首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Sixteen peptides (trimers to hexamers) were designed for use as a set of pI markers for capillary isoelectric focusing (CIEF). Each peptide contains one tryptophan residue for detection by UV absorption and other amino acid residues having ionic side chains, which are responsible for focusing to its pI. The pIs of these peptides were determined by slab-gel IEF using commercial carrier ampholytes. The focused peptides in the gel were detected by absorption measurement at 280 nm using a scanning densitometer and the pH gradient was determined by measuring the pH of the gel using an oxidized metal membrane electrode. The pI values of the peptides ranged from 3.38 to 10.17. The obtained values agreed well with the predicted ones, which were calculated based on amino acid compositions, with root mean square differences of 0.15 pH unit. The peptides were detected at 280 nm as very sharp peaks when separated by CIEF. The pI values of some standard proteins were redetermined by CIEF by using this set of peptide pI markers and the values agreed closely with those reported previously. The sharp focusing, stability, high purity and high solubility of these synthetic pI markers should facilitate the profiling of a pH gradient in a capillary and the determination of the pI values of proteins.  相似文献   

2.
Colored, low molecular weight pI markers have been developed for isoelectric focusing (IEF) in acidic pH range. Their isoelectric points (pIs) were determined by direct measurement of the pH of the focused bands after completion of IEF on polyacrylamide gels. The practicable suitability of the proposed pI markers as pI standards for IEF was tested by applying gel IEF. The acidic pH gradient was created either by commercial synthetic carrier ampholytes or by mixture of simple buffers consisting of acids (non-ampholytes) and ampholytic buffers. By applying simple acids, it was possible to extend the acidic pH range beyond those achievable with commercial synthetic carrier ampholytes. By using an experimental arrangement without electrode electrolyte reservoirs with electrodes creating the fixed end of the gel, the strongly acidic pH gradient was stable even for prolonged focusing time.  相似文献   

3.
North RY  Vigh G 《Electrophoresis》2008,29(5):1077-1081
The operational pH value of a buffering membrane used in an isoelectric trapping separation is determined by installing the membrane as the separation membrane into a multicompartmental electrolyzer operated in the two-separation compartment configuration. A 3相似文献   

4.
The impact of initial sample distribution on separation and focusing of analytes in a pH 3–11 gradient formed by 101 biprotic carrier ampholytes under concomitant electroosmotic displacement was studied by dynamic high-resolution computer simulation. Data obtained with application of the analytes mixed with the carrier ampholytes (as is customarily done), as a short zone within the initial carrier ampholyte zone, sandwiched between zones of carrier ampholytes, or introduced before or after the initial carrier ampholyte zone were compared. With sampling as a short zone within or adjacent to the carrier ampholytes, separation and focusing of analytes is shown to proceed as a cationic, anionic, or mixed process and separation of the analytes is predicted to be much faster than the separation of the carrier components. Thus, after the initial separation, analytes continue to separate and eventually reach their focusing locations. This is different to the double-peak approach to equilibrium that takes place when analytes and carrier ampholytes are applied as a homogenous mixture. Simulation data reveal that sample application between two zones of carrier ampholytes results in the formation of a pH gradient disturbance as the concentration of the carrier ampholytes within the fluid element initially occupied by the sample will be lower compared to the other parts of the gradient. As a consequence thereof, the properties of this region are sample matrix dependent, the pH gradient is flatter, and the region is likely to represent a conductance gap (hot spot). Simulation data suggest that sample placed at the anodic side or at the anodic end of the initial carrier ampholyte zone are the favorable configurations for capillary isoelectric focusing with electroosmotic zone mobilization.  相似文献   

5.
Capillary isoelectric focusing in the presence of electroosmosis with sequential injection of carrier ampholytes and sample was found to be suitable for MS detection. The separate injection of the sample and the ampholytes provides good condition to suppress and overcome the undesirable effect of the presence of ampholytes in MS. By the appropriate selection of ampholyte solutions, whose pH range not necessarily covers the pI values of the analytes, the migration of the components can be controlled, and the impact of the ampholytes on MS detection is decreased. The unique applicability of this setup is shown by testing several parameters, such as the application of volatile electrolyte solutions, the type of the ampholytes, the order and the number of the ampholyte and sample zones. Broad and narrow pH range ampholytes were applied in experiments using uncoated capillaries with different lengths for the analyses of substituted nitrophenol dyes to achieve optimal conditions for the MS detection. Although the sample components are not leaving the pH gradient, due to the decrease in the ampholyte concentration at the position of the components, and because the sample components migrate in charged state, the ionisation is more effective for MS detection.  相似文献   

6.
Titration curves of reduced and alkylated polypeptide chains can be successfully performed in 8 M urea-polyacrylamide gel plates by electrophoresis perpendicular to a stationary stack of focused carrier ampholytes. All buffers and thiol reagents with pK values in the range pH 3--10 should be removed, since their pH-dependent ionization affects the migration and apparent pI values of the protein chains. No blurring of the patterns below pH 4.5 is observed, as usually found in titration curves in the absence of urea, thus allowing the direct titration of Glu and Asp residues. It is not possible by the present technique to titrate any group below pH ca. 3 and above pH ca. 10, due to the lack of suitable carrier ampholytes and to a "flooding" phenomenon, with concomitant identical electrophoretic mobility for all protein species, irrespective of their relative pI values and amino acid composition. The "electrophoretic titration curves" thus obtained were well correlated with the overall amino acid composition of the polypeptide chains analyzed.  相似文献   

7.
Xu Z  Okabe N  Arai A  Hirokawa T 《Electrophoresis》2010,31(21):3558-3565
This paper reports the protein analysis by using microchip IEF carried on an automated chip system. We herein focused on two important topics of microchip IEF, the pH gradient and cathodic drift. The computer simulation clarified that the EOF could delay the establishment of pH gradient and move the carrier ampholytes (CAs) to cathode, which probably caused a cathodic drift to happen. After focusing, the peak positions of components in a calibration kit with broad pI were plotted against their pI values to know the actual pH gradient in a microchannel varying time. It was found that the formed pH gradient was stable, not decayed after readily steady state, and migrated to cathode at a rate of 10.0 μm/s that determined by the experimental conditions such as chip material, internal surface coating and field strength. The theoretical pH gradient was parallel with the actual pH gradient, which was demonstrated in two types of microchip with different channel lengths. No compression of pH gradient was observed when 2% w/v hydroxypropyl methyl cellulose was added in sample and electrolytes. The effect of CAs concentration on current and cathodic drift was also explored. With the current automatic chip system, the calculated peak capacity was 23–48, and the minimal pI difference was 0.20–0.42 for the used single channel microchip with the effective length of 40.5 mm. The LOD for the analysis of CA‐I and CA‐II was around 0.32 μg/mL by using normal imaged UV detection, the detected amount is ca. 0.07 ng.  相似文献   

8.
Electrokinetic processes that lead to pH gradient instabilities in carrier ampholyte-based IEF are reviewed. In addition to electroosmosis, there are four of electrophoretic nature, namely (i) the stabilizing phase with the plateau phenomenon, (ii) the gradual isotachophoretic loss of carrier ampholytes at the two column ends in presence of electrode solutions, (iii) the inequality of the mobilities of positively and negatively charged species of ampholytes, and (iv) the continuous penetration of carbonate from the catholyte into the focusing column. The impact of these factors to cathodic and anodic drifts was analyzed by simulation of carrier ampholyte-based focusing in closed and open columns. Focusing under realistic conditions within a 5 cm long capillary in which three amphoteric low molecular mass dyes were focused in a pH 3–10 gradient formed by 140 carrier ampholytes was investigated. In open columns, electroosmosis displaces the entire gradient toward the cathode or anode whereas the electrophoretic processes act bidirectionally with a transition around pH 4 (drifts for pI > 4 and pI < 4 typically toward the cathode and anode, respectively). The data illustrate that focused zones of carrier ampholytes have an electrophoretic flux and that dynamic simulation can be effectively used to assess the magnitude of each of the electrokinetic destabilizing factors and the resulting drift for a combination of these effects. Predicted drifts of focused marker dyes are compared to those observed experimentally in a setup with coated capillary and whole column optical imaging.  相似文献   

9.
Mosher RA  Thormann W 《Electrophoresis》2008,29(5):1036-1047
The impact of the systematic variation of either DeltapK(a) or mobility of 140 biprotic carrier ampholytes on the conductivity profile of a pH 3-10 gradient was studied by dynamic computer simulation. A configuration with the greatest DeltapK(a) in the pH 6-7 range and uniform mobilities produced a conductivity profile consistent with that which is experimentally observed. A similar result was observed when the neutral (pI = 7) ampholyte is assigned the lowest mobility and mobilities of the other carriers are systematically increased as their pI's recede from 7. When equal DeltapK(a) values and mobilities are assigned to all ampholytes a conductivity plateau in the pH 5-9 region is produced which does not reflect what is seen experimentally. The variation in DeltapK(a) values is considered to most accurately reflect the electrochemical parameters of commercially available mixtures of carrier ampholytes. Simulations with unequal mobilities of the cationic and anionic species of the carrier ampholytes show either cathodic (greater mobility of the cationic species) or anodic (greater mobility of the anionic species) drifts of the pH gradient. The simulated cationic drifts compare well to those observed experimentally in a capillary in which the focusing of three dyes was followed by whole column optical imaging. The cathodic drift flattens the acidic portion of the gradient and steepens the basic part. This phenomenon is an additional argument against the notion that focused zones of carrier ampholytes have no electrophoretic flux.  相似文献   

10.
Chmelík J  Mazanec K  Slais K 《Electrophoresis》2007,28(18):3315-3323
A new proteomic staining-free method for simultaneous identification of proteins and determination of their pI values by using low-molecular-mass pI markers is described. It is based on separation of proteins in gels by IEF in combination with mass spectrometric analysis of both peptides derived by in-gel digestion and low-molecular-mass pI markers extracted form the same piece excised from the gel. In this method, the pI markers are mixed with a protein mixture (a commercial malted barley protein extract) deposited on a gel and separated in a pH gradient. Color pI markers enable supervision of progress of focusing process. Several separated bands of the pI markers (including separated proteins) were excised and the pI markers were eluted from each gel piece by water/ethanol and identified by MALDI-TOF/TOF MS. The remaining carrier ampholytes were then washed out from gel pieces and proteins were in-gel digested with trypsin or chymotrypsin. Obtained peptides were measured by MALDI-TOF/TOF MS and proteins were identified via protein database search. This procedure allows omitting time-consuming protein staining and destaining procedures, which shortens the analysis time. For comparison, other IEF gels were stained with CBB R 250 and proteins in the gel bands were identified. Similarity of the results confirmed that our approach can give information about the correct pI values of particular proteins in complex samples at significantly shorter analysis times. This method can be very useful for identification of proteins and their post-translational modifications in prefractioned samples, where post-translational modifications (e.g., glycation) are frequent.  相似文献   

11.
Capillary electrophoresis analysis of transferrin in human serum is used to assess genetic variants after desialylation with neuraminidase and iron saturation to reduce the complexity of the transferrin pattern and thus facilitate the recognition of transferrin polymorphisms. Asialo‐transferrin forms are analyzed by capillary zone electrophoresis using assay conditions as for the monitoring of carbohydrate‐deficient transferrin or by capillary isoelectric focusing in a pH 5–8 gradient which requires immunoextraction of transferrin prior to analysis. With the carrier ampholytes used, peaks for iron saturated and iron depleted transferrin are monitored which indicates complexation of iron ions by carrier ampholytes. For BC, CD, and BD genetic variants, the expected peaks for B, C, and D forms of transferrin were detected with both methods. Monitoring of CC patterns revealed three cases, namely those producing double peaks in both methods, a double peak in capillary isoelectric focusing only and a double peak in capillary zone electrophoresis only. For all samples analyzed, data obtained by capillary isoelectric focusing could be confirmed with gel isoelectric focusing. The two capillary electrophoresis methods are shown to represent effective tools to assess unusual transferrin patterns, including genetic variants with dissimilar abundances of the two forms.  相似文献   

12.
We prepared a series of low-molecular-mass fluorescent ampholytes with narrow pI range. These fluorescein-based ampholytes are detection compatible with argon laser-induced fluorescence (LIF) detection. The selected properties, important for their routine use as fluorescent pI markers, were examined. The pI values of new fluorescein-based pI markers were determined by capillary isoelectric focusing (CIEF) using currently available low-molecular-mass pI markers for CIEF with photometric detection. The examples of CIEF with fluorometric detection of new compounds together with fluorescein isothiocyanate (FITC) derivatized proteins are presented.  相似文献   

13.
This paper presents an imaging capillary isoelectric focusing (CIEF) assay for the determination of the identity, stability, and isoform distribution of a murine monoclonal antibody (MU-B3). The experiments were conducted using a Convergent Bioscience iCE280 instrument. The optimum carrier ampholyte composition that gave the best peak separation was found to be 25% Pharmalyte pH 3-10 and 75% Pharmalyte pH 5-8. The antibody gave a highly reproducible CIEF profile with three major peaks having average isoelectric point (pI) values of 6.83, 6.99, and 7.11. Intraday and interday reproducibility of pI values was found to be within RSD of 0.5%. The CIEF profile was also the same, with an alternate column cartridge and alternate batches of methyl cellulose. A plot of peak areas versus MU-B3 concentration was linear (R2 = 0.995) up to a concentration of 0.5 mg/mL in the sample solution. Peak area measurements were reproducible to within 7% RSD. The CIEF profiles of two other antibodies were distinctly different from the profile of MU-B3, showing that the assay is specific. After a sample of MU-B3 was subjected to heat stress by exposure to heat at 55 degrees C for 4 h, its CIEF profile was altered with extra peaks appearing at lower pI values, indicating that the assay could be used to monitor stability. The result of the heat stress experiment was also confirmed with a parallel slab-gel IEF analysis of the antibody sample before and after application of the heat stress. The results of this work suggest that imaging CIEF can be used for product testing under a quality control environment. The assay can be used for pI profiling of proteins and for monitoring structural changes (deamidation, glycosylation, etc.) during the manufacturing process and upon storage.  相似文献   

14.
The use of low-molecular-mass color pI markers for the determination of pI values of proteins in gel isoelectric focusing (IEF) in combination with mass spectrometry is described. Different types of substituted phenols of known pI values within the mass range 250-400 were used here as pI markers. The pure, synthesized pI markers were studied by MALDI-TOF/TOF MS. Fragmentation studies of the pI markers were also performed. Only stable and well-characterized pI markers were used in this work. The selected pI markers were mixed with proteins, deposited on a gel and separated in a pH gradient. Color pI markers enable supervision of progress of the focusing process and also estimation of the position of the invisible focused bands. The separated bands of the pI markers (containing separated proteins) were excised, and the pI markers were eluted from each gel piece by water/ethanol and identified by MALDI-TOF/TOF MS. From the washed gel pieces the remaining carrier ampholytes were then washed out and proteins were in-gel digested with trypsin. The obtained peptides were measured by MALDI-TOF/TOF MS and the proteins identified via a protein database search. This procedure allows avoiding time-consuming protein staining and destaining procedures, which shortens the analysis time roughly by half. For comparison, IEF gels were stained with Coomassie Brilliant Blue R 250 and proteins in the gel bands were identified according to the standard proteomic protocol. This work has confirmed that our approach can give information about the correct pI values of particular proteins and shorten significantly the time of analysis.  相似文献   

15.
Fleisher HC  Vigh G 《Electrophoresis》2005,26(13):2511-2519
Diaminocarboxylic acid carrier ampholytes, such as L-histidine, 2,3-diaminopropionic acid, L-ornithine, and L-lysine, were reacted with glycerol-1,3-diglycidyl ether (GDGE) and poly(vinyl alcohol) (PVA) in the presence of sodium hydroxide to produce hydrolytically and mechanically stable hydrogels, supported on a PVA substrate, for use as buffering membranes in isoelectric trapping (IET) separations. The pH values of the DACAPVA membranes were determined with the help of small-molecule pI markers and proteins and were found to be in the 6 < pH < 8.5 range. The membranes were successfully used to isoelectrically trap small ampholytes, desalt ampholyte solutions in IET mode, and effect the binary separation of chicken egg white proteins.  相似文献   

16.
Tracy NI  Ivory CF 《Electrophoresis》2004,25(12):1748-1757
Recombinant proteins are often produced as isoforms with different kinds and amounts of post-translational modifications that alter their function. Isoelectric focusing in shallow pH gradients, less than 0.5 pH/cm, might be capable of fractionating these isoforms. The synthetic carrier ampholyte mixtures typically used to generate these pH gradients are expensive and may adversely interact with proteins. Using defined buffers instead of synthetic carrier ampholytes reduces these problems. We tested two defined buffer systems in a vortex-stabilized electrophoresis device to see if they could form shallow pH gradients useful for separating isoforms. These pH gradients were formed by pouring a two-component concentration gradient. The poured gradients were smooth, reproducible, and stable for at least 1.5 h at 5 kV. One poured gradient focused 20 mg of cytochrome c. A second poured gradient separated glucose oxidase from amyloglucosidase. The breadth of the amyloglucosidase band indicates that the shallow, poured pH gradients can only partially separate protein isoforms at 10 kV. Proteins with pI < 0.2 pH units apart will have overlapping bands in these shallow, poured pH gradients.  相似文献   

17.
Sample preparation is often necessary to separate and concentrate various compounds prior to analysis of complex samples. In this regard, isoelectric focusing (IEF) is one of the best sample preparation methods. With this approach, however, carrier ampholytes have to be introduced into the samples, which may result in matrix interferences. In this paper, a simple ampholyte-free IEF free-flow electrophoresis design was developed for the separation of proteins. beta-Lactoglobulin, hemoglobin, myoglobin and cytochrome c were selected as model analytes. The experimental design took advantage of the electrolysis-driven production of H(+) and OH(-) ions that migrated from the anode and cathode, respectively, establishing a pH gradient spanning from 2.3 to 8.9. The separation chamber was filled with silanized glass beads as a support medium. Dialysis membranes were mounted at the two sides of the separation chamber (made of glass slides) and sealed with 2% agarose gel. The separated proteins drained from the outlets of the separation chamber and could be successfully collected into small glass tubes. The focusing process was visually observed and the separation was confirmed by capillary isoelectric focusing (cIEF) with pI markers.  相似文献   

18.
Jin Y  Luo G  Oka T  Manabe T 《Electrophoresis》2002,23(19):3385-3391
Synthetic UV-detectable peptide pI markers were used to estimate isoelectric point (pI) values of proteins separated by capillary isoelectric focusing (CIEF) followed by cathodic mobilization in the absence of denaturing agents. The pI calculation and quantitative analysis of purified proteins showed the feasibility of these peptides as pI markers and internal standards in CIEF separation of proteins. Estimation of pI values of major proteins in human plasma was performed using the peptide pI markers, and the values were compared with those previously obtained by gel isoelectric focusing (IEF). Sera of immunoglobulin G (IgG) myeloma patients, which showed characteristic peaks of myeloma IgG in their CIEF patterns, were also subjected to the analysis and the pI values of the myeloma proteins have been estimated.  相似文献   

19.
Capillary isoelectric focusing hyphenated with mass spectrometry detection, following the sequential injection of the carrier ampholytes and the sample zone, is highly efficient for the characterization of proteins. The main advantage of the sequential injection protocol is that ampholytes, with pH ranges, which are not supposed to cover the isoelectric points of the sample components, can be used for separation. The method then allows online mass spectrometry detection of separated analytes either in the absence (substances that have left the pH gradient) or in the presence of low‐level ampholytes (substances that are migrating within the pH gradient). The appearance of the substances within, or outside the pH gradient depends on, e.g., the composition of the ampholytes (broad or narrow pH range) or on the composition of electrolyte solutions. The experiments performed in coated capillaries (with polyvinyl alcohol or with polyacrylamide) show that the amount and the injection length of the ampholytes influence the length of the pH gradient formed in the capillary.  相似文献   

20.
Commercial carrier ampholytes, obtained by coupling polyethylene polyamines to acrylic acid, exhibit a conductivity minimum in the pH range 5.5-6.5 owing to the lack of appropriate pK values of the polyamine in this pH region. By replacing acrylic with itaconic acid, it has been possible to effect substantial improvements in the pH range 5.5-6.5 as itaconic acid has a pK2 value of 5.45. Upon coupling, the pK of the gramma-carboxyl group remains virtually unaltered. With itoconic acid carrier ampholytes it has been possible to improve the conductivity in the pH range 5.5-6.5 by as much as 400% compared with conventional carrier ampholytes. It is suggected that the commercial products should be supplemented with itaconic acid carrier ampholytes in order to obtain a more uniform conductivity and buffering capacity in the pH range 3-10.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号