1.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has been used to directly analyze and image pharmaceutical compounds in intact tissue. The anti-tumor drug SCH 226374 was unambiguously determined in mouse tumor tissue using MALDI-QqTOFMS (QSTAR) by monitoring the dissociation of the protonated drug at m/z 695.4 to its predominant fragment at m/z 228.1. A second drug, compound A, was detected in slices of rat brain tissue following oral administration with doses ranging from 1-25 mg/kg. Quantitation of compound A from whole brain homogenates using routine high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) procedures revealed that concentrations of the drug in whole brain varied from a low of 24 ng/g to a high of 1790 ng/g. The drug candidate was successfully detected by MALDI-QqTOF in samples from each dose, covering a range of approximately two orders of magnitude. In addition, good correlation was observed between the MALDI-QqTOFMS intensities at each dose with the HPLC/MS/MS results. Thus the MALDI-MS response is proportional to the amount of drug in tissue. Custom software was developed to facilitate the imaging of small molecules in tissue using the MALDI-QqTOF mass spectrometer. Images revealing the spatial localization of SCH 226374 in tumor tissue and compound A in brain tissue were acquired.  相似文献   

2.
Sensitive enantioselective liquid chromatographic assays using tandem mass spectrometric detection were developed and validated for the determination of S-cetirizine (S-CZE) and R-cetirizine (R-CZE) in guinea pig plasma, brain tissue, and microdialysis samples. Enantioselective separation was achieved on an alpha1-acid glycoprotein column within 14 min for all methods. A cetirizine analog, ucb 20028, was used as internal standard. Cetirizine and the internal standard were detected by multiple reaction monitoring using transitions m/z 389.1 --> 200.9 and 396.1 --> 276.1, respectively. The samples were prepared using protein precipitation with acetonitrile. For guinea pig plasma, the assay was linear over the range 0.25-5000 ng/mL for both S-CZE and R-CZE, with a lower limit of quantification (LLOQ) of 0.25 ng/mL. For the brain tissue and microdialysis samples, the assays were linear over the range 2.5-250 ng/g and 0.25-50 ng/mL, respectively, and the LLOQ values were 2.5 ng/g and 0.25 ng/mL, respectively. The intra- and inter-day precision values were < or =7.1% and < or =12.6%, respectively, and the intra- and inter-day accuracy varied by less than +/-8.0% and +/-6.0% of the nominal value, respectively, for both enantiomers in all the matrices investigated.  相似文献   

3.
Anacetrapib is a potent and selective CETP inhibitor and is undergoing phase III clinical trials for the treatment of dyslipidemia. A simple and sensitive high‐performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method for the quantification of anacetrapib in rat plasma was developed and validated using an easily purchasable compound, chlorpropamide, as an internal standard (IS). A minimal volume of rat plasma sample (20 μL) was prepared by a single‐step deproteinization procedure with 80 μL of acetonitrile. Chromatographic separation was performed using Kinetex C18 column with a gradient mobile phase consisting of water and acetonitrile containing 0.1% formic acid at a flow rate of 0.3 mL/min. Mass spectrometric detection was performed using selected reaction monitoring modes at the mass/charge transitions m/z 638 → 283 for anacetrapib and m/z 277 → 175 for IS. The assay was validated to demonstrate the selectivity, linearity, precision, accuracy, recovery, matrix effect and stability. The lower limit of quantification was 5 ng/mL. This LC‐MS/MS assay was successfully applied in the rat plasma protein binding and pharmacokinetic studies of anacetrapib. The fraction of unbound anacetrapib was determined to be low (ranging from 5.66 to 12.3%), and the absolute oral bioavailability of anacetrapib was 32.7%.  相似文献   

4.
A liquid chromatographic-mass spectrometry (LC/MS) assay method was developed for the determination of amiodarone and desethylamiodarone in rat specimens. Analytes were extracted using liquid-liquid extraction in hexane. The LC/MS system consisted of a Waters Micromass ZQtrade mark 4000 spectrometer with an autosampler and pump. A C(18) 3.5 microm (2.1 x 50 mm) column heated to 45 degrees C was used for separation. The mobile phase consisted of methanol and 0.2% aqueous formic acid pumped at 0.2 mL/min as a linear gradient. Components eluted within 12 min. The concentrations of ethopropazine (internal standard), desethylamiodarone and amiodarone were monitored for m/z of 313.10, combination of 546.9 and 617.73, and 645.83, respectively. In plasma (0.1 mL), linearity was achieved between the peak area ratios and concentrations over the range of 2.5-1000 ng/mL for both amiodarone and desethylamiodarone (r(2) > 0.999). The intraday and interday CV were equal or less than 18%, and mean error was <12%. Similarly, in homogenates containing 0.1 g of rat tissue, linearity was observed in standards ranging from 5 to 5000 ng/g. The method was successfully used to measure tissue and plasma concentrations of drug. The validated lower limit of quantitation was 2.5 ng/mL for drug and metabolite, based on 0.1 mL of plasma.  相似文献   

5.
A sensitive high-performance liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of quetiapine in rat plasma. Following liquid-liquid extraction, the analyte was separated using a gradient mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H]+ ions, m/z 384 to m/z 221 for quetiapine and m/z 327 to m/z 270 for the internal standard. The assay exhibited a linear dynamic range of 0.25-500 ng/mL for quetiapine in rat plasma. The lower limit of quantification was 0.25 ng/mL with a relative standard deviation of less than 7%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated method was successfully used to analyze rat plasma samples for application in pre-clinical pharmacokinetic studies. This method in rodent plasma could be adapted for quetiapine assay in human plasma.  相似文献   

6.
Anatoxin-a (AN) and homoanatoxin-a (HMAN) are potent neurotoxins produced by a number of cyanobacterial species. A new, sensitive liquid chromatography/multiple tandem mass spectrometry (LC/MS(n)) method has been developed for the determination of these neurotoxins. The LC system was coupled, via an electrospray ionisation (ESI) source, to an ion-trap mass spectrometer in positive ion mode. The [M+H](+) ions at m/z 166 (anatoxin-a) and m/z 180 (homoanatoxin-a) were used as the precursor ions for multiple MS experiments. MS(2)bond;MS(4) spectra displayed major fragment ions at m/z 149 (AN), 163 (HMAN), assigned to [Mbond;NH(3)+H](+); m/z 131 (AN), 145 (HMAN), assigned to [Mbond;NH(3)bond;H(2)O+H](+), and m/z 91 [C(7)H(7)](+). Although the chromatographic separation of these neurotoxins is problematic, reversed-phase LC, using a C(18) Luna column, proved successful. Calibration data for anatoxin-a using spiked water samples (10 mL) in LC/MS(n) modes were: LC/MS (25-1000 microg/L), r(2) = 0.998; LC/MS(2) (5-1000(microg/L), r(2) = 0.9993; LC/MS(3) (2.5-1000 microg/L), r(2) = 0.9997. Reproducibility data (% RSD, N = 3) for each LC/MS(n) mode ranged between 2.0 at 500 microg/L and 7.0 at 10 microg/L. The detection limit (S/N = 3) for AN was better than 0.03 ng (on-column) for LC/MS(3) which corresponded to 0.6 microg/L.  相似文献   

7.
Methylphenidate, a psychostimulant used for the treatment of attention deficit hyperactivity disorder and narcolepsy, is administered as a 50:50 racemic mixture, despite the fact that d‐methylphenidate has been shown to have greater pharmacologic activity. This paper presents a validated LC‐MS/MS approach to separation and quantification of methylphenidate enantiomers using a vancomycin column and triethylammonium acetate to enhance the chiral separation. The method is applicable to the monitoring of these enantiomers in mouse brain, with a limit of detection of 0.5 ng/mL and a lower limit of quantification of 7.5 ng/mL. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
Aripiprazole is an important antipsychotic drug. A simple, sensitive and rapid ultra‐performance liquid chromatography/electrospray ionization tandem mass spectrometry (UPLC‐ESI‐MS/MS) method was developed and validated for the simultaneous quantification of this compound in rat plasma and brain homogenate. The analyte was extracted from rat plasma and brain homogenate using a weak cation exchange mixed‐mode resin‐based solid phase extraction. The compound was separated on an Agilent Eclipse Plus C18 (2.1 × 50 mm, 1.8 µm) column using a mobile phase of (A) 0.1% formic acid aqueous and (B) acetonitrile with gradient elution. The analyte was detected in positive ion mode using multiple reaction monitoring. The method was validated and the specificity, linearity, limit of quantitation (LOQ), precision, accuracy, recoveries and stability were determined. The LOQ was 0.5 ng/mL for aripiprazole in plasma and 1.5 ng/g in brain tissue. The MS response was linear over the concentration range 0.5–100 ng/mL for aripiprazole in plasma and 1.5–300 ng/g in brain tissue. The precision and accuracy for intra‐day and inter‐day were better than 14%. The relative and absolute recoveries were above 72% and the matrix effects were low. This validated method was successfully used to quantify the rat plasma and brain tissue concentrations of the analyte following chronic treatment with aripiprazole. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
Pantoprazole, a proton pump inhibitor, is clinically used for the treatment of peptic diseases. An enantioselective LC‐MS/MS method was developed and validated for the simultaneous determination of pantoprazole enantiomers in human plasma. Pantoprazole enantiomers and the internal standard were extracted from plasma using acetonitrile. Chiral separation was carried on a Chiralpak IE column using the mobile phase consisted of 10 mm ammonium acetate solution containing 0.1% acetic acid–acetonitrile (28 : 72, v /v). MS analysis was performed on an API 4000 mass spectrometer. Multiple reactions monitoring transitions of m /z 384.1→200.1 and 390.1→206.0 were used to quantify pantoprazole enantiomers and internal standard, respectively. For each enantiomer, no apparent matrix effect was found, the calibration curve was linear over 5.00–10,000 ng/mL, the intra‐ and inter‐day precisions were below 10.0%, and the accuracy was within the range of –5.6% to 0.6%. This method was applied to the stereoselective pharmacokinetic studies in human after intravenous administration of S ‐(–)‐pantoprazole sodium injections. No chiral inversion was observed during sample storage, preparation procedure and analysis. While R ‐(+)‐pantoprazole was detected in human plasma with a slightly high concentration, which implied that S ‐(–)‐pantoprazole may convert to R ‐(+)‐pantoprazole in some subjects.  相似文献   

10.
A rapid and sensitive HPLC enantioselective method with fluorescence detection was developed to determine (-)-(R) and (+)-(S) enantiomers of the metabolites of citalopram, demethyl- and didemethyl-citalopram in plasma and brain tissue. This assay involves pre-column chiral derivatization with (-)-(R)-1-(1-naphthyl)ethyl isocyanate followed by separation on a normal-phase silica column. The developed liquid-liquid extraction procedure permits quantitative determination of analytes with recoveries ranged between 81 and 88% with intra- and inter-day relative standard deviations less than 10.5%. Linearity was obtained over the concentration range 5-1000 ng/mL and 100-10,000 ng/g for spiked drug-free plasma and brain tissue, respectively, with detection limits lower than 2.1 ng/mL and 42.8 ng/g.  相似文献   

11.
A sensitive, specific, accurate and reproducible high-performance liquid chromatography (HPLC) analytical method was developed and validated for the quantification of the novel oral taxane analogue BAY59-8862 in mouse plasma and tissue samples. A fully automated solid-phase extraction procedure was applied to the plasma after internal standard (IS) addition, with only 0.2 mL volume of the sample loaded on a CN-Sep-pak cartridge. In the case of the tissues a very simple acetonitrile extraction was used to recover BAY59-8862 and its internal standard from liver. The procedure for the quantification of BAY59-8862 and its IS (IDN5127) is based on high-performance liquid chromatography/ion spray-tandem mass spectrometry, operating in selected ion monitoring mode. The retention times of BAY and IS were 7.21 and 10.36 min, respectively. In both plasma and tissue specimens the assay was linear in the range 50-5000 ng/mL (ng/g). The overall precision and accuracy were assessed on three different days. The results for plasma were within 6.1% (precision) and between 99 and 112% (accuracy), and for the liver samples within 7.3% and between 104 and 118%, respectively. The LOD was 5 ng/mL and 20 ng/g in the plasma and liver, respectively. In addition, the biliary excretion of the compound in rats was studied. The study showed that an oxidative chemical reaction was the preferred metabolic pathway for biliary excretion, and two sets of mono- and dihydroxylated metabolites were detected by LC/ISP-MS/MS experiments. With this method, BAY59-8862 pharmacokinetic was determined in mice. The combined results demonstrate that the methodology can be considered a valid approach to conduct pharmacokinetic and metabolic studies during preclinical and clinical investigations.  相似文献   

12.
A simple, sensitive and robust liquid chromatography/electrospray ionization tandem mass spectrometry (LCESI-MS/MS) method with low matrix effects was developed and validated for the quantification of the lipophilic antipsychotic ziprasidone from rat plasma and brain tissue. Ziprasidone was extracted from rat plasma and brain homogenate using a single-step liquid-liquid extraction. Ziprasidone was separated on an Agilent Eclipse XDB C8 column (150 x 2.1 mm i.d., 5 microm) column using a mobile phase of acetonitrile-0.02% ammonia in water (pH 7.20 adjusted with formic acid) using gradient elution. Ziprasidone was detected in the positive ion mode using multiple reaction monitoring. The method was validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recovery, matrix effects and stability were determined. The LLOQ was 0.2 ng/mL for plasma and 0.833 ng/g for brain tissue. The method was linear over the concentration range from 0.2 to 200.0 ng/mL for plasma and 0.833-833.3 ng/g for brain tissue. The correlation coefficient (R2) values were more than 0.996 for both plasma and brain homogenate. The precision and accuracy intra-day and inter-day were better than 8.13%. The relative and absolute recovery was above 81.0% and matrix effects were lower than 5.2%. This validated method has been successfully used to quantify the rat plasma and brain tissue concentration of ziprasidone after chronic treatment.  相似文献   

13.
An accurate, reliable, and reproducible analytical method using HPLC/MS/MS for the determination of tulathromycin residues in bovine liver and porcine kidney via their common hydrolytic fragment (CP-60,300) was developed and validated. Briefly, the method involved an initial acid treatment of intact tissues, which yielded the common fragment (CP-60,300). A portion of the acid hydrolyzate was purified by SPE using a strong cation exchange cartridge. Evaporation of the purified extract was followed by reconstitution in aqueous buffer and analysis by HPLC/MS/MS under isocratic conditions. The developed method provided acceptable sensitivity for determinative surveillance of tulathromycin in porcine kidney and bovine liver with an LOQ of 7.50 and 2.75 microg/g, respectively. The overall recovery and precision of 45 determinations of each tissue were 97.8% (5.3%) for porcine kidney and 96.9% (7.9%) for bovine liver. Accuracy, precision, linearity, specificity, and ruggedness were demonstrated. An HPLC/MS/MS method was also developed for use in these tissues as a confirmatory assay following modifications to the MS detection parameters. The confirmatory method demonstrated acceptable sensitivity for confirmatory evaluation of tulathromycin in porcine kidney and bovine liver at tolerances of 15 and 5.5 microg/g, respectively.  相似文献   

14.
A liquid chromatography/tandem mass spectrometry (LC/MS/MS) method is described for the extraction, cleanup, determination, and confirmation of chloramphenicol (CAP) in cooked crab meat. The method involves pulverization of cooked crab meat with dry ice; extraction of the CAP into ethyl acetate (EtOAc); evaporation (by N2) of the EtOAc; addition of methanol, aqueous NaCl, and heptane; extraction of the lipids into the heptane, followed by extraction of the aqueous phase with EtOAc; evaporation (by N2) of the EtOAc; dissolution into methanol-water; filtration; and separation/detection/confirmation using LC/MS/MS. Crab meat was fortified at 0.25, 0.50, and 1.0 ng/g (ppb) chloramphenicol. Average absolute recoveries were 67, 84, and 86%, respectively, with relative standard deviation values all less than 1%. Four daughter ions (m/z 152, 176, 194, and 257) were monitored off the m/z 321 precursor ion. Determination was based on a standard curve using the peak areas of the m/z 152 daughter ion (the base peak) for standard solutions equivalent to 0.10, 0.20, 0.50, and 1.0 ppb in tissue (made with control crab extract). A set of 6 matrix controls (unfortified crab meat) was also analyzed, in which no chloramphenicol was detected. For identification purposes, the ion ratios (of each daughter ion versus the base daughter ion) of the fortified crab versus those of the chloramphenicol standards agreed within 10% (relative) at fortified chloramphenicol concentrations of 0.25-1.0 ppb.  相似文献   

15.
建立正相液相色谱-串联质谱(LC-MS/MS)分离普萘洛尔对映体的方法,并用于盐酸普萘洛尔片对映体含量测定.样品使用甲醇进行简单提取,采用Chiralcel OD-H手性柱,以正己烷-乙醇-氨水(70∶30∶0.4, v/v/v)为流动相,流速为0.4 mL/min.在正离子模式下,通过电喷雾离子化(ESI+),采用多...  相似文献   

16.
Tizoxanide, the active metabolite of nitazoxanide, has recently been reported as an effective agent for the treatment of glioma. As there had been no report about the analysis of tizoxanide in brain tissue, we established extraction and UHPLC–MS/MS methods to quantify tizoxanide in rat brain and plasma to evaluate the brain-to-plasma ratio of tizoxanide. The biological samples were mainly prepared by acetonitrile and the separation was performed on a Waters XBridge® BEH C18 column. The mobile phase was composed of water mixed with 10 mm ammonium formate (pH 3.0) and acetonitrile according a gradient volume. Tizoxanide and topiramate (internal standard) were monitored utilizing negative electron spray ionization in multiple reaction monitoring mode. The methods were validated to be precise and accurate within the dynamic range of 5–1000 ng/mL and 0.2–50 ng/g for plasma and brain tissue samples, respectively. The lower limit of quantitation of the method was 0.2 ng/g, which was far more sensitive than all existing methods to quantify tizoxanide in biological samples. Application performed on rats exhibited that the brain-to-plasma ratio of tizoxanide ranged from 3.16 to 26.86% in 1 h after administration of 10 mg/kg nitazoxanide.  相似文献   

17.
Reversed-phase chromatography is the most common means of separation for small drug molecules. However, polar drugs may suffer from poor retention and peak shape in reversed-phase high-performance liquid chromatography (RP-HPLC). Hydrophilic interaction liquid chromatography (HILIC) provides a viable alternative to RP-HPLC and is an excellent way to separate polar compounds. This paper describes a HILIC/ESI-MS/MS assay for the determination of acyclovir from rat plasma, amniotic fluid, placental tissue, and fetal tissue. The isocratic separation utilizes an underivatized silica column with an acetonitrile/formate buffer mobile phase (80:20). The method is validated over a range of 50 ng/mL to 50 micro g/mL with % error and % relative standard deviation of <15% over 3 days. All samples are prepared by acetonitrile protein precipitation, which yields high recovery (>84% for acyclovir). This assay can be applied to the pharmacokinetic study of the placental transfer of acyclovir.  相似文献   

18.
A sensitive liquid chromatography-electrospray ionization-tandem mass spectrometric (LC-ESI-MS/MS) method for the determination of the rat brain 5alpha-androstane-3alpha,17beta-diol (3alpha,5alpha-Adiol) has been developed and validated. The brain extract was purified using solid-phase extraction cartridges, derivatized with isonicotinoyl azide, and subjected to LC-MS/MS. The method was accurate and reproducible, and the limit of quantitation was 0.1 ng/g tissue when a 100-mg tissue sample was used. The change in the brain 3alpha,5alpha-Adiol level by immobilization stress was also analyzed using the developed method.  相似文献   

19.
The disposition of the cannabimimetic naphthalen‐1‐yl‐(1‐pentylindol‐3‐yl)methanone (JWH‐018) in mice following inhalation of the smoke of the herbal incense product (HIP) ‘Buzz’ is presented. A high‐pressure liquid chromatography with electrospray ionization triple quadrupole mass spectrometer (HPLC/MS/MS) method was validated for the analysis of JWH‐018 in the specimens using deuterated Δ9‐tetrahydrocannabinol (d3‐THC) as the internal standard. JWH‐018 was isolated by cold acetonitrile liquid–liquid extraction. Chromatographic separation was performed on a Zorbaz eclipse XDB‐C18 column. The assay was linear from 1 to 1000 ng/mL. Six C57BL6 mice were sacrificed 20 min after exposure to the smoke of 200 mg ‘Buzz’ containing 5.4% JWH‐018. Specimen concentrations of JWH‐018 were: blood, 54–166 ng/mL (mean 82 ± 42 ng/mL); brain, 316–708 ng/g (mean 510 ± 166 ng/g); and liver, 1370–3220 ng/mL (mean 1990 ± 752 ng/mL). The mean blood to brain ratio for JWH‐018 was 6.8 and ranged from 4.2 to 10.9. After exposure, the responses of the mice were consistent with cannabinoid receptor type 1 activity: body temperatures dropped 7.3 ± 1.1 °C, and catalepsy, hyperreflexia, straub tail and ptosis were observed. The brain concentrations and physiological responses are consistent with the hypothesis that the behavioral effects of ‘Buzz’ are attributable to JWH‐018. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
Acetaldehyde, the main biological metabolite of ethanol, is nowadays considered to mediate some ethanol-induced effects. Previous studies on alcohol effect attenuation have shown that D-(-)-penicillamine (3-mercapto-D-valine), a thiol amino acid, acts as an effective agent for the inactivation of acetaldehyde. In the study reported here, laboratory rats were treated with ethanol and D-(-)-penicillamine at different doses looking for the interaction (in vivo) of D-(-)-penicillamine with metabolically formed acetaldehyde following a condensation reaction to form the stable adduct (4S,2RS)-2,5,5-trimethylthiazolidine-4-carboxylic acid (TMTCA). A novel and rapid procedure based on liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS) was developed for quantification and reliable identification of TMTCA in different rat tissues, including plasma, liver and brain. Firstly, plasma was obtained from whole blood. Then, proteins were precipitated from plasma, brain and liver extracts with acetonitrile and the clarified extracts diluted 10-fold. A 20 microL aliquot of the final extracts was then analyzed using an Atlantis C18 5 microm, 100x2 mm column which was connected to the electrospray source of a LC/triple quadrupole mass spectrometer. The analyte was detected in positive ion mode acquiring four MS/MS transitions in selected reaction monitoring (SRM) mode.The method has been validated and it has proved to be fast, reliable and sensitive. The accuracy and precision were evaluated by means of recovery experiments from plasma, liver and brain samples fortified at two concentration levels obtaining satisfactory recoveries in all cases: 95 and 105% in plasma (at 10 and 100 ng/mL, respectively), 79 and 89% in brain (100 and 1000 ng/g), 85 and 99% in liver (100 and 1000 ng/g). Precision, expressed as repeatability, was in all tissues analyzed lower than 17% at the two concentrations tested. The estimated detection limits were 1 ng/mL in plasma, 4 ng/g in brain and 5 ng/g in liver. The limit of quantitation objective (the lowest concentration that was validated with acceptable results) was set up at 10 ng/mL for plasma and 100 ng/g for brain and liver tissue.The reliable identification of the analyte was ensured by the acquisition of four transitions and by their ion abundance ratio measurement. Due to its excellent selectivity and sensitivity, the method developed in this work provides an excellent tool for the specific determination of this cyclic amino acid in biological samples.  相似文献   