1.
An HPLC method was developed for the simultaneous determination of gnaphaliin A and B, active compounds of Gnaphalium liebmannii Sch. Bp ex Klatt. The HPLC separation was performed on an Inertsil ODS-3 (150 x 4.6 mm id, 5 microm) RP C18 column operated at 40 degrees C; the isocratic mobile phase was 0.02% aqueous orthophosphoric acid-methanol-acetonitrile (50 + 30 + 20, v/v/v), with a run time of 20 min and flow rate of 1.5 mL/min. Detection with a photodiode array detector (PDAD) was at 270 nm. The method was validated for linearity, repeatability, LOD, and LOQ. The LOD and LOQ for gnaphaliin A and B were found to be in the range of 0.4-0.5 and 1.0-1.4 microg/mL, respectively. This is the first report of an analytical method developed for the quantitative analysis of flavones from Gnaphalium species by HPLC-PDAD with applications for raw material and commercial products.  相似文献   

2.
A simple and sensitive reverse phase HPLC method for the determination of adapalene (ADP) in bulk drug samples and pharmaceutical formulations has been developed and validated. The separation of ADP was achieved on an Inertsil ODS-3V (5 ??m, 15 cm ± 4.6 mm i.d.) column using UV detector at 230 nm. The mobile phase consisted of ammonium acetate (25 mM, pH 3.0), methanol and tetrahydrofuran (18: 42: 40 v/v). The linear range of detection was 2?C200 ??g/mL (R = 0.9991). Intra- and inter-day assay relative standard deviation values were less than 0.5%. The method has been successfully applied to the determination of ADP in pharmaceutical preparations. The excipients commonly present in formulations did not interfere with the assay of ADP. Analytical parameters were calculated and complete statistical evaluation was performed.  相似文献   

3.
A new method for determining the optical impurity of Pregabalin is developed. The method is based on Pregabalin, and its isomers can be derivatized with Na-5-fluoro-2,4-dinitrophenyl-5-L-alanine amide. These derivated compounds can be separated by an ordinary chromatography column (Inertsil ODS-2.5 microm, 250 mmx4.6 mm i.d.). Phosphoric acid buffer and acetonitrile (55:45, v/v) are used as mobile phase and 1.0 mL/min flow rate at room temperature. The detective wavelength is fixed at 340 nm. The results indicate that the limit of detection of R model optical impurity 1.1x10(-8) g/mL (signal-to-noise=3), accuracy, and repeatability is satisfied. Therefore, the method can be used for the quality control of Pregabalin.  相似文献   

4.
高效液相色谱-质谱法分析菊芋叶中的绿原酸类化合物   总被引:4,自引:0,他引:4  
建立了菊芋叶中绿原酸类化合物的高效液相色谱-紫外检测-质谱(HPLC-UV-MS)定性分析方法。液相色谱条件:Inertsil ODS-3色谱柱(250 mm×4.6 mm,5 μm);甲醇和水(含1%乙酸)梯度洗脱,流量1.0 mL/min;柱温35 ℃;检测波长327 nm。质谱条件:Thermo公司TSQ三级四极杆质谱仪;电喷雾电离(ESI)接口;负离子检出模式。采用该方法得到了菊芋叶提取物的紫外检测的色谱图、负离子监测的总离子流图以及相应色谱峰的紫外光谱图和一级、二级质谱图,对其进行解析,鉴别出菊芋叶中的7个绿原酸类成分。该方法简便、快速、灵敏度高,可以很好地对菊芋叶中的绿原酸类化合物进行定性分析。  相似文献   

5.
An evaporative light scattering detection (ELSD) based high-performance liquid chromatography (HPLC) method is developed for the determination of polysorbate 80 (tween 80) in therapeutic protein formulations. The method is simple and overcomes the difficulties associated with specificity and sensitivity. The method is suitable for the quantitation of polysorbate 80 in the usual formulation range (0.01-0.1%) as well as in trace amounts ≥13 μg/mL. The analysis is based on the removal of protein first by solid-phase extraction using Oasis HLB cartridges followed by HPLC analysis using Inertsil ODS-3 C 18 column (4.6×150 mm, 5 μm) using reversed-phase conditions. The detector response changes exponentially with an increase in polysorbate concentration. A very good linear fit of log ELSD response against log polysorbate 80 concentration is observed. The specificity, sensitivity, precision, and accuracy of the method are suitable for the quantitation of polysorbate 80 in protein formulations.  相似文献   

6.
A new analytical method for the simultaneous determination of seven fluoroquinolones, namely, norfloxacin, ciprofloxacin, danofloxacin, enrofloxacin, orbifloxacin, sarafloxacin, and difloxacin, especially in dark-colored honey, has been developed. Fluoroquinolone antibiotics were extracted from samples with MacIlvaine buffer solution (pH 4.0) containing EDTA disodium salt dihydrate. The extracts were treated with both a polymeric cartridge and a metal chelate affinity column preloaded with ferric ion (Fe3+). LC separation with fluorescence detection was performed at 40 degrees C using an Inertsil ODS-4 analytical column (150 x 4.6 mm, 3 microm). The mobile phase was composed of 20 mM/L citrate buffer solution (pH 3.1)-acetonitrile mixture (70 + 30, v/v) containing 1 mM/L sodium dodecyl sulfate. Lomefloxacin was used as an internal standard. The developed method was validated according to the criteria of European Commission Decision 2002/657/EC. Decision limits and detection capabilities were below 2.9 and 4.4 microg/kg, respectively.  相似文献   

7.
A rapid, accurate and reliable reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of naproxen and its photodegradation products in methanol was developed and validated. An Inertsil 5-ODS-3V column (5 microm, C18, 250 x 4.6 mm i.d.) was used with a mobile phase of acetonitrile-methanol-1% HOAc in H2O (40:20:40, v/v/v). UV detection was set at 230 nm. The developed method satisfies system suitability criteria, peak integrity and resolution for the parent drug and its photoproducts. The intraday and interday standard deviations of five replicate determinations for five consecutive days at the working concentrations of 5.0, 10, 25, 50, and 100 microm were 0.23-0.98 with coefficients of variance (CVs) of between 0.96 and 4.56% for the former, and 0.14-1.15 with CVs of between 1.13 and 3.82% for the latter. The percentage recoveries were determined to be 98.34, 99.19, 100.18, 102.97 and 99.81%, respectively, at the five concentrations between 5.0 and 100 microm. The limit of quantitation of naproxen was determined to be 0.29 microg/mL, while the detection limit was 64 ng/mL. Four major photoproducts were observed from the HPLC chromatogram using a Panchum PR-2000 reactor which equipped with 8 W x 16 low-pressure quartz mercury lamps as the light source for irradiation of a naproxen sample in methanol. The structures of the photoproducts were confirmed by LC-ESI MS.  相似文献   

8.
A validated stability indicating RP‐HPLC assay of gemifloxacin mesylate was developed by separating its related substances on an Inertsil‐ODS3V‐C18 (4.6 × 250 mm; 5 μm) column using 0.1% trifluoroaceticacid (pH 2.5) and methanol as a mobile phase in a gradient elution mode at a flow rate of 1.0 mL/min at 27°C. The column effluents were monitored by a photodiode array detector set at 287 nm. The method was validated in terms of accuracy, precision and linearity as per ICH guidelines. Forced degradation of gemifloxacin (GFX) was carried out under acidic, basic, thermal, photolysis and peroxide conditions and the degradation products were separated and characterized by ESI‐MS/MS, 1H and 13C NMR spectroscopy. The method was successfully applied to the analysis of bulk drugs and the recoveries of gemifloxacin and impurities were in the range of 97.60–102.90 and 96.99–102.10%, respectively. No previous reports were found in the literature on identification of degradation products of gemifloxacin. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
A solution of carprofen in methanol at a concentration of 2.74 x 10(-2) mg/mL is subjected to photoirradiation using a Hanovia 200-W high-pressure Hg lamp for 9 h. In total, seven photodegradation products are separated, and their quasimolecular ions are subsequently determined online using a liquid chromatography (LC)-electrospray ionization (ESI)-mass spectrometry (MS) method. The high-performance LC consists of an Inertsil 5 ODS-80A (2.1- x 150-mm) column. The mobile phase is initially CH(3)CN. NH(4)OAc (20mM in de-ionized H(2)O) is 43:57 (v/v), and after 14 min it is CH(3)CN. NH(4)OAc (20mM in de-ionized H2O) is 54: 46 (v/v). The UV detector was set at 260 nm. The parameters of LC-MS for mass determination involves an atmospheric pressure ionization electron spray interface with a negative mode of polarity (ESI(-)). The chemical structures of the degradants are elucidated based on the mass-to-charge ratio of the quasimolecular ions and the molecular weight changes by comparison with the parent drug (carprofen). The degradation proceeds via an initial dechlorination. A dechlorination or esterification reaction is competed with decarboxylation. This finding is in accordance with our previously reported result of first order photodecomposition kinetics for carprofen.  相似文献   

10.
高效液相色谱法同时测定扁桃仁中的水溶性维生素C,B1,B2和B6   总被引:16,自引:0,他引:16  
申烨华  张萍  孔祥虹  郭春会  王继武 《色谱》2005,23(5):538-541
建立了用高效液相色谱同时测定扁桃仁中4种水溶性维生素C,B1,B2和B6的方法。以酸水解法处理样品,在Inertsil ODS-3柱(25 cm×4.6 mm i.d., 5.0 μm)上,以0.05 mol/L KH2PO4 (pH 6.0)-甲醇(体积比为70∶30)为流动相进行等度洗脱,检测波长265 nm条件下,对陕西蒲城扁桃仁中的水溶性维生素C,B1,B2和B6的含量进行了同时测定。4种水溶性维生素在其质量浓度为5.0~50 mg/L时线性良好(r=0.9990~0.9997);添加水平为5.0~20.0 mg/kg时,平均回收率为91.77%~99.30%,相对标准偏差(n=3)为0.31%~1.98%。测得陕西蒲城产扁桃仁中维生素B2的含量为4.27~4.53 mg/kg,维生素B1的含量为0.799~0.838 mg/kg,未检出维生素C和维生素B6。该法简便、快速,准确性和重现性均较好,对果仁中水溶性维生素的测定具有一定的参考价值。  相似文献   

11.
A reversed-phase high-performance liquid chromatographic method for simultaneous separation and determination of citalopram hydrobromide and its process impurities in bulk drugs and pharmaceutical formulations was developed. The separation was accomplished on an Inertsil ODS 3V (250x4.6 mm; particle size 5 mum) column using 0.3% diethylamine (pH = 4.70) and methanol/acetonitrile (55:45 v/v) as mobile phase in a gradient elution mode. The eluents were monitored by a photodiode array detector set at 225 nm. The chromatographic behavior of all the related substances was examined under variable conditions of different solvents, buffer concentrations, and pH. The method was validated in terms of accuracy, precision, and linearity. The method could be of use not only for rapid and routine evaluation of the quality of citalopram in bulk drug manufacturing units but also for the detection of its impurities in pharmaceutical formulations. Three unknown impurities were consistently observed during the analysis of different batches of citalopram. Forced degradation of citalopram was carried out under thermal, photo, acidic, alkaline, and peroxide conditions. The degradation products and unknown impurities were isolated and characterized by ESI-MS/MS, (1)H NMR, and FT-IR spectroscopy.  相似文献   

12.
Chromatographic separation of lenalidomide and its impurities was achieved on an Inertsil ODS-3 V column using a mobile phase consisting of a mixture of buffer, acetonitrile and methanol in the ratio 80:8:12 v/v. Degradation studies were performed on bulk samples of lenalidomide subjected to 0.5 N hydrochloric acid, 0.5 N sodium hydroxide, 10% v/v hydrogen peroxide, heating to 60 °C and UV light at 254 nm. Degradation was observed only under base hydrolysis conditions. The developed LC method gave a mass balance close to 99.5%, proving it to be suitable for stability studies and was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

13.
A simple and rapid reversed-phase high-performance liquid-chromatographic method for the separation and determination of process-related impurities of celecoxib (CXB) in bulk drugs and pharmaceuticals was developed. The separation of impurities viz., 4-methylacetophenone (I), 1-(4-methylphenyl)-4,4,4-trifluorobutane-1,3-dione (II), 4-hydrazinobenzene sulfonamide (III) and a regio-specific isomer [3-(4-methylphenyl)-5-trifluoromethyl-1H-pyrazole-1-yl]-benzenesulfonamide (IV), was accomplished on an Inertsil ODS-3 column dynamically coated with 0.1% hexamethyldisilazane (HMDS) in acetonitrile:water (55:45 v/v) as a mobile phase and detection at 242 nm using PDA at ambient temperature. The chromatographic conditions were optimized by studying the effects of HMDS, an organic modifier, time of silanization and column temperature. The method was validated and found to be suitable not only for monitoring the synthetic reactions, but also to evaluate the quality of CXB.  相似文献   

14.
A rapid method for the isolation and high-performance liquid chromatographic (HPLC) determination of sulfamethazine (SMZ) in pork tissues (kidney, liver, and muscle) without using organic solvents is developed. The isolation is performed by homogenization with an acid solution using an ultrasonic-homogenizer, followed by centrifugation. The HPLC analyses are performed using a reversed-phase C(4) column (150- x 4.6-mm i.d.), a mobile phase of 0.02 mol/L citric acid solution, and a photodiode array detector. The resulting HPLC chromatograms are free from interferences for determination and identification. The proposed technique is shown to be linear (r > 0.99) over the concentration range 0.1-2.0 microg/g for all pork tissues. Average recoveries of SMZ (spiked 0.1-2.0 microg/g) range from 87.6% to 90.2%, with inter- and intra-assay variabilities of less than 4%. The total time required for the analysis of one sample and limit of quantitation is less than 20 min and 0.09 microg/g, respectively.  相似文献   

15.
4-(2-Pyridylazo) resorcinol (PAR) and citrate were used as pre-column complexing agents for the determination of Nb(V) and Ta(V) as ternary complexes in geological samples. Aliquots of 2 ml of the standard and sample solutions containing the Nb(V) and Ta(V) complexes were loaded onto a concentrator column (C18, 0.4 cm x 4.6 mm) with a carrier mobile phase comprising 20% (v/v) methanol and containing 5 mM acetic acid, 5 mM citric acid and 10 mM tetrabutylammonium bromide (TBABr), pH 6.5 at 2 ml/min for 2 min, with the effluent being directed to waste. An automatic switching valve was then switched to flush both complexes from the concentrator column onto a C18 analytical column using a mobile phase comprising 32% (v/v) methanol and containing 5 mM acetic acid, 5 mM citric acid and 3 mM TBABr, pH 6.5 for 2.5 min. The switching valve was then switched back to the original position, and cleaned with methanol for 7 min to eliminate unwanted species still adsorbed to the concentrator column. This procedure prevented later eluting compounds from reaching the analytical column, which reduced the overall run time. The detection limits of Nb(V) and Ta(V) (determined at a signal-to-noise ratio of 3, detection wavelength of 540 nm and a 2-ml sample volume) were 0.012 and 0.039 ppb for Nb(V) and Ta(V), respectively. Recoveries of Nb(V) and Ta(V) were 99.4 and 96.2%, respectively. The HPLC results obtained from the reference granite and basalt samples agreed well with inductively coupled plasma MS and certified values, but the HPLC method yielded slightly low values of the Nb/Ta ratio.  相似文献   

16.
The potential of high-speed analyses by rapid resolution liquid chromatography (RRLC) and RRLC/MS on 1.8-microm porous particles packed into short columns operated at high flow-rate was investigated and compared with the performance of 5-microm porous particles packed into conventional columns. Using similar chemistries, the ease of conversion from conventional HPLC to an RRLC method was demonstrated. In order to display the practicality of RRLC separations, the analysis of pesticides in crops and catechins in Japanese green tea was selected. Using the Japanese Food Hygiene Law method, which employs a conventional 5-microm RP column (250 mm x 4.6 mm) for quantification of pesticides in crops, the analysis time was 25 min under isocratic conditions. Using the RRLC method on the short (50 mm x 4.6 mm) column packed with 1.8-microm porous particles, the same separation could be performed in 0.8 min with the RRLC/MS method without a loss in resolution. At the highest flow rate, compared to the conventional method, the time could be reduced by a factor of 31. In gradient elution, the fastest separation of catechins in Japanese green tea was achieved by RRLC on 50-mm x 4.6-mm id or 50-mm x 2.1-mm id RRLC columns packed with 1.8-microm particles. The analysis time at 5 mL/min was less than 1 min. Compared to the conventional HPLC method on a 150-mm column packed with 5-microm particles, time was reduced by a factor of 15. The effect of other experimental parameters such as the column temperature, acquisition rate of the detector and the influence of cell volume on chromatographic performance was also investigated. After the optimization, the analysis precision under the fastest RRLC conditions was examined. RSDs of retention time and peak area were 0.2% and 0.47%, respectively.  相似文献   

17.
高效液相色谱柱后衍生测定鸡组织中甲基盐霉素残留量   总被引:2,自引:0,他引:2  
建立了鸡组织中甲基盐霉素的高效液相色谱柱后衍生化分析方法.样品经异辛烷提取,离心后上层有机相过硅胶固相萃取小柱,洗脱液浓缩后用V(甲醇)∶ V(水)=90∶ 10混合液溶解.采用Inertsil ODS-3 C18柱,以V(甲醇): V(乙酸)∶ V(水)=94∶ 3∶ 3为流动相,香草醛为衍生剂进行高效液相色谱柱后衍生分析,520 nm检测,外标法定量.方法检出限为6 μg/kg; 定量限为20 μg/kg; 添加浓度在20~1800 μg/kg范围内,平均添加回收率为76.4%~93.1%; 批内相对标准偏差(RSD)在2.6%~8.9%之间; 批间相对标准偏差(RSD)在4.7%~9.7%之间.样品浓度在0.07~10.0 mg/L范围内与峰面积呈良好的线性关系,r>0.9993.  相似文献   

18.
A method was developed for the quantitative analysis of the novel anticancer agent ES-285 (spisulosine; free base) in human, mouse, rat, and dog plasma using high-performance liquid chromatography/electrospray ionization tandem mass spectrometry in order to support pre-clinical and clinical studies with the drug. Sample preparation was carried out by protein precipitation with acetonitrile, containing isotopically labeled (d(3)) ES-285 as internal standard. Aliquots of 10 micro l of the supernatant were injected directly on to an Inertsil ODS-3 column (50 x 2.0 mm i.d., 5 micro m). Elution was carried out using methanol-10 mM ammonium formate (pH 4) in water (80 : 20, v/v) pumped at a flow-rate of 0.2 ml min(-1) with a run time of 8 min. Multiple reaction monitoring chromatograms obtained on an API365 triple-quadrupole mass spectrometer were used for quantification. The lower limit of quantitation (LLOQ) was 10 ng ml(-1) in human, mouse, rat, and dog plasma and the linear dynamic range extended to 500 ng ml(-1). A full validation of the method was performed in human plasma, and partial validations were performed in mouse, rat and dog plasma. Accuracies and precisions were <20% at the LLOQ concentration and <15% for all other concentrations in all matrices. ES-285 was stable during all steps of the assay. Thus far this method has been used successfully to analyze over 500 samples in pre-clinical trials, and will be implemented in the planned clinical phase I studies.  相似文献   

19.
A novel stability-indicating high-performance liquid chromatographic (HPLC) method was developed and validated for assay and determination of impurities of emtricitabine in drug substance. Emtricitabine was found to be degraded under acidic, alkaline, and oxidative stress conditions and to be more labile under oxidative conditions. The drug proved to be stable to dry heat and photolytic degradation. Resolution of major and minor degradation impurities was achieved on an Intersil ODS-3V column utilizing 10 mM sodium phosphate buffer and methanol (85:15) as mobile phase. Detection was at 280 nm. Validation studies were performed as per ICH recommended conditions. The developed method was found to be linear, accurate, specific, selective, precise, and robust.  相似文献   

20.
A novel HPLC method with fluorescence detection and one step sample preparation was developed for the determination of penciclovir in human plasma. Plasma samples (200 μL) were deproteinized by precipitation with 100 μL of perchloric acid and centrifuged. Separation was on an Inertsil ODS-3 column with a mixture of methanol–0.1% orthophosphoric acid as mobile phase. The fluorescence detector was set at Ex 270 nm, Em 375 nm. The assay was selective and linear with a limit of quantification of 0.025 mg L?1. The mean absolute recovery was 98.1%, while the intra- and inter-day coefficients of variation and percent error values of the assay method were all less than 10%. The assay was successfully applied in a randomized cross-over bioequivalence study of three pharmaceutical products containing 250 mg famciclovir (an oral prodrug of penciclovir) in 18 healthy volunteers.  相似文献   