphenol A in beverage samples. Concentration and clean up of samples were performed on 200 mg OASIS HLB solid extraction cartridges. The effects of mobile phases and additives on ionization were assessed. The recoveries for each compound ranged from 76.7 to 96.9% and reproducibilities were represented as having relative standard deviation (R.S.D.) below 10%. The limits of quantification (LOQ) of the method under multiple-reaction monitoring (MRM) acquisition mode were 0.04, 0.03 and 0.2 ng L−1 for 2 L of mineral drinking water and 2.0, 1.8 and 8.0 ng L−1 for 50 mL of soda beverages.  相似文献   

9.
A rapid analytical method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) using electrospray ionization in negative ion detection mode was developed for the analysis of underivatized iodoacetic acid in water. The method was applied to model reaction mixtures in the study of the formation of iodoacetic acid after chlorinated tap water was boiled in the presence of potassium iodide or iodized table salt. Samples can be directly analyzed by the LC/MS/MS system without extraction or chemical derivatization. Limit of detection was determined to be 0.3 microg/L (or 0.3 ng/mL) and limit of quantitation was about 1 microg/L (1 ng/mL).  相似文献   

10.
A rapid, selective and sensitive liquid chromatography/tandem mass spectrometry (LC‐MS/MS) method was developed and validated for determining bencycloquidium bromide (BCQB) in beagle dog plasma. The plasma sample was deproteinized with methanol which contained l‐ethyl‐bencycloquidium bromide as internal standard, and supernantant was assayed by LC‐MS/MS. The chromatographic separation was performed on a Phenomenex C18 column (100 × 2.0 mm, i.d., 3.0 μm) with a gradient programme mobile phase consisting of methanol and ammonium acetate (5 mm) containing 0.15% acetic acid and at a flow rate of 0.3 mL/min. Electrospray ionization in positive ion mode and selective reaction monitoring was used for the quantification of BCQB with a monitored transitions m/z 330.2 → 142.1 for BCQB and m/z 344.2 → 126.2 for IS. Validation results indicated that the lower limit of quantification was 0.05 ng/mL and the assay exhibited a linear range of 0.05–10.0 ng/mL and gave a correlation coefficient of 0.9998. The intra‐ and inter‐run precisions of the assay were 1.7–4.6 and 3.2–15.6%, respectively, and the intra‐ and inter‐day accuracies were ?8.8 to 1.1 and ?5.0 to 4.6%, respectively. The developed method was applied for the pharmacokinetic study of BCQB in beagle dogs following a single intranasal dose. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
建立了高效液相色谱-串联质谱法(LC/MS/MS)测定纺织品中致癌芳香胺的检测方法.纺织品中的偶氮染料在柠檬酸缓冲液中用连二亚硫酸钠还原为芳香胺,用硅藻土提取还原液中的芳香胺,用乙醚洗脱,浓缩至近干后用甲醇定容.使用液相色谱-串联质谱进行测定,色谱柱为XTerra MS C18柱,流动相为甲醇和0.025 mol/L乙...  相似文献   

12.
Tomato (Lycopersicon esculentum Mill.) is the second most important fruit crop worldwide. Tomatoes are a key component in the Mediterranean diet, which is strongly associated with a reduced risk of chronic degenerative diseases. In this work, we use a combination of mass spectrometry (MS) techniques with negative ion detection, liquid chromatography/electrospray ionization linear ion trap quadrupole‐Orbitrap‐mass spectrometry (LC/ESI‐LTQ‐Orbitrap‐MS) and liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) on a triple quadrupole, for the identification of the constituents of tomato samples. First, we tested for the presence of polyphenolic compounds through generic MS/MS experiments such as neutral loss and precursor ion scans on the triple quadrupole system. Confirmation of the compounds previously identified was accomplished by injection into the high‐resolution system (LTQ‐Orbitrap) using accurate mass measurements in MS, MS2 and MS3 modes. In this way, 38 compounds were identified in tomato samples with very good mass accuracy (<2 mDa), three of them, as far as we know, not previously reported in tomato samples. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
A specific, sensitive, rapid and reproducible method for the determination of flomoxef in human plasma using high‐performance liquid chromatography–tandem mass spectrometry was developed and validated. Flomoxef was detected using an electrospay ionization method operated in negative‐ion mode. Chromatographic separation was performed in gradient elution mode on a Luna® C18(2) column (3 μm , 20 × 4.0 mm) at a flow rate of 1 mL/min and runtime 3.5 min. The mobile phase consisted of acetonitrile and water containing 0.1% formic acid as additive. Extraction of flomoxef from plasma and precipitation of plasma proteins was performed with acetonitrile with an absolute recovery of 86.4 ± 1.6%. The calibration curve was linear with a correlation coefficient of 0.999 over the concentration range 10–5000 ng/mL and the lower limit of quantification was 10 ng/mL. The intra‐ and inter‐day precisions were <11.8%, while the accuracy ranged from 99.6 to 109.0%. A stability study of flomoxef revealed that it could be successfully analyzed at 4ºС over 24 h, but it was unstable in solutions at room temperature during short‐term storage (4 h) and several freeze–thaw cycles. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
A rapid and sensitive ultra-performance liquid chromatography–tandem mass spectrometry method with electrospray ionization (UPLC–ESI–MS/MS) for analysis of B-group vitamins in honey has been presented. Aim of this study is the characterization of different types of Turkish honeys according to B-group vitamins. Vitamins were determined in 17 different types of Turkish honey samples by UPLC–ESI–MS/MS. Heather honey samples were distinguished among the studied honeys with the richest vitamin content with 286.10?mg/kg, and it is followed by sunflower honey and thyme honey with the total vitamin contents of 206.01 and 163.27?mg/kg, respectively. The presence of vitamin B1 (thiamine), vitamin B2 (riboflavin), vitamin B3 (nicotinamide, B3N and nicotinic acid, B3H), vitamin B6 (pyridoxine), and vitamin B9 (folic acid) was detected in all the honey samples analyzed. Moreover, vitamin B5 (pantothenic acid) was observed in most of them. Vitamin B12 (cyanocobalamin) and vitamin B7 (biotine) were not detected in the studied honey samples. Turkish honey samples showed efficacious vitamin content for the consumers.  相似文献   

15.
Aripiprazole is an important antipsychotic drug. A simple, sensitive and rapid ultra‐performance liquid chromatography/electrospray ionization tandem mass spectrometry (UPLC‐ESI‐MS/MS) method was developed and validated for the simultaneous quantification of this compound in rat plasma and brain homogenate. The analyte was extracted from rat plasma and brain homogenate using a weak cation exchange mixed‐mode resin‐based solid phase extraction. The compound was separated on an Agilent Eclipse Plus C18 (2.1 × 50 mm, 1.8 µm) column using a mobile phase of (A) 0.1% formic acid aqueous and (B) acetonitrile with gradient elution. The analyte was detected in positive ion mode using multiple reaction monitoring. The method was validated and the specificity, linearity, limit of quantitation (LOQ), precision, accuracy, recoveries and stability were determined. The LOQ was 0.5 ng/mL for aripiprazole in plasma and 1.5 ng/g in brain tissue. The MS response was linear over the concentration range 0.5–100 ng/mL for aripiprazole in plasma and 1.5–300 ng/g in brain tissue. The precision and accuracy for intra‐day and inter‐day were better than 14%. The relative and absolute recoveries were above 72% and the matrix effects were low. This validated method was successfully used to quantify the rat plasma and brain tissue concentrations of the analyte following chronic treatment with aripiprazole. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
This paper describes a selective and sensitive method that uses liquid chromatography/tandem mass spectrometry with positive electrospray ionization (ESI+) for the determination of deltamethrin in a variety of crops. Samples were extracted by conventional high-speed blending. Some samples required no further cleanup; others were cleaned up by gel permeation chromatography, strong cation-exchange cartridges, or partitioning with n-hexane. In the determinative step, the buffered neutral mobile phase, consisting of 10 mM ammonium acetate (pH 6.8) and methanol, and ESI+ provided strong ammonium adduct formation to [M+NH4]+ at m/z 523, and the multiple-reaction monitoring (MRM) transition at m/z 523/281 was used for the quantitation of deltamethrin. A second MRM transition at m/z 525/283 was used for confirmation. The limit of quantitation (LOQ) values were 0.01 mg/kg for edible materials and 0.05 mg/kg for nonedible materials. Mean overall recoveries at the LOQ and the 10-fold LOQ ranged from 73 to 96%, and the relative standard deviations were <10% for all samples materials analyzed.  相似文献   

17.
A new analytical method based on liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) is proposed and validated for the identification and quantification of alkyl alkylphosphonic acids (AAPAs) in aqueous matrices. Retrospective detection and identification of degradation products of chemical warfare agents is important as an indicator of possible use of chemical warfare agents or of environmental contamination. A commercially available solution of 1,9‐nonanediyl‐bis‐(3‐methylimidazolium)bisfluoride (NBMI) allowed detection of AAPAs by positive mode electrospray ionization mass spectrometry by forming an adduct with AAPAs. MS/MS experiments using an ion trap analyzer were carried out for unambiguous identification of AAPAs. Different parameters were optimized in order to obtain both an adequate chromatographic separation and a high sensitivity using experimental design methodology. Quantification was done with matrix‐matched calibration standards of AAPAs. The method was validated in terms of linearity (r2 >0.982), intra‐ and inter‐day precisions (RSD below 15%), and robustness. The method is sensitive enough for the determination of AAPAs in aqueous matrices, with limits of detection in the 1–5 ng mL–1 range and limits of quantification in the 5–20 ng mL–1 range. Finally, the method was successfully applied to determine these AAPAs in aqueous samples provided by the Organization for the Prohibition of Chemical Weapons during 26th and 29th official proficiency tests. The added advantage of this method is identification of low mass range analyte at high mass range, which obviates the background noise at low mass range. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
Sorbic acid (SA: CH(3)-CH=CH-CH=CH-COOH) and its salts are widely used as preservatives in foodstuff because of their growth inhibitory effects on mold, yeast and a wide range of bacteria. However, it is still unclear whether SA and its salts are actually incorporated in these organisms and a higher organisms like mammalian cells. Acidic compounds such as SA are usually analyzed by HPLC with eluents containing acetic acid, formic acid and their ammonium acetates, but such acidic buffers may suppress the ionization efficiency of the acidic compounds in negative-mode electrospray ionization (ESI). In this study, we present a sensitive and simple method for analysis of SA by HPLC with non-acidic solvents such as CH(3)CN/CH(3)OH-H(2)O by negative ion mode ESI-LC/MS. As a result, SA at less as 30 fmol was selectively determined by the selected reaction monitoring (SRM) mode. It was defined as the peak area with a signal-to-noise ratio (S/N) of 3. Good linearity was obtained in the range from 55 fmol (S/N 3) to 500 fmol (r(2)=0.9968) for SA by using LC/MS with the SRM mode. We also show that the method is useful to analyze SA level in the cytosol of mastocytoma cells, which were pretreated with SA. These results suggest the applicability of this method for the highly sensitive determination of SA in the mammalian tissues and cells.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号